Karthik Ramanathan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Karthik Ramanathan has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
- Sunil R. Golwala
Division of Physics, Mathematics, and Astronomy, California Institute of Technology, Pasadena, CA, USA
5 shared publications Taylor Aralis
Kavli Institute for Particle Astrophysics and Cosmology, SLAC National Laboratory, Menlo Park, CA, USA
5 shared publicationsYen-Yung Chang
Division of Physics, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
5 shared publications- Brandon J. Sandoval
California Institute of Technology
3 shared publications Bruce Bumble
Jet Propulsion Laboratory California Institute of Technology 91109 Pasadena CA USA
3 shared publications- Noah Kurinsky
SLAC National Accelerator Laboratory
3 shared publications
Latest Publications
- 21 November 2026
- Published by Elsevier in Physics of the Dark Universe
Towards LLM-Powered Automation of a Dark Matter Constraint Repository
- 21 November 2026
- Published by Elsevier in Physics of the Dark Universe
Towards LLM-Powered Automation of a Dark Matter Constraint Repository
- Open Access
- 1 May 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (05) , P05025
Significant noise improvement in a Kinetic Inductance Phonon-Mediated detector by use of a wideband parametric amplifier
Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon-Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers, are oftentimes limited in their sensitivity by low temperature amplifier noise introduced in the signal readout chain. We report here an effort to couple a wideband Kinetic Inductance Traveling Wave Parametric Amplifier (KI-TWPA), operated near the Standard Quantum Limit of minimal added amplifier noise, to sensors spanning a 70 MHz bandwidth at 3.5 GHz. This results in a ∼ 5× improvement in the inferred detector energy resolution in the best sensor and highlights the potential of constructing 𝒪(100) meV resolving phonon-mediated particle detectors. We detail limitations introduced by lossy passive components, degraded RF responsivity, and microphysical noise sources like two-level systems (TLS), in achieving ultimate quantum-limited system noise levels.
- 1 May 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (05) , P05025
Open AccessSignificant noise improvement in a Kinetic Inductance Phonon-Mediated detector by use of a wideband parametric amplifier
Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon-Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers, are oftentimes limited in their sensitivity by low temperature amplifier noise introduced in the signal readout chain. We report here an effort to couple a wideband Kinetic Inductance Traveling Wave Parametric Amplifier (KI-TWPA), operated near the Standard Quantum Limit of minimal added amplifier noise, to sensors spanning a 70 MHz bandwidth at 3.5 GHz. This results in a ∼ 5× improvement in the inferred detector energy resolution in the best sensor and highlights the potential of constructing 𝒪(100) meV resolving phonon-mediated particle detectors. We detail limitations introduced by lossy passive components, degraded RF responsivity, and microphysical noise sources like two-level systems (TLS), in achieving ultimate quantum-limited system noise levels.
- Open Access
- 1 May 2026
- Published by American Physical Society (APS) in APS Open Science
- Vol. 1, 000013
Quantum parity detectors: A qubit-based particle-detection scheme with meV thresholds for rare-event searches
The next generation of rare-event searches, such as those aimed at determining the nature of particle dark matter or measuring fundamental neutrino properties, will benefit from particle detectors with thresholds at the meV scale, $100--1000\ifmmode\times\else\texttimes\fi{}$ lower than currently available. Quantum parity detectors (QPDs) are a class of proposed quantum devices, extending recent work on superconducting qubit sensors, that exploit the fingerprints of single quasiparticle tunneling across a coherent weak link as their detection concept. As envisioned, phonons generated by particle interactions within a crystalline substrate cause an eventual quasiparticle cascade within a surface-patterned superconducting qubit element. This process alters the fundamental charge parity of the device in a binary manner, which can be used to deduce the initial properties of the energy deposition. This work lays out multiple resonator-coupled readout schemes depending on qubit architecture, provides an analytic formulation for reconstructing sensor energies, and details strategies for multiplexing large arrays of sensors. We further compute the sensitivity of QPDs and detail an R pathway to demonstrating sub-eV energy deposit thresholds.- 1 May 2026
- Published by American Physical Society (APS) in APS Open Science
- Vol. 1, 000013
Open AccessQuantum parity detectors: A qubit-based particle-detection scheme with meV thresholds for rare-event searches
The next generation of rare-event searches, such as those aimed at determining the nature of particle dark matter or measuring fundamental neutrino properties, will benefit from particle detectors with thresholds at the meV scale, $100--1000\ifmmode\times\else\texttimes\fi{}$ lower than currently available. Quantum parity detectors (QPDs) are a class of proposed quantum devices, extending recent work on superconducting qubit sensors, that exploit the fingerprints of single quasiparticle tunneling across a coherent weak link as their detection concept. As envisioned, phonons generated by particle interactions within a crystalline substrate cause an eventual quasiparticle cascade within a surface-patterned superconducting qubit element. This process alters the fundamental charge parity of the device in a binary manner, which can be used to deduce the initial properties of the energy deposition. This work lays out multiple resonator-coupled readout schemes depending on qubit architecture, provides an analytic formulation for reconstructing sensor energies, and details strategies for multiplexing large arrays of sensors. We further compute the sensitivity of QPDs and detail an R pathway to demonstrating sub-eV energy deposit thresholds. - 29 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 2402006
Assessing the Operating Characteristics of an Ion-Milled Phonon-Mediated Quantum Parity Detector
Phonon sensitive superconducting qubits are a promising technology to detect sub-eV energy deposits within macroscopic crystalline targets, useful for future rare-event search experiments looking for interactions from dark matter and neutrinos. We detail here engineering results from a Quantum Parity Detector (QPDs), one of a class of phonon sensitive qubits, and, as a first measurement, show that this device has a quiescent quasiparticle density of $1.8 \pm 0.8 \mu \mathrm{m}^{-3}$, in line with expectation. We also outline an argon ion-mill process for multi-step Josephson Junction fabrication, expanding the sparse literature on this topic, which proves useful in avoiding secondary parasitic junctions.
