Szymon Tamborski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Szymon Tamborski has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Maciej Szkulmowski
Nicolaus Copernicus University in Torun
24 shared publications - Maciej Wojtkowski
International Centre for Translational Eye Research
14 shared publications Danuta Bukowska
Lion's Eye Institute (Australia)
6 shared publicationsAndrzej Kowalczyk
Nicolaus Copernicus Univ. (Poland)
5 shared publicationsDaniel Szlag
Laboratoire d'Optique Biomédicale, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
5 shared publications- Grzegorz Marek Wilczynski
Nencki Institute of Experimental Biology
5 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (11) , 5536
Accurate determination of the refractive index in biological tissues using limited-angle optical diffraction tomography: a case study on mouse retina
We present a comprehensive framework for quantitative refractive index (RI) determination in biological tissues using limited-angle optical diffraction tomography (LA-ODT), combining immersion matching, missing-cone error correction based on optical volume conservation, and layer-specific fill-factor analysis. This approach is demonstrated on the mouse retina, yielding accurate mean RI values for eight retinal layers under hydrated (PBS) conditions, and the RI distribution of non-aqueous tissue components. Comparison of formalin-fixed, paraffin-embedded (FFPE) specimens and frozen sections revealed no significant RI bias induced by FFPE processing. The proposed methodology provides a robust, quantitative, and transferable framework for RI characterization in diverse biological tissues.
- 7 October 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (11) , 5536
Open AccessAccurate determination of the refractive index in biological tissues using limited-angle optical diffraction tomography: a case study on mouse retina
We present a comprehensive framework for quantitative refractive index (RI) determination in biological tissues using limited-angle optical diffraction tomography (LA-ODT), combining immersion matching, missing-cone error correction based on optical volume conservation, and layer-specific fill-factor analysis. This approach is demonstrated on the mouse retina, yielding accurate mean RI values for eight retinal layers under hydrated (PBS) conditions, and the RI distribution of non-aqueous tissue components. Comparison of formalin-fixed, paraffin-embedded (FFPE) specimens and frozen sections revealed no significant RI bias induced by FFPE processing. The proposed methodology provides a robust, quantitative, and transferable framework for RI characterization in diverse biological tissues.
- 29 June 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (8) , 4390-4403
Wide-field, real-time limited-angle optical diffraction tomography using massively parallel data processing
We present a GPU-accelerated reconstruction framework enabling real-time imaging in limited-angle optical diffraction tomography (LaODT). The implementation leverages massively parallel computing to achieve fast and efficient volumetric reconstruction while preserving high image quality. Real-time 3D imaging using the direct inversion (DI) method spans 7.3 to 1.26 frames per second for datasets of 350 3 to 928 3 voxels, respectively. In addition to the real-time DI preview, the library also provides an efficient implementation of the Gerchberg-Papoulis algorithm: 100 iterations require less than 25 s, including host–GPU data transfers, to obtain a high-quality 3D reconstruction from a dataset of 928 3 voxels. To facilitate broader adoption of our work within the scientific community, we provide our software as a compiled dynamic-link library (DLL) publicly available on GitHub together with its source code.
- 29 June 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (8) , 4390-4403
Wide-field, real-time limited-angle optical diffraction tomography using massively parallel data processing
We present a GPU-accelerated reconstruction framework enabling real-time imaging in limited-angle optical diffraction tomography (LaODT). The implementation leverages massively parallel computing to achieve fast and efficient volumetric reconstruction while preserving high image quality. Real-time 3D imaging using the direct inversion (DI) method spans 7.3 to 1.26 frames per second for datasets of 350 3 to 928 3 voxels, respectively. In addition to the real-time DI preview, the library also provides an efficient implementation of the Gerchberg-Papoulis algorithm: 100 iterations require less than 25 s, including host–GPU data transfers, to obtain a high-quality 3D reconstruction from a dataset of 928 3 voxels. To facilitate broader adoption of our work within the scientific community, we provide our software as a compiled dynamic-link library (DLL) publicly available on GitHub together with its source code.
