Simon J. Wilson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Simon J. Wilson has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- James Cs Spratt
City St George's University of London London UK
4 shared publications - Claudia Cosgrove
City St George's University of London London UK
3 shared publications David E. Newby
British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (M.N.M., J.R., S.J.W., D.E.N.).
3 shared publicationsColm G Hanratty
Department of Cardiology Mater Private Hospital Dublin UK
2 shared publicationsJames C. Spratt
St Georges' Hospitals NHS Foundation trust London UK
2 shared publicationsJennifer Raftis
British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, United Kingdom (M.N.M., J.R., S.J.W., D.E.N.).
2 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
Intravascular Lithotripsy in Left Main Stem Percutaneous Coronary Intervention
Background: IVL is increasingly used for coronary calcium modification; however, prospective data for its use in LMS lesions are lacking. Aims: To evaluate the feasibility, safety, and mechanical efficacy of intravascular lithotripsy (IVL) for calcium modification in calcified distal left main stem (LMS) percutaneous coronary intervention. Methods: In this prospective, multicentre, open‐label study across five United Kingdom centers (NCT04319666), 50 patients with obstructive distal LMS disease and IVUS‐confirmed circumferential calcification (maximum calcium arc ≥ 270° in at least one segment) underwent IVL‐assisted PCI. IVUS was mandated at pre‐treatment, post‐IVL, and post‐stent timepoints with independent core laboratory analysis. Co‐primary endpoints were IVUS‐assessed minimum stent area (MSA) and 30‐day major adverse cardiac events (MACE). Results: Fifty patients underwent IVUS‐guided LMS PCI with IVL for calcium modification. Device crossing was successful in all 50 cases. Mean LMS MSA was 13.36 ± 3.20 mm 2 (95% CI 12.44–14.28 mm 2 ); 84% of patients (41/49) achieved an LMS MSA exceeding 11 mm 2 . Significant luminal gain was observed across all territories (LMS 7.19 ± 3.52 mm 2 , p < 0.001). IVUS‐visible calcium fracture was not associated with stent expansion. There were no periprocedural deaths or myocardial infarctions and no MACE at 30 days. At 12 months, MACE occurred in 4 patients (8.0%) with no stent thrombosis. Conclusions: IVL is safe and mechanically efficacious for calcium modification in severely calcified distal LMS disease, achieving stent expansion exceeding prognostically validated thresholds with favorable clinical outcomes at 12 months. Clinical trial registration: clinicaltrials.gov NCT04319666.
- 7 October 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
Open AccessIntravascular Lithotripsy in Left Main Stem Percutaneous Coronary Intervention
Background: IVL is increasingly used for coronary calcium modification; however, prospective data for its use in LMS lesions are lacking. Aims: To evaluate the feasibility, safety, and mechanical efficacy of intravascular lithotripsy (IVL) for calcium modification in calcified distal left main stem (LMS) percutaneous coronary intervention. Methods: In this prospective, multicentre, open‐label study across five United Kingdom centers (NCT04319666), 50 patients with obstructive distal LMS disease and IVUS‐confirmed circumferential calcification (maximum calcium arc ≥ 270° in at least one segment) underwent IVL‐assisted PCI. IVUS was mandated at pre‐treatment, post‐IVL, and post‐stent timepoints with independent core laboratory analysis. Co‐primary endpoints were IVUS‐assessed minimum stent area (MSA) and 30‐day major adverse cardiac events (MACE). Results: Fifty patients underwent IVUS‐guided LMS PCI with IVL for calcium modification. Device crossing was successful in all 50 cases. Mean LMS MSA was 13.36 ± 3.20 mm 2 (95% CI 12.44–14.28 mm 2 ); 84% of patients (41/49) achieved an LMS MSA exceeding 11 mm 2 . Significant luminal gain was observed across all territories (LMS 7.19 ± 3.52 mm 2 , p < 0.001). IVUS‐visible calcium fracture was not associated with stent expansion. There were no periprocedural deaths or myocardial infarctions and no MACE at 30 days. At 12 months, MACE occurred in 4 patients (8.0%) with no stent thrombosis. Conclusions: IVL is safe and mechanically efficacious for calcium modification in severely calcified distal LMS disease, achieving stent expansion exceeding prognostically validated thresholds with favorable clinical outcomes at 12 months. Clinical trial registration: clinicaltrials.gov NCT04319666.
