Jianzhong Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jianzhong Zhao has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Lu Lu
Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
5 shared publications Xingming Guo
Shanghai Key Laboratory of Mechanics in Energy Engineering Shanghai Institute of Applied Mathematics and Mechanics School of Mechanics and Engineering Science Shanghai University Shanghai People's Republic of China
5 shared publications- Yihui Zhang
Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, P.R. China
5 shared publications - Shiwei Xu
Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, P.R. China
3 shared publications - Yu Lan
Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China
3 shared publications - Renheng Bo
Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, P.R. China
2 shared publications
Latest Publications
- 7 September 2026
- Published by Wiley in Advanced Materials Technologies
Personalized Skin Temperature Benchmark via Wireless Wearable Sensor for Assessing Peripheral Thermoregulation
Hypothermia constitutes a substantial risk in outdoor and occupational environments. However, conventional assessment methods rely on population‑based statistical norms, which often fail to account for interindividual variability. This study proposes the concept of a personalized skin temperature benchmark, defined as an individual‐specific database of skin temperature acquired from multiple body sites and associated with health status as well as environmental conditions. To realize this concept, a custom‑designed wireless wearable flexible temperature sensor was developed, enabling comfortable and continuous monitoring at the wrist, forehead, and chest. Data were collected from two healthy male subjects by systematically varying physical activity level and clothing insulation index, while simultaneously measuring apparent temperature (which depends on ambient temperature, humidity, and wind speed). The results revealed significant differences in skin temperature benchmarks between the two individuals. A key parameter (skin heat loss) is introduced to quantify peripheral thermoregulation, with its values serving as a personalized indicator, and peripheral thermoregulation classification requires further validation. A critical step toward non‑invasive early warning of hypothermia lies in establishing reliable skin–core temperature calibration, yet this remains an open challenge.
- 7 September 2026
- Published by Wiley in Advanced Materials Technologies
Personalized Skin Temperature Benchmark via Wireless Wearable Sensor for Assessing Peripheral Thermoregulation
Hypothermia constitutes a substantial risk in outdoor and occupational environments. However, conventional assessment methods rely on population‑based statistical norms, which often fail to account for interindividual variability. This study proposes the concept of a personalized skin temperature benchmark, defined as an individual‐specific database of skin temperature acquired from multiple body sites and associated with health status as well as environmental conditions. To realize this concept, a custom‑designed wireless wearable flexible temperature sensor was developed, enabling comfortable and continuous monitoring at the wrist, forehead, and chest. Data were collected from two healthy male subjects by systematically varying physical activity level and clothing insulation index, while simultaneously measuring apparent temperature (which depends on ambient temperature, humidity, and wind speed). The results revealed significant differences in skin temperature benchmarks between the two individuals. A key parameter (skin heat loss) is introduced to quantify peripheral thermoregulation, with its values serving as a personalized indicator, and peripheral thermoregulation classification requires further validation. A critical step toward non‑invasive early warning of hypothermia lies in establishing reliable skin–core temperature calibration, yet this remains an open challenge.
- 23 December 2025
- Published by Elsevier in Thin-Walled Structures
- Vol. 221
Thread-pulling-induced assembly strategy for complex 3D structures
- 23 December 2025
- Published by Elsevier in Thin-Walled Structures
- Vol. 221
Thread-pulling-induced assembly strategy for complex 3D structures
- Open Access
- 20 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (51) , eadp1176
An agile multimodal microrobot with architected passively morphing wheels
Multimodal microrobots are of growing interest due to their capabilities to navigate diverse terrains, with promising applications in inspection, exploration, and biomedicine. Despite remarkable progress, it remains challenging to combine the attributes of excellent maneuverability, low power consumption, and high robustness in a single multimodal microrobot. We propose an architected design of a passively morphing wheel that can be stabilized at distinct geometric configurations, relying on asymmetric bending stiffness of bioinspired tentacle structures. By integrating such wheels with electromagnetic motors and a flexible body, we develop a highly compact, lightweight, multimodal microrobot (length ~32 mm and mass ~4.74 g) with three locomotion gaits. It has high motion speed (~21.2 BL/s), excellent agility (relative centripetal acceleration, ~206.9 BL/s 2 ), low power consumption (cost of transport, ~89), high robustness, and strong terrain adaptabilities. Integration of batteries and a wireless control module enables developments of an untethered microrobot that maintains high motion speed and excellent agility, with capabilities of traveling in hybrid terrains.