- Open Access
- 19 November 2025
- Published by Springer Nature in Behavior Research Methods
- Vol. 58 (1) , 2
The best fixation target revisited: New insights from retinal eye tracking
In many tasks, participants are instructed to fixate a target. While maintaining fixation, the eyes nonetheless make small fixational eye movements, such as microsaccades and drift. Previous work has examined the effect of fixation point design on fixation stability and the amount and spatial extent of fixational eye movements. However, much of this work used video-based eye trackers, which have insufficient resolution and suffer from artefacts that make them unsuitable for this topic of study. Here, we therefore use a retinal eye tracker, which offers superior resolution and does not suffer from the same artifacts to reexamine what fixation point design minimizes fixational eye movements. Participants were shown five fixation targets in two target polarity conditions, while the overall spatial spread of their gaze position during fixation, as well as their microsaccades and fixational drift, were examined. We found that gaze was more stable for white-on-black than black-on-grey fixation targets. Gaze was also more stable (lower spatial spread, microsaccade, and drift displacement) for fixation targets with a small central feature but these targets also yielded higher microsaccade rates than larger fixation targets without such a small central feature. In conclusion, there is not a single best fixation target that minimizes all aspects of fixational eye movements. Instead, if one wishes to optimize for minimal spatial spread of the gaze position, microsaccade or drift displacements, we recommend using a target with a small central feature. If one instead wishes to optimize for the lowest microsaccade rate, we recommend using a larger target without a small central feature.
- 19 November 2025
- Published by Springer Nature in Behavior Research Methods
- Vol. 58 (1) , 2
Open AccessThe best fixation target revisited: New insights from retinal eye tracking
In many tasks, participants are instructed to fixate a target. While maintaining fixation, the eyes nonetheless make small fixational eye movements, such as microsaccades and drift. Previous work has examined the effect of fixation point design on fixation stability and the amount and spatial extent of fixational eye movements. However, much of this work used video-based eye trackers, which have insufficient resolution and suffer from artefacts that make them unsuitable for this topic of study. Here, we therefore use a retinal eye tracker, which offers superior resolution and does not suffer from the same artifacts to reexamine what fixation point design minimizes fixational eye movements. Participants were shown five fixation targets in two target polarity conditions, while the overall spatial spread of their gaze position during fixation, as well as their microsaccades and fixational drift, were examined. We found that gaze was more stable for white-on-black than black-on-grey fixation targets. Gaze was also more stable (lower spatial spread, microsaccade, and drift displacement) for fixation targets with a small central feature but these targets also yielded higher microsaccade rates than larger fixation targets without such a small central feature. In conclusion, there is not a single best fixation target that minimizes all aspects of fixational eye movements. Instead, if one wishes to optimize for minimal spatial spread of the gaze position, microsaccade or drift displacements, we recommend using a target with a small central feature. If one instead wishes to optimize for the lowest microsaccade rate, we recommend using a larger target without a small central feature.
- Open Access
- 30 October 2025
- Published by Springer Nature in Behavior Research Methods
- Vol. 57 (12) , 1-9
Do eye trackers estimate eyeball rotation? The relationship between tracked eye image feature and estimated saccadic waveform
The eyeball is not rigid and deforms during saccades. As a consequence, the saccade waveform recorded by an eye tracker may depend on which structure of the eye is used to estimate eyeball rotation. Here, we systematically describe and compare signals co-recorded from the retina, the cornea (corneal reflection, CR), the pupil, and the lens (fourth Purkinje reflection, P4) during saccades. We found that several commonly used parameters for saccade characterization differ systematically across the signals. For instance, saccades in the retinal signal had earlier onsets compared to saccades in the pupil and the P4 signals. The retinal signal had the smallest saccade amplitude and reached the peak saccade velocity earlier compared to the other signals. At the end of saccades, the retinal signal came to a stop faster than the other signals. We discuss possible explanations that may account for the relationship between the retinal signal and the other signals.
