Gavin Robertson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gavin Robertson has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- Enrico Pellegrini
Optos (Nikon)
8 shared publications - Emanuele Trucco
VAMPIRE project, Computing School of Science and Engineering, University of Dundee, Dundee, UK
7 shared publications - Jano van Hemert
Optos plc
7 shared publications - Tom MacGillivray
Institute for Neuroscience and Cardiovascular Research, The University of Edinburgh, United Kingdom
5 shared publications Alan Fleming
Optos Plc, Dunfermline, United Kingdom
3 shared publicationsBaljean Dhillon
The VAMPIRE Project, Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, UK
3 shared publications
Latest Publications
- Open Access
- 12 October 2026
- Published by Elsevier in Ophthalmology Science
- Vol. 6 (12)
Cell Density Mapped Retinal Nonperfusion and Low-Luminance Visual Acuity in Diabetic Retinopathy
- 12 October 2026
- Published by Elsevier in Ophthalmology Science
- Vol. 6 (12)
Open AccessCell Density Mapped Retinal Nonperfusion and Low-Luminance Visual Acuity in Diabetic Retinopathy
- 1 June 2021
- Published by Elsevier in Ophthalmology Retina
- Vol. 5 (6) , 571-579
Retinal Vascular Caliber Association with Nonperfusion and Diabetic Retinopathy Severity Depends on Vascular Caliber Measurement Location
- 1 June 2021
- Published by Elsevier in Ophthalmology Retina
- Vol. 5 (6) , 571-579
Retinal Vascular Caliber Association with Nonperfusion and Diabetic Retinopathy Severity Depends on Vascular Caliber Measurement Location
- 24 January 2020
- Published by Springer Nature
- p. 399-410
Optic Disc and Fovea Localisation in Ultra-widefield Scanning Laser Ophthalmoscope Images Captured in Multiple Modalities
- 24 January 2020
- Published by Springer Nature
- p. 399-410
Optic Disc and Fovea Localisation in Ultra-widefield Scanning Laser Ophthalmoscope Images Captured in Multiple Modalities
- Open Access
- 8 January 2020
- Published by BMJ in Open Heart
- Vol. 7 (1) , e001124
Association between hypertension and retinal vascular features in ultra-widefield fundus imaging
Objective Changes to the retinal vasculature are known to be associated with hypertension independently of traditional risk factors. We investigated whether measurements of retinal vascular calibre from ultra-widefield fundus imaging were associated with hypertensive status. Methods We retrospectively collected and semiautomatically measured ultra-widefield retinal fundus images from a subset of participants enrolled in an ongoing population study of ageing, categorised as normotensive or hypertensive according to thresholds on systolic/diastolic blood pressure (140/90 mm Hg) measured in a clinical setting. Vascular calibre in the peripheral retina was measured to calculate the nasal–annular arteriole:venule ratio (NA-AVR), a novel combined parameter. Results Left and right eyes were analysed from 440 participants (aged 50–59 years, mean age of 54.6±2.9 years, 247, 56.1% women), including 151 (34.3%) categorised as hypertensive. Arterioles were thinner and the NA-AVR was smaller in people with hypertension. The area under the receiver operating characteristic curve of NA-AVR for hypertensive status was 0.73 (95% CI 0.68 to 0.78) using measurements from left eyes, while for right eyes, it was 0.64 (95% CI 0.59 to 0.70), representing evidence of a statistically significant difference between the eyes (p=0.020). Conclusions Semiautomated measurements of NA-AVR in ultra-widefield fundus imaging were associated with hypertension. With further development, this may help screen people attending routine eye health check-ups for high blood pressure. These individuals may then follow a care pathway for suspected hypertension. Our results showed differences between left and right eyes, highlighting the importance of investigating both eyes of a patient.
