Tomasz Horwacik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tomasz Horwacik has a total of 132 co-authors. Here are the top co-authors by number of shared publications:
- Jan Swakoń
Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowski Street 152, 31-342 Krakow, Poland
14 shared publications - Pawel Olko
Institute of Nuclear Physics Polish Academy of Sciences, Krakow, Poland
12 shared publications - Pawel Bilski
Institute of Nuclear Physics, Polish Academy of Sciences, PL-31342 Kraków, Poland
8 shared publications - Tomasz Nowak
The Henryk Niewodniczański Institute of Nuclear Physics Polish Academy of Sciences, ul. Radzikowskiego 152, Kraków, Lesser Poland Voivodeship, 31-342, POLAND
5 shared publications - Hubert Jabłoński
Cyclotron Centre Bronowice, Institute of Nuclear Physics Polish Academy of Sciences, PL31342 Kraków, Poland
4 shared publications - Michał Sądel
Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow, Poland
4 shared publications
Latest Publications
- Open Access
High-Resolution MgB4O7:Ce,Li OSL Foils for Bragg Curve Mapping in Proton Eye Therapy
By using a PMMA-made therapeutic wedge and a recently developed reusable silicone foil dosimeter based on the optically stimulated luminescence (OSL) of MgB4O7:Ce,Li (MBO) material, direct measurements of the complete proton Bragg curves for two independent clinically relevant proton beams were achieved. The PMMA wedge compensator created a controlled range gradient across the beam field, enabling comprehensive characterisation of Bragg curve features, including the entrance plateau, the maximum of the Bragg peak, and the dosimetrically critical distal fall-off region. Measurements were performed using a dedicated, self-built (3D-printed) optical detection setup equipped with a blue LED (440 nm) that illuminates the MBO foil dosimeter and a highly sensitive electron-multiplication (EMCCD) camera, which simultaneously acquires 2D OSL light from the foil. The prototype technology enables single-shot 2D mapping of the complete Bragg curve. Validation against Monte Carlo (MC) simulations and GafchromicTM EBT3 films demonstrates sub-millimetre accuracy in localising the clinically critical proton parameters: peak-to-plateau, FWHM and distal fall-off. Measurements were performed for two independent therapeutic proton beams with initial energies of 58.8 and 61.1 MeV, routinely used for proton eye-beam treatments at IFJ PAN Krakow. As a proof of concept, the results demonstrate the potential of MBO-based silicone foil technology to reproduce clinically relevant Bragg-curve parameters with accuracy approaching that of the current gold standard for passive 2D dosimetry, GafchromicTM EBT3 films, while systematic differences attributable to optical diffusion, residual LET-dependent quenching, and the dual-foil junction remain to be corrected.
Open AccessHigh-Resolution MgB4O7:Ce,Li OSL Foils for Bragg Curve Mapping in Proton Eye Therapy
By using a PMMA-made therapeutic wedge and a recently developed reusable silicone foil dosimeter based on the optically stimulated luminescence (OSL) of MgB4O7:Ce,Li (MBO) material, direct measurements of the complete proton Bragg curves for two independent clinically relevant proton beams were achieved. The PMMA wedge compensator created a controlled range gradient across the beam field, enabling comprehensive characterisation of Bragg curve features, including the entrance plateau, the maximum of the Bragg peak, and the dosimetrically critical distal fall-off region. Measurements were performed using a dedicated, self-built (3D-printed) optical detection setup equipped with a blue LED (440 nm) that illuminates the MBO foil dosimeter and a highly sensitive electron-multiplication (EMCCD) camera, which simultaneously acquires 2D OSL light from the foil. The prototype technology enables single-shot 2D mapping of the complete Bragg curve. Validation against Monte Carlo (MC) simulations and GafchromicTM EBT3 films demonstrates sub-millimetre accuracy in localising the clinically critical proton parameters: peak-to-plateau, FWHM and distal fall-off. Measurements were performed for two independent therapeutic proton beams with initial energies of 58.8 and 61.1 MeV, routinely used for proton eye-beam treatments at IFJ PAN Krakow. As a proof of concept, the results demonstrate the potential of MBO-based silicone foil technology to reproduce clinically relevant Bragg-curve parameters with accuracy approaching that of the current gold standard for passive 2D dosimetry, GafchromicTM EBT3 films, while systematic differences attributable to optical diffusion, residual LET-dependent quenching, and the dual-foil junction remain to be corrected.