- 19 November 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 99 (2) , 234-244
Clinical outcomes of percutaneous coronary intervention for chronic total occlusion by treated segment length
Background: Long lesions are known to have worse outcomes following percutaneous coronary intervention (PCI), but there are limited data assessing the association between lesion length and clinical outcomes in PCI procedures undertaken in chronic total occlusions (CTO).Methods and results: We formed a longitudinal cohort (2006–2018, n = 27,205) of stable angina patients who underwent PCI to CTO in the British Cardiovascular Intervention Society (BCIS) database. Clinical, demographical, procedural, and outcome data were analyzed in three groups by treated segment length, < 30 mm (n = 11,782), 30–59 mm (n = 10,415), ≥ 60 mm (n = 5008). Prevalence of previous myocardial infarction and PCI were higher in patients in 30–59 mm group or ≥ 60 mm group compared with < 30 mm group. Following multivariable analysis, no significant difference was observed in in‐patient death (OR = 30–59 mm group = 1.10, CI:0.55–2.19, p = 0.78) (OR ≥ 60 mm group = 0.82, CI: 0.33–2.05, p = 0.67), and 1‐year death (OR = 30–59 mm group = 1.06, CI: 0.81–1.37, p = 0.69) (OR ≥ 60 mm group =1.01, CI: 0.70–1.43, p = 0.99) (< 30 mm group = reference) but in‐patient MACE was higher in > = 60 mm group (OR: 1.52, CI: 1.15–2.01, p = 0.06) but similar in 30–59 mm group (OR: 1.16, CI: 0.91–1.48, p = 0.22) compared with < 30 mm group. The adjusted rates of procedural complications were higher in ≥ 60 mm group (OR: 1.61, CI: 1.40–1.85, p < 0.001) but were similar in 30–59 mm group (OR: 1.06, CI: 0.94–1.20, p < 0.31) compared with < 30 mm group. For every 10 mm increase, there was an increased adjusted risk of in‐patient procedural complications and coronary perforation but not in‐patient MACE or death.Conclusion: Patients with very long CTO lesions have higher risk of procedural complications and in‐patient MACE but similar risk of short or long‐term mortality compared with short CTO lesions.
- 19 November 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 99 (2) , 234-244
Clinical outcomes of percutaneous coronary intervention for chronic total occlusion by treated segment length
Background: Long lesions are known to have worse outcomes following percutaneous coronary intervention (PCI), but there are limited data assessing the association between lesion length and clinical outcomes in PCI procedures undertaken in chronic total occlusions (CTO).Methods and results: We formed a longitudinal cohort (2006–2018, n = 27,205) of stable angina patients who underwent PCI to CTO in the British Cardiovascular Intervention Society (BCIS) database. Clinical, demographical, procedural, and outcome data were analyzed in three groups by treated segment length, < 30 mm (n = 11,782), 30–59 mm (n = 10,415), ≥ 60 mm (n = 5008). Prevalence of previous myocardial infarction and PCI were higher in patients in 30–59 mm group or ≥ 60 mm group compared with < 30 mm group. Following multivariable analysis, no significant difference was observed in in‐patient death (OR = 30–59 mm group = 1.10, CI:0.55–2.19, p = 0.78) (OR ≥ 60 mm group = 0.82, CI: 0.33–2.05, p = 0.67), and 1‐year death (OR = 30–59 mm group = 1.06, CI: 0.81–1.37, p = 0.69) (OR ≥ 60 mm group =1.01, CI: 0.70–1.43, p = 0.99) (< 30 mm group = reference) but in‐patient MACE was higher in > = 60 mm group (OR: 1.52, CI: 1.15–2.01, p = 0.06) but similar in 30–59 mm group (OR: 1.16, CI: 0.91–1.48, p = 0.22) compared with < 30 mm group. The adjusted rates of procedural complications were higher in ≥ 60 mm group (OR: 1.61, CI: 1.40–1.85, p < 0.001) but were similar in 30–59 mm group (OR: 1.06, CI: 0.94–1.20, p < 0.31) compared with < 30 mm group. For every 10 mm increase, there was an increased adjusted risk of in‐patient procedural complications and coronary perforation but not in‐patient MACE or death.Conclusion: Patients with very long CTO lesions have higher risk of procedural complications and in‐patient MACE but similar risk of short or long‐term mortality compared with short CTO lesions.