- 8 January 2020
- Published by BMJ in Open Heart
- Vol. 7 (1) , e001124
Open AccessAssociation between hypertension and retinal vascular features in ultra-widefield fundus imaging
Objective Changes to the retinal vasculature are known to be associated with hypertension independently of traditional risk factors. We investigated whether measurements of retinal vascular calibre from ultra-widefield fundus imaging were associated with hypertensive status. Methods We retrospectively collected and semiautomatically measured ultra-widefield retinal fundus images from a subset of participants enrolled in an ongoing population study of ageing, categorised as normotensive or hypertensive according to thresholds on systolic/diastolic blood pressure (140/90 mm Hg) measured in a clinical setting. Vascular calibre in the peripheral retina was measured to calculate the nasal–annular arteriole:venule ratio (NA-AVR), a novel combined parameter. Results Left and right eyes were analysed from 440 participants (aged 50–59 years, mean age of 54.6±2.9 years, 247, 56.1% women), including 151 (34.3%) categorised as hypertensive. Arterioles were thinner and the NA-AVR was smaller in people with hypertension. The area under the receiver operating characteristic curve of NA-AVR for hypertensive status was 0.73 (95% CI 0.68 to 0.78) using measurements from left eyes, while for right eyes, it was 0.64 (95% CI 0.59 to 0.70), representing evidence of a statistically significant difference between the eyes (p=0.020). Conclusions Semiautomated measurements of NA-AVR in ultra-widefield fundus imaging were associated with hypertension. With further development, this may help screen people attending routine eye health check-ups for high blood pressure. These individuals may then follow a care pathway for suspected hypertension. Our results showed differences between left and right eyes, highlighting the importance of investigating both eyes of a patient.
- 1 January 2020
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 209, 99-106
Relationship Between Retinal Fractal Dimension and Nonperfusion in Diabetic Retinopathy on Ultrawide-Field Fluorescein Angiography
- 1 January 2020
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 209, 99-106
Relationship Between Retinal Fractal Dimension and Nonperfusion in Diabetic Retinopathy on Ultrawide-Field Fluorescein Angiography
- 1 September 2018
- Published by Wolters Kluwer Health in Hypertension
- Vol. 72 (Suppl_1)
Abstract P400: Screening for Hypertension Using Retinal Vascular Calibre in Ultra-Widefield Fundus Imaging
Fundus images from the left eyes of 440 subjects aged 50-59 years enrolled in the Northern Ireland Cohort of Longitudinal Ageing were analyzed. Subjects were categorized as normotensive or hypertensive, according to thresholds on systolic/diastolic blood pressure measurement (140/90 mm Hg) averaged over two sitting measurements in a clinical setting. A fully automatic system to analyze each image used conventional and deep neural network machine learning techniques to locate retinal landmarks and detect, classify and measure retinal vessels. From this data, a measure of the arteriolar-venular ratio (AVR) in the peripheral retina was calculated. Semi-automatic analysis was also performed. Results are presented in Table 1. Subjects had mean age of 54.6 ± 2.9 years; 56.1% (247 of 440) females, with 34.3% (151 of 440) subjects categorized as hypertensive. Narrower arterioles and smaller AVR were observed in subjects with hypertension. This was also observed in fully-automated analysis, however 4% (17 of 440) subjects failed to be processed by the system. In fully-automated analysis the area under a receiver operator characteristic curve of AVR for hypertensive status was 0.69 (95% CI, 0.63 to 0.74). Table 1 - Results for semi-automated and automated analysis of retinal vessel parameters. *p Automated measurement of AVR in ultra-widefield fundus imaging was associated with hypertension. With further development, such as evaluation against diagnosis of hypertension obtained from ambulatory blood pressure monitoring clinics, this system could become a test for undiagnosed hypertension in people attending routine eye health check-ups.
- 1 September 2018
- Published by Wolters Kluwer Health in Hypertension
- Vol. 72 (Suppl_1)
Abstract P400: Screening for Hypertension Using Retinal Vascular Calibre in Ultra-Widefield Fundus Imaging
Fundus images from the left eyes of 440 subjects aged 50-59 years enrolled in the Northern Ireland Cohort of Longitudinal Ageing were analyzed. Subjects were categorized as normotensive or hypertensive, according to thresholds on systolic/diastolic blood pressure measurement (140/90 mm Hg) averaged over two sitting measurements in a clinical setting. A fully automatic system to analyze each image used conventional and deep neural network machine learning techniques to locate retinal landmarks and detect, classify and measure retinal vessels. From this data, a measure of the arteriolar-venular ratio (AVR) in the peripheral retina was calculated. Semi-automatic analysis was also performed. Results are presented in Table 1. Subjects had mean age of 54.6 ± 2.9 years; 56.1% (247 of 440) females, with 34.3% (151 of 440) subjects categorized as hypertensive. Narrower arterioles and smaller AVR were observed in subjects with hypertension. This was also observed in fully-automated analysis, however 4% (17 of 440) subjects failed to be processed by the system. In fully-automated analysis the area under a receiver operator characteristic curve of AVR for hypertensive status was 0.69 (95% CI, 0.63 to 0.74). Table 1 - Results for semi-automated and automated analysis of retinal vessel parameters. *p Automated measurement of AVR in ultra-widefield fundus imaging was associated with hypertension. With further development, such as evaluation against diagnosis of hypertension obtained from ambulatory blood pressure monitoring clinics, this system could become a test for undiagnosed hypertension in people attending routine eye health check-ups.
