Ali Tarighatnia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ali Tarighatnia has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Nader Djalal Nader
Department of Anesthesiology, Jacobs School of Medicine and Biomedical Sciences University at Buffalo Buffalo New York USA
5 shared publications A. H. Mohammadalian
Interventional Cardiology Unit, Aalinasab Hospital, Tabriz, Iran
2 shared publicationsEvin Koleini
Department of Anesthesiology, VA Western NY Healthcare System, Buffalo, NY, USA
2 shared publicationsM. Ghojazadeh
Liver and Gastrointestinal Disease Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
2 shared publicationsA. Farajollahi
Tabriz University of Medical Sciences, Tabriz, Iran
1 shared publicationA. R. Farajollahi
Department of Medical Physics, Tabriz University of Medical Sciences, Tabriz, Iran
1 shared publication
Latest Publications
- 23 March 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 182 (2) , 200-207
AN ANALYSIS OF OPERATING PHYSICIAN AND PATIENT RADIATION EXPOSURE DURING RADIAL CORONARY ANGIOPLASTIES
The objective of this study was to evaluate radiation exposure levels in conjunction with operator dose implemented, patient vascular characteristics, and other technical angiographic parameters. In total, 756 radial coronary angioplasties were evaluated in a major metropolitan general hospital in Tabriz, Iran. The classification of coronary lesions was based on the ACC/AHA system. One interventional cardiologist performed all of the procedures using a single angiography unit. The mean kerma-area product and mean cumulative dose for all cases was 5081 μGy m2 and 814.44 mGy, respectively. Average times of 26.16 and 9.1 min were recorded for the overall procedure and fluoroscopy, respectively. A strong correlation was demonstrated between types of lesions, number of stents and vessels treated in relation to physician radiation exposure. It was determined that operator radiation exposure levels for percutaneous coronary interventions lesions (complex) were higher than that of simple and moderate lesions. In addition, operator radiation exposure levels increased with the treatment of more coronary vessels and implementation of additional stents.
- 23 March 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 182 (2) , 200-207
AN ANALYSIS OF OPERATING PHYSICIAN AND PATIENT RADIATION EXPOSURE DURING RADIAL CORONARY ANGIOPLASTIES
The objective of this study was to evaluate radiation exposure levels in conjunction with operator dose implemented, patient vascular characteristics, and other technical angiographic parameters. In total, 756 radial coronary angioplasties were evaluated in a major metropolitan general hospital in Tabriz, Iran. The classification of coronary lesions was based on the ACC/AHA system. One interventional cardiologist performed all of the procedures using a single angiography unit. The mean kerma-area product and mean cumulative dose for all cases was 5081 μGy m2 and 814.44 mGy, respectively. Average times of 26.16 and 9.1 min were recorded for the overall procedure and fluoroscopy, respectively. A strong correlation was demonstrated between types of lesions, number of stents and vessels treated in relation to physician radiation exposure. It was determined that operator radiation exposure levels for percutaneous coronary interventions lesions (complex) were higher than that of simple and moderate lesions. In addition, operator radiation exposure levels increased with the treatment of more coronary vessels and implementation of additional stents.
- 3 January 2018
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 27 (5) , e80-e85
Vertebrobasilar Artery Stroke as the Heralding Sign of Systemic Lupus Erythematosus
- 3 January 2018
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 27 (5) , e80-e85
Vertebrobasilar Artery Stroke as the Heralding Sign of Systemic Lupus Erythematosus
- 3 November 2017
- Published by Springer Nature in Herz
- Vol. 44 (4) , 330-335
Radiation exposure levels according to vascular access sites during PCI
We previously showed that using the radial artery access site as opposed to the femoral artery site decreases the radiation exposure of patients during coronary artery interventions. The objective of this study was to compare radiation exposure levels of the operating physician during coronary interventions when incorporating both radial and femoral artery approaches.
- 3 November 2017
- Published by Springer Nature in Herz
- Vol. 44 (4) , 330-335
Radiation exposure levels according to vascular access sites during PCI
We previously showed that using the radial artery access site as opposed to the femoral artery site decreases the radiation exposure of patients during coronary artery interventions. The objective of this study was to compare radiation exposure levels of the operating physician during coronary interventions when incorporating both radial and femoral artery approaches.