- Open Access
- 29 May 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 99 (2) , 322-328
Intravascular lithotripsy for treatment of calcific coronary lesions in ST elevation myocardial infarction
Aims: To describe the utility and safety of intravascular lithotripsy (IVL) in the setting of primary percutaneous coronary intervention (PCI) for ST elevation myocardial infarction (STEMI).Methods and results: We performed a retrospective analysis, across six UK sites of all patients in whom IVL was used for coronary calcium modification of the culprit lesion during primary PCI for STEMI. The 72 patients were included. IVL was used in de‐novo culprit lesions in 57 (79%) of cases and culprit in‐stent restenoses in 11 (15%) of cases. In four cases (6%) it was used in a newly deployed stent when this was under‐expanded due to inadequate calcium modification. Of the 30 cases in which intracoronary imaging was available for stent analysis, the average stent expansion was 104%. Intra‐procedural stent thrombosis occurred in one case (1%), and no‐reflow in three cases (4%). The 30 day MACE rates were 18%.Conclusion: IVL appears to be feasible and safe for use in the treatment of calcific coronary artery disease in the setting of STEMI.
- 29 May 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 99 (2) , 322-328
Open AccessIntravascular lithotripsy for treatment of calcific coronary lesions in ST elevation myocardial infarction
Aims: To describe the utility and safety of intravascular lithotripsy (IVL) in the setting of primary percutaneous coronary intervention (PCI) for ST elevation myocardial infarction (STEMI).Methods and results: We performed a retrospective analysis, across six UK sites of all patients in whom IVL was used for coronary calcium modification of the culprit lesion during primary PCI for STEMI. The 72 patients were included. IVL was used in de‐novo culprit lesions in 57 (79%) of cases and culprit in‐stent restenoses in 11 (15%) of cases. In four cases (6%) it was used in a newly deployed stent when this was under‐expanded due to inadequate calcium modification. Of the 30 cases in which intracoronary imaging was available for stent analysis, the average stent expansion was 104%. Intra‐procedural stent thrombosis occurred in one case (1%), and no‐reflow in three cases (4%). The 30 day MACE rates were 18%.Conclusion: IVL appears to be feasible and safe for use in the treatment of calcific coronary artery disease in the setting of STEMI.
- Open Access
- 1 November 2020
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 40 (11) , 2678-2685
Antithrombotic Effects of Combined PAR (Protease-Activated Receptor)-4 Antagonism and Factor Xa Inhibition
Objective: PAR (protease-activated receptor)-4 antagonism has antiplatelet effects under conditions of high shear stress. We aimed to establish whether PAR4 antagonism had additive antithrombotic activity in the presence of factor Xa inhibition in an ex vivo model of acute arterial injury. Approach and Results: Fifteen healthy volunteers (29±6 years, 7 women) completed a phase zero double-blind randomized controlled crossover trial. Ex vivo platelet activation, platelet aggregation, and thrombus formation were measured following blood perfusion of low shear and high shear stress chambers. Upstream of the chambers, extracorporeal blood was admixed with (1) vehicle, (2) low-dose apixaban (20 ng/mL), (3) high-dose apixaban (80 ng/mL), (4) BMS-986141 (400 ng/mL), (5) BMS-968141 and low-dose apixaban, or (6) BMS-968141 and high-dose apixaban in 6 sequential studies performed in random order. Compared with vehicle, BMS-986141 demonstrated selective inhibition of PAR4-AP (agonist peptide)–stimulated platelet aggregation, platelet-monocyte aggregates, and P-selectin expression ( P ≤0.01 for all). Total thrombus area was reduced under both low shear and high shear stress conditions for all drug infusions ( P P ≤0.027). Conclusions: In the presence of factor Xa inhibition, PAR4 antagonism with BMS-986141 further reduces thrombus formation, especially under conditions of high shear stress. This suggests the potential for additive efficacy of combination PAR4 antagonism and factor Xa inhibition in the prevention of atherothrombotic events.