- 29 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 2402006
Assessing the Operating Characteristics of an Ion-Milled Phonon-Mediated Quantum Parity Detector
Phonon sensitive superconducting qubits are a promising technology to detect sub-eV energy deposits within macroscopic crystalline targets, useful for future rare-event search experiments looking for interactions from dark matter and neutrinos. We detail here engineering results from a Quantum Parity Detector (QPDs), one of a class of phonon sensitive qubits, and, as a first measurement, show that this device has a quiescent quasiparticle density of $1.8 \pm 0.8 \mu \mathrm{m}^{-3}$, in line with expectation. We also outline an argon ion-mill process for multi-step Josephson Junction fabrication, expanding the sparse literature on this topic, which proves useful in avoiding secondary parasitic junctions.
- 9 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-8
Development Status of the KIPM Detector Consortium
A Kinetic Inductance Phonon-Mediated Detector is a calorimeter that uses kinetic inductance detectors (KIDs) to read out phonon signals from the device substrate. We have established a consortium comprising university and national lab groups dedicated to advancing the state of the art in these detectors, with the ultimate goal of designing a detector with sub-eV threshold on energy deposited in the substrate, enabling searches for both light dark matter and low-energy neutrino interactions. This consortium brings together experts in kinetic inductance detector design, phonon and quasiparticle dynamics, and noise modeling, along with specialized fabrication facilities, test platforms, and unique calibration capabilities. Recently, our consortium has demonstrated a resolution on energy absorbed by the sensor of 2.1 eV, the current record for phonon-sensitive KIDs, though due to ∼ 1% phonon collection efficiency, the overall detector resolution was limited to 320eV. The current focus of the consortium is modeling and improving the phonon collection efficiency and implementing low-Tc superconductors, both of which serve to improve the overall energy resolution and threshold of the detectors. FNAL Report Number: FERMILAB-PUB-25-0652-ETD
- 9 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-8
Development Status of the KIPM Detector Consortium
A Kinetic Inductance Phonon-Mediated Detector is a calorimeter that uses kinetic inductance detectors (KIDs) to read out phonon signals from the device substrate. We have established a consortium comprising university and national lab groups dedicated to advancing the state of the art in these detectors, with the ultimate goal of designing a detector with sub-eV threshold on energy deposited in the substrate, enabling searches for both light dark matter and low-energy neutrino interactions. This consortium brings together experts in kinetic inductance detector design, phonon and quasiparticle dynamics, and noise modeling, along with specialized fabrication facilities, test platforms, and unique calibration capabilities. Recently, our consortium has demonstrated a resolution on energy absorbed by the sensor of 2.1 eV, the current record for phonon-sensitive KIDs, though due to ∼ 1% phonon collection efficiency, the overall detector resolution was limited to 320eV. The current focus of the consortium is modeling and improving the phonon collection efficiency and implementing low-Tc superconductors, both of which serve to improve the overall energy resolution and threshold of the detectors. FNAL Report Number: FERMILAB-PUB-25-0652-ETD
- 18 October 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 22 (4)
Performance of a phonon-mediated kinetic inductance detector at the NEXUS cryogenic facility
- 18 October 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 22 (4)
Performance of a phonon-mediated kinetic inductance detector at the NEXUS cryogenic facility
- Open Access
Significant noise improvement in a Kinetic Inductance Phonon-Mediated detector by use of a wideband parametric amplifier
Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers, are oftentimes limited in their sensitivity by low temperature amplifier noise introduced in the signal readout chain. We report here an effort to couple a wideband Kinetic Inductance Travelling Wave Parametric Amplifier (KI-TWPA), operated near the Standard Quantum Limit of minimal added amplifier noise, to sensors spanning a 70 MHz bandwidth at 3.5 GHz. This results in a ~5x improvement in the inferred detector energy resolution in the best sensor and highlights the potential of constructing O(100) meV resolving phonon-mediated particle detectors. We detail limitations introduced by lossy passive components, degraded RF responsivity, and microphysical noise sources like two-level systems (TLS), in achieving ultimate quantum-limited system noise levels.