- 7 January 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (1) , 015006
Microdosimetric characterization of a clinical proton therapy beam: comparison between simulated lineal energy distributions in spherical water targets and experimental measurements with a silicon detector
Objective . Treatment planning based on computer simulations was proposed to account for the increased relative biological effectiveness (RBE) of proton radiotherapy beams near to the edges of the irradiated volume. Since silicon detectors could be used to validate the results of these simulations, it is important to explore the limitations of this comparison. Approach . Microdosimetric measurements with a MicroPlus Bridge V2 silicon detector (thickness = 10 μ m) were performed along the Bragg peak of a clinical proton beam. The lineal energy distributions, the dose-mean values, and the RBE calculated with a biological weighting function were compared with PHITS simulations (microdosimetric target = 1 μ m water sphere), and published clonogenic survival in vitro RBE data for the V79 cell line. The effect of the silicon-to-water conversion was also investigated by comparing three different methodologies (conversion based on a single value, novel bin-to-bin conversions based on SRIM and PSTAR). Main results . Mainly due to differences in the microdosimetric targets, the experimental dose-mean lineal energy and RBE values at the distal edge were respectively up to 53% and 28% lower than the simulated ones. Furthermore, the methodology chosen for the silicon-to-water conversion was proven to affect the dose-mean lineal energy and the RBE 10 up to 32% and 11% respectively. The best methodology to compensate for this underestimation was the bin-to-bin silicon-to-water conversion based on PSTAR. Significance . This work represents the first comparison between PHITS-simulated lineal energy distributions in water targets and corresponding experimental spectra measured with silicon detectors. Furthermore, the effect of the silicon-to-water conversion on the RBE was explored for the first time. The proposed methodology based on the PSTAR bin-to-bin conversion appears to provide superior results with respect to commonly used single scaling factors and is recommended for future studies.
- 7 January 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (1) , 015006
Microdosimetric characterization of a clinical proton therapy beam: comparison between simulated lineal energy distributions in spherical water targets and experimental measurements with a silicon detector
Objective . Treatment planning based on computer simulations was proposed to account for the increased relative biological effectiveness (RBE) of proton radiotherapy beams near to the edges of the irradiated volume. Since silicon detectors could be used to validate the results of these simulations, it is important to explore the limitations of this comparison. Approach . Microdosimetric measurements with a MicroPlus Bridge V2 silicon detector (thickness = 10 μ m) were performed along the Bragg peak of a clinical proton beam. The lineal energy distributions, the dose-mean values, and the RBE calculated with a biological weighting function were compared with PHITS simulations (microdosimetric target = 1 μ m water sphere), and published clonogenic survival in vitro RBE data for the V79 cell line. The effect of the silicon-to-water conversion was also investigated by comparing three different methodologies (conversion based on a single value, novel bin-to-bin conversions based on SRIM and PSTAR). Main results . Mainly due to differences in the microdosimetric targets, the experimental dose-mean lineal energy and RBE values at the distal edge were respectively up to 53% and 28% lower than the simulated ones. Furthermore, the methodology chosen for the silicon-to-water conversion was proven to affect the dose-mean lineal energy and the RBE 10 up to 32% and 11% respectively. The best methodology to compensate for this underestimation was the bin-to-bin silicon-to-water conversion based on PSTAR. Significance . This work represents the first comparison between PHITS-simulated lineal energy distributions in water targets and corresponding experimental spectra measured with silicon detectors. Furthermore, the effect of the silicon-to-water conversion on the RBE was explored for the first time. The proposed methodology based on the PSTAR bin-to-bin conversion appears to provide superior results with respect to commonly used single scaling factors and is recommended for future studies.
- Open Access
3D Dosimetry Based on LiMgPO4 OSL Silicone Foils: Facilitating the Verification of Eye-Ball Cancer Proton Radiotherapy
A direct verification of the three-dimensional (3D) proton clinical treatment plan prepared for tumor in the eyeball, using the Eclipse Ocular Proton Planning system (by Varian Medical Systems), has been presented. To achieve this, a prototype of the innovative two-dimensional (2D) circular silicone foils, made of a polymer with the embedded optically stimulated luminescence (OSL) material in powder form (LiMgPO4), and a self-developed optical imaging system, consisting of an illuminating light source and a high-sensitive CCD camera has been applied. A specially designed lifelike eyeball phantom has been used, constructed from 40 flat sheet LMP-based silicone foils stacked and placed together behind a spherical phantom made by polystyrene, all to reflect the curvature of the real eyeball. Two-dimensional OSL signals were captured and further analyzed from each single silicone foil after irradiation using a dedicated patient collimator and a 58.8 MeV modulated proton beam. The reconstructed 3D proton depth dose distribution matches very well with the clinical treatment plan, allowing for the consideration of the new OSL system for further 3D dosimetry applications within the proton radiotherapy area.