- 20 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (51) , eadp1176
Open AccessAn agile multimodal microrobot with architected passively morphing wheels
Multimodal microrobots are of growing interest due to their capabilities to navigate diverse terrains, with promising applications in inspection, exploration, and biomedicine. Despite remarkable progress, it remains challenging to combine the attributes of excellent maneuverability, low power consumption, and high robustness in a single multimodal microrobot. We propose an architected design of a passively morphing wheel that can be stabilized at distinct geometric configurations, relying on asymmetric bending stiffness of bioinspired tentacle structures. By integrating such wheels with electromagnetic motors and a flexible body, we develop a highly compact, lightweight, multimodal microrobot (length ~32 mm and mass ~4.74 g) with three locomotion gaits. It has high motion speed (~21.2 BL/s), excellent agility (relative centripetal acceleration, ~206.9 BL/s 2 ), low power consumption (cost of transport, ~89), high robustness, and strong terrain adaptabilities. Integration of batteries and a wireless control module enables developments of an untethered microrobot that maintains high motion speed and excellent agility, with capabilities of traveling in hybrid terrains.
- 19 November 2024
- Published by Elsevier in Journal of the Mechanics and Physics of Solids
- Vol. 195
Imperfection-insensitive flexible random network materials with horseshoe microstructures
- 19 November 2024
- Published by Elsevier in Journal of the Mechanics and Physics of Solids
- Vol. 195
Imperfection-insensitive flexible random network materials with horseshoe microstructures
- Open Access
- 29 September 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (39) , eadi8606
Inversely engineered biomimetic flexible network scaffolds for soft tissue regeneration
Graft-host mechanical mismatch has been a longstanding issue in clinical applications of synthetic scaffolds for soft tissue regeneration. Although numerous efforts have been devoted to resolve this grand challenge, the regenerative performance of existing synthetic scaffolds remains limited by slow tissue growth (comparing to autograft) and mechanical failures. We demonstrate a class of rationally designed flexible network scaffolds that can precisely replicate nonlinear mechanical responses of soft tissues and enhance tissue regeneration via reduced graft-host mechanical mismatch. Such flexible network scaffold includes a tubular network frame containing inversely engineered curved microstructures to produce desired mechanical properties, with an electrospun ultrathin film wrapped around the network to offer a proper microenvironment for cell growth. Using rat models with sciatic nerve defects or Achilles tendon injuries, our network scaffolds show regenerative performances evidently superior to that of clinically approved electrospun conduit scaffolds and achieve similar outcomes to autologous nerve transplantation in prevention of target organ atrophy and recovery of static sciatic index.
- 29 September 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (39) , eadi8606
Open AccessInversely engineered biomimetic flexible network scaffolds for soft tissue regeneration
Graft-host mechanical mismatch has been a longstanding issue in clinical applications of synthetic scaffolds for soft tissue regeneration. Although numerous efforts have been devoted to resolve this grand challenge, the regenerative performance of existing synthetic scaffolds remains limited by slow tissue growth (comparing to autograft) and mechanical failures. We demonstrate a class of rationally designed flexible network scaffolds that can precisely replicate nonlinear mechanical responses of soft tissues and enhance tissue regeneration via reduced graft-host mechanical mismatch. Such flexible network scaffold includes a tubular network frame containing inversely engineered curved microstructures to produce desired mechanical properties, with an electrospun ultrathin film wrapped around the network to offer a proper microenvironment for cell growth. Using rat models with sciatic nerve defects or Achilles tendon injuries, our network scaffolds show regenerative performances evidently superior to that of clinically approved electrospun conduit scaffolds and achieve similar outcomes to autologous nerve transplantation in prevention of target organ atrophy and recovery of static sciatic index.
