Jaber Mamaghanian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jaber Mamaghanian has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Hamid Reza Razeghi
School of Civil Engineering, Iran University of Science and Technology (IUST), Tehran, Iran
8 shared publications - Masoud Ebrahimi Derakhshan
School of Civil Engineering, Iran University of Science and Technology, Tehran, Iran
4 shared publications B.V.S. Viswanadham
3 shared publications- Mehrab Ramzani
School of Civil Engineering, Iran University of Science and Technology, Tehran, Iran
2 shared publications - Ali Noorzad
Faculty of Civil, Water and Environmental Engineering, Shahid Beheshti University, Tehran, Iran
1 shared publication - Amirhossein Saffari
Amirkabir University of Technology, Tehran, Iran
1 shared publication
Latest Publications
- 18 June 2026
- Published by Taylor & Francis in Geomechanics and Geoengineering
- Vol. 21 (6) , 1632-1644
A comparative analysis of gradient boosting algorithms for predicting the shear stress of root-reinforced unsaturated soil
- 18 June 2026
- Published by Taylor & Francis in Geomechanics and Geoengineering
- Vol. 21 (6) , 1632-1644
A comparative analysis of gradient boosting algorithms for predicting the shear stress of root-reinforced unsaturated soil
- 24 September 2025
- Published by Springer Nature in Geotechnical and Geological Engineering
- Vol. 43 (8) , 1-9
Data-Driven Modeling of Additional Root-Soil Stress in Unsaturated Clayey Silt at Varying Strain Levels
- 24 September 2025
- Published by Springer Nature in Geotechnical and Geological Engineering
- Vol. 43 (8) , 1-9
Data-Driven Modeling of Additional Root-Soil Stress in Unsaturated Clayey Silt at Varying Strain Levels
- 6 August 2022
- Published by Springer Nature in Indian Geotechnical Journal
- Vol. 52 (6) , 1464-1475
A Finite Element Study on Hydro-Thermo-Mechanical Behaviour of Bioreactor Landfills
- 6 August 2022
- Published by Springer Nature in Indian Geotechnical Journal
- Vol. 52 (6) , 1464-1475
A Finite Element Study on Hydro-Thermo-Mechanical Behaviour of Bioreactor Landfills
- 1 October 2019
- Published by Elsevier in Geotextiles and Geomembranes
- Vol. 47 (5) , 671-684
Centrifuge and numerical model studies on the behaviour of geogrid reinforced soil walls with marginal backfills with and without geocomposite layers
- 1 October 2019
- Published by Elsevier in Geotextiles and Geomembranes
- Vol. 47 (5) , 671-684
Centrifuge and numerical model studies on the behaviour of geogrid reinforced soil walls with marginal backfills with and without geocomposite layers
- 1 August 2019
- Published by Emerald Publishing in Geosynthetics International
- Vol. 26 (4) , 371-387
Centrifuge model studies on geocomposite reinforced soil walls subjected to seepage
This paper investigates the effect of geocomposite layers (as an internal drainage system) and a chimney sand drain (as an external drainage system) on the performance of reinforced soil walls with panel facing and marginal backfill. Four models subjected to seepage simulating a rising groundwater surface were tested at 40 gravities using a 4.5 m radius large beam centrifuge. In this study, geocomposite layers played a dual function of drainage and reinforcement. The behavior of wall models was monitored using displacement and pore water pressure transducers during centrifuge tests. An image analysis technique was also used to measure displacement and strain fields. A geogrid reinforced soil wall with no drainage system experienced catastrophic failure at the onset of seepage. Provision of geocomposite layers at the bottom portion of the wall improved the wall behavior. Further, including geocomposite layers up to the mid-height of the wall resulted in superior performance compared to geogrid-reinforced soil walls. The model with the chimney sand drain experienced piping failure at the toe of the wall. The performance of reinforced soil walls with geocomposite layers was found to be superior to the geogrid reinforced soil walls with the chimney drain.
- 1 August 2019
- Published by Emerald Publishing in Geosynthetics International
- Vol. 26 (4) , 371-387
Centrifuge model studies on geocomposite reinforced soil walls subjected to seepage
This paper investigates the effect of geocomposite layers (as an internal drainage system) and a chimney sand drain (as an external drainage system) on the performance of reinforced soil walls with panel facing and marginal backfill. Four models subjected to seepage simulating a rising groundwater surface were tested at 40 gravities using a 4.5 m radius large beam centrifuge. In this study, geocomposite layers played a dual function of drainage and reinforcement. The behavior of wall models was monitored using displacement and pore water pressure transducers during centrifuge tests. An image analysis technique was also used to measure displacement and strain fields. A geogrid reinforced soil wall with no drainage system experienced catastrophic failure at the onset of seepage. Provision of geocomposite layers at the bottom portion of the wall improved the wall behavior. Further, including geocomposite layers up to the mid-height of the wall resulted in superior performance compared to geogrid-reinforced soil walls. The model with the chimney sand drain experienced piping failure at the toe of the wall. The performance of reinforced soil walls with geocomposite layers was found to be superior to the geogrid reinforced soil walls with the chimney drain.
