Vipul M. Bhojawala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vipul M. Bhojawala has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Dhaval V. Patel
Nirma University
6 shared publications D. P. Vakharia
Department of Mechanical Engineering, Sardar Vallabhbhai National Institute of Technology, Surat, India
3 shared publications- Kaushik M. Patel
Institute of Technology, Nirma University
3 shared publications Ankur Pandya
Department of Physics under Department of Electronics and Communications, Institute of Technology, Nirma University, Ahmedabad, Gujarat 382481, India
1 shared publication- Dhaval B. Shah
Nirma University
1 shared publication - Dipak Vakharia
Department of Mechanical Engineering, S. V. National Institute of Technology (SVNIT), Icchahanath, Surat 395007, Gujarat, India
1 shared publication
Latest Publications
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2931 (1) , 100035
Anomaly detection in rolling element bearing using spectral dissimilarity index approach
Rolling element bearings are important members of rotating machines. The undetected faults in the rolling element bearings cause disastrous failure of entire sy
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2931 (1) , 100035
Open AccessAnomaly detection in rolling element bearing using spectral dissimilarity index approach
Rolling element bearings are important members of rotating machines. The undetected faults in the rolling element bearings cause disastrous failure of entire sy
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2764 (1)
Design and analysis of belly mounted liquefied natural gas semitrailer
The aim of this work is to compare the stress distributions of inner vessel shell, and head, outer vessel shell and head, kingpin junctions at outer vessel and running gear assembly at outer vessel junctions for LNG semitrailer for lateral lading conditions. The ASME section VIII division I and Specification for Insulated Cargo Tank (CGA-341) for Nonflammable Cryogenic Liquids) areused for design of inner vessel and outer vessel respectively. The inner vessel is designed considering the design parameter 7 bar pressure and-162⁰C of design temperature whereas for outer vessel the design parameter is considered as ambient pressureand temperature condition.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2764 (1)
Open AccessDesign and analysis of belly mounted liquefied natural gas semitrailer
The aim of this work is to compare the stress distributions of inner vessel shell, and head, outer vessel shell and head, kingpin junctions at outer vessel and running gear assembly at outer vessel junctions for LNG semitrailer for lateral lading conditions. The ASME section VIII division I and Specification for Insulated Cargo Tank (CGA-341) for Nonflammable Cryogenic Liquids) areused for design of inner vessel and outer vessel respectively. The inner vessel is designed considering the design parameter 7 bar pressure and-162⁰C of design temperature whereas for outer vessel the design parameter is considered as ambient pressureand temperature condition.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2764 (1)
Design of anti-fall mechanism for the longitudinal seam welding station
The objective of the current work is to design a safety mechanism for the longitudinal seam welding station. Longitudinal seam welding station is welding fixture used in the fabrication of the pressure vessel for the welding of cylindrical shell along the length of the shell. In the design of long seam welding station it is necessary to incorporate anti-fall mechanism. The safety mechanism included in the design of welding station for preventing the accident owing to the failure of while lifting the components is known as anti-fall mechanism. Anti-fall mechanism remains inactive during normal running operation and it will engage with the rack, when lifting mechanism fails.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2764 (1)
Open AccessDesign of anti-fall mechanism for the longitudinal seam welding station
The objective of the current work is to design a safety mechanism for the longitudinal seam welding station. Longitudinal seam welding station is welding fixture used in the fabrication of the pressure vessel for the welding of cylindrical shell along the length of the shell. In the design of long seam welding station it is necessary to incorporate anti-fall mechanism. The safety mechanism included in the design of welding station for preventing the accident owing to the failure of while lifting the components is known as anti-fall mechanism. Anti-fall mechanism remains inactive during normal running operation and it will engage with the rack, when lifting mechanism fails.
- 9 December 2022
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 11 (8) , 3859-3878
Rolling Element Bearing Fault Diagnosis Using an Integrated Approach Incorporating Teager–Kaiser Energy Operator and Singular Spectrum Analysis
- 9 December 2022
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 11 (8) , 3859-3878
Rolling Element Bearing Fault Diagnosis Using an Integrated Approach Incorporating Teager–Kaiser Energy Operator and Singular Spectrum Analysis
- 1 December 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (3) , 035601
Size estimation of spall-like fault on rolling element bearing using an integrated approach incorporating total variation regularization and singular spectrum analysis
Spalling in rolling element bearings is a common localized defect generated during the operation of a bearing due to rolling fatigue. Size estimation of such localized defects can be helpful in determining the severity of the fault. This can be further used as an input for predicting the remaining useful life of the bearing. The popular approach for estimating the size (in terms of width) of a spall is to trace the entry and exit events of the rolling element while interacting with the fault. The time estimated between entry and exit of a rolling element from a pit-like spall can be converted to a geometric estimation of the fault size from the vibration signature. The present approach demonstrates the use of singular spectrum analysis (SSA) to accomplish this task. The vibration signal generated from the interaction of the rolling element with the localized fault is a hybrid signal consisting of a low frequency stepped response generated while the rolling element enters the fault superimposed onto the high frequency impact generated during the re-entry of the rolling element into the raceway from the spall. The signal information is enhanced via pre-processing with total variation regularization (TVR) filtration. The informative signal, which is extracted from the row temporal signal via SSA, aids in the accurate identification of entry and exit events. The proposed method integrating TVR with SSA for fault size estimation is validated using simulated signals and experimental signals from independent resources. The results show strong agreement with the accuracy level of size estimation.