- 1 November 2020
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 40 (11) , 2678-2685
Open AccessAntithrombotic Effects of Combined PAR (Protease-Activated Receptor)-4 Antagonism and Factor Xa Inhibition
Objective: PAR (protease-activated receptor)-4 antagonism has antiplatelet effects under conditions of high shear stress. We aimed to establish whether PAR4 antagonism had additive antithrombotic activity in the presence of factor Xa inhibition in an ex vivo model of acute arterial injury. Approach and Results: Fifteen healthy volunteers (29±6 years, 7 women) completed a phase zero double-blind randomized controlled crossover trial. Ex vivo platelet activation, platelet aggregation, and thrombus formation were measured following blood perfusion of low shear and high shear stress chambers. Upstream of the chambers, extracorporeal blood was admixed with (1) vehicle, (2) low-dose apixaban (20 ng/mL), (3) high-dose apixaban (80 ng/mL), (4) BMS-986141 (400 ng/mL), (5) BMS-968141 and low-dose apixaban, or (6) BMS-968141 and high-dose apixaban in 6 sequential studies performed in random order. Compared with vehicle, BMS-986141 demonstrated selective inhibition of PAR4-AP (agonist peptide)–stimulated platelet aggregation, platelet-monocyte aggregates, and P-selectin expression ( P ≤0.01 for all). Total thrombus area was reduced under both low shear and high shear stress conditions for all drug infusions ( P P ≤0.027). Conclusions: In the presence of factor Xa inhibition, PAR4 antagonism with BMS-986141 further reduces thrombus formation, especially under conditions of high shear stress. This suggests the potential for additive efficacy of combination PAR4 antagonism and factor Xa inhibition in the prevention of atherothrombotic events.
- 1 July 2020
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 13 (7) , e009438
Effect of the COVID-19 Pandemic on ST-Segment–Elevation Myocardial Infarction Presentations and In-Hospital Outcomes
- 1 July 2020
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 13 (7) , e009438
Effect of the COVID-19 Pandemic on ST-Segment–Elevation Myocardial Infarction Presentations and In-Hospital Outcomes
- 8 January 2020
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 97 (1) , 22-29
Management of stent underexpansion using intravascular lithotripsy—Defining the utility of a novel device
Objectives: This study aimed to present a case series of patient treated for stent underexpansion resistant to conventional treatment with intravascular lithotripsy (IVL).Background: Stent underexpansion is a powerful predictor of long‐term stent patency and correlates with unfavorable clinical outcomes. This case series demonstrates the utility of IVL in managing stent underexpansion resistant to conventional treatment.Methods: We describe a case series of patients with stent underexpansion due to calcific coronary artery disease treated with IVL. Stent underexpansion was identified as an inability to adequately expand stents with conventional treatment. Only cases that failed to achieve adequate expansion with high‐pressure noncompliant balloon inflation were included.Results: Thirteen patients from six institutions have been included in this case series. The average age was 70.25 years with 76.9% of male patients. The average pre‐IVL minimal stent area (MSA) was 2.71 mm2, which improved to 6.44 mm2 post‐IVL treatment, representing an average MSA gain of 238%. There were no procedural, peri‐procedural, or 30‐day major adverse cardiac and cerebrovascular event.Conclusion: This case series demonstrates that IVL is a feasible, safe alternative for the management of stent underexpansion due to calcific coronary disease.
