SKSergey N. Kotov

Sergey N. Kotov

*This is an algorithmically generated author record based on publicly available information.

Sergey N. Kotov has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Factors that Determined a Positive Response to Resynchronization Therapy in Patients With Chronic Heart Failure and Cardiac Dyssynchrony. One Center Experience

    by A. S. Postol, N. M. Neminushchiy, G. N. Antipov, A. V. Ivanchenko, V. V. Lyashenko, D. A. Kalinin, S. N. Kotov, A. B. Vygovsky, Yu. A. Shneider

    Aim . To evaluate the efficacy of cardiac resynchronization therapy (CRT) in patients with chronic heart failure (CHF) associated with cardiac dyssynchrony and to identify the factors that influence the CRT efficacy. Material and methods . This retrospective study included 155 patients after implantation of CRT devices. The CRT devices with a built-in cardioverter-defibrillator (CRT-D) and without it (CRT-P) were implanted in 139 (89.7%) and 16 (10.3%) patients, respectively. The follow-up period was 52.37±35.94 months. Based on the study results, two groups of patients were formed depending on the presence of a clinical response to CRT, responders and non-responders. The factors that influenced the clinical response to CRT were studied. The effect of the baseline state of patients on the effect of therapy was assessed. The need for CRT optimization and a possibility of using electrocardiographic criteria for that purpose were studied. Modern devices and leads for CRT, their functional capabilities and their influence on the CRT efficacy were characterized. Statistical analysis was performed with an IBM SPSS Statistics 21.0 (Chicago, USA) package. Results . CRT implantation with the left ventricular lead placement according to the traditional technique, through the coronary sinus, was successful in 130 (87.9%) patients. Difficulties with the left ventricular lead placement were noted in 13 (8.3%) patients when other techniques were used. After 6 months, a hemodynamic and clinical response was observed in 112 (72.2%) patients, and no positive response in 43 (27.8%). The increase in left ventricular ejection fraction in the responder group was more than 21.8±3.7%, which was associated with an improvement of the 6-minute walk test results. Th clinical response was significantly influenced by the possibility of stimulation from the basal parts of the heart; the use of more modern devices for CRT and quadripolar left ventricular leads; timely CRT optimization; and persistent dyssynchrony in non-responders. During the follow-up period, 34 (21.9%) patients died. The death rate in the non-responder group was significantly higher than in the responder group, 18 (41.3%) vs. 16 (14.3%), p=0.001. The main cause of death in the group of non-responders was CHF. Heart transplantation was performed in 3 (1.9%) patients. Conclusion . CRT increases the life span and improves the quality of life in patients with CHF and cardiac dyssynchrony. There was a group of patients with no benefit from CRT in this study. Modern devices allow increasing the number of patients who benefit from CRT. Periodic optimization of CRT is necessary. When optimizing CRT, it is possible to use electrocardiographic criteria of effectiveness: duration of the QRS complex and changes in the position of the electrical axis of the heart.


  • Open Access

    Dysfunction of CRT-D in acute myocardial infarction: is there a place for programing?

    by A. S. Postol, G. N. Antipov, A. V. Ivanchenko, V. V. Lyashenko, D. A. Kalinin, S. N. Kotov, A. B. Vygovsky, Yu. A. Shnejder

    The article describes a clinical case of a patient with a previously implanted cardiac resynchronization therapy with defibrillator function (CRT-D). For a long time, the patient was observed in the implanting clinic and the data was also transmitted via remote monitoring. The developing acute myocardial infarction in the right coronary artery caused a change in the parameter of the amplitude of the spontaneous R-wave in the patient. Subsequent ventricular fibrillation (VF) due to stent thrombosis was undetected by the defibrillator and resulted in no detection and cessation of VF, despite the implanted CRT-D. Changing the programming parameters did not affect the possibility of detecting a recurrent VF. The VF that occurred twice was stopped by the first discharge of the external device. In view of the remaining low hyposensing, a decision was made to reimplant the detecting part of the right ventricular electrode, after which defibrillation test proved to be effective for termination induced VF. We believe that at critically low parameters of spontaneous R-wave hyposensing, for the device to detect low-amplitude ventricular arrhythmias, programming the parameters does not solve the problem of hyposensing. Current myocardial infarction as the cause of hyposensing may require active surgical tactics replacement of the pacing and sensing electrode, in cases where the device connector allows this.

