Alister J. Tencate
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alister J. Tencate has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- John H. Kalivas
Idaho State University
3 shared publications - A. Gee
Department of Physics, Northern Illinois University, DeKalb, Illinois 60115, USA
1 shared publication - Afnan Al Marzouk
Northern Illinois University
1 shared publication Alexander J. White
Department of Physics and Optical Engineering, Rose-Hulman Institute of Technology, Terre Huate, IN 47803, USA
1 shared publicationB. Erdelyi
Department of Physics, Northern Illinois University, DeKalb, Illinois 60115, USA
1 shared publicationBenjamin T. Carlson
1 shared publication
Latest Publications
- Open Access
- 12 March 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (3)
Dynamic evolution of ultracold electron beams from nanostructured cathodes
Dynamic Coulomb expansion of dense, nonuniform particle beamlets can lead to causticlike formations in the charge density profile of the resultant beam. Such features only occur for cold beams where thermal diffusion of the particles is minimized. These phenomena have been observed experimentally for select cases with ion beams but not yet for electron beams as the electron dynamics occur over far faster timescales. We simulate the interaction of electron bunches while varying the initial transverse temperature and density profiles to determine the thresholds that characterize this pattern formation. Furthermore, we extend the simulations to geometric arrangements that are more pertinent to the nanotip cathode application and consider the effects of asymmetries and the impact of a low-density halo on the overall process. The simulations are conducted using a previously documented high-fidelity algorithm for collisional particle dynamics. These studies identify the temperature and density thresholds required for caustic formation and provide guidance for optimizing the design of nanoscale structured cathodes. We also demonstrate that the correlation between the final density patterns and the underlying beam parameters enables a virtual diagnostic tool for measuring ultralow emittance beams solely based on a transverse charge density profile.
- 12 March 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (3)
Open AccessDynamic evolution of ultracold electron beams from nanostructured cathodes
Dynamic Coulomb expansion of dense, nonuniform particle beamlets can lead to causticlike formations in the charge density profile of the resultant beam. Such features only occur for cold beams where thermal diffusion of the particles is minimized. These phenomena have been observed experimentally for select cases with ion beams but not yet for electron beams as the electron dynamics occur over far faster timescales. We simulate the interaction of electron bunches while varying the initial transverse temperature and density profiles to determine the thresholds that characterize this pattern formation. Furthermore, we extend the simulations to geometric arrangements that are more pertinent to the nanotip cathode application and consider the effects of asymmetries and the impact of a low-density halo on the overall process. The simulations are conducted using a previously documented high-fidelity algorithm for collisional particle dynamics. These studies identify the temperature and density thresholds required for caustic formation and provide guidance for optimizing the design of nanoscale structured cathodes. We also demonstrate that the correlation between the final density patterns and the underlying beam parameters enables a virtual diagnostic tool for measuring ultralow emittance beams solely based on a transverse charge density profile.
- Open Access
- 24 May 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (5) , 054601
Differential algebraic fast multipole-accelerated boundary element method for nonlinear beam dynamics in arbitrary enclosures
A novel method is developed to take into account realistic boundary conditions in intense nonlinear beam dynamics. The algorithm consists of three main ingredients: the boundary element method that provides a solution for the discretized reformulation of the Poisson equation as boundary integrals; a novel fast multipole method developed for accurate and efficient computation of Coulomb potentials and forces; and differential algebraic methods, which form the numerical structures that enable and hold together the different components. The fast multipole method, without any modifications, also accelerates the solution of intertwining linear systems of equations for further efficiency enhancements. The resulting algorithm scales linearly with the number of particles , as with the number of boundary elements , and, therefore, establishes an accurate and efficient method for intense beam dynamics simulations in arbitrary enclosures. Its performance is illustrated with three different cases and structures of practical interest.- 24 May 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (5) , 054601
Open AccessDifferential algebraic fast multipole-accelerated boundary element method for nonlinear beam dynamics in arbitrary enclosures
A novel method is developed to take into account realistic boundary conditions in intense nonlinear beam dynamics. The algorithm consists of three main ingredients: the boundary element method that provides a solution for the discretized reformulation of the Poisson equation as boundary integrals; a novel fast multipole method developed for accurate and efficient computation of Coulomb potentials and forces; and differential algebraic methods, which form the numerical structures that enable and hold together the different components. The fast multipole method, without any modifications, also accelerates the solution of intertwining linear systems of equations for further efficiency enhancements. The resulting algorithm scales linearly with the number of particles , as with the number of boundary elements , and, therefore, establishes an accurate and efficient method for intense beam dynamics simulations in arbitrary enclosures. Its performance is illustrated with three different cases and structures of practical interest. - Open Access
- 17 August 2017
- Published by Wiley in Journal of Chemometrics
- Vol. 31 (11)
Selectivity‐relaxed classical and inverse least squares calibration and selectivity measures with a unified selectivity coefficient
Two popular calibration strategies are classical least squares (CLS) and inverse least squares (ILS). Underlying CLS is that the net analyte signal used for quantitation is orthogonal to signal from other components (interferents). The CLS orthogonality avoids analyte prediction bias from modeled interferents. Although this orthogonality condition ensures full analyte selectivity, it may increase the mean squared error of prediction. Under certain circumstances, it can be beneficial to relax the CLS orthogonality requisite allowing a small interferent bias if, in return, there is a mean squared error of prediction reduction. The bias magnitude introduced by an interferent for a relaxed model depends on analyte and interferent concentrations in conjunction with analyte and interferent model sensitivities. Presented in this paper is relaxed CLS (rCLS) allowing flexibility in the CLS orthogonality constraints. While ILS models do not inherently maintain orthogonality, also presented is relaxed ILS. From development of rCLS, presented is a significant expansion of the univariate selectivity coefficient definition broadly used in analytical chemistry. The defined selectivity coefficient is applicable to univariate and multivariate CLS and ILS calibrations. As with the univariate selectivity coefficient, the multivariate expression characterizes the bias introduced in a particular sample prediction because of interferent concentrations relative to model sensitivities. Specifically, it answers the question of when can a prediction be made for a sample even though the analyte selectivity is poor? Also introduced are new component‐wise selectivity and sensitivity measures. Trends in several rCLS figures of merit are characterized for a near infrared data set.
