QLQuang Linh Lam

Quang Linh Lam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Quang Linh Lam has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Advanced control of microgrids for frequency and voltage stability : robust control co-design and real-time validation

    by Quang Linh Lam

    Contrôle avancé pour la stabilité des microréseaux d'énergie : co-conception robuste et validation temps réel: Cette thèse porte sur les problèmes de stabilité en fréquence et en tension des microréseaux isolés avec forte pénétration d'énergies renouvelables en utilisant des dispositifs de stockage d'énergie, et se divise en deux parties principales.Dans la première partie, nous proposons une conception systématique d'une structure de commande robuste multi-variable pour le réglage de fréquence dans un système de génération de puissance hybride diesel-photovoltaïque-supercondensateur fonctionnant en mode autonome. La structure de commande proposée repose sur une architecture à deux niveaux: les contrôleurs d'asservissement de courant basés sur commande PI classique sont placés sur le niveau de commande inférieur et reçoivent des références d'un niveau supérieur qui, lui, est basé sur commande H-infini. Une méthodologie compréhensive qui traduit les demandes d'ingénierie spécifiques de l'opération du microréseau dans le formalisme de commande H-infini est détaillée. Nous montrons également comment les spécifications de performance dynamiques en boucle fermée doivent à leur tour être prises en compte dans la configuration et le dimensionnement initiaux du microréseau, c'est-à-dire en choisissant de manière appropriée et en évaluant le système de stockage d'énergie. Ensuite, une analyse de performance robuste du contrôleur H-infini synthétisé en présence de diverses perturbations de charge, des variations de puissance active de la source photovoltaïque, et des incertitudes du modèle est effectuée afin de déterminer la plage de variation maximale des paramètres pour laquelle les performances de commande imposées sont respectées pour le point de fonctionnement considéré. Les simulations numériques réalisées avec MATLAB/Simulink montrent l'efficacité de la stratégie de commande robuste de fréquence proposée sur un microréseau d'ordre de quelques MVA. Un banc de test de prototypage rapide, qui est composé d'un système de stockage d'énergie réel à base de supercondensateurs et un réseau diesel-photovoltaïque-charge émulé, est développé afin de valider expérimentalement cette stratégie de commande.La deuxième partie de cette thèse se concentre sur le calcul d'un contrôleur de tension multi-variable basé sur commande H-infini afin de forcer robustement l'amplitude de tension du point de couplage commun à satisfaire des spécifications dynamiques. La même idée de la structure de commande à deux niveaux en cascade - où ce contrôleur est placé sur un niveau de commande supérieur et fournit les références de courant aux contrôleurs de courant placés sur un niveau inférieur - est également adoptée. Ensuite, la performance et la robustesse du contrôleur H-infini proposé en présence de diverses perturbations de puissance réactive de la charge et de la source photovoltaïque, ainsi que des incertitudes du modèle, sont étudiées en utilisant des simulations temporelles MATLAB/Simulink.


  • Open Access

    Frequency Robust Control Application in Islanded Microgrids Considering Parametric Uncertainties and Distinct Photovoltaic Penetration Rate Scenarios

    by Quang Linh Lam, Delphine Riu, Antoneta Iuliana Bratcu

    In this paper, a cascaded two-level hybrid control scheme based on multi-variable robust H ∞ and proportional integral control is proposed for primary frequency control of an island mode microgrid consisting of a diesel engine generator, a photovoltaic energy source, an energy storage system, and an aggregated static load. Topological and nonlinear averaged models of each subsystem are introduced, followed by linearized frequency-control-oriented modelling of the entire system. Then, for currents control, conventional proportional-integral-based tracking controllers placed on a lower control level are designed, with their reference values generated from the output of an H ∞-control-based upper level. A comprehensive methodology that casts the specific engineering demands of microgrid operation into the H ∞ control formalism is outlined. Additionally, it is demonstrated how closed-loop dynamic performance requirements must at their turn be taken into account in the initial microgrid setup and sizing, namely in appropriately choosing and rating the energy storage system. Numerical simulations performed with MATLAB®/Simulink® show the validity and effectiveness of the proposed frequency robust control technique in the presence of multiple photovoltaic power step changes on a kVA-rated microgrid. A robust performance analysis of the previously designed H ∞ controller is performed under numerous uncertainty levels in the steady-state value of the supercapacitor state of charge and multiple photovoltaic power step changes to determine if the closed-loop system remains robust from a performance standpoint around its nominal design. The H ∞ control design procedure allows a further investigation on how to link time-domain dynamic performance specifications (e.g., desired control objectives) and frequency-domain specifications (e.g., via so-called weighting functions) in a systematic and optimal manner (i.e., automation for their design or expert modelling), from which an useful guide can be created for practical control engineers in the future. Distinct photovoltaic penetration rate scenarios together with respective computed H ∞ controllers, on the other hand, are examined to determine whether or not an H ∞ optimal control solution that is robust in performance to a variety of photovoltaic power step variations relative to the rated operating point can always be generated.


