Elena Lukina
Research Subjects
Research Interests
Elena Lukina has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Mikhail Kollerov
MAI (National Research University), Volokolamskoeshosse.,4, Moscow 125993, Russia
6 shared publicationsPaul Wagstaff
Kingston University London, SW15 3DW, Friars Avenue, London, UK
4 shared publicationsPeter Mason
Kingston University London, SW15 3DW, Friars Avenue, London, UK
4 shared publicationsGordon Blunn
3 shared publicationsJay Meswania
University College London, Brockley Hill, Stanmore, London HA7 4LP, UK
3 shared publications- A. A. Ilyin
MATI—Tsiolkovskii Russian State University of Technology
2 shared publications
Latest Publications
- Open Access
- 1 March 2017
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 72, 601-610
Fretting corrosion behavior of nitinol spinal rods in conjunction with titanium pedicle screws
- 1 March 2017
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 72, 601-610
Open AccessFretting corrosion behavior of nitinol spinal rods in conjunction with titanium pedicle screws
- 1 January 2017
- Published by Elsevier in Materials Today: Proceedings
- Vol. 4 (3) , 4675-4679
The influence of TiN and DLC deposition on the wear resistance of Nitinol – Ti6Al4V combination for the medical application
- 1 January 2017
- Published by Elsevier in Materials Today: Proceedings
- Vol. 4 (3) , 4675-4679
The influence of TiN and DLC deposition on the wear resistance of Nitinol – Ti6Al4V combination for the medical application
- 1 March 2016
- Published by Elsevier in The Spine Journal
- Vol. 16 (3) , 380-388
Metal concentrations in the blood and tissues after implantation of titanium growth guidance sliding instrumentation
- 1 March 2016
- Published by Elsevier in The Spine Journal
- Vol. 16 (3) , 380-388
Metal concentrations in the blood and tissues after implantation of titanium growth guidance sliding instrumentation
- 1 January 2015
- Published by Wolters Kluwer Health in Spine
- Vol. 40 (1) , 17-24
Analysis of Retrieved Growth Guidance Sliding LSZ-4D Devices for Early Onset Scoliosis and Investigation of the Use of Nitinol Rods for This System
Analysis of volumetric wear loss of retrieved growth guidance sliding devices LSZ-4D for treatment of early onset scoliosis and laboratory in vitro wear test for comparison of wear resistance of alloys Nitinol, Ti, and cobalt chromium (CoCr). To evaluate quantitatively the amount of wear debris from the sliding LSZ-4D device and to investigate the potential of using Nitinol for replacing Ti alloys in spinal instrumentation. To do that, wear resistance of Nitinol, Ti, and CoCr was compared. There are little data regarding the amount of wear debris associated with growth guidance sliding devices for patients with early onset scoliosis and the wear resistance of superelastic Nitinol compared with Ti and CoCr. Volumetric wear loss was measured on LSZ-4D devices made from titanium alloy Ti6Al4V and each consisted of 2 rectangular section (6 × 4 mm) rods and 40 ± 8 fixture elements (20 ± 4 hooks and 20 ± 4 clips) retrieved from 3 patients (implantation period, 3.5-5.8 yr). Images of wear scars were taken on Bruker interferometer microscope and incorporated into MATLAB software. Wear resistance of Nitinol, Ti, and CoCr was studied using reciprocation pin-on-disk wear test in bovine serum at 37°C ± 1°C. The volume wear rate of LSZ-4D device was found to be 12.5 mm per year from which 5 mm³ per year is the wear debris of the rod and 7.5 mm per year is the contribution of fixtures. Wear resistance of Nitinol is 100 times higher than that of Ti and comparable with that of CoCr. Application of wear-resistant coatings on Ti components in growth guidance sliding devices for the treatment of early onset scoliosis will be useful. High wear resistance of Nitinol combined with its superelastic and shape memory properties could make application of Nitinol rods for spinal instrumentation beneficial.
- 1 January 2015
- Published by Wolters Kluwer Health in Spine
- Vol. 40 (1) , 17-24
Analysis of Retrieved Growth Guidance Sliding LSZ-4D Devices for Early Onset Scoliosis and Investigation of the Use of Nitinol Rods for This System
Analysis of volumetric wear loss of retrieved growth guidance sliding devices LSZ-4D for treatment of early onset scoliosis and laboratory in vitro wear test for comparison of wear resistance of alloys Nitinol, Ti, and cobalt chromium (CoCr). To evaluate quantitatively the amount of wear debris from the sliding LSZ-4D device and to investigate the potential of using Nitinol for replacing Ti alloys in spinal instrumentation. To do that, wear resistance of Nitinol, Ti, and CoCr was compared. There are little data regarding the amount of wear debris associated with growth guidance sliding devices for patients with early onset scoliosis and the wear resistance of superelastic Nitinol compared with Ti and CoCr. Volumetric wear loss was measured on LSZ-4D devices made from titanium alloy Ti6Al4V and each consisted of 2 rectangular section (6 × 4 mm) rods and 40 ± 8 fixture elements (20 ± 4 hooks and 20 ± 4 clips) retrieved from 3 patients (implantation period, 3.5-5.8 yr). Images of wear scars were taken on Bruker interferometer microscope and incorporated into MATLAB software. Wear resistance of Nitinol, Ti, and CoCr was studied using reciprocation pin-on-disk wear test in bovine serum at 37°C ± 1°C. The volume wear rate of LSZ-4D device was found to be 12.5 mm per year from which 5 mm³ per year is the wear debris of the rod and 7.5 mm per year is the contribution of fixtures. Wear resistance of Nitinol is 100 times higher than that of Ti and comparable with that of CoCr. Application of wear-resistant coatings on Ti components in growth guidance sliding devices for the treatment of early onset scoliosis will be useful. High wear resistance of Nitinol combined with its superelastic and shape memory properties could make application of Nitinol rods for spinal instrumentation beneficial.