- 17 August 2017
- Published by Wiley in Journal of Chemometrics
- Vol. 31 (11)
Open AccessSelectivity‐relaxed classical and inverse least squares calibration and selectivity measures with a unified selectivity coefficient
Two popular calibration strategies are classical least squares (CLS) and inverse least squares (ILS). Underlying CLS is that the net analyte signal used for quantitation is orthogonal to signal from other components (interferents). The CLS orthogonality avoids analyte prediction bias from modeled interferents. Although this orthogonality condition ensures full analyte selectivity, it may increase the mean squared error of prediction. Under certain circumstances, it can be beneficial to relax the CLS orthogonality requisite allowing a small interferent bias if, in return, there is a mean squared error of prediction reduction. The bias magnitude introduced by an interferent for a relaxed model depends on analyte and interferent concentrations in conjunction with analyte and interferent model sensitivities. Presented in this paper is relaxed CLS (rCLS) allowing flexibility in the CLS orthogonality constraints. While ILS models do not inherently maintain orthogonality, also presented is relaxed ILS. From development of rCLS, presented is a significant expansion of the univariate selectivity coefficient definition broadly used in analytical chemistry. The defined selectivity coefficient is applicable to univariate and multivariate CLS and ILS calibrations. As with the univariate selectivity coefficient, the multivariate expression characterizes the bias introduced in a particular sample prediction because of interferent concentrations relative to model sensitivities. Specifically, it answers the question of when can a prediction be made for a sample even though the analyte selectivity is poor? Also introduced are new component‐wise selectivity and sensitivity measures. Trends in several rCLS figures of merit are characterized for a near infrared data set.
- 14 March 2016
- Published by Wiley in Journal of Chemometrics
- Vol. 30 (4) , 144-152
Penalty processes for combining roughness and smoothness in spectral multivariate calibration
Tikhonov regularization (TR) has been successfully applied to form spectral multivariate calibration models by augmenting spectroscopic data with a regulation operator matrix. This matrix can be set to the identity matrix I (ridge regression), yielding what shall be considered rough regression vectors. It can also be set to the i‐th derivative operator matrix iL to form smoothed regression vectors. Two new penalty (regularization) methods are proposed that concurrently factor both roughness and smoothness in forming the model vector. This combination occurs by augmenting calibration spectra simultaneously with independently weighted I and iL matrices. The results of these two new methods are presented and compared with results using ridge regression forming rough model vectors and only using the smoothing TR processes. Partial least squares regression is also used to combine roughness and smoothness, and these results are compared with the TR variants. The sum of ranking differences algorithm and the two fusion rules sum and median are used for automatic model selection, that is, the appropriate tuning parameters for I and iL and partial least squares latent vectors. The approaches are evaluated using near‐infrared and ultraviolet‐visible spectral data sets. The near‐infrared set consists of corn samples for the analysis of protein and moisture content. The ultraviolet‐visible set consists of a three‐component system of inorganic elements. The general trends found are that when spectra are originally generally smooth, then using the smoothing methods provides no improvement in prediction errors. However, when spectra are considered noisy, then smoothing methods can assist in reducing prediction errors. This is especially true when the spectroscopic noise is more widespread across the wavelength regions. There was no difference in the results between the different smoothing methods. Copyright © 2016 John Wiley & Sons, Ltd.
- 14 March 2016
- Published by Wiley in Journal of Chemometrics
- Vol. 30 (4) , 144-152
Penalty processes for combining roughness and smoothness in spectral multivariate calibration
Tikhonov regularization (TR) has been successfully applied to form spectral multivariate calibration models by augmenting spectroscopic data with a regulation operator matrix. This matrix can be set to the identity matrix I (ridge regression), yielding what shall be considered rough regression vectors. It can also be set to the i‐th derivative operator matrix iL to form smoothed regression vectors. Two new penalty (regularization) methods are proposed that concurrently factor both roughness and smoothness in forming the model vector. This combination occurs by augmenting calibration spectra simultaneously with independently weighted I and iL matrices. The results of these two new methods are presented and compared with results using ridge regression forming rough model vectors and only using the smoothing TR processes. Partial least squares regression is also used to combine roughness and smoothness, and these results are compared with the TR variants. The sum of ranking differences algorithm and the two fusion rules sum and median are used for automatic model selection, that is, the appropriate tuning parameters for I and iL and partial least squares latent vectors. The approaches are evaluated using near‐infrared and ultraviolet‐visible spectral data sets. The near‐infrared set consists of corn samples for the analysis of protein and moisture content. The ultraviolet‐visible set consists of a three‐component system of inorganic elements. The general trends found are that when spectra are originally generally smooth, then using the smoothing methods provides no improvement in prediction errors. However, when spectra are considered noisy, then smoothing methods can assist in reducing prediction errors. This is especially true when the spectroscopic noise is more widespread across the wavelength regions. There was no difference in the results between the different smoothing methods. Copyright © 2016 John Wiley & Sons, Ltd.
- Open Access
- 1 August 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 754, 28-35
Electron cloud density measurements in accelerator beam-pipe using resonant microwave excitation
- 1 August 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 754, 28-35
Open AccessElectron cloud density measurements in accelerator beam-pipe using resonant microwave excitation