Zekai Hong

Zekai Hong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zekai Hong has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A comparative study of cooling mechanisms in effusion and TPMS-based transpiration cooling

    by Juchan Son, Patrick Richer, Bertrand Jodoin, Sina Kashanj, Mohsen Broumand, Zekai Hong

  • Open Access

    Experimental characterization of a multi‑mechanism hydrogen sensing system in methane‑blended and oxygen‑deficient environments

    by Mohammed Waleed Qanbar, N. Utting, James Brydie, Zekai Hong

    Hydrogen leak detection in hydrogen–methane environments is constrained by sensor cross-sensitivity and oxygen-dependent response mechanisms, particularly in subsurface storage and blended natural gas systems. This study experimentally evaluates a multi-mechanism hydrogen sensing system integrating catalytic combustion, infrared methane detection, and a palladium-based thin-film resistor. The catalytic–infrared pair estimates hydrogen concentration by correcting methane contributions using the infrared sensor, and its performance is characterized over a range of hydrogen–methane compositions and oxygen levels from normoxic to anoxic conditions. Under oxygen-sufficient conditions, the catalytic–infrared approach provides reliable hydrogen quantification, but exhibits systematic bias as oxygen availability decreases, with complete loss of functionality in oxygen-free environments. Sensor behavior is shown to be governed by oxygen availability relative to the stoichiometric oxygen demand, with methane-rich mixtures inducing earlier performance degradation. The thin-film resistor provides oxygen-independent hydrogen detection across all tested oxygen conditions, including oxygen-free environments, but undergoes irreversible drift under prolonged exposure to high hydrogen concentrations. Discrepancies between the catalytic–infrared and thin-film resistor readings provide a robust indicator of oxygen-deficient conditions and loss of catalytic sensing capability. These results quantify the benefits and limitations of combining catalytic, infrared, and thin-film resistor sensors for hydrogen monitoring in methane-containing and oxygen-limited environments, and inform the design of multi-mechanism sensing architectures for emerging hydrogen energy systems.

  • Impact of Triply Periodic Minimal Surface Structure Unit Cell Size on Transpiration Cooling

    by Juchan Son, Yeongmin Pyo, Patrick Richer, Bertrand Jodoin, Zekai Hong

    Transpiration cooling is a highly promising technology for use in thermal management in modern gas-turbine-based aeroengines, providing superior cooling effectiveness compared to state-of-the-art effusion cooling methods. However, conventional porous media such as metallic foams and sintered metals, when used for transpiration cooling, face challenges in achieving desired engineering properties, such as surface texture, mechanical strength, and porosity profile. To achieve the full potential of transpiration cooling by overcoming the challenges inherent in conventional porous media, a precisely engineered deterministic porous medium is desirable. Recent advancements in additive manufacturing have enabled the fabrication of porous media with highly precise lattice structures. Among candidate lattice structures, triply periodic minimal surface (TPMS) structures are considered ideal due to their superior mechanical strengths and fully interconnected, periodic internal channels and external texture patterns to facilitate cooling film development. This study aims to investigate the impact of unit cell size of TPMS lattices on adiabatic film cooling effectiveness using binary pressure-sensitive paint (PSP). Diamond-type TPMS lattices of a fixed actual porosity (36%) but of three distinct unit cell sizes (1.9, 2.5, and 3.1 mm) were examined at three injection ratios ([ ], 1.14%, and 1.60%). Results show that smaller unit cell sizes lead to more effective and more uniform cooling films. Enhanced transpiration cooling effectiveness at smaller unit sizes might be attributed to shallower surface voids and reduced lateral flow within the porous medium. The findings are expected to guide the design of TPMS-based transpiration cooling systems.


  • Effects of Lattice Orientation Angle on TPMS-Based Transpiration Cooling

    by Juchan Son, Mohsen Broumand, Yeongmin Pyo, Patrick Richer, Bertrand Jodoin, Zekai Hong

    Establishing a continuous cooling film is an effective way to thermally protect hot-gas path components of gas turbines. For aero-engines, effusion cooling is the state-of-the-art method for developing cooling films. However, the cooling film generated by this method is far from ideal, as discrete miniature cooling air jets exiting from effusion cooling holes leave large gaps between cooling holes without adequate cooling film protection. Furthermore, effusion cooling jets can experience strong liftoff from component surfaces and are subsequently diluted due to mixing with the main flow. Recent advances in additive manufacturing (AM) technologies have enabled the fabrication of porous materials with precisely engineered lattice structures, significantly enhancing the film cooling effectiveness of hot-gas path components through transpiration cooling. A prior study has demonstrated highly promising transpiration cooling results by using a family of lattice geometries referred to as triply periodic minimal surface (TPMS) lattices. The present study experimentally investigates the influence of various TPMS lattice orientations on the film cooling effectiveness. Three types of TPMS structures, namely, diamond, Koch, and gyroid, are compared to demonstrate that the TPMS lattice orientation angle affects transpiration cooling performance, with different levels of sensitivity according to the TPMS structure. The TPMS lattice structures studied in this investigation are fabricated by stereolithography (SLA) three-dimensional printing. The adiabatic cooling film effectiveness (AFE) is measured using pressure sensitive paint (PSP).