  • Open Access

    Analysis of the endocardial stage of treatment of tachyarhythmias after open interventions for atrial fibrillation. Experience of one center

    by Anzhelika S. Postol, Georgy N. Antipov, Andrey V. Ivanchenko, Vitaliy V. Lyashenko, Dmitry A. Kalinin, Sergey N. Kotov, Alexander B. Vygovsky, Yuriy A. Shneider, Ляшенко Виталий Валерьевич, Шнейдер Юрий Александрович

    AIM: To study EFI parameters and features of recurrent atrial tachyarrhythmias in patients who underwent surgical correction of AF. MATERIALS AND METHODS: from January 2013 to December 2021, 447 combined interventions were performed to eliminate AF using the labyrinth-3 and left atrial labyrinth techniques with correction of CHD (congenital heart disease) and/or coronary artery disease. Rhythm disturbances were detected in 57 (12.7%) patients at various follow-up periods. Endovascular interventions were performed in 39 patients. The average follow-up period after the endocardial stage was 34.37 (standard deviation 24.32) months. The median age of patients was 64 (58–67) years, 21 (54%) were men. The patients were divided into 2 groups: group 1 — after the classic biatrial (BA) labyrinth-3 — 23 (59%) patients, group 2 — after the left-atrial variant (LA) labyrinth-3 — 16 (41%) patients. At the endocardial stage, electrophysiological studies (EFI) were performed to clarify the mechanism of arrhythmia, and ablation eliminated tachyarrhythmia. EFI protocol: revision of the pulmonary veins, determination of the isolation of the posterior wall of the LA assessment of atrial arrhythmia, elimination of arrhythmia, control induction of arrhythmia after ablation. After repeated intervention, patients were observed in the operating clinic every 3 months. RESULTS: After the endocardial stage, a regular rhythm was determined in 19 (82.6%) patients of the BA group, 13 (92.9%) patients of the LA group (p = 0.914). Relapses in the form of AF were noted in 5 patients (4 — group 1 and 1 — group 2) group (p = 0.306) All relapses of tachyarrhythmia with an irregular cycle (AF) were detected in patients with AF before the endovascular stage In both groups, there were cases of restoration of conduction in the pulmonary veins — 10 (43.5%) patients after BA ablation and 1 (5.3%) patient after LA ablation. There are no recurrences of atrial arrhythmia after ablation of atrial flutter (arrhythmia with a stable cycle). CONCLUSION: The endocardial stage is highly effective and demonstrates subsequent freedom from atrial arrhythmia in patients who have tachycardia with a regular cycle after both methods of surgical ablation of AF. Recurrent tachyarrhythmia in the form of AF (irregular cycle) is associated with a low probability of maintaining a regular atrial rhythm after a repeated endocardial procedure, due to the presence of structural and electrophysiological changes in the atrial myocardium.

  • Open Access

    Evaluation of atrial contractility and remodeling after the Maze-3 procedure with combined heart interventions

    by G. N. Antipov, A. S. Postol, S. N. Kotov, M. O. Makarova, Yu. A. Schneider, Ю. А. Шнейдер