- Open Access
- 16 August 2023
- Published by Wiley in Advanced Materials Interfaces
- Vol. 10 (36)
Bioelectric Interface Technologies in Cells and Organoids
The past two decades have witnessed breakthroughs in cellular‐scale bioelectronics and their widespread applications in life sciences, creating many powerful platforms for studying organisms directly and efficiently. These advanced devices can integrate seamlessly and intimately onto/into target cells and organoids, providing unprecedented functions and revolutionary capabilities. Bioelectronics with nanostructured designs are developed to allow for long‐term, stable monitoring of electrophysiological activities. This review summarizes nanostructured bioelectronics for cell electrophysiology recording, emphasizing the crucial roles of structural designs on functions and capabilities, e.g., intracellular access, high‐density multiplexed recording, multifunctional interfaces and the conformability to curvy biological shapes. Finally, the remaining challenges and opportunities in nanostructured bioelectronics are identified, and perspectives on the future developments toward their practical applications are provided.
- 16 August 2023
- Published by Wiley in Advanced Materials Interfaces
- Vol. 10 (36)
Open AccessBioelectric Interface Technologies in Cells and Organoids
The past two decades have witnessed breakthroughs in cellular‐scale bioelectronics and their widespread applications in life sciences, creating many powerful platforms for studying organisms directly and efficiently. These advanced devices can integrate seamlessly and intimately onto/into target cells and organoids, providing unprecedented functions and revolutionary capabilities. Bioelectronics with nanostructured designs are developed to allow for long‐term, stable monitoring of electrophysiological activities. This review summarizes nanostructured bioelectronics for cell electrophysiology recording, emphasizing the crucial roles of structural designs on functions and capabilities, e.g., intracellular access, high‐density multiplexed recording, multifunctional interfaces and the conformability to curvy biological shapes. Finally, the remaining challenges and opportunities in nanostructured bioelectronics are identified, and perspectives on the future developments toward their practical applications are provided.
- Top Cited Papers
- 10 April 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1215-1228
A battery-less wireless implant for the continuous monitoring of vascular pressure, flow rate and temperature
Devices for monitoring blood haemodynamics can guide the perioperative management of patients with cardiovascular disease. Current technologies for this purpose are constrained by wired connections to external electronics, and wireless alternatives are restricted to monitoring of either blood pressure or blood flow. Here we report the design aspects and performance parameters of an integrated wireless sensor capable of implantation in the heart or in a blood vessel for simultaneous measurements of pressure, flow rate and temperature in real time. The sensor is controlled via long-range communication through a subcutaneously implanted and wirelessly powered Bluetooth Low Energy system-on-a-chip. The device can be delivered via a minimally invasive transcatheter procedure or it can be mounted on a passive medical device such as a stent, as we show for the case of the pulmonary artery in a pig model and the aorta and left ventricle in a sheep model, where the device performs comparably to clinical tools for monitoring of blood flow and pressure. Battery-less and wireless devices such as these that integrate capabilities for flow, pressure and temperature sensing offer the potential for continuous monitoring of blood haemodynamics in patients.
- 10 April 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1215-1228
Top Cited PapersA battery-less wireless implant for the continuous monitoring of vascular pressure, flow rate and temperature
Devices for monitoring blood haemodynamics can guide the perioperative management of patients with cardiovascular disease. Current technologies for this purpose are constrained by wired connections to external electronics, and wireless alternatives are restricted to monitoring of either blood pressure or blood flow. Here we report the design aspects and performance parameters of an integrated wireless sensor capable of implantation in the heart or in a blood vessel for simultaneous measurements of pressure, flow rate and temperature in real time. The sensor is controlled via long-range communication through a subcutaneously implanted and wirelessly powered Bluetooth Low Energy system-on-a-chip. The device can be delivered via a minimally invasive transcatheter procedure or it can be mounted on a passive medical device such as a stent, as we show for the case of the pulmonary artery in a pig model and the aorta and left ventricle in a sheep model, where the device performs comparably to clinical tools for monitoring of blood flow and pressure. Battery-less and wireless devices such as these that integrate capabilities for flow, pressure and temperature sensing offer the potential for continuous monitoring of blood haemodynamics in patients.