- 30 October 2025
- Published by Springer Nature in Behavior Research Methods
- Vol. 57 (12) , 1-9
Open AccessDo eye trackers estimate eyeball rotation? The relationship between tracked eye image feature and estimated saccadic waveform
The eyeball is not rigid and deforms during saccades. As a consequence, the saccade waveform recorded by an eye tracker may depend on which structure of the eye is used to estimate eyeball rotation. Here, we systematically describe and compare signals co-recorded from the retina, the cornea (corneal reflection, CR), the pupil, and the lens (fourth Purkinje reflection, P4) during saccades. We found that several commonly used parameters for saccade characterization differ systematically across the signals. For instance, saccades in the retinal signal had earlier onsets compared to saccades in the pupil and the P4 signals. The retinal signal had the smallest saccade amplitude and reached the peak saccade velocity earlier compared to the other signals. At the end of saccades, the retinal signal came to a stop faster than the other signals. We discuss possible explanations that may account for the relationship between the retinal signal and the other signals.
- Open Access
- 3 July 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (8) , 3027-3046
Wide-field quantitative micro-elastography of freshly excised human prostate
Prostate cancer is a significant global health issue. To advance diagnostic and treatment procedures, such as image-guided needle biopsy, optical imaging methods offering high spatial resolution have been proposed. Optical coherence tomography (OCT) allows for detailed visualization of prostate microarchitecture in three dimensions; however, it does not reliably differentiate tumors from surrounding healthy tissue. In this study, we use wide-field quantitative micro-elastography (QME) to image the micro-scale mechanical properties of freshly excised human prostate to provide additional contrast of tumor, which is known to exhibit increased stiffness. In our approach, we generate volumetric OCT, strain, and elasticity images over a field-of-view (x × y × z) of 46 × 46 × 1 mm3. We validate the contrast obtained in our images through co-registration with standard histology images.
- 3 July 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (8) , 3027-3046
Open AccessWide-field quantitative micro-elastography of freshly excised human prostate
Prostate cancer is a significant global health issue. To advance diagnostic and treatment procedures, such as image-guided needle biopsy, optical imaging methods offering high spatial resolution have been proposed. Optical coherence tomography (OCT) allows for detailed visualization of prostate microarchitecture in three dimensions; however, it does not reliably differentiate tumors from surrounding healthy tissue. In this study, we use wide-field quantitative micro-elastography (QME) to image the micro-scale mechanical properties of freshly excised human prostate to provide additional contrast of tumor, which is known to exhibit increased stiffness. In our approach, we generate volumetric OCT, strain, and elasticity images over a field-of-view (x × y × z) of 46 × 46 × 1 mm3. We validate the contrast obtained in our images through co-registration with standard histology images.
- Open Access
- 14 November 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (12) , 6816-6833
Imaging of prostate micro-architecture using three-dimensional wide-field optical coherence tomography
Prostate cancer is a global health issue that requires new diagnostic methods to provide accurate and precise visualization of prostate tissue on the micro-scale. Such methods have the potential to improve nerve-sparing surgery and to provide image guidance during prostate biopsy. In this feasibility study, we assess the potential of en face three-dimensional wide-field optical coherence tomography (OCT), covering a volumetric imaging field-of-view up to 46 × 46 × 1 mm3, to visualize micro-architecture in 18 freshly excised human prostate specimens. In each case, validation of contrast in OCT images is provided by co-registered wide-field histology images. Using this co-registration, we demonstrate that OCT can distinguish between healthy and cancerous glands at different stages, as well as visualize micro-architecture in the prostate, such as epineurium and perineurium in nerves and the tunica intima and tunica media in blood vessels.
