Boliang Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Boliang Jia has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Wen Jung Li
Department of Mechanical Engineering, City University of Hong Kong, Hong Kong SAR, China
6 shared publications - Ho-Yin Chan
City University of Hong Kong
3 shared publications Feifei Wang
Shenzhen Academy of Robotics, Shenzhen, 518000 China
2 shared publicationsGuanglie Zhang
Shenzhen Academy of Robotics, Shenzhen, 518000 China
2 shared publicationsLianqing Liu
Shenyang Institute of Automation, Chinese Academy of Sciences, China
2 shared publications- Lianqing Liu
Chinese Academy of Sciences
2 shared publications
Latest Publications
- 11 February 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 204, 114084
Optothermophoretic flipping method for biomolecule interaction enhancement
- 11 February 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 204, 114084
Optothermophoretic flipping method for biomolecule interaction enhancement
- Open Access
- 1 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Nanotechnology
- Vol. 2, 161-177
Recent Advances in Femtosecond Laser Fabrication: From Structures to Applications
Femtosecond laser processing is fast becoming a pervasive method for fabricating micro/nanostructures because it can be used to produce micro/nanostructures on myriads of materials with high precision and resolution, requires little control over environmental conditions, and is simple to implement. Here, we review recent developments in the use of femtosecond lasers for the fabrication of micro/nanostructures through ablation and two-photon polymerization (TPP). Moreover, the applications of some of the fabricated micro/nanostructures are also discussed. We highlight the advantages of femtosecond laser processing by explaining the underlying principles of laser ablation and TPP. We also show the use of this method to fabricate new devices with outstanding performance in several application realm, such as sensors, optical devices, microfluidic chips, and soft robotics.
- 1 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Nanotechnology
- Vol. 2, 161-177
Open AccessRecent Advances in Femtosecond Laser Fabrication: From Structures to Applications
Femtosecond laser processing is fast becoming a pervasive method for fabricating micro/nanostructures because it can be used to produce micro/nanostructures on myriads of materials with high precision and resolution, requires little control over environmental conditions, and is simple to implement. Here, we review recent developments in the use of femtosecond lasers for the fabrication of micro/nanostructures through ablation and two-photon polymerization (TPP). Moreover, the applications of some of the fabricated micro/nanostructures are also discussed. We highlight the advantages of femtosecond laser processing by explaining the underlying principles of laser ablation and TPP. We also show the use of this method to fabricate new devices with outstanding performance in several application realm, such as sensors, optical devices, microfluidic chips, and soft robotics.
- 13 May 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (13) , 2586-2593
Real-time red blood cell counting and osmolarity analysis using a photoacoustic-based microfluidic system
Counting the number of red blood cells (RBCs) in blood samples is a common clinical diagnostic procedure, but conventional methods are unable to provide the size and other physical properties of RBCs at the same time. In this work, we explore photoacoustic (PA) detection as a rapid label-free and noninvasive analysis technique that can potentially be used for single RBC characterization based on their photoabsorption properties. We have demonstrated an on-chip PA flow cytometry system using a simple microfluidic chip combined with a PA imaging system to count and characterize up to ∼60 RBCs per second. Compared with existing microfluidic-based RBC analysis methods, which typically use camera-captured image sequences to characterize cell morphology and deformation, the PA method discussed here requires only the processing of one-dimensional time-series data instead of two- or three-dimensional time-series data acquired by computer vision methods. Therefore, the PA method will have significantly lower computational requirements when large numbers of RBCs are to be analyzed. Moreover, we have demonstrated that the PA signals of RBCs flowing in a microfluidic device could be directly used to acquire the osmolarity conditions (in the range of 124 to 497 mOsm L−1) of the medium surrounding the RBCs. This finding suggests a potential extension of applicability to blood tests via PA-based biomedical detection.
- 13 May 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (13) , 2586-2593
Real-time red blood cell counting and osmolarity analysis using a photoacoustic-based microfluidic system
Counting the number of red blood cells (RBCs) in blood samples is a common clinical diagnostic procedure, but conventional methods are unable to provide the size and other physical properties of RBCs at the same time. In this work, we explore photoacoustic (PA) detection as a rapid label-free and noninvasive analysis technique that can potentially be used for single RBC characterization based on their photoabsorption properties. We have demonstrated an on-chip PA flow cytometry system using a simple microfluidic chip combined with a PA imaging system to count and characterize up to ∼60 RBCs per second. Compared with existing microfluidic-based RBC analysis methods, which typically use camera-captured image sequences to characterize cell morphology and deformation, the PA method discussed here requires only the processing of one-dimensional time-series data instead of two- or three-dimensional time-series data acquired by computer vision methods. Therefore, the PA method will have significantly lower computational requirements when large numbers of RBCs are to be analyzed. Moreover, we have demonstrated that the PA signals of RBCs flowing in a microfluidic device could be directly used to acquire the osmolarity conditions (in the range of 124 to 497 mOsm L−1) of the medium surrounding the RBCs. This finding suggests a potential extension of applicability to blood tests via PA-based biomedical detection.