- 8 January 2020
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 97 (1) , 22-29
Management of stent underexpansion using intravascular lithotripsy—Defining the utility of a novel device
Objectives: This study aimed to present a case series of patient treated for stent underexpansion resistant to conventional treatment with intravascular lithotripsy (IVL).Background: Stent underexpansion is a powerful predictor of long‐term stent patency and correlates with unfavorable clinical outcomes. This case series demonstrates the utility of IVL in managing stent underexpansion resistant to conventional treatment.Methods: We describe a case series of patients with stent underexpansion due to calcific coronary artery disease treated with IVL. Stent underexpansion was identified as an inability to adequately expand stents with conventional treatment. Only cases that failed to achieve adequate expansion with high‐pressure noncompliant balloon inflation were included.Results: Thirteen patients from six institutions have been included in this case series. The average age was 70.25 years with 76.9% of male patients. The average pre‐IVL minimal stent area (MSA) was 2.71 mm2, which improved to 6.44 mm2 post‐IVL treatment, representing an average MSA gain of 238%. There were no procedural, peri‐procedural, or 30‐day major adverse cardiac and cerebrovascular event.Conclusion: This case series demonstrates that IVL is a feasible, safe alternative for the management of stent underexpansion due to calcific coronary disease.
- 1 December 2019
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 20 (12) , 1048-1052
Saphenous Vein Graft Sacrifice Following Native Vessel PCI is Safe and Associated with Favourable Longer-Term Outcomes
- 1 December 2019
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 20 (12) , 1048-1052
Saphenous Vein Graft Sacrifice Following Native Vessel PCI is Safe and Associated with Favourable Longer-Term Outcomes
- Open Access
- 26 October 2018
- Published by Oxford University Press (OUP) in Cardiovascular Research
- Vol. 115 (3) , 669-677
Exosite 1 thrombin inhibition with JNJ-64179375 inhibits thrombus formation in a human translational model of thrombosis
Aims: JNJ-64179375 (hereafter JNJ-9375) is a first-in-class, highly specific, large molecule, exosite 1 thrombin inhibitor. In preclinical studies, JNJ-9375 demonstrated robust antithrombotic protection with a wider therapeutic index when compared to apixaban. The purpose of the present study was to examine for the first time the antiplatelet, anticoagulant and antithrombotic effects of JNJ-9375 in a translational model of ex vivo human thrombosis.Methods and results: Fifteen healthy volunteers participated in a double-blind randomized crossover study of JNJ-9375 (2.5, 25, and 250 μg/mL), bivalirudin (6 μg/mL; positive control), and matched placebo. Coagulation, platelet activation, and thrombus formation were determined using coagulation assays, flow cytometry, and an ex vivo perfusion chamber, respectively.JNJ-9375 caused concentration-dependent prolongation of all measures of blood coagulation (prothrombin time, activated partial thromboplastin time, and thrombin time; P < 0.001 for all) and agonist selective inhibition of thrombin (0.1 U/mL) stimulated platelet p-selectin expression (P < 0.001) and platelet-monocyte aggregates (P = 0.002). Compared to placebo, JNJ-9375 (250 μg/mL) reduced mean total thrombus area by 41.1% (95% confidence intervals 22.3 to 55.3%; P < 0.001) at low shear and 32.3% (4.9 to 51.8%; P = 0.025) at high shear. Under both shear conditions, there was a dose-dependent decrease in fibrin-rich thrombus (P < 0.001 for both) but not platelet-rich thrombus (P = ns for both).Conclusion: Exosite 1 inhibition with JNJ-9375 caused prolongation of blood coagulation, selective inhibition of thrombin-mediated platelet activation, and reductions in ex vivo thrombosis driven by a decrease in fibrin-rich thrombus formation. JNJ-9375 represents a novel class of anticoagulant with potential therapeutic applications.