Open AccessSignificant noise improvement in a Kinetic Inductance Phonon-Mediated detector by use of a wideband parametric amplifier
Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers, are oftentimes limited in their sensitivity by low temperature amplifier noise introduced in the signal readout chain. We report here an effort to couple a wideband Kinetic Inductance Travelling Wave Parametric Amplifier (KI-TWPA), operated near the Standard Quantum Limit of minimal added amplifier noise, to sensors spanning a 70 MHz bandwidth at 3.5 GHz. This results in a ~5x improvement in the inferred detector energy resolution in the best sensor and highlights the potential of constructing O(100) meV resolving phonon-mediated particle detectors. We detail limitations introduced by lossy passive components, degraded RF responsivity, and microphysical noise sources like two-level systems (TLS), in achieving ultimate quantum-limited system noise levels.
- 9 June 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 130 (23) , 231001
Wideband Direct Detection Constraints on Hidden Photon Dark Matter with the QUALIPHIDE Experiment
We report direction detection constraints on the presence of hidden photon dark matter with masses between , using a cryogenic emitter-receiver-amplifier spectroscopy setup designed as the first iteration of QUALIPHIDE (quantum limited photons in the dark experiment). A metallic dish sources conversion photons, from hidden photon kinetic mixing, onto a horn antenna which is coupled to a band kinetic inductance traveling wave parametric amplifier, providing for near quantum-limited noise performance. We demonstrate a first probing of the kinetic mixing parameter to the level for the majority of hidden photon masses in this region. These results not only represent stringent constraints on new dark matter parameter space, but are also the first demonstrated use of wideband quantum-limited amplification for astroparticle applications.- 9 June 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 130 (23) , 231001
Wideband Direct Detection Constraints on Hidden Photon Dark Matter with the QUALIPHIDE Experiment
We report direction detection constraints on the presence of hidden photon dark matter with masses between , using a cryogenic emitter-receiver-amplifier spectroscopy setup designed as the first iteration of QUALIPHIDE (quantum limited photons in the dark experiment). A metallic dish sources conversion photons, from hidden photon kinetic mixing, onto a horn antenna which is coupled to a band kinetic inductance traveling wave parametric amplifier, providing for near quantum-limited noise performance. We demonstrate a first probing of the kinetic mixing parameter to the level for the majority of hidden photon masses in this region. These results not only represent stringent constraints on new dark matter parameter space, but are also the first demonstrated use of wideband quantum-limited amplification for astroparticle applications.- Open Access
Identifying drivers of energy resolution variation in multi-KID phonon-mediated detectors
Phonon-mediated particle detectors employing Kinetic Inductance Detectors (KIDs) on Silicon substrates have demonstrated both O(10) eV energy resolution and mm position resolution, making them strong candidates for instrumenting next generation rare-event experiments such as in looking for dark matter or in neutrino measurements. Previous work has demonstrated the performance of an 80-KID array on a Si wafer, however current energy resolution measurements show a 25x difference between otherwise identical KIDs on the same wafer - between 5 to 125 eV on energy absorbed by the KID. Here, we use a first principles approach and attempt to identify the drivers behind the resolution variation. In particular, we analyze a subset of 8 KIDs using the unique approach of pulsing neighboring KIDs to generate signals in the target. We tentatively identify differences in quality factor terms as the likely culprit for the observed variation.
Open AccessIdentifying drivers of energy resolution variation in multi-KID phonon-mediated detectors
Phonon-mediated particle detectors employing Kinetic Inductance Detectors (KIDs) on Silicon substrates have demonstrated both O(10) eV energy resolution and mm position resolution, making them strong candidates for instrumenting next generation rare-event experiments such as in looking for dark matter or in neutrino measurements. Previous work has demonstrated the performance of an 80-KID array on a Si wafer, however current energy resolution measurements show a 25x difference between otherwise identical KIDs on the same wafer - between 5 to 125 eV on energy absorbed by the KID. Here, we use a first principles approach and attempt to identify the drivers behind the resolution variation. In particular, we analyze a subset of 8 KIDs using the unique approach of pulsing neighboring KIDs to generate signals in the target. We tentatively identify differences in quality factor terms as the likely culprit for the observed variation.
- 8 June 2022
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 209 (3-4) , 457-463
Identifying Drivers of Energy Resolution Variation in a Multi-KID Phonon-Mediated Detector
- 8 June 2022
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 209 (3-4) , 457-463
Identifying Drivers of Energy Resolution Variation in a Multi-KID Phonon-Mediated Detector