  • Open Access

    Isolating influences of varying pitch from the effects of non-zero compound angles on effusion cooling

    by Y. Pyo, J. Son, P. Richer, B. Jodoin, M. Broumand, S. Yun, Z. Hong

    Effusion cooling is the state-of-the-art cooling technology for gas turbine hot-gas path components. Typically, effusion cooling holes across the entire combustor liner are aligned with the combustor axis, rendering a nominal zero compound angle between highly directional miniature effusion cooling jets and the main flow direction. The pitch of effusion cooling holes is optimised accordingly. However, the swirling main flow results in a non-zero compound angle and an effectively different pitch from the design. The directional effect of effusion cooling as a result of swirling main flow on the adiabatic film cooling effectiveness (AFE) is a combined effect of a non-zero compound angle and a varied pitch. The current experimental study aims to investigate the isolated effects of compound angle on AFE by excluding the influences of varying pitch. With an improved understanding of the sole effects of non-zero compound angles on AFE, the roles that a varied pitch plays in modifying AFE are further discussed to guide future effusion cooling designs under swirling main flow conditions. Binary pressure sensitive paint (PSP) was used to determine AFE experimentally.


  • A Large Eddy Simulation Study on Hydrogen Microjets in Hot Vitiated Crossflow

    by Mohsen Broumand, Sean Yun, Zekai Hong

    In this paper, the results of a large eddy simulation (LES) study on hydrogen microjets (dj ~ 0.5 mm) injected into a hot (1600 K) vitiated crossflow at different angles?namely, normal (90°) and inclined jet (30°), are presented. The goal is to explore the effects of injection angle on coherent turbulent structure formations, flame-vortex interactions, and wall heat flux contributions. The LES identifies the presence of the horseshoe vortex, the shear layer vortices (SLV), and the counter-rotating vortex pair (CVP), along with the shedding of spanwise-symmetry hairpin vortices in both the normal and inclined jets. The structures in the latter, however, appear more convoluted. In the near field, SLV-induced flow is crucial for mixing and flame propagation on the windward side of the jet, stabilized by autoignition near the jet exits. A flame-shear layer offset is observed here. In the far field, CVP dominates hot vitiated crossflow entrainment, driving flame propagation and heat and species transfer to the leeward side near the injection wall. In the wake region, combustion remains closer to the normal jet exit due to a stronger recirculation zone, resulting in higher wall heat fluxes. The mean wall heat flux values of both the normal and inclined jets decrease and approach each other with moving away from the jet exit in the streamwise direction. The present LES study results are compared to experimental data from the literature by considering instantaneous hydroxide (OH) fields and mean wall heat fluxes.


  • Top Cited Papers
    Open Access

    A Review of Hydrogen Leak Detection Regulations and Technologies

    by Mohammed W. Qanbar, Zekai Hong

    Hydrogen (H2) is positioned as a key solution to the decarbonization challenge in both the energy and transportation sectors. While hydrogen is a clean and versatile energy carrier, it poses significant safety risks due to its wide flammability range and high detonation potential. Hydrogen leaks can occur throughout the hydrogen value chain, including production, storage, transportation, and utilization. Thus, effective leak detection systems are essential for the safe handling, storage, and transportation of hydrogen. This review aims to survey relevant codes and standards governing hydrogen-leak detection and evaluate various sensing technologies based on their working principles and effectiveness. Our analysis highlights the strengths and limitations of the current detection technologies, emphasizing the challenges in achieving sensitive and specific hydrogen detection. The results of this review provide critical insights into the existing technologies and regulatory frameworks, informing future advancements in hydrogen safety protocols.


  • Quasi-Two-Dimensional Simulation of a Rotating Detonation Engine Combustor and Injector

    by S. She-Ming Lau-Chapdelaine, Matei I. Radulescu, Zekai Hong

    A numerical simulation of an annular rotating detonation engine with stoichiometric hydrogen–oxygen is performed. A generic, well-posed, and easily implemented approach using a quasi-two-dimensional method to model the area variations through the rotating detonation engine’s injector and combustor is presented. The detonation–injector interaction is studied for the case with a ratio of four between the combustor and injector’s throat areas. A shock wave is formed in the divergent portion of the injector due to the high backpressure created by the detonation in the combustor. A Favre-averaged steady-state analysis of stream lines and particle paths reveals that the shock causes an irrecoverable loss of stagnation pressure. Stagnation pressure gain in the combustor is insufficient to make up for the loss, and the flow leaves the engine with lower stagnation pressure than in the plenum.