- 26 October 2018
- Published by Oxford University Press (OUP) in Cardiovascular Research
- Vol. 115 (3) , 669-677
Open AccessExosite 1 thrombin inhibition with JNJ-64179375 inhibits thrombus formation in a human translational model of thrombosis
Aims: JNJ-64179375 (hereafter JNJ-9375) is a first-in-class, highly specific, large molecule, exosite 1 thrombin inhibitor. In preclinical studies, JNJ-9375 demonstrated robust antithrombotic protection with a wider therapeutic index when compared to apixaban. The purpose of the present study was to examine for the first time the antiplatelet, anticoagulant and antithrombotic effects of JNJ-9375 in a translational model of ex vivo human thrombosis.Methods and results: Fifteen healthy volunteers participated in a double-blind randomized crossover study of JNJ-9375 (2.5, 25, and 250 μg/mL), bivalirudin (6 μg/mL; positive control), and matched placebo. Coagulation, platelet activation, and thrombus formation were determined using coagulation assays, flow cytometry, and an ex vivo perfusion chamber, respectively.JNJ-9375 caused concentration-dependent prolongation of all measures of blood coagulation (prothrombin time, activated partial thromboplastin time, and thrombin time; P < 0.001 for all) and agonist selective inhibition of thrombin (0.1 U/mL) stimulated platelet p-selectin expression (P < 0.001) and platelet-monocyte aggregates (P = 0.002). Compared to placebo, JNJ-9375 (250 μg/mL) reduced mean total thrombus area by 41.1% (95% confidence intervals 22.3 to 55.3%; P < 0.001) at low shear and 32.3% (4.9 to 51.8%; P = 0.025) at high shear. Under both shear conditions, there was a dose-dependent decrease in fibrin-rich thrombus (P < 0.001 for both) but not platelet-rich thrombus (P = ns for both).Conclusion: Exosite 1 inhibition with JNJ-9375 caused prolongation of blood coagulation, selective inhibition of thrombin-mediated platelet activation, and reductions in ex vivo thrombosis driven by a decrease in fibrin-rich thrombus formation. JNJ-9375 represents a novel class of anticoagulant with potential therapeutic applications.
- 20 March 2018
- Published by SAGE Publications in Antioxidants & Redox Signaling
- Vol. 28 (9) , 819-836
Effects of Diesel Exhaust on Cardiovascular Function and Oxidative Stress
Significance: Air pollution is a major global health concern with particulate matter (PM) being especially associated with increases in cardiovascular morbidity and mortality. Diesel exhaust emissions are a particularly rich source of the smallest sizes of PM (“fine” and “ultrafine”) in urban environments, and it is these particles that are believed to be the most detrimental to cardiovascular health. Recent Advances: Controlled exposure studies to diesel exhaust in animals and man demonstrate alterations in blood pressure, heart rate, vascular tone, endothelial function, myocardial perfusion, thrombosis, atherogenesis, and plaque stability. Oxidative stress has emerged as a highly plausible pathobiological mechanism by which inhalation of diesel exhaust PM leads to multiple facets of cardiovascular dysfunction. Critical Issues: Diesel exhaust inhalation promotes oxidative stress in several biological compartments that can be directly associated with adverse cardiovascular effects. Future Directions: Further studies with more sensitive and specific in vivo human markers of oxidative stress are required to determine if targeting oxidative stress pathways involved in the actions of diesel exhaust PM could be of therapeutic value. Antioxid. Redox Signal. 00, 000–000.
- 20 March 2018
- Published by SAGE Publications in Antioxidants & Redox Signaling
- Vol. 28 (9) , 819-836
Effects of Diesel Exhaust on Cardiovascular Function and Oxidative Stress
Significance: Air pollution is a major global health concern with particulate matter (PM) being especially associated with increases in cardiovascular morbidity and mortality. Diesel exhaust emissions are a particularly rich source of the smallest sizes of PM (“fine” and “ultrafine”) in urban environments, and it is these particles that are believed to be the most detrimental to cardiovascular health. Recent Advances: Controlled exposure studies to diesel exhaust in animals and man demonstrate alterations in blood pressure, heart rate, vascular tone, endothelial function, myocardial perfusion, thrombosis, atherogenesis, and plaque stability. Oxidative stress has emerged as a highly plausible pathobiological mechanism by which inhalation of diesel exhaust PM leads to multiple facets of cardiovascular dysfunction. Critical Issues: Diesel exhaust inhalation promotes oxidative stress in several biological compartments that can be directly associated with adverse cardiovascular effects. Future Directions: Further studies with more sensitive and specific in vivo human markers of oxidative stress are required to determine if targeting oxidative stress pathways involved in the actions of diesel exhaust PM could be of therapeutic value. Antioxid. Redox Signal. 00, 000–000.