- 13 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (2) , 516-526
A Graph Cut Approach to Artery/Vein Classification in Ultra-Widefield Scanning Laser Ophthalmoscopy
The classification of blood vessels into arterioles and venules is a fundamental step in the automatic investigation of retinal biomarkers for systemic diseases. In this paper we present a novel technique for vessel classification on ultra-wide-fieldof- view images of the retinal fundus acquired with a scanning laser ophthalmoscope. To our best knowledge, this is the first time that a fully automated artery/vein classification technique for this type of retinal imaging with no manual intervention has been presented. The proposed method exploits hand-crafted features based on local vessel intensity and vascular morphology to formulate a graph representation from which a globally optimal separation between the arterial and venular networks is computed by graph cut approach. The technique was tested on three different datasets (one publicly available and two local) and achieved an average classification accuracy of 0.883 in the largest dataset.
- 13 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (2) , 516-526
A Graph Cut Approach to Artery/Vein Classification in Ultra-Widefield Scanning Laser Ophthalmoscopy
The classification of blood vessels into arterioles and venules is a fundamental step in the automatic investigation of retinal biomarkers for systemic diseases. In this paper we present a novel technique for vessel classification on ultra-wide-fieldof- view images of the retinal fundus acquired with a scanning laser ophthalmoscope. To our best knowledge, this is the first time that a fully automated artery/vein classification technique for this type of retinal imaging with no manual intervention has been presented. The proposed method exploits hand-crafted features based on local vessel intensity and vascular morphology to formulate a graph representation from which a globally optimal separation between the arterial and venular networks is computed by graph cut approach. The technique was tested on three different datasets (one publicly available and two local) and achieved an average classification accuracy of 0.883 in the largest dataset.
- 19 August 2017
- Published by BMJ in British Journal of Ophthalmology
- Vol. 102 (4) , 483-489
Evaluation of coronary artery disease as a risk factor for reticular pseudodrusen
Purpose Reticular pseudodrusen (RPD) are a risk factor for late age-related macular degeneration (AMD). Associations between RPD and coronary artery disease (CAD) have been reported from small case–control studies. This study investigated the association of RPD within a predominantly CAD cohort. Methods A subgroup of subjects from a multicentre randomised controlled trial of CT coronary angiography (CTCA) underwent ultrawide field (UWF) retinal imaging CAD determined by CTCA and was categorised as normal, non-obstructive or obstructive. Specific AMD features in UWF images were graded. Standardised grids were used to record the spatial location of AMD features, including RPD. Multivariate confounder adjusted regression models assessed the association between RPD and CAD. Results The 534 participants were aged 27–75 years (mean 58±9 years; 425 (80%) ≥50 years) with a male preponderance (56%). Within the study sample, 178 (33%) had no CAD, 351 (66%) had CAD. RPD was detected in 30 participants (5.6%) and bilaterally in 23. Most participants with bilateral RPD had intermediate AMD 17 (74%). After adjustment for potential confounders (age, sex, drusen >125 µm, smoking status), multivariate analysis found no significant association between CAD and RPD (OR 1.31; 95% CI (0.57 to 3.01); p=0.52). A significant association was identified between RPD and intermediate AMD (OR 3.18; 95% CI (1.61 to 6.27); p=0.001). Conclusion We found no evidence to support an association between CAD and RPD. RPD was strongly associated with intermediate AMD features. Trial registration number NCT01149590, Post results.
