MUMaurizio Ungaro

Maurizio Ungaro

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maurizio Ungaro has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Geant4 Monte-Carlo (GEMC) A database-driven simulation program

    by Maurizio Ungaro

    GEMC[1] is an application that harnesses the power of databases to execute Geant4 Monte-Carlo simulations.The databases (MYSQL, CSQL, TEXT) define the geometry, materials, digitization algorithms, readout electronics and output formats.Implemented in C++, GEMC also boasts a user-friendly Python API that facilitates detector construction and database population.GEMC can handle real-life scenarios such as geometry variations and the run number-dependent calibration constants and digitization parameters.This abstract provides an overview of GEMC, accompanied by examples that showcase its versatility. We delve into the practical application of GEMC within the the CLAS12 experimental program at Jefferson Lab.


  • The CLAS12 Low Threshold Cherenkov detector

    by M. Ungaro, D. Anderson, G. Asryan, M.A. Antonioli, P. Bonneau, V.D. Burkert, S. Christo, M. Cook, B. Duran, B. Eng, et al.


  • Open Access

    Enhanced UV light detection using a p-terphenyl wavelength shifter

    by S. Joosten, E. Kaczanowicz, M. Ungaro, M. Rehfuss, K. Johnston, Z. -E. Meziani

    UV-glass photomultiplier tubes (PMTs) have poor photon detection efficiency for wavelengths below $300\,\text{nm}$ due to the opaqueness of the window material. Costly quartz PMTs could be used to enhance the efficiency below $300\,\text{nm}$. A less expensive solution that dramatically improves this efficiency is the application of a thin film of a p-terphenyl (PT) wavelength shifter on UV-glass PMTs. This improvement was quantified for Photonis XP4500B PMTs for wavelengths between $200\,\text{nm}$ and $400\,\text{nm}$. The gain factor ranges up to 5.4 $\pm$ 0.5 at a wavelength of $215\,\text{nm}$, with a material load of $110\pm10\,\mu\text{g}/\text{cm}^2$ ($894\,\text{nm}$). The wavelength shifter was found to be fully transparent for wavelengths greater than $300\,\text{nm}$. The resulting gain in detection efficiency, when used in a typical Cherenkov counter, was estimated to be of the order of 40\%. Consistent coating quality was assured by a rapid gain testing procedure using narrow-band UV LEDs. Based on these results, 200 Photonis XP4500B PMTs were treated with PT for the upgraded low-threshold Cherenkov counter (LTCC) to be used in the CEBAF Large Acceptance Spectrometer upgraded detector (CLAS12) at the Thomas Jefferson National Accelerator Facility.