Alexandra M. Hart
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexandra M. Hart has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Albert Losken
Division of Plastic Surgery, Emory University School of Medicine, Atlanta, Georgia
3 shared publicationsAlbert Md Losken
Private Practice, Atlanta, GA
1 shared publicationClaire Duggal
Emory University School of Medicine, Atlanta, GA, USA
1 shared publicationEugenia K. Page
Private Practice, Atlanta, GA
1 shared publicationGrant W. Carlson
Division of Plastic Surgery, Emory University School of Medicine, Atlanta, Georgia
1 shared publication- Grant W. Carlson
Division of Plastic Surgery, Emory University School of Medicine, USA
1 shared publication
Latest Publications
- 10 January 2020
- Published by Hindawi Limited in The Breast Journal
- Vol. 26 (7) , 1270-1275
Nipple malposition after bilateral nipple‐sparing mastectomy with implant‐based reconstruction: Objective postoperative analysis utilizing BCCT.core computer software
Nipple‐sparing mastectomies (NSMs) are accepted as safe oncologic procedures for select patient populations, but objective evaluation of aesthetic outcomes has not been clearly established. The purpose of this study was to utilize BCCT.core computer software to objectively evaluate NAC malposition following bilateral NSM with implant reconstruction and compare the analysis to an expert panel. Postoperative photographs of 43 patients who underwent bilateral NSM were analyzed with the BCCT.core and by an expert panel of plastic surgery residents and attendings. The panel was asked to only evaluate nipple asymmetry and position. The intraclass correlation coefficient (ICC) was used to determine interrater reliability (n = 12) and between expert panel ratings and BCCT.core ratings. Statistics were performed using SPSS statistical package version 24.0. The ICC for the expert panel interrater reliability was excellent (ICC = 0.941, 95% CI: 0.912‐0.964). The analysis between BCCT.core individual parameters, specifically the breast retraction assessment (ie, BRA score = the difference in nipple position between the two breasts assessing breast symmetry) and expert panel, showed statistically significant positive correlation. The parameters provided by the BCCT.core software were correlated with both the mean expert panel rating and BCCT.core ratings. Therefore, it is plausible that BCCT.core parameters could be used to objectively quantify NAC malposition/asymmetry and guide treatment in patients undergoing bilateral NSM with implant reconstruction.
- 10 January 2020
- Published by Hindawi Limited in The Breast Journal
- Vol. 26 (7) , 1270-1275
Nipple malposition after bilateral nipple‐sparing mastectomy with implant‐based reconstruction: Objective postoperative analysis utilizing BCCT.core computer software
Nipple‐sparing mastectomies (NSMs) are accepted as safe oncologic procedures for select patient populations, but objective evaluation of aesthetic outcomes has not been clearly established. The purpose of this study was to utilize BCCT.core computer software to objectively evaluate NAC malposition following bilateral NSM with implant reconstruction and compare the analysis to an expert panel. Postoperative photographs of 43 patients who underwent bilateral NSM were analyzed with the BCCT.core and by an expert panel of plastic surgery residents and attendings. The panel was asked to only evaluate nipple asymmetry and position. The intraclass correlation coefficient (ICC) was used to determine interrater reliability (n = 12) and between expert panel ratings and BCCT.core ratings. Statistics were performed using SPSS statistical package version 24.0. The ICC for the expert panel interrater reliability was excellent (ICC = 0.941, 95% CI: 0.912‐0.964). The analysis between BCCT.core individual parameters, specifically the breast retraction assessment (ie, BRA score = the difference in nipple position between the two breasts assessing breast symmetry) and expert panel, showed statistically significant positive correlation. The parameters provided by the BCCT.core software were correlated with both the mean expert panel rating and BCCT.core ratings. Therefore, it is plausible that BCCT.core parameters could be used to objectively quantify NAC malposition/asymmetry and guide treatment in patients undergoing bilateral NSM with implant reconstruction.