- 1 December 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (3) , 035601
Size estimation of spall-like fault on rolling element bearing using an integrated approach incorporating total variation regularization and singular spectrum analysis
Spalling in rolling element bearings is a common localized defect generated during the operation of a bearing due to rolling fatigue. Size estimation of such localized defects can be helpful in determining the severity of the fault. This can be further used as an input for predicting the remaining useful life of the bearing. The popular approach for estimating the size (in terms of width) of a spall is to trace the entry and exit events of the rolling element while interacting with the fault. The time estimated between entry and exit of a rolling element from a pit-like spall can be converted to a geometric estimation of the fault size from the vibration signature. The present approach demonstrates the use of singular spectrum analysis (SSA) to accomplish this task. The vibration signal generated from the interaction of the rolling element with the localized fault is a hybrid signal consisting of a low frequency stepped response generated while the rolling element enters the fault superimposed onto the high frequency impact generated during the re-entry of the rolling element into the raceway from the spall. The signal information is enhanced via pre-processing with total variation regularization (TVR) filtration. The informative signal, which is extracted from the row temporal signal via SSA, aids in the accurate identification of entry and exit events. The proposed method integrating TVR with SSA for fault size estimation is validated using simulated signals and experimental signals from independent resources. The results show strong agreement with the accuracy level of size estimation.
- 22 April 2022
- Published by Springer Nature
- p. 427-437
Evaluation of Alternate Material of a Bush for Reducing Fretting Wear Damage in a Bush-Pin Joint
- 22 April 2022
- Published by Springer Nature
- p. 427-437
Evaluation of Alternate Material of a Bush for Reducing Fretting Wear Damage in a Bush-Pin Joint
- 1 December 2017
- Published by IOP Publishing in Materials Research Express
- Vol. 4 (12) , 126306
Closed-form solution for static pull-in voltage of electrostatically actuated clamped–clamped micro/nano beams under the effect of fringing field and van der Waals force
This investigation provides an accurate prediction of static pull-in voltage for clamped–clamped micro/nano beams based on distributed model. The Euler–Bernoulli beam theory is used adapting geometric non-linearity of beam, internal (residual) stress, van der Waals force, distributed electrostatic force and fringing field effects for deriving governing differential equation. The Galerkin discretisation method is used to make reduced-order model of the governing differential equation. A regime plot is presented in the current work for determining the number of modes required in reduced-order model to obtain completely converged pull-in voltage for micro/nano beams. A closed-form relation is developed based on the relationship obtained from curve fitting of pull-in instability plots and subsequent non-linear regression for the proposed relation. The output of regression analysis provides Chi-square (χ 2) tolerance value equals to 1 × 10−9, adjusted R-square value equals to 0.999 29 and P-value equals to zero, these statistical parameters indicate the convergence of non-linear fit, accuracy of fitted data and significance of the proposed model respectively. The closed-form equation is validated using available data of experimental and numerical results. The relative maximum error of 4.08% in comparison to several available experimental and numerical data proves the reliability of the proposed closed-form equation.
- 1 December 2017
- Published by IOP Publishing in Materials Research Express
- Vol. 4 (12) , 126306
Closed-form solution for static pull-in voltage of electrostatically actuated clamped–clamped micro/nano beams under the effect of fringing field and van der Waals force
This investigation provides an accurate prediction of static pull-in voltage for clamped–clamped micro/nano beams based on distributed model. The Euler–Bernoulli beam theory is used adapting geometric non-linearity of beam, internal (residual) stress, van der Waals force, distributed electrostatic force and fringing field effects for deriving governing differential equation. The Galerkin discretisation method is used to make reduced-order model of the governing differential equation. A regime plot is presented in the current work for determining the number of modes required in reduced-order model to obtain completely converged pull-in voltage for micro/nano beams. A closed-form relation is developed based on the relationship obtained from curve fitting of pull-in instability plots and subsequent non-linear regression for the proposed relation. The output of regression analysis provides Chi-square (χ 2) tolerance value equals to 1 × 10−9, adjusted R-square value equals to 0.999 29 and P-value equals to zero, these statistical parameters indicate the convergence of non-linear fit, accuracy of fitted data and significance of the proposed model respectively. The closed-form equation is validated using available data of experimental and numerical results. The relative maximum error of 4.08% in comparison to several available experimental and numerical data proves the reliability of the proposed closed-form equation.
- 18 April 2017
- Published by Springer Nature in Acta Mechanica
- Vol. 228 (7) , 2583-2602
Closed-form relation to predict static pull-in voltage of an electrostatically actuated clamped–clamped microbeam under the effect of Casimir force
- 18 April 2017
- Published by Springer Nature in Acta Mechanica
- Vol. 228 (7) , 2583-2602
Closed-form relation to predict static pull-in voltage of an electrostatically actuated clamped–clamped microbeam under the effect of Casimir force