- Open Access
- 31 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Nanotechnology
- Vol. 1, 65-76
Determination of Microsphere-Lens Magnification Using Micro-Robotic Scanning Superlens Nanoscopy
Microsphere-assisted nanoscopy has shown great potential in recent developments in the field of super-resolution imaging. The precise control of microspheres is leading to new discoveries that can help verify the theories behind the super-resolution imaging mechanism. However, microsphere imaging involves multiple planes that have different magnification factors, which affect the determination of the overall resolution of the image. In this study, we present a flexible probelens assembly scheme that uses a barium titanate glass microsphere, as well as various scanning stages that can be used to freely investigate the sample surface and perform large-area super-resolution imaging (80 μm 60 μm). The obtained resolution using this assembly under water immersion condition is 130 nm. By investigating the relationship between the magnification factors and the corresponding focus position of the different feature patterns, a remarkable difference in the focusing characteristics between arbitrary and periodic patterns was revealed. Results demonstrate the universality of the proposed method for the quantitative selection of the best focused plane and determination of the corresponding magnification factor and resolution of a microsphere virtual image for any feature pattern. The findings provide additional insights into the interpretation of arbitrary nanostructures through 3D optical imaging.
- 31 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Nanotechnology
- Vol. 1, 65-76
Open AccessDetermination of Microsphere-Lens Magnification Using Micro-Robotic Scanning Superlens Nanoscopy
Microsphere-assisted nanoscopy has shown great potential in recent developments in the field of super-resolution imaging. The precise control of microspheres is leading to new discoveries that can help verify the theories behind the super-resolution imaging mechanism. However, microsphere imaging involves multiple planes that have different magnification factors, which affect the determination of the overall resolution of the image. In this study, we present a flexible probelens assembly scheme that uses a barium titanate glass microsphere, as well as various scanning stages that can be used to freely investigate the sample surface and perform large-area super-resolution imaging (80 μm 60 μm). The obtained resolution using this assembly under water immersion condition is 130 nm. By investigating the relationship between the magnification factors and the corresponding focus position of the different feature patterns, a remarkable difference in the focusing characteristics between arbitrary and periodic patterns was revealed. Results demonstrate the universality of the proposed method for the quantitative selection of the best focused plane and determination of the corresponding magnification factor and resolution of a microsphere virtual image for any feature pattern. The findings provide additional insights into the interpretation of arbitrary nanostructures through 3D optical imaging.
- Open Access
- 14 January 2019
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 5 (1) , 1-13
In situ printing of liquid superlenses for subdiffraction-limited color imaging of nanobiostructures in nature
The nanostructures and patterns that exist in nature have inspired researchers to develop revolutionary components for use in modern technologies and our daily lives. The nanoscale imaging of biological samples with sophisticated analytical tools, such as scanning electron microscopy (SEM) and transmission electron microscopy (TEM), has afforded a precise understanding of structures and has helped reveal the mechanisms contributing to the behaviors of the samples but has done so with the loss of photonic properties. Here, we present a new method for printing biocompatible “superlenses” directly on biological objects to observe subdiffraction-limited features under an optical microscope in color. We demonstrate the nanoscale imaging of butterfly wing scales with a super-resolution and larger field-of-view (FOV) than those of previous dielectric microsphere techniques. Our approach creates a fast and flexible path for the direct color observation of nanoscale biological features in the visible range and enables potential optical measurements at the subdiffraction-limited scale.
- 14 January 2019
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 5 (1) , 1-13
Open AccessIn situ printing of liquid superlenses for subdiffraction-limited color imaging of nanobiostructures in nature
The nanostructures and patterns that exist in nature have inspired researchers to develop revolutionary components for use in modern technologies and our daily lives. The nanoscale imaging of biological samples with sophisticated analytical tools, such as scanning electron microscopy (SEM) and transmission electron microscopy (TEM), has afforded a precise understanding of structures and has helped reveal the mechanisms contributing to the behaviors of the samples but has done so with the loss of photonic properties. Here, we present a new method for printing biocompatible “superlenses” directly on biological objects to observe subdiffraction-limited features under an optical microscope in color. We demonstrate the nanoscale imaging of butterfly wing scales with a super-resolution and larger field-of-view (FOV) than those of previous dielectric microsphere techniques. Our approach creates a fast and flexible path for the direct color observation of nanoscale biological features in the visible range and enables potential optical measurements at the subdiffraction-limited scale.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Micro-Dispensing of Graphene Oxide Based Capacitive Tactile Sensors for Human Pressure-Pulse Detection
