Kurt Fortwaengler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kurt Fortwaengler has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Christopher G. Parkin
CGParkin Communications, Inc., Henderson, NV, USA
2 shared publications Enrique Campos-Náñez
Center for Diabetes Technology, University of Virginia, Charlottesville, VA, USA
2 shared publicationsKurt Neeser
Laser Analytica, Lörrach, Germany
1 shared publicationMarc D. Breton
Center for Diabetes Technology, University of Virginia, Charlottesville, VA, USA
1 shared publication- Marc D. Breton
Center for Diabetes Technology, University of Virginia, Charlottesville, VA, USA
1 shared publication Monika Neumann
Laser Analytica, Lörrach, Germany
1 shared publication
Latest Publications
- Open Access
- 26 September 2017
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 12 (2) , 318-324
The Financial Impact of Inaccurate Blood Glucose Monitoring Systems
Objective: An in silico study of type 1 diabetes (T1DM) patients utilized the UVA-PADOVA Type 1 Diabetes Simulator to assess the effect of patient blood glucose monitoring (BGM) system accuracy on clinical outcomes. We applied these findings to assess the financial impact of BGM system inaccuracy. Methods: The study included 43 BGM systems previously assessed for accuracy according to ISO 15197:2003 and ISO 15197:2013 criteria. Glycemic responses for the 100 in silico adult T1DM subjects were generated, using each meter. Changes in estimated HbA1c, severe hypoglycemic events, and health care resource utilization were computed for each simulation. The HbA1c Translator modeling approach was used to calculate the financial impact of these changes. Results: The average cost of inaccuracy associated with the entire group of BGM systems was £155 per patient year (PPY). The average additional cost of BGM systems not meeting the ISO 15197:2003 standard was an estimated £178 PPY more than an average system that fulfills the standard and an estimated £235 PPY more than an average system that appears to meet the ISO 15197:2013 standard. Conclusion: There is a clear relationship between BGM system accuracy and cost, with the highest costs being associated with BGM systems not meeting the ISO 15197:2003 standard. Lower costs are associated with systems meeting the ISO 15197:2013 system accuracy criteria. Using BGM systems that meet the system accuracy criteria of the ISO 15197:2013 standard can help reduce the clinical and financial consequences associated with inaccuracy of BGM devices.
- 26 September 2017
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 12 (2) , 318-324
Open AccessThe Financial Impact of Inaccurate Blood Glucose Monitoring Systems
Objective: An in silico study of type 1 diabetes (T1DM) patients utilized the UVA-PADOVA Type 1 Diabetes Simulator to assess the effect of patient blood glucose monitoring (BGM) system accuracy on clinical outcomes. We applied these findings to assess the financial impact of BGM system inaccuracy. Methods: The study included 43 BGM systems previously assessed for accuracy according to ISO 15197:2003 and ISO 15197:2013 criteria. Glycemic responses for the 100 in silico adult T1DM subjects were generated, using each meter. Changes in estimated HbA1c, severe hypoglycemic events, and health care resource utilization were computed for each simulation. The HbA1c Translator modeling approach was used to calculate the financial impact of these changes. Results: The average cost of inaccuracy associated with the entire group of BGM systems was £155 per patient year (PPY). The average additional cost of BGM systems not meeting the ISO 15197:2003 standard was an estimated £178 PPY more than an average system that fulfills the standard and an estimated £235 PPY more than an average system that appears to meet the ISO 15197:2013 standard. Conclusion: There is a clear relationship between BGM system accuracy and cost, with the highest costs being associated with BGM systems not meeting the ISO 15197:2003 standard. Lower costs are associated with systems meeting the ISO 15197:2013 system accuracy criteria. Using BGM systems that meet the system accuracy criteria of the ISO 15197:2013 standard can help reduce the clinical and financial consequences associated with inaccuracy of BGM devices.
- Open Access
- 1 June 2017
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 11 (6) , 1187-1195
Clinical Impact of Blood Glucose Monitoring Accuracy: An In-Silico Study
Patients with diabetes rely on blood glucose (BG) monitoring devices to manage their condition. As some self-monitoring devices are becoming more and more accurate, it becomes critical to understand the relationship between system accuracy and clinical outcomes, and the potential benefits of analytical accuracy. We conducted a 30-day in-silico study in type 1 diabetes mellitus (T1DM) patients using continuous subcutaneous insulin infusion (CSII) therapy and a variety of BG meters, using the FDA-approved University of Virginia (UVA)/Padova Type 1 Simulator. We used simulated meter models derived from the published characteristics of 43 commercial meters. By controlling random events in each parallel run, we isolated the differences in clinical performance that are directly associated with the meter characteristics. A meter’s systematic bias has a significant and inverse effect on HbA1c (P < .01), while also affecting the number of severe hypoglycemia events. On the other hand, error, defined as the fraction of measurements beyond 5% of the true value, is a predictor of severe hypoglycemia events (P < .01), but in the absence of bias has a nonsignificant effect on average glycemia (HbA1c). Both bias and error have significant effects on total daily insulin (TDI) and the number of necessary glucose measurements per day (P < .01). Furthermore, these relationships can be accurately modeled using linear regression on meter bias and error. Two components of meter accuracy, bias and error, clearly affect clinical outcomes. While error has little effect on HbA1c, it tends to increase episodes of severe hypoglycemia. Meter bias has significant effects on all considered metrics: a positive systemic bias will reduce HbA1c, but increase the number of severe hypoglycemia attacks, TDI use, and number of fingersticks per day.