    Highlights. The most important goal of atrial fibrillation surgical treatment is to eliminate the arrhythmia in order to restore atrial contractility and improve their transport function. Our study showed positive dynamics of atrial contractility and remodeling after the maze-3 procedure against the background of a regular heart rhythm restoration. The study of sinus rhythm predictors maintenance and recovery of atrial transport function will help to make patient selection more personified.Aim. Evaluation of atrial contractility and remodeling after the maze-3 procedure with combined interventions on the heart.Methods. The analysis of 217 combined surgical interventions was carried out, where a maze-3 was used to treat atrial fibrillation (AF). The operations were performed in our center from 2012 to 2016. Key points of the study: rhythm after surgery and echocardiographic control in the long-term follow-up in order to determine the dynamics of atrial contractility and volumes. The average follow-up period was 47 (1–100) months. 40 (18.4%) patients had paroxysmal, 38 (17.5%) persistent, 139 (64.1%) long-term persistent AF. The mean AF duration before surgery was 27.4 months (1–200 months). The indications for the maze-3 procedure were: ineffectiveness of antiarrhythmic therapy, the need to perform combined cardiac procedures. We used standard statistical research methods with one – and multivariate logistic regression.Results. In the long-term follow-up, sinus rhythm (SR) persists in 79% of patients. In the long-term follow-up, in this group of patients, the left atrial contractility was restored from 76% to 91%, while the biatrial contractility increased from 82 to 96%. Shorter AF duration before surgery was a positive predictor of SR recovery and atrial contractility (p = 0.005), while pulmonary artery pressure and patient age negatively affected these indicators (p = 0.041 and p = 0.038, respectively). The presence of SR early after surgery was not a significant predictor of AF freedom. At the same time, according to the long-term observations, patients maintaining a regular atrial heart rate had positive indicators of atrial systolic function restoration and a positive dynamics of a decrease in atrial volumes.Conclusion. SR and restoration of left atrial contractility are two interrelated goals of the maze procedure. The negative factors associated with the failure of surgical treatment of AF are increased pressure in the pulmonary artery, long-term AF before surgery, and the age of patients.

  • Open Access

    Atrial remodelling comparison after maze-3 and cryo-maze procedures in combined cardiac interventions: a retrospective study

    by G. N. Antipov, A. S. Postol, S. N. Kotov, M. O. Makarova, Yu. A. Shneider, Ю. А. Шнейдер

    Background. The maze procedure aims to eliminate atrial fibrillation (AF), restore sinus rhythm (SR) and atrial contractility. However, conflicting evidence exists regarding the extent of atrial remodelling in various techniques, which directed the focus of our study.Objectives. An atrial remodelling comparison after a cut-and-sew maze-3 surgery and its biatrial cryo-maze modification using 2D echocardiography.Methods. The study is a retrospective uncontrolled interrupted two-cohort time-series trial, with patients selected by pseudorandomisation according to a normal sinus rhythm-maintaining AF surgery method. A total of 217 maze-3 and 113 cryo-maze combined cardiac interventions have been performed within 2012–2021. The interventions included valve repair, coronary artery bypass grafting and their combination. Due to differences in long-term follow-up, the cohorts were pseudorandomised to select by 50 restored vs. maintained sinus rhythm patients using a nearest-neighbour classifier coupled with logistic regression. Mean follow-up period was 6 (1–17) months. The patients had paroxysmal, persistent and longstanding persistent AF. Echocardiography values prior to and long-term post-surgery were further analysed to determine the atrial remodelling dynamics. Results. A statistically significant atrial volume reduction is evident in a long-term within-cohort comparison. Meanwhile, a statistically more pronounced remodelling is observed between cohorts after maze-3 procedure. The cohort 1 vs. 2 estimates are: mean left atrial volume 120/125 mL3 (p = 0.011), left atrial size in apical view 52/53 mm (p = 0.023), right atrial size in apical view 58/62 mm (p = 0.004), right atrial size in parasternal short axis view 43/45 mm (p = 0.004), right atrial area in apical 4-chamber view 25/28 cm2 (p = 0.007). Maintained atrial pacing patients had positive systolic atrial function recovery rates (E/A ratio increased to average 1.5) in the long-term in both comparison cohorts.Conclusion. Remodelling is biatrial after all the maze procedures compared. A more pronounced atrial volume reduction occurs after maze-3 surgery. The presence of sinus rhythm is facilitated by cardiac conduction leading to mechanical and electrical remodelling of the atria.


  • Analysis of the causes and frequency of permanent pacemaker implantation after different variants of surgical treatment of atrial fibrillation with combined cardiac surgery

    by Kaliningrad Federal Center For High Medical Technologies (Kaliningrad), G.N. Antipov, A.S. Postol, S.N. Kotov, M.O. Makarova, Yu.A. Schneider

    Анализ причин и частоты имплантации кардиостимуляторов после различных вариантов хирургического лечения фибрилляции предсердий при сочетанных


  • Open Access

    A 6-year experience of the Ross procedure in children with congenital aortic valve disease

    by D. S. Akatov, V. A. Belov, D. E. Khomich, O. N. Bukhareva, A. A. Makarov, S. N. Kotov, Yu. A. Schneider