- 1 November 2013
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 585, 356-362
Impact of material structure on the fatigue behaviour of NiTi leading to a modified Coffin–Manson equation
- 1 November 2013
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 585, 356-362
Impact of material structure on the fatigue behaviour of NiTi leading to a modified Coffin–Manson equation
- 1 January 2013
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 738-739, 316-320
Influence of the Structure on the Strain-Controlled Fatigue of Nitinol
The influence of increased dislocation density; dispersity of Ni-rich (Ti3Ni4 and Ti2Ni3) particles and volume fraction of Ti-rich (Ti2Ni) particles on the low-cycle (high amplitude) and high-cycle (low amplitude) fatigue resistance of nitinol has been considered in this paper. It was revealed that the fatigue resistance of nitinol in low-cycle conditions may be improved by increasing the part of deformation which is realized by martensitic mechanism. This part may be estimated by measuring εcr, which can reflect the influence of the structure parameter both on σM and σslip. It was found that in high-cycle fatigue conditions the substructure of nitinol predominantly determine its fatigue resistance, which is being the better in samples that had higher dislocation density or high dispersity of Ni-rich particles (up to 30 nm).
- 1 January 2013
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 738-739, 316-320
Influence of the Structure on the Strain-Controlled Fatigue of Nitinol
The influence of increased dislocation density; dispersity of Ni-rich (Ti3Ni4 and Ti2Ni3) particles and volume fraction of Ti-rich (Ti2Ni) particles on the low-cycle (high amplitude) and high-cycle (low amplitude) fatigue resistance of nitinol has been considered in this paper. It was revealed that the fatigue resistance of nitinol in low-cycle conditions may be improved by increasing the part of deformation which is realized by martensitic mechanism. This part may be estimated by measuring εcr, which can reflect the influence of the structure parameter both on σM and σslip. It was found that in high-cycle fatigue conditions the substructure of nitinol predominantly determine its fatigue resistance, which is being the better in samples that had higher dislocation density or high dispersity of Ni-rich particles (up to 30 nm).
- 1 October 2007
- Published by Pleiades Publishing Ltd in Russian Metallurgy (Metally)
- Vol. 2007 (5) , 423-427
Effect of vacuum ion-plasma treatment on the electrochemical corrosion characteristics of titanium-alloy implants
The effect of mechanical polishing and various types of vacuum ion-plasma treatment of model implants made of VT1-0, VT20, and VT6 titanium alloys on their electrochemical corrosion characteristics in a 0.9% NaCl solution (Ringer’s solution) is studied. Ion nitriding and the evaporation of a titanium nitride coating are shown to form a surface structure that provides an increase in the hardness, wear resistance, and corrosion resistance of these implants.
- 1 October 2007
- Published by Pleiades Publishing Ltd in Russian Metallurgy (Metally)
- Vol. 2007 (5) , 423-427
Effect of vacuum ion-plasma treatment on the electrochemical corrosion characteristics of titanium-alloy implants
The effect of mechanical polishing and various types of vacuum ion-plasma treatment of model implants made of VT1-0, VT20, and VT6 titanium alloys on their electrochemical corrosion characteristics in a 0.9% NaCl solution (Ringer’s solution) is studied. Ion nitriding and the evaporation of a titanium nitride coating are shown to form a surface structure that provides an increase in the hardness, wear resistance, and corrosion resistance of these implants.
- 1 October 2006
- Published by Pleiades Publishing Ltd in Russian Metallurgy (Metally)
- Vol. 2006 (5) , 400-405
Effect of the phase composition and structure of titanium alloys on their interaction with nitrogen during low-temperature ion nitriding
The interaction of nitrogen with commercial titanium alloys having a single-phase α (VT1-0, VT5 alloys) or β (TS6 alloy) structure and a two-phase α + β structure with various contents of the β phase (VT20, VT6, VT3-1, VT23, VT22) is studied during ion nitriding at 550 and 600°C. The initial phase composition, the degree of phase alloying, and the structure have been shown to substantially affect the length of the diffusion zone having an αN structure and the amounts of the Ti2N (ε phase) and TiN (δ phase) surface nitrides. A group of alloys containing up to 30% β phase in an α + β structure is separated. These alloys are of interest as a basis for designing surface gradient structure materials using surface nitrogen alloying upon low-temperature ion nitriding.
- 1 October 2006
- Published by Pleiades Publishing Ltd in Russian Metallurgy (Metally)
- Vol. 2006 (5) , 400-405
Effect of the phase composition and structure of titanium alloys on their interaction with nitrogen during low-temperature ion nitriding
The interaction of nitrogen with commercial titanium alloys having a single-phase α (VT1-0, VT5 alloys) or β (TS6 alloy) structure and a two-phase α + β structure with various contents of the β phase (VT20, VT6, VT3-1, VT23, VT22) is studied during ion nitriding at 550 and 600°C. The initial phase composition, the degree of phase alloying, and the structure have been shown to substantially affect the length of the diffusion zone having an αN structure and the amounts of the Ti2N (ε phase) and TiN (δ phase) surface nitrides. A group of alloys containing up to 30% β phase in an α + β structure is separated. These alloys are of interest as a basis for designing surface gradient structure materials using surface nitrogen alloying upon low-temperature ion nitriding.