  • Power hardware-in-the-loop validation of primary frequency robust control in stand-alone microgrids with storage units

    by Quang Linh Lam, Delphine Riu, Antoneta Iuliana Bratcu, Antoine Labonne, Cédric Boudinet


  • Open Access

    Multi-Variable H∞ Control Approach for Voltage Ancillary Service in Autonomous Microgrids: Modelling, Design, and Sensitivity Analysis

    by Quang Linh Lam, Antoneta Iuliana Bratcu, Delphine Riu

    This paper proposes a multi-variable robust control scheme for voltage regulation in a diesel-photovoltaic-supercapacitor hybrid power generation system operating in stand-alone mode. First, we study the influence of system parameters on the dynamic behavior of open-loop system measured outputs by means of a stability analysis method based on Monte Carlo simulation. Next, by applying $\mathcal {H}_{\infty }$ control theory, an $\mathcal {H}_{\infty }$ -based voltage controller is proposed to robustly force the voltage magnitude of a point of common coupling such as to satisfy design specifications. A cascaded two-level control architecture, where this controller acts as an upper control level and provides references to classical PI-based current tracking controllers placed on a lower level, is developed. A comprehensive methodology that casts the specific engineering demands of microgrid operation into an $\mathcal {H}_{\infty }$ control formalism is detailed. Effectiveness of the proposed voltage robust control strategy is validated via MATLAB ® /Simulink ® closed-loop time-domain simulations. Finally, we perform a sensitivity analysis of robust performance of the designed $\mathcal {H}_{\infty }$ controller in the presence of various load disturbances and model uncertainties through a series of closed-loop time-domain simulations carried out in MATLAB ® /Simulink ® .


  • Systematic multi-variable H∞ control design for primary frequency regulation in stand-alone microgrids with high penetration of renewable energy sources

    by Quang Linh Lam, Antoneta Iuliana Bratcu, Delphine Riu

    In this paper, a systematic design of a robust multi-variable control structure for primary frequency regulation in microgrids with high rate of renewable source penetration is proposed. The considered microgrid represents a diesel-photovoltaic-supercapacitor hybrid power generation system operating in stand-alone mode. The proposed control structure relies on a two-level architecture: classical PI-based current tracking controllers are placed on the low control level and receive references from an H ∞ control-based upper level. A comprehensive methodology that casts the specific engineering demands of microgrid operation into H ∞ control formalism is detailed. It is also shown how closed-loop dynamical performance requirements must at their turn be taken into account in the initial microgrid setup and sizing, namely in choosing and rating the energy storage system. Numerical simulations carried out in MATLAB®/Simulink® show the effectiveness of the proposed H ∞ robust control strategy on a MVA-rated microgrid.


  • Multi-variable H-infinity robust control applied to primary frequency regulation in microgrids with large integration of photovoltaic energy source

    by Quang Linh Lam, Antoneta Iuliana Bratcu, Delphine Riu, Jiravan Mongkoltanatas

    In this paper, different control strategies are presented for primary frequency regulation in a diesel-photovoltaic-supercapacitor hybrid power generation system. Firstly, a classical control approach is proposed as a reference. Then, a robust control design based on H ∞ control theory is applied to the studied system. Starting from given certain desired performances, Linear Matrix Inequalities (LMI) are used to solve the H ∞ controller design problem. In the second step, several modeling uncertainties are included and μ-analysis is carried out to determine the maximum variation range of each uncertainty for which the system is still stable and desired performances are met. Numerical simulation results show the effectiveness of the H ∞ robust control strategy when compared with the classical control strategy used for this type of hybrid power generation system.