- 14 November 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (12) , 6816-6833
Open AccessImaging of prostate micro-architecture using three-dimensional wide-field optical coherence tomography
Prostate cancer is a global health issue that requires new diagnostic methods to provide accurate and precise visualization of prostate tissue on the micro-scale. Such methods have the potential to improve nerve-sparing surgery and to provide image guidance during prostate biopsy. In this feasibility study, we assess the potential of en face three-dimensional wide-field optical coherence tomography (OCT), covering a volumetric imaging field-of-view up to 46 × 46 × 1 mm3, to visualize micro-architecture in 18 freshly excised human prostate specimens. In each case, validation of contrast in OCT images is provided by co-registered wide-field histology images. Using this co-registration, we demonstrate that OCT can distinguish between healthy and cancerous glands at different stages, as well as visualize micro-architecture in the prostate, such as epineurium and perineurium in nerves and the tunica intima and tunica media in blood vessels.
- 21 October 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (11) , 5971-5988
Near-infrared, wavelength, and illumination scanning holographic tomography
We present a holographic tomography technique in which the projections are acquired using both wavelength and illumination scanning in the near-infrared region. We show how to process the acquired data to obtain correct values of three-dimensional refractive index distributions in both single-wavelength and multi-wavelength data acquisition schemes and how to properly account for the dispersion of the sample. We perform numerical and experimental comparisons of different illumination scenarios to determine the most efficient measurement protocol. We show that the multi-wavelength protocol is advantageous in terms of signal-to-noise ratio and contrast-to-noise ratio over single-wavelength protocols, even for the same number of projections used for reconstructions. Finally, we show that this approach is suitable for providing high-quality refractive index distributions of relatively thick colon cancer samples.
- 21 October 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (11) , 5971-5988
Near-infrared, wavelength, and illumination scanning holographic tomography
We present a holographic tomography technique in which the projections are acquired using both wavelength and illumination scanning in the near-infrared region. We show how to process the acquired data to obtain correct values of three-dimensional refractive index distributions in both single-wavelength and multi-wavelength data acquisition schemes and how to properly account for the dispersion of the sample. We perform numerical and experimental comparisons of different illumination scenarios to determine the most efficient measurement protocol. We show that the multi-wavelength protocol is advantageous in terms of signal-to-noise ratio and contrast-to-noise ratio over single-wavelength protocols, even for the same number of projections used for reconstructions. Finally, we show that this approach is suitable for providing high-quality refractive index distributions of relatively thick colon cancer samples.
- 1 August 2022
- Published by Oxford University Press (OUP) in Reproduction
- Vol. 164 (3) , 83-95
Optical coherence microscopy allows for quality assessment of immature mouse oocytes
: In brief: Optical coherence microscopy is a label-free and non-invasive imaging technique capable of 3D subcellular structure visualization. Here we show that this method allows for quality assessment of immature mouse oocytes based on their chromatin conformation and can be a valuable addition to the toolkit used in assisted reproduction procedures. The success of assisted reproductive technologies, and particularly in vitro maturation, is tightly linked to the quality of oocytes. Therefore, there is a need for robust, reliable, and easy-to-assess biomarkers of oocyte developmental competence. Microscopy techniques visualizing oocyte intracellular structure could provide such biomarkers. However, fluorescence imaging methods, applied frequently in biology and allowing for detailed structural and dynamic studies of single cells, require fluorescent tags to visualize cellular architecture and may cause short- and long-term photo-damage. On the other hand, traditional light microscopy, although relatively non-invasive, does not provide detailed structural information. Optical coherence microscopy (OCM) is a promising alternative, as it does not require sample pre-processing or labelling and can provide 3D images of intracellular structures. Here we applied OCM to assess the chromatin conformation of immature mouse oocytes, a feature that corresponds with their transcriptional status and developmental competence and cannot be examined by traditional light microscopy. We showed that OCM distinguished oocytes with so-called non-surrounded nucleoli (NSN) and surrounded nucleoli (SN) chromatin conformation with very high sensitivity and specificity and that OCM scanning did not decrease the quality of oocytes. Finally, we cross-referenced OCM data with the oocyte ability to undergo normal nuclear and cytoplasmic maturation and proven that indeed oocytes scored with OCM as NSN mature less effectively than oocytes scored as SN. Our results suggest that OCM may be a valuable addition to the imaging toolkit used in assisted reproduction procedures.
