Miloš Müller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Miloš Müller has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Walter Neu
University of Applied Sciences Emden/Leer
3 shared publications - Jan Hujer
Department of Power Engineering Equipment, Faculty of Mechanical Engineering, Technical University of Liberec, Studentská 2, 461 17 Liberec, Czech Republic
2 shared publications - Jiří Unger
Faculty of Mechanical Engineering, Technical University of Liberec, Studentskâ 2, 46117, Liberec 1, Czech Republic
2 shared publications Michal Vyroubal
Centre of Hydraulic Research, J. Sigmunda 190, 783 49 Lutin, Czech Republic
2 shared publicationsPatrik Zima
Institute of Thermomechanics ASCR, v.v.i., Dolejškova 5, 182 00 Praha 8, Czech Republic
2 shared publications- Petr Schovanec
Faculty of mechatronics, Technical University of Liberec, Hálkova 6, 461 17 Liberec, Czech Republic
2 shared publications
Latest Publications
- Open Access
- 11 July 2022
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 264, 01024
Dynamic behaviour of cavitation bubble close to a flexible wall
The dynamic behaviour of cavitation bubble close to a flexible boundary is investigated experimentally. The cavitation bubble is produced as a consequence of an optical breakdown generated by the focus of 532 nm Nd-Yag laser beam. A gold mirror is used to focus the expanded laser beam into a spherically shaped plasma. A PVDF film sensor is used for the measurement of the interaction magnitude between the bubble and the flexible boundary. As the flexible boundary directly the PVFD film sensor is used. The sensor is flexibly mounted within a specially designed movable frame which enables to modify the elastic properties of the system. The bubble dynamics and the flexible wall movement are recorded by high-speed CCD camera and correlated with the acoustic signal obtained by the PVDF film. Different bubble collapse patters for different bubble wall distances and the corresponding acoustic signals are presented.
- 11 July 2022
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 264, 01024
Open AccessDynamic behaviour of cavitation bubble close to a flexible wall
The dynamic behaviour of cavitation bubble close to a flexible boundary is investigated experimentally. The cavitation bubble is produced as a consequence of an optical breakdown generated by the focus of 532 nm Nd-Yag laser beam. A gold mirror is used to focus the expanded laser beam into a spherically shaped plasma. A PVDF film sensor is used for the measurement of the interaction magnitude between the bubble and the flexible boundary. As the flexible boundary directly the PVFD film sensor is used. The sensor is flexibly mounted within a specially designed movable frame which enables to modify the elastic properties of the system. The bubble dynamics and the flexible wall movement are recorded by high-speed CCD camera and correlated with the acoustic signal obtained by the PVDF film. Different bubble collapse patters for different bubble wall distances and the corresponding acoustic signals are presented.
- Open Access
Photolithographically Home-Made PVDF Sensor for Cavitation Impact Load Measurement
Piezoelectric PVDF sensors offer a unique option for the measurement of cavitation aggressiveness represented by the magnitude of impacts due to cavitation bubble collapses near walls. The aggressiveness measurement requires specific sensor shape and area, whereas commercial PVDF sensors are fabricated in limited geometry and size ranges. The photolithography method offers a possibility of production of home-made PVDF sensors of arbitrary shape and size. The methodology of a unique application of the standard photolithography method, which is commonly used for the production of printed circuit boards, is described in this paper. It enables mass production of high quality sensors contrary to laboratory techniques. This paper deals with the fabrication and the calibration of a photolithographically home-made PVDF sensor for the cavitation impact load measurement. The calibration of sensors was carried out by the ball drop method. Sensors of different sizes were fabricated by the photolithography method from a multi-purpose, both side metallized PVDF sheet. Commercial PVDF sensors of the same size were calibrated, and the calibration results were compared with the home-made sensors. The effect of size and the effect of one added protective layer of Kapton tape on a sensor sensitivity were investigated. The theoretical and numerical analysis was conducted to explain some issues during the ball impact.
Open AccessPhotolithographically Home-Made PVDF Sensor for Cavitation Impact Load Measurement
Piezoelectric PVDF sensors offer a unique option for the measurement of cavitation aggressiveness represented by the magnitude of impacts due to cavitation bubble collapses near walls. The aggressiveness measurement requires specific sensor shape and area, whereas commercial PVDF sensors are fabricated in limited geometry and size ranges. The photolithography method offers a possibility of production of home-made PVDF sensors of arbitrary shape and size. The methodology of a unique application of the standard photolithography method, which is commonly used for the production of printed circuit boards, is described in this paper. It enables mass production of high quality sensors contrary to laboratory techniques. This paper deals with the fabrication and the calibration of a photolithographically home-made PVDF sensor for the cavitation impact load measurement. The calibration of sensors was carried out by the ball drop method. Sensors of different sizes were fabricated by the photolithography method from a multi-purpose, both side metallized PVDF sheet. Commercial PVDF sensors of the same size were calibrated, and the calibration results were compared with the home-made sensors. The effect of size and the effect of one added protective layer of Kapton tape on a sensor sensitivity were investigated. The theoretical and numerical analysis was conducted to explain some issues during the ball impact.