- 19 August 2017
- Published by BMJ in British Journal of Ophthalmology
- Vol. 102 (4) , 483-489
Evaluation of coronary artery disease as a risk factor for reticular pseudodrusen
Purpose Reticular pseudodrusen (RPD) are a risk factor for late age-related macular degeneration (AMD). Associations between RPD and coronary artery disease (CAD) have been reported from small case–control studies. This study investigated the association of RPD within a predominantly CAD cohort. Methods A subgroup of subjects from a multicentre randomised controlled trial of CT coronary angiography (CTCA) underwent ultrawide field (UWF) retinal imaging CAD determined by CTCA and was categorised as normal, non-obstructive or obstructive. Specific AMD features in UWF images were graded. Standardised grids were used to record the spatial location of AMD features, including RPD. Multivariate confounder adjusted regression models assessed the association between RPD and CAD. Results The 534 participants were aged 27–75 years (mean 58±9 years; 425 (80%) ≥50 years) with a male preponderance (56%). Within the study sample, 178 (33%) had no CAD, 351 (66%) had CAD. RPD was detected in 30 participants (5.6%) and bilaterally in 23. Most participants with bilateral RPD had intermediate AMD 17 (74%). After adjustment for potential confounders (age, sex, drusen >125 µm, smoking status), multivariate analysis found no significant association between CAD and RPD (OR 1.31; 95% CI (0.57 to 3.01); p=0.52). A significant association was identified between RPD and intermediate AMD (OR 3.18; 95% CI (1.61 to 6.27); p=0.001). Conclusion We found no evidence to support an association between CAD and RPD. RPD was strongly associated with intermediate AMD features. Trial registration number NCT01149590, Post results.
- Open Access
- 17 November 2014
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 5 (12) , 4329-4337
Blood vessel segmentation and width estimation in ultra-wide field scanning laser ophthalmoscopy
Features of the retinal vasculature, such as vessel widths, are considered biomarkers for systemic disease. The aim of this work is to present a supervised approach to vessel segmentation in ultra-wide field of view scanning laser ophthalmoscope (UWFoV SLO) images and to evaluate its performance in terms of segmentation and vessel width estimation accuracy. The results of the proposed method are compared with ground truth measurements from human observers and with existing state-of-the-art techniques developed for fundus camera images that we optimized for UWFoV SLO images. Our algorithm is based on multi-scale matched filters, a neural network classifier and hysteresis thresholding. After spline-based refinement of the detected vessel contours, the vessel widths are estimated from the binary maps. Such analysis is performed on SLO images for the first time. The proposed method achieves the best results, both in vessel segmentation and in width estimation, in comparison to other automatic techniques.
- 17 November 2014
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 5 (12) , 4329-4337
Open AccessBlood vessel segmentation and width estimation in ultra-wide field scanning laser ophthalmoscopy
Features of the retinal vasculature, such as vessel widths, are considered biomarkers for systemic disease. The aim of this work is to present a supervised approach to vessel segmentation in ultra-wide field of view scanning laser ophthalmoscope (UWFoV SLO) images and to evaluate its performance in terms of segmentation and vessel width estimation accuracy. The results of the proposed method are compared with ground truth measurements from human observers and with existing state-of-the-art techniques developed for fundus camera images that we optimized for UWFoV SLO images. Our algorithm is based on multi-scale matched filters, a neural network classifier and hysteresis thresholding. After spline-based refinement of the detected vessel contours, the vessel widths are estimated from the binary maps. Such analysis is performed on SLO images for the first time. The proposed method achieves the best results, both in vessel segmentation and in width estimation, in comparison to other automatic techniques.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 441-444
Investigating post-processing of scanning laser ophthalmoscope images for unsupervised retinal blood vessel detection
We explore post-processing of scanning laser ophthalmoscope (SLO) images for the automatic detection of retinal blood vessels. The retinal vasculature is first enhanced using morphological and Gaussian matched filters before a thresholding technique produces a binary vessel map. Such permutations of post-processing techniques are commonly used to achieve unsupervised classification of the vasculature in fundus images, and it is the purpose of this study to investigate their applicability to SLO imaging. We compare the results of vascular detection as performed on SLO and fundus images.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 441-444
Investigating post-processing of scanning laser ophthalmoscope images for unsupervised retinal blood vessel detection
We explore post-processing of scanning laser ophthalmoscope (SLO) images for the automatic detection of retinal blood vessels. The retinal vasculature is first enhanced using morphological and Gaussian matched filters before a thresholding technique produces a binary vessel map. Such permutations of post-processing techniques are commonly used to achieve unsupervised classification of the vasculature in fundus images, and it is the purpose of this study to investigate their applicability to SLO imaging. We compare the results of vascular detection as performed on SLO and fundus images.