- 11 July 2018
- Published by Taylor & Francis
- p. 1211-1216
Behaviour of geogrid reinforced soil walls with marginal backfills with and without chimney drain in a geotechnical centrifuge
This paper is aimed to study the effect of chimney drain on the performance of geogrid reinforced soil walls with marginal backfills. Three centrifuge model tests were performed using a 4.5 m radius beam centrifuge facility available at IIT Bombay at 40 g. All models were subjected to seepage simulating rising ground water condition. Marginal soil type, the wall height, reinforcement length, and spacing and facing type was kept constant. Two types of chimney drain were used in this study including chimney nonwoven geotextile drain and chimney sand drain. Pore water pressure and displacement transducers were used to monitor the wall behaviour during centrifuge tests. Moreover, image analysis technique was used to obtain the displacement field of the models. The geogrid reinforced soil wall without chimney drain experienced global stability failure soon after inducing seepage. Application of chimney geotextile layer could not improve the wall behaviour but caused a delay on the occurrence of global stability failure. On the other hand, the application of chimney sand drain improved the wall behaviour effectively. This chapter describes the effect of chimney drain on the performance of geogrid reinforced soil walls with marginal backfills. It presents the effects of chimney nonwoven geotextile drain and chimney sand drain systems on the geogrid reinforced soil wall behaviour. The chapter also presents the deformation behaviour of three geogrid reinforced soil walls through centrifuge model tests at 40 g. Two types of geosynthetic materials were including geogrid as reinforcement and nonwoven geotextile as chimney geotextile drain. These materials were modeled based on the scaling consideration of geosynthetic reinforced soil walls in centrifuge under seepage condition. Application of chimney geotextile layer could not improve the wall behaviour but caused a delay on the occurrence of global stability failure. The application of chimney sand drain improved the wall behaviour effectively. In order to simulate seepage condition in a geotechnical centrifuge, the dimensional analysis of seepage flow, permeability of backfill and transmissivity of geotextile drain layer are required.
- 11 July 2018
- Published by Taylor & Francis
- p. 1211-1216
Behaviour of geogrid reinforced soil walls with marginal backfills with and without chimney drain in a geotechnical centrifuge
This paper is aimed to study the effect of chimney drain on the performance of geogrid reinforced soil walls with marginal backfills. Three centrifuge model tests were performed using a 4.5 m radius beam centrifuge facility available at IIT Bombay at 40 g. All models were subjected to seepage simulating rising ground water condition. Marginal soil type, the wall height, reinforcement length, and spacing and facing type was kept constant. Two types of chimney drain were used in this study including chimney nonwoven geotextile drain and chimney sand drain. Pore water pressure and displacement transducers were used to monitor the wall behaviour during centrifuge tests. Moreover, image analysis technique was used to obtain the displacement field of the models. The geogrid reinforced soil wall without chimney drain experienced global stability failure soon after inducing seepage. Application of chimney geotextile layer could not improve the wall behaviour but caused a delay on the occurrence of global stability failure. On the other hand, the application of chimney sand drain improved the wall behaviour effectively. This chapter describes the effect of chimney drain on the performance of geogrid reinforced soil walls with marginal backfills. It presents the effects of chimney nonwoven geotextile drain and chimney sand drain systems on the geogrid reinforced soil wall behaviour. The chapter also presents the deformation behaviour of three geogrid reinforced soil walls through centrifuge model tests at 40 g. Two types of geosynthetic materials were including geogrid as reinforcement and nonwoven geotextile as chimney geotextile drain. These materials were modeled based on the scaling consideration of geosynthetic reinforced soil walls in centrifuge under seepage condition. Application of chimney geotextile layer could not improve the wall behaviour but caused a delay on the occurrence of global stability failure. The application of chimney sand drain improved the wall behaviour effectively. In order to simulate seepage condition in a geotechnical centrifuge, the dimensional analysis of seepage flow, permeability of backfill and transmissivity of geotextile drain layer are required.
- 1 October 2017
- Published by Elsevier in Geotextiles and Geomembranes
- Vol. 45 (5) , 430-446
Centrifuge model study on geogrid reinforced soil walls with marginal backfills with and without chimney sand drain
- 1 October 2017
- Published by Elsevier in Geotextiles and Geomembranes
- Vol. 45 (5) , 430-446
Centrifuge model study on geogrid reinforced soil walls with marginal backfills with and without chimney sand drain