- 17 July 2017
- Published by Springer Nature in Herz
- Vol. 43 (6) , 535-542
Operator radiation exposure during transradial coronary angiography
The right radial artery has gained popularity as the preferred access site for coronary angiography. To save time and limit the radiation exposure of operators and patients, newly designed catheters can be used to access both the right and left coronary arteries. The aim of this study was to compare operator radiation exposure between single-catheter (SCA) and two-catheter approaches (TCA).
- 17 July 2017
- Published by Springer Nature in Herz
- Vol. 43 (6) , 535-542
Operator radiation exposure during transradial coronary angiography
The right radial artery has gained popularity as the preferred access site for coronary angiography. To save time and limit the radiation exposure of operators and patients, newly designed catheters can be used to access both the right and left coronary arteries. The aim of this study was to compare operator radiation exposure between single-catheter (SCA) and two-catheter approaches (TCA).
- Open Access
- 1 January 2017
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 18 (4) , 298-303
Beam projections and radiation exposure in transradial and transfemoral approaches during coronary angiography
We aimed to compare the operator and patient radiation exposure in standard projections during elective diagnostic coronary angiography procedures via transradial (TRA) versus transfemoral (TFA) approaches. In this analytical cross-sectional study, a total of 202 consecutive patients who were candidates for diagnostic coronary angiography were randomized to undergo the procedure via TFA or TRA approaches (101 in each group). Patients with abnormal Allen test and history of coronary artery bypass surgery, valvular heart disease, and unsuccessful coronary angiography were excluded from the study. A single operator performed all of the procedures using a single angiography system. Patient and operator radiation exposure were measured using diamentor and an electronic personal dosimeter, respectively. Each procedure comprised a standardized sequence of projections including four standard views for the left coronary system and two standard views for the right coronary system. Left anterior oblique (LAO) caudal (50°/30°) and right anterior oblique RAO (30°) projections were associated with the highest and lowest patient radiation exposure, respectively. The operator received a significantly higher radiation exposure in the TRA approach for LAO cranial (for both left and right coronary systems) and LAO caudal (for left coronary system) projections during coronary angiography compared with the TFA approach. Though a similar amount of patient radiation exposure in each projection was observed among TFA and TRA groups; LAO cranial and LAO caudal projections were associated with a significantly higher operator radiation exposure in the TRA group. These findings need to be considered when choosing the optimal arterial approach for patients scheduled for coronary angiography.
- 1 January 2017
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 18 (4) , 298-303
Open AccessBeam projections and radiation exposure in transradial and transfemoral approaches during coronary angiography
We aimed to compare the operator and patient radiation exposure in standard projections during elective diagnostic coronary angiography procedures via transradial (TRA) versus transfemoral (TFA) approaches. In this analytical cross-sectional study, a total of 202 consecutive patients who were candidates for diagnostic coronary angiography were randomized to undergo the procedure via TFA or TRA approaches (101 in each group). Patients with abnormal Allen test and history of coronary artery bypass surgery, valvular heart disease, and unsuccessful coronary angiography were excluded from the study. A single operator performed all of the procedures using a single angiography system. Patient and operator radiation exposure were measured using diamentor and an electronic personal dosimeter, respectively. Each procedure comprised a standardized sequence of projections including four standard views for the left coronary system and two standard views for the right coronary system. Left anterior oblique (LAO) caudal (50°/30°) and right anterior oblique RAO (30°) projections were associated with the highest and lowest patient radiation exposure, respectively. The operator received a significantly higher radiation exposure in the TRA approach for LAO cranial (for both left and right coronary systems) and LAO caudal (for left coronary system) projections during coronary angiography compared with the TFA approach. Though a similar amount of patient radiation exposure in each projection was observed among TFA and TRA groups; LAO cranial and LAO caudal projections were associated with a significantly higher operator radiation exposure in the TRA group. These findings need to be considered when choosing the optimal arterial approach for patients scheduled for coronary angiography.