- 1 August 2022
- Published by Oxford University Press (OUP) in Reproduction
- Vol. 164 (3) , 83-95
Optical coherence microscopy allows for quality assessment of immature mouse oocytes
: In brief: Optical coherence microscopy is a label-free and non-invasive imaging technique capable of 3D subcellular structure visualization. Here we show that this method allows for quality assessment of immature mouse oocytes based on their chromatin conformation and can be a valuable addition to the toolkit used in assisted reproduction procedures. The success of assisted reproductive technologies, and particularly in vitro maturation, is tightly linked to the quality of oocytes. Therefore, there is a need for robust, reliable, and easy-to-assess biomarkers of oocyte developmental competence. Microscopy techniques visualizing oocyte intracellular structure could provide such biomarkers. However, fluorescence imaging methods, applied frequently in biology and allowing for detailed structural and dynamic studies of single cells, require fluorescent tags to visualize cellular architecture and may cause short- and long-term photo-damage. On the other hand, traditional light microscopy, although relatively non-invasive, does not provide detailed structural information. Optical coherence microscopy (OCM) is a promising alternative, as it does not require sample pre-processing or labelling and can provide 3D images of intracellular structures. Here we applied OCM to assess the chromatin conformation of immature mouse oocytes, a feature that corresponds with their transcriptional status and developmental competence and cannot be examined by traditional light microscopy. We showed that OCM distinguished oocytes with so-called non-surrounded nucleoli (NSN) and surrounded nucleoli (SN) chromatin conformation with very high sensitivity and specificity and that OCM scanning did not decrease the quality of oocytes. Finally, we cross-referenced OCM data with the oocyte ability to undergo normal nuclear and cytoplasmic maturation and proven that indeed oocytes scored with OCM as NSN mature less effectively than oocytes scored as SN. Our results suggest that OCM may be a valuable addition to the imaging toolkit used in assisted reproduction procedures.
- 22 October 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (21) , 5377-5380
Accurate calibration of beam trajectories in scanning optical imaging systems
We present a calibration method for finding the coordinates of points in the trajectory of the scanning beam in flying-spot imaging devices. Our method is based on laterally translating the field of view on the imaging object plane by introducing additional beam deflections. We show that laterally translating the field of view provides a series of images whose relative translations are equal to the distances between the points in the scanning pattern to be calibrated. We show how these distances are mapped to the coordinates of the trajectory points. As an example, we demonstrate the calibration of the scanning patterns in an optical system with two independent microelectromechanical system based scanners. Our method profits from a large collection of distance measurements to find the trajectory coordinates, thereby minimizing the effect of random sources of uncertainty in the positions of points in the scanning pattern. We have found that we are capable of finding the coordinates of points in the scanning patterns with accuracy greater than the optical resolution of the imaging system.
- 22 October 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (21) , 5377-5380
Accurate calibration of beam trajectories in scanning optical imaging systems
We present a calibration method for finding the coordinates of points in the trajectory of the scanning beam in flying-spot imaging devices. Our method is based on laterally translating the field of view on the imaging object plane by introducing additional beam deflections. We show that laterally translating the field of view provides a series of images whose relative translations are equal to the distances between the points in the scanning pattern to be calibrated. We show how these distances are mapped to the coordinates of the trajectory points. As an example, we demonstrate the calibration of the scanning patterns in an optical system with two independent microelectromechanical system based scanners. Our method profits from a large collection of distance measurements to find the trajectory coordinates, thereby minimizing the effect of random sources of uncertainty in the positions of points in the scanning pattern. We have found that we are capable of finding the coordinates of points in the scanning patterns with accuracy greater than the optical resolution of the imaging system.
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 73
Zero-latency retinal movement tracker with high spatial and temporal resolution
SPIE Digital Library Proceedings
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 73
Zero-latency retinal movement tracker with high spatial and temporal resolution
SPIE Digital Library Proceedings