This paper reports a novel capacitive pressure-pulse sensor array based on drop-dispensed graphene oxide (GO) sensing elements. The utilization of drop dispensing technology enables us a low cost, flexible and precise method to fabricate multiple capacitive sensing elements. The printed droplets volume (GO aqueous dispersion) were around 33.5 to 65.4 pL with droplet diameter ranging 40 to 50um. The size (i.e., footprint and dielectric thickness) of a sensing element can be controlled by the total GO dispersed. In this paper, we report on the fabrication process and preliminary characterization of these printed GO capacitive sensors. Thus far, we have shown that these sensors have a sensitivity of ~10- 3 kPa- 1 , with a relative permittivity of the printed GO being ~6 to 7 (measured at a frequency of 600kHz). We have also demonstrated that the printed sensing elements can be used for human pulse sensing, which means that these sensors could potentially be used in wearable electronics and healthcare applications.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Micro-Dispensing of Graphene Oxide Based Capacitive Tactile Sensors for Human Pressure-Pulse Detection
This paper reports a novel capacitive pressure-pulse sensor array based on drop-dispensed graphene oxide (GO) sensing elements. The utilization of drop dispensing technology enables us a low cost, flexible and precise method to fabricate multiple capacitive sensing elements. The printed droplets volume (GO aqueous dispersion) were around 33.5 to 65.4 pL with droplet diameter ranging 40 to 50um. The size (i.e., footprint and dielectric thickness) of a sensing element can be controlled by the total GO dispersed. In this paper, we report on the fabrication process and preliminary characterization of these printed GO capacitive sensors. Thus far, we have shown that these sensors have a sensitivity of ~10- 3 kPa- 1 , with a relative permittivity of the printed GO being ~6 to 7 (measured at a frequency of 600kHz). We have also demonstrated that the printed sensing elements can be used for human pulse sensing, which means that these sensors could potentially be used in wearable electronics and healthcare applications.
- Open Access
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 7, 327-332
Fabrication of a probe-lens device for scanning super-resolution imaging platform
We present a simple and flexible approach for building a microsphere-based probe that can be used for a scanning super-resolution imaging platform. We assembled microspheres with a microprobe and manipulate the microspheres as secondary lens across the specimen surface. The achieved resolution enhancement surpasses conventional 100x/0.90 objective lens under white light illumination by adding an additional 4.6x magnification factor, allowing the platform to resolve features as small as 100nm. The work reported here advances the research field of microlens based super-resolution imaging in at least two aspects: 1) development of a process to stably and rapidly bond microspheres (as small as 20μm) on a microprobe for nanoscale scanning in 3D space; 2) realization of large field-of-view (i.e., much large than the field-of-view of a single spherical lens) sub-diffraction limited features by image-patching techniques. We foresee that the device described here can be incorporated with ultra-precision 3D scanning stages to further improve its super-resolution imaging capability in the future.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 7, 327-332
Open AccessFabrication of a probe-lens device for scanning super-resolution imaging platform
We present a simple and flexible approach for building a microsphere-based probe that can be used for a scanning super-resolution imaging platform. We assembled microspheres with a microprobe and manipulate the microspheres as secondary lens across the specimen surface. The achieved resolution enhancement surpasses conventional 100x/0.90 objective lens under white light illumination by adding an additional 4.6x magnification factor, allowing the platform to resolve features as small as 100nm. The work reported here advances the research field of microlens based super-resolution imaging in at least two aspects: 1) development of a process to stably and rapidly bond microspheres (as small as 20μm) on a microprobe for nanoscale scanning in 3D space; 2) realization of large field-of-view (i.e., much large than the field-of-view of a single spherical lens) sub-diffraction limited features by image-patching techniques. We foresee that the device described here can be incorporated with ultra-precision 3D scanning stages to further improve its super-resolution imaging capability in the future.
- Open Access
- 21 October 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (10) , e0165194
Super-Resolution Real Imaging in Microsphere-Assisted Microscopy
Microsphere-assisted microscopy has received a lot of attention recently due to its simplicity and its capability to surpass the diffraction limit. However, to date, sub-diffraction-limit features have only been observed in virtual images formed through the microspheres. We show that it is possible to form real, super-resolution images using high-refractive index microspheres. Also, we report on how changes to a microsphere’s refractive index and size affect image formation and planes. The relationship between the focus position and the additional magnification factor is also investigated using experimental and theoretical methods. We demonstrate that such a real imaging mode, combined with the use of larger microspheres, can enlarge sub-diffraction-limit features up to 10 times that of wide-field microscopy’s magnification with a field-of-view diameter of up to 9 μm.
- 21 October 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (10) , e0165194
Open AccessSuper-Resolution Real Imaging in Microsphere-Assisted Microscopy
Microsphere-assisted microscopy has received a lot of attention recently due to its simplicity and its capability to surpass the diffraction limit. However, to date, sub-diffraction-limit features have only been observed in virtual images formed through the microspheres. We show that it is possible to form real, super-resolution images using high-refractive index microspheres. Also, we report on how changes to a microsphere’s refractive index and size affect image formation and planes. The relationship between the focus position and the additional magnification factor is also investigated using experimental and theoretical methods. We demonstrate that such a real imaging mode, combined with the use of larger microspheres, can enlarge sub-diffraction-limit features up to 10 times that of wide-field microscopy’s magnification with a field-of-view diameter of up to 9 μm.