- Open Access
- 5 October 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 210, 04015
Preliminary investigation of centrifugal pump for fire engine
This preliminary work deals with analytical, numerical and experimental investigation of centrifugal pump for fire engine. The pump was investigated experimentally and power curves as dependence of head on flow rate were carried out. Numerical research focused on finding of setup of numerical solver. All curves were compared, analysed and problematic places were identified. It was found that for very low backpressure, i.e. head coefficient, cavitation occurs around the propeller wheel and reduces maximum flow coefficient significantly. After modifying the wheel by sharpening leading edges of blades, or when rotation speed was increased, cavitation got even worse. Another issue is related with stator blades. It seems that stator blades work perfectly only in short range of regimes. Stator blades represent another resistance for low back pressure, while for higher back pressure, stator blades fail to decelerate the flow and increase static pressure. Several modification were suggested to increase performance of the fire engine.
- 5 October 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 210, 04015
Open AccessPreliminary investigation of centrifugal pump for fire engine
This preliminary work deals with analytical, numerical and experimental investigation of centrifugal pump for fire engine. The pump was investigated experimentally and power curves as dependence of head on flow rate were carried out. Numerical research focused on finding of setup of numerical solver. All curves were compared, analysed and problematic places were identified. It was found that for very low backpressure, i.e. head coefficient, cavitation occurs around the propeller wheel and reduces maximum flow coefficient significantly. After modifying the wheel by sharpening leading edges of blades, or when rotation speed was increased, cavitation got even worse. Another issue is related with stator blades. It seems that stator blades work perfectly only in short range of regimes. Stator blades represent another resistance for low back pressure, while for higher back pressure, stator blades fail to decelerate the flow and increase static pressure. Several modification were suggested to increase performance of the fire engine.
- Open Access
- 4 June 2018
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 180, 02036
Calibration of PVDF Film Transducers for the Cavitation Impact Measurement
This paper describes investigation of the influence of the protective layer thickness on the calibration sensitivity of PVDF films sensors for the cavitation impacts measurements. The PVDF film sensor is casted into an aluminium block. The drop ball method is used for the measurement of the relation between impact force and the voltage detected on the PVDF film sensor. The calibration constants are measured for three different protective layers thicknesses. Five different ball weights for 400 mm drop height are used to reach the required impact force range. The ball positions for the evaluation of the impact force are measured with a high speed camera. The voltage signal detected on the PVDF film clamps was measured with a high speed digitizer. The measured signals are analysed in LabVIEW Signal Express.
- 4 June 2018
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 180, 02036
Open AccessCalibration of PVDF Film Transducers for the Cavitation Impact Measurement
This paper describes investigation of the influence of the protective layer thickness on the calibration sensitivity of PVDF films sensors for the cavitation impacts measurements. The PVDF film sensor is casted into an aluminium block. The drop ball method is used for the measurement of the relation between impact force and the voltage detected on the PVDF film sensor. The calibration constants are measured for three different protective layers thicknesses. Five different ball weights for 400 mm drop height are used to reach the required impact force range. The ball positions for the evaluation of the impact force are measured with a high speed camera. The voltage signal detected on the PVDF film clamps was measured with a high speed digitizer. The measured signals are analysed in LabVIEW Signal Express.
- Open Access
- 12 May 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 143, 02119
The improvement of the surface hardness of stainless steel and aluminium alloy by ultrasonic cavitation peening
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 12 May 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 143, 02119
Open AccessThe improvement of the surface hardness of stainless steel and aluminium alloy by ultrasonic cavitation peening
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- Open Access
- 12 May 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 143, 02044
Comparison of ultrasound and LIB generated cavitation bubble
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 12 May 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 143, 02044
Open AccessComparison of ultrasound and LIB generated cavitation bubble
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 11 November 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 101510L-101510L-6
Experimental setup for laser-induced breakdown in aqueous media
- 11 November 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 101510L-101510L-6
Experimental setup for laser-induced breakdown in aqueous media
- Open Access
- 3 December 2015
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 656 (1) , 012051
Impact load measurements with a PVDF pressure sensor in an erosive cavitating flow
A PVDF pressure sensor was used to measure the pressure peaks due to the collapse of cavitation bubbles in the high-speed tunnel of the LEGI laboratory. It was flush mounted on a stainless steel disk in the most erosive area of the test section. The recorded data were post- processed in order to get the impact load spectra for different velocities at constant cavitation number. The results are presented as cumulative histograms of peak rate and maximal impact load for different flow velocities of the high-speed tunnel.
- 3 December 2015
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 656 (1) , 012051
Open AccessImpact load measurements with a PVDF pressure sensor in an erosive cavitating flow
A PVDF pressure sensor was used to measure the pressure peaks due to the collapse of cavitation bubbles in the high-speed tunnel of the LEGI laboratory. It was flush mounted on a stainless steel disk in the most erosive area of the test section. The recorded data were post- processed in order to get the impact load spectra for different velocities at constant cavitation number. The results are presented as cumulative histograms of peak rate and maximal impact load for different flow velocities of the high-speed tunnel.
- Open Access
- 6 May 2015
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 92, 02036
Preparation of experimental and numerical research on unsteady cavitating flow around hydrofoil
EPJ Web of Conferences, open-access proceedings in physics and related sciences
- 6 May 2015
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 92, 02036
Open AccessPreparation of experimental and numerical research on unsteady cavitating flow around hydrofoil
EPJ Web of Conferences, open-access proceedings in physics and related sciences
- Open Access
- 9 April 2013
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 45, 01057
Fin Distance Effect at Tube-Fin Heat Exchanger
EPJ Web of Conferences, open-access proceedings in physics and related sciences
- 9 April 2013
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 45, 01057
Open AccessFin Distance Effect at Tube-Fin Heat Exchanger
EPJ Web of Conferences, open-access proceedings in physics and related sciences