Open Access3D Dosimetry Based on LiMgPO4 OSL Silicone Foils: Facilitating the Verification of Eye-Ball Cancer Proton Radiotherapy
A direct verification of the three-dimensional (3D) proton clinical treatment plan prepared for tumor in the eyeball, using the Eclipse Ocular Proton Planning system (by Varian Medical Systems), has been presented. To achieve this, a prototype of the innovative two-dimensional (2D) circular silicone foils, made of a polymer with the embedded optically stimulated luminescence (OSL) material in powder form (LiMgPO4), and a self-developed optical imaging system, consisting of an illuminating light source and a high-sensitive CCD camera has been applied. A specially designed lifelike eyeball phantom has been used, constructed from 40 flat sheet LMP-based silicone foils stacked and placed together behind a spherical phantom made by polystyrene, all to reflect the curvature of the real eyeball. Two-dimensional OSL signals were captured and further analyzed from each single silicone foil after irradiation using a dedicated patient collimator and a 58.8 MeV modulated proton beam. The reconstructed 3D proton depth dose distribution matches very well with the clinical treatment plan, allowing for the consideration of the new OSL system for further 3D dosimetry applications within the proton radiotherapy area.
- 1 April 2020
- Published by Elsevier in Radiation Measurements
- Vol. 133
Two-dimensional radiation dosimetry based on LiMgPO4 powder embedded into silicone elastomer matrix
- 1 April 2020
- Published by Elsevier in Radiation Measurements
- Vol. 133
Two-dimensional radiation dosimetry based on LiMgPO4 powder embedded into silicone elastomer matrix
- 1 January 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (1) , 015008
Modeling the radiation-induced cell death in a therapeutic proton beam using thermoluminescent detectors and radiation transport simulations
Changes in the relative biological effectiveness (RBE) of the radiation-induced cell killing of human salivary glands (HSG) were assessed along the Bragg peak of a 60 MeV clinical proton beam by means of coupling biophysical models with the results of Monte Carlo radiation transport simulations and experimental measurements with luminescent detectors. The fluence- and dose-mean unrestricted proton LET were determined along the Bragg peak using a recently developed methodology based on the combination of the response of 7 LiF:Mg,Ti (MTS-7) and 7 LiF:Mg,Cu,P (MCP-7) thermoluminescent detectors. The experimentally assessed LET values were compared with the results of radiation transport simulations using the Monte Carlo code PHITS, showing a good agreement. The cell survival probabilities and RBE were then calculated using the linear-quadratic model with the linear term derived using a phenomenological LET-based model (Carabe A et al 2012 Phys. Med. Biol . 57 1159) in combination with the experimentally-assessed or PHITS-simulated dose mean proton LET values. To the same aim, PHITS simulated microdosimetric spectra were used as input to the modified microdosimetric kinetic model (modified MKM, (Kase et al 2006 Radiat. Res . 166 629–38)). The RBE values calculated with the three aforementioned approaches were compared and found to be in very good agreement between each other, proving that by using dedicated pairs of thermoluminescent detectors it is possible to determine ionization density quantities of therapeutic proton beams which can be applied to predict the local value of the RBE.
- 1 January 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (1) , 015008
Modeling the radiation-induced cell death in a therapeutic proton beam using thermoluminescent detectors and radiation transport simulations
Changes in the relative biological effectiveness (RBE) of the radiation-induced cell killing of human salivary glands (HSG) were assessed along the Bragg peak of a 60 MeV clinical proton beam by means of coupling biophysical models with the results of Monte Carlo radiation transport simulations and experimental measurements with luminescent detectors. The fluence- and dose-mean unrestricted proton LET were determined along the Bragg peak using a recently developed methodology based on the combination of the response of 7 LiF:Mg,Ti (MTS-7) and 7 LiF:Mg,Cu,P (MCP-7) thermoluminescent detectors. The experimentally assessed LET values were compared with the results of radiation transport simulations using the Monte Carlo code PHITS, showing a good agreement. The cell survival probabilities and RBE were then calculated using the linear-quadratic model with the linear term derived using a phenomenological LET-based model (Carabe A et al 2012 Phys. Med. Biol . 57 1159) in combination with the experimentally-assessed or PHITS-simulated dose mean proton LET values. To the same aim, PHITS simulated microdosimetric spectra were used as input to the modified microdosimetric kinetic model (modified MKM, (Kase et al 2006 Radiat. Res . 166 629–38)). The RBE values calculated with the three aforementioned approaches were compared and found to be in very good agreement between each other, proving that by using dedicated pairs of thermoluminescent detectors it is possible to determine ionization density quantities of therapeutic proton beams which can be applied to predict the local value of the RBE.
- Open Access
- 11 November 2016
- Published by EDP Sciences in Journal of Space Weather and Space Climate
- Vol. 6, A39
DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS)
Journal of Space Weather and Space Climate, a link between all the communities involved in Space Weather and in Space Climate
- 11 November 2016
- Published by EDP Sciences in Journal of Space Weather and Space Climate
- Vol. 6, A39
Open AccessDOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS)
Journal of Space Weather and Space Climate, a link between all the communities involved in Space Weather and in Space Climate
- 1 May 2016
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 95 (1) , 336-343
Practice Patterns Analysis of Ocular Proton Therapy Centers: The International OPTIC Survey
- 1 May 2016
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 95 (1) , 336-343
Practice Patterns Analysis of Ocular Proton Therapy Centers: The International OPTIC Survey