- 22 February 2023
- Published by Wiley in Journal of Applied Mechanics
- Vol. 90 (6) , 1-33
Electroadhesion-Mediated Interface Delamination for Assembly of Reconfigurable 3D Mesostructures
Recently developed buckling-guided assembly methods provide a unique route to the design and manufacture of 3D mesostructures and microelectronic devices with superior performances and unusual functions. Combined with loading-path controlled strategies and/or active material designs, reconfigurable 3D mesostructures with multiple stable 3D geometries can be formed, holding promising potentials for applications in tunable antennas and multimodal actuators. The existing strategies are, however, limited by the applicable range of material types or requirements for switching between various complicated loading paths. Here, we present an electroadhesion-mediated strategy to achieve controlled adhesion of the 3D mesostructure to the substrate during the buckling-guided assembly. This strategy allows an active control of the delamination behavior in the film/substrate system, such that a variety of reconfigurable 3D mesostructures can be accessed by designing the 2D precursor pattern and electrode layout. An electromechanical model is developed to capture the delamination behavior of the film/substrate system under combined compression and voltage loadings, which agrees well with experimental measurements. Based on this model, an equivalent interface energy is proposed to quantify the contributions of the electroadhesion and van der Waals’ interactions, which also facilitates simulations of the interface delamination with cohesive models in finite element analyses (FEAs). Furthermore, a variety of reconfigurable 3D mesostructures are demonstrated experimentally, and their geometric configurations are in close accordance with the results of FEA using the concept of equivalent interface energy.
- 22 February 2023
- Published by Wiley in Journal of Applied Mechanics
- Vol. 90 (6) , 1-33
Electroadhesion-Mediated Interface Delamination for Assembly of Reconfigurable 3D Mesostructures
Recently developed buckling-guided assembly methods provide a unique route to the design and manufacture of 3D mesostructures and microelectronic devices with superior performances and unusual functions. Combined with loading-path controlled strategies and/or active material designs, reconfigurable 3D mesostructures with multiple stable 3D geometries can be formed, holding promising potentials for applications in tunable antennas and multimodal actuators. The existing strategies are, however, limited by the applicable range of material types or requirements for switching between various complicated loading paths. Here, we present an electroadhesion-mediated strategy to achieve controlled adhesion of the 3D mesostructure to the substrate during the buckling-guided assembly. This strategy allows an active control of the delamination behavior in the film/substrate system, such that a variety of reconfigurable 3D mesostructures can be accessed by designing the 2D precursor pattern and electrode layout. An electromechanical model is developed to capture the delamination behavior of the film/substrate system under combined compression and voltage loadings, which agrees well with experimental measurements. Based on this model, an equivalent interface energy is proposed to quantify the contributions of the electroadhesion and van der Waals’ interactions, which also facilitates simulations of the interface delamination with cohesive models in finite element analyses (FEAs). Furthermore, a variety of reconfigurable 3D mesostructures are demonstrated experimentally, and their geometric configurations are in close accordance with the results of FEA using the concept of equivalent interface energy.
- 6 January 2023
- Published by Elsevier in Journal of the Mechanics and Physics of Solids
- Vol. 173
A wrinkling-assisted strategy for controlled interface delamination in mechanically-guided 3D assembly
- 6 January 2023
- Published by Elsevier in Journal of the Mechanics and Physics of Solids
- Vol. 173
A wrinkling-assisted strategy for controlled interface delamination in mechanically-guided 3D assembly
- 1 March 2018
- Published by Elsevier in International Journal of Engineering Science
- Vol. 124, 24-40
On the mechanics of Kirchhoff and Mindlin plates incorporating surface energy
- 1 March 2018
- Published by Elsevier in International Journal of Engineering Science
- Vol. 124, 24-40
On the mechanics of Kirchhoff and Mindlin plates incorporating surface energy