    Background: The choice of an optimal method for correction of aortic valve stenosis or insufficiency remains the matter of debate. Some clinicians prefer transluminal balloon angioplasty, some would perform an open type commissurotomy, or aortic valve replacement, or to valve leaflets repair with various materials, while others opt for the Ross procedure. Each of these techniques has its advantages and disadvantages both in the early postoperative period and in the long-term.Aim: To assess the results of the Ross procedure, its complications, survival, and probability of reoperations in the long-term.Materials and methods: We retrospectively analyzed the results of 32 Ross procedures performed from the end of 2012 to the beginning of 2019 in children aged from 3 days to 18 years. Eight children were below 1 year of age, including one newborn. A pulmonary autograft was placed into the aortic position in all children. In 31 children, a homograft was placed into the pulmonary artery. In one patient, an aortic autograft was implanted instead of the pulmonary artery valve. The mean patient age was 6.8 years, mean bodyweight 27.7 kg (range, 3.9–74.6 kg).Results: Two patients died in the early postoperative period (mortality 6.25%). We examined 26 patients at the follow-up, with its mean duration of 2.5 years. There were no indications for replacement of the homograft during the follow-up. One patient, in whom we had implanted an aortic autograft into the pulmonary position, required its replacement after 4.5 years. We have no data on death rates in the long-term.Conclusion: The Ross procedure provides satisfactory results in the early and intermediate postoperative period. Continuous follow-up is needed to determine the time points and the proportion of repeated interventions with a pulmonary homograft and aortic valve.

  • Open Access

    Reoperations after the correction of partial abnormal venous return: a clinical case series

    by D. S. Akatov, V. A. Belov, O. N. Bukhareva, D. E. Khomich, A. A. Makarov, S. N. Kotov, Yu. A. Schneider

    Rationale: The surgical procedure for partial abnormal pulmonary venous return (PAPV) implies the formation of a tunnel between the orifices of the right pulmonary veins and the left atrial cavity with the interatrial septum repair. To avoid any obstruction of the tunnel, a direct anastomosis between the superior vena cava (SVC) and the right atrial appendage is placed in a number of cases. However, the reparative procedure is potentially associated with such complications as SVC stenosis and/or pulmonary vein stenosis. Aim: To present our experience of reoperations for stenosis of systemic and pulmonary veins after primary PAPV repair. Materials and methods: From 2014 to 2018, seven patients (boys, 4) with SVC stenosis and/or with stenosis of the right pulmonary veins have been admitted to the FCHMT (Kaliningrad). Their mean bodyweight was 29.1 kg (± 12.5 kg), mean age 9.3 years (± 3.6 years). Three patients had an isolated SVC stenosis. In two patients, there was a combination of SVC stenosis and pulmonary vein obstruction (from stenosis to complete occlusion); in one patient the right pulmonary vein stenosis had been caused by thrombosis. SVC stenosis with subaortal obstruction after the repair of double-outlet right ventricle was diagnosed in one case. In six patients, various procedures for correction of SVC and/or pulmonary vein stenosis were performed. Only in one case the obstruction of systemic veins, confirmed by cardiac catheterization, turned out to be non-significant, making a reoperation unnecessary. Results: There were no deaths in this patient group. Endovascular procedures were performed in two patients. In one case, there was an unsuccessful attempt of transluminal balloon angioplasty for SVC stenosis, with subsequent Warden procedure. In another case, a 16-year old patient with SVC stenosis and high pulmonary hypertension was admitted after two previous surgeries had failed. We used a homograft as SVC prosthesis; however, after one year, a re-stenosis was identified. In this case, a SVC stent placement was successful. Due to sick sinus syndrome at one year after the Warden procedure and the repair of pulmonary veins by a homograft, an implantation of electric cardiac pacemaker was necessary in one patient. Conclusion: The curative repair of partial abnormal venous return is a well-established surgical technique with satisfactory shortand long-term results. A potential complication of the procedure is an obstruction of systemic and pulmonary veins. To prevent such complications during primary defect repair, as well as with reoperations for vein stenosis, the Warden procedure seems effective and highly reproducible technique associated with lower surgical risks.