- 1 June 2017
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 11 (6) , 1187-1195
Open AccessClinical Impact of Blood Glucose Monitoring Accuracy: An In-Silico Study
Patients with diabetes rely on blood glucose (BG) monitoring devices to manage their condition. As some self-monitoring devices are becoming more and more accurate, it becomes critical to understand the relationship between system accuracy and clinical outcomes, and the potential benefits of analytical accuracy. We conducted a 30-day in-silico study in type 1 diabetes mellitus (T1DM) patients using continuous subcutaneous insulin infusion (CSII) therapy and a variety of BG meters, using the FDA-approved University of Virginia (UVA)/Padova Type 1 Simulator. We used simulated meter models derived from the published characteristics of 43 commercial meters. By controlling random events in each parallel run, we isolated the differences in clinical performance that are directly associated with the meter characteristics. A meter’s systematic bias has a significant and inverse effect on HbA1c (P < .01), while also affecting the number of severe hypoglycemia events. On the other hand, error, defined as the fraction of measurements beyond 5% of the true value, is a predictor of severe hypoglycemia events (P < .01), but in the absence of bias has a nonsignificant effect on average glycemia (HbA1c). Both bias and error have significant effects on total daily insulin (TDI) and the number of necessary glucose measurements per day (P < .01). Furthermore, these relationships can be accurately modeled using linear regression on meter bias and error. Two components of meter accuracy, bias and error, clearly affect clinical outcomes. While error has little effect on HbA1c, it tends to increase episodes of severe hypoglycemia. Meter bias has significant effects on all considered metrics: a positive systemic bias will reduce HbA1c, but increase the number of severe hypoglycemia attacks, TDI use, and number of fingersticks per day.
- Open Access
- 20 August 2016
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 11 (2) , 315-323
Description of a New Predictive Modeling Approach That Correlates the Risk and Associated Cost of Well-Defined Diabetes-Related Complications With Changes in Glycated Hemoglobin (HbA1c)
The modeling approach described here is designed to support the development of spreadsheet-based simple predictive models. It is based on 3 pillars: association of the complications with HbA1c changes, incidence of the complications, and average cost per event of the complication. For each pillar, the goal of the analysis was (1) to find results for a large diversity of populations with a focus on countries/regions, diabetes type, age, diabetes duration, baseline HbA1c value, and gender; (2) to assess the range of incidences and associations previously reported. Unlike simple predictive models, which mostly are based on only 1 source of information for each of the pillars, we conducted a comprehensive, systematic literature review. Each source found was thoroughly reviewed and only sources meeting quality expectations were considered. The approach allows avoidance of unintended use of extreme data. The user can utilize (1) one of the found sources, (2) the found range as validation for the found figures, or (3) the average of all found publications for an expedited estimate. The modeling approach is intended for use in average insulin-treated diabetes populations in which the baseline HbA1c values are within an average range (6.5% to 11.5%); it is not intended for use in individuals or unique diabetes populations (eg, gestational diabetes). Because the modeling approach only considers diabetes-related complications that are positively associated with HbA1c decreases, the costs of negatively associated complications (eg, severe hypoglycemic events) must be calculated separately.
- 20 August 2016
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 11 (2) , 315-323
Open AccessDescription of a New Predictive Modeling Approach That Correlates the Risk and Associated Cost of Well-Defined Diabetes-Related Complications With Changes in Glycated Hemoglobin (HbA1c)
The modeling approach described here is designed to support the development of spreadsheet-based simple predictive models. It is based on 3 pillars: association of the complications with HbA1c changes, incidence of the complications, and average cost per event of the complication. For each pillar, the goal of the analysis was (1) to find results for a large diversity of populations with a focus on countries/regions, diabetes type, age, diabetes duration, baseline HbA1c value, and gender; (2) to assess the range of incidences and associations previously reported. Unlike simple predictive models, which mostly are based on only 1 source of information for each of the pillars, we conducted a comprehensive, systematic literature review. Each source found was thoroughly reviewed and only sources meeting quality expectations were considered. The approach allows avoidance of unintended use of extreme data. The user can utilize (1) one of the found sources, (2) the found range as validation for the found figures, or (3) the average of all found publications for an expedited estimate. The modeling approach is intended for use in average insulin-treated diabetes populations in which the baseline HbA1c values are within an average range (6.5% to 11.5%); it is not intended for use in individuals or unique diabetes populations (eg, gestational diabetes). Because the modeling approach only considers diabetes-related complications that are positively associated with HbA1c decreases, the costs of negatively associated complications (eg, severe hypoglycemic events) must be calculated separately.