WZWeiding Zhuo

Weiding Zhuo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Weiding Zhuo has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fatigue damage model for precast bridge piers reinforced with high-strength rebar

    by Weiding Zhuo, Saiyang Zhuo, Suiwen Wu, Yiyang Hua, Zhao Liu, Teng Tong

  • Transverse Post-Tensioning in Long-Span Concrete Box-Girder Bridges: Refined Modeling and Alternative System

    by Zhi-Qi He, Weiding Zhuo, Yedong Jiang, Shixiang Zhang, Zhao Liu, Zhongguo John Ma

    Transverse post-tensioning is commonly introduced in top slabs of concrete box girders to control transverse tensile stresses induced by dead and live wheel loads. However, longitudinal cracks with a definite pattern have occurred time and again on the bottom of top slabs. This unexpected cracking distress urges a reevaluation of the structural effect of transverse prestressing. First, a step-by-step three-dimensional (3D) modeling was employed to simulate the balanced cantilever construction of box-girder bridges. It was found that the stressing sequence of transverse tendons has a significant influence on the slab prestress distribution along the bridge. The commonly adopted immediate tensioning method (referring to stressing transverse tendons in segment i immediately after the casting and hardening of segment i ) yields a ±40% fluctuation of slab prestress within each segment, resulting in much lower prestress near the segment’s rear joint, where cracks are easily occurred. In contrast, the delayed tensioning method (referring to stressing transverse tendons in segment i after the casting and hardening of segment i+1 ) will greatly alleviate the nonuniform distribution. Second, an explicit equation based on an analytical model is proposed for calculating the slab transverse prestress. To overcome the problem of large friction losses in the current flat anchorage (FA) system, an alternative single-large-strand (SLS) system was designed and its performance verified by full-scale comparative tests. The test results show that the friction loss of the SLS system is only one-third of the FA system, and the overall structural efficiency can be increased by 20%.


  • Seismic Evaluation of Precast Piers with Different Rebar Strength Based on Characterized Resilience Parameters

    by Weiding Zhuo, Zhao Liu, Zhiqi He, Jiandong Zhang

    The use of precast pier segments is an integral part of many accelerated bridge construction efforts. To effectively compensate for the adverse effect caused by the concrete discontinuity between precast segments, replacing conventional rebar with high-strength steel (HSS) rebar can be an alternative to this issue. However, the primary interest in design practice is how to evaluate the seismic performance of precast piers with different rebar strength. To this end, a seismic evaluation method based on the four characterized resilience parameters was developed, which related to energy consumption, stiffness degradation, residual displacement, and drift capacity. According to the physical significance of the parameters, their desired expectations were expounded. In order to investigate the impact of rebar strength, an experimental program of the two precast piers was conducted, and the hysteretic curves were obtained. By comparatively analyzing the envelope curves of the two precast piers, the characterized resilience parameters were calculated and evaluated. It conclusively showed that the precast pier with HSS rebar was better than the one with conventional rebar at large. The proposed method based on the characterized resilience parameters is an effective tool to evaluate the seismic performance of bridge piers.


  • Open Access

    Comparison study on hysteretic energy dissipation and displacement components between cast‐in‐place and precast piers with high‐strength bars

    by Wei‐Ding Zhuo, Zhao Liu, Jian‐Dong Zhang, Wen‐Ming Zhang

    Precast piers incorporated with high‐strength bars (≥500 MPa) have great potential to accelerate bridge construction and enhance seismic performance. Four large‐scale pier column specimens using high‐strength bars by cast‐in‐place (CIP) and precast construction were experimentally studied. The distinctions of damage pattern between CIP and precast piers were characterized by plastic hinge and toed hinge, which expounded the smaller damage in precast piers. In contrast with CIP piers, the energy dissipation of precast pier was reduced by approximately 50–60% after pier yielding. An appropriate reinforcement ratio was essential for CIP piers to maintain enough displacement ductility and prevent premature fracture of energy dissipation bars. In terms of displacement components, the plastic term of precast pier was much smaller than that of CIP pier, and the gap opening‐induced displacement predominates after pier yielding. The toed hinge was elaborated to disclose the displacement mechanism in precast piers. The experimental findings in this paper can provide additional input for seismic design of precast piers with high‐strength bars.