- Open Access
- 1 February 2018
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 38 (2) , 448-456
PAR4 (Protease-Activated Receptor 4) Antagonism With BMS-986120 Inhibits Human Ex Vivo Thrombus Formation
Objective—: BMS-986120 is a novel first-in-class oral PAR4 (protease-activated receptor 4) antagonist with potent and selective antiplatelet effects. We sought to determine for the first time, the effect of BMS-986120 on human ex vivo thrombus formation. Approach and Results—: Forty healthy volunteers completed a phase 1 parallel-group PROBE trial (Prospective Randomized Open-Label Blinded End Point). Ex vivo platelet activation, platelet aggregation, and thrombus formation were measured at 0, 2, and 24 hours after (1) oral BMS-986120 (60 mg) or (2) oral aspirin (600 mg) followed at 18 hours with oral aspirin (600 mg) and oral clopidogrel (600 mg). BMS-986120 demonstrated highly selective and reversible inhibition of PAR4 agonist peptide (100 μM)-stimulated P-selectin expression, platelet-monocyte aggregates, and platelet aggregation ( P 2 /mm) at high shear was reduced by 29.2% (95% confidence interval, 18.3%–38.7%; P P =0.002) at 24 hours. Reductions in thrombus formation were driven by a decrease in platelet-rich thrombus deposition: 34.8% (19.3%–47.3%; P P =0.016) at 24 hours. In contrast to aspirin alone, or in combination with clopidogrel, BMS-986120 had no effect on thrombus formation at low shear ( P =nonsignificant). BMS-986120 administration was not associated with an increase in coagulation times or serious adverse events. Conclusions—: BMS-986120 is a highly selective and reversible oral PAR4 antagonist that substantially reduces platelet-rich thrombus formation under conditions of high shear stress. Our results suggest PAR4 antagonism has major potential as a therapeutic antiplatelet strategy. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT02439190.
- 1 February 2018
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 38 (2) , 448-456
Open AccessPAR4 (Protease-Activated Receptor 4) Antagonism With BMS-986120 Inhibits Human Ex Vivo Thrombus Formation
Objective—: BMS-986120 is a novel first-in-class oral PAR4 (protease-activated receptor 4) antagonist with potent and selective antiplatelet effects. We sought to determine for the first time, the effect of BMS-986120 on human ex vivo thrombus formation. Approach and Results—: Forty healthy volunteers completed a phase 1 parallel-group PROBE trial (Prospective Randomized Open-Label Blinded End Point). Ex vivo platelet activation, platelet aggregation, and thrombus formation were measured at 0, 2, and 24 hours after (1) oral BMS-986120 (60 mg) or (2) oral aspirin (600 mg) followed at 18 hours with oral aspirin (600 mg) and oral clopidogrel (600 mg). BMS-986120 demonstrated highly selective and reversible inhibition of PAR4 agonist peptide (100 μM)-stimulated P-selectin expression, platelet-monocyte aggregates, and platelet aggregation ( P 2 /mm) at high shear was reduced by 29.2% (95% confidence interval, 18.3%–38.7%; P P =0.002) at 24 hours. Reductions in thrombus formation were driven by a decrease in platelet-rich thrombus deposition: 34.8% (19.3%–47.3%; P P =0.016) at 24 hours. In contrast to aspirin alone, or in combination with clopidogrel, BMS-986120 had no effect on thrombus formation at low shear ( P =nonsignificant). BMS-986120 administration was not associated with an increase in coagulation times or serious adverse events. Conclusions—: BMS-986120 is a highly selective and reversible oral PAR4 antagonist that substantially reduces platelet-rich thrombus formation under conditions of high shear stress. Our results suggest PAR4 antagonism has major potential as a therapeutic antiplatelet strategy. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT02439190.