- Open Access
- 1 July 2016
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 4 (7) , e800
A Complication Analysis of 2 Acellular Dermal Matrices in Prosthetic-based Breast Reconstruction
Background: Acellular dermal matrices (ADM) are now routine in postmastectomy prosthetic-based breast reconstruction. The goal of the current study was to compare the complications of 2 ADM products—AlloDerm and Cortiva. Methods: A retrospective analysis of prosthetic-based breast reconstruction in Atlanta, Ga., over 5 years. Inclusion criteria were the use of the ADM types (AlloDerm or Cortiva) and use of a tissue expander or implant. Statistical analysis compared group demographics, risk factors, and early complications. Results: Of the 298 breast reconstructions, 174 (58.4%) used AlloDerm and 124 (41.6%) used Cortiva. There was no difference in overall complication frequency (16 AlloDerm and 18 Cortiva; P = 0.195). Within specific categories, there was a difference in mastectomy skin flap necrosis, but, based on further regression analysis, this was attributable to differences in body mass index (P = 0.036). Furthermore, there were no differences in the rates of infection (6 AlloDerm and 5 Cortiva; P = 1.0), seroma/hematoma (9 AlloDerm and 7 Cortiva; P = 1.0), or drain duration (13.2 day AlloDerm and 14.2 day Cortiva, P = 0.2). By using a general estimating equation for binomial logistical regression, it was found that only current tobacco use (P = 0.033) was a significant predictor for a complication. Trending predictors were body mass index (P = 0.074) and age (P = 0.093). The type of matrix was not a significant predictor for any of the recorded complication (P = 0.160). Conclusions: Although AlloDerm is well established, we have shown that Cortiva has an equivalent complication frequency. Future work will focus on long-term outcome measures and histological evaluation of vascularization and integration.
- 1 July 2016
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 4 (7) , e800
Open AccessA Complication Analysis of 2 Acellular Dermal Matrices in Prosthetic-based Breast Reconstruction
Background: Acellular dermal matrices (ADM) are now routine in postmastectomy prosthetic-based breast reconstruction. The goal of the current study was to compare the complications of 2 ADM products—AlloDerm and Cortiva. Methods: A retrospective analysis of prosthetic-based breast reconstruction in Atlanta, Ga., over 5 years. Inclusion criteria were the use of the ADM types (AlloDerm or Cortiva) and use of a tissue expander or implant. Statistical analysis compared group demographics, risk factors, and early complications. Results: Of the 298 breast reconstructions, 174 (58.4%) used AlloDerm and 124 (41.6%) used Cortiva. There was no difference in overall complication frequency (16 AlloDerm and 18 Cortiva; P = 0.195). Within specific categories, there was a difference in mastectomy skin flap necrosis, but, based on further regression analysis, this was attributable to differences in body mass index (P = 0.036). Furthermore, there were no differences in the rates of infection (6 AlloDerm and 5 Cortiva; P = 1.0), seroma/hematoma (9 AlloDerm and 7 Cortiva; P = 1.0), or drain duration (13.2 day AlloDerm and 14.2 day Cortiva, P = 0.2). By using a general estimating equation for binomial logistical regression, it was found that only current tobacco use (P = 0.033) was a significant predictor for a complication. Trending predictors were body mass index (P = 0.074) and age (P = 0.093). The type of matrix was not a significant predictor for any of the recorded complication (P = 0.160). Conclusions: Although AlloDerm is well established, we have shown that Cortiva has an equivalent complication frequency. Future work will focus on long-term outcome measures and histological evaluation of vascularization and integration.
- 1 October 2015
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 221 (4) , e123
The impact of mesh reinforcement with components separation for abdominal wall reconstruction
- 1 October 2015
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 221 (4) , e123
The impact of mesh reinforcement with components separation for abdominal wall reconstruction
- 1 April 2015
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 135, 1202
Abstract 48
- 1 April 2015
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 135, 1202
Abstract 48