Carla Ribalta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carla Ribalta has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Mar Viana
Institute of Environmental Assessment and Water Research - Spanish Research council (IDAEA-CSIC), Barcelona, 08034, Spain; Spanish Ministry of Ecological Transition, Pollution Prevention Unit, Pza. San Juan de la Cruz 10, 28071, Madrid, Spain
4 shared publications - Ana López Lilao
Institute of Ceramic Technology (ITC)- AICE - Universitat Jaume I, Campus Universitario Riu Sec, Av. Vicent Sos Baynat s/n, 12006 Castellón, Spain
3 shared publications Eliseo Monfort
Institute of Ceramic Technology (ITC) - AICE - Universitat Jaume I, Campus Universitario Riu Sec, Av. Vicent Sos Baynat s/n, 12006 Castellón, Spain
3 shared publications- Eliseo Montfort
Institute of Ceramic Technology (ITC), Universitat Jaume I, Castellón, Spain
3 shared publications Ana López-Lilao
Institute of Ceramic Technology (ITC) - AICE - Universitat Jaume I, Campus Universitario Riu Sec, Av. Vicent Sos Baynat s/n, 12006 Castellón, Spain
2 shared publications- Ana Sofia Fonseca
The National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark
2 shared publications
Latest Publications
A Screening Approach to the Safe‐and‐Sustainable‐by‐Design Development of Advanced Insulation Materials
Herein, a Safe‐and‐Sustainable‐by‐Design (SSbD) screening strategy on four different inorganic aerogel mats and two conventional mineral wools for ranking purposes is demonstrated. Given that they do not consist of particles, the release is first simulated, addressing three occupational exposure scenarios, realistic for their intended use as building insulators. No exposure to consumers nor to the environment is foreseen in the use phase, however, aerosols may be released during mat installation, posing an inhalation risk for workers. All four aerogel mats release more respirable dust than the benchmark materials and 60% thereof deposits in the alveolar region according to modelling tools. The collected aerogel dust allows for subsequent screening of hazard implications via two abiotic assays: 1) surface reactivity in human blood serum; 2) biodissolution kinetics in lung simulant fluids. Both aerogels and conventional insulators show similar surface reactivity. Differences in biodissolution are influenced by the specifically designed organic and inorganic structural modifications. Aerogel mats are better‐performing insulators (2‐fold lower thermal conductivity than the benchmark) However, this work demonstrates how investment decisions can be balanced with safety and sustainability aspects. Concepts of analogy and similarity thus support easily accessible methods to companies for safe and economically viable innovation with advanced materials.
A Screening Approach to the Safe‐and‐Sustainable‐by‐Design Development of Advanced Insulation Materials
Herein, a Safe‐and‐Sustainable‐by‐Design (SSbD) screening strategy on four different inorganic aerogel mats and two conventional mineral wools for ranking purposes is demonstrated. Given that they do not consist of particles, the release is first simulated, addressing three occupational exposure scenarios, realistic for their intended use as building insulators. No exposure to consumers nor to the environment is foreseen in the use phase, however, aerosols may be released during mat installation, posing an inhalation risk for workers. All four aerogel mats release more respirable dust than the benchmark materials and 60% thereof deposits in the alveolar region according to modelling tools. The collected aerogel dust allows for subsequent screening of hazard implications via two abiotic assays: 1) surface reactivity in human blood serum; 2) biodissolution kinetics in lung simulant fluids. Both aerogels and conventional insulators show similar surface reactivity. Differences in biodissolution are influenced by the specifically designed organic and inorganic structural modifications. Aerogel mats are better‐performing insulators (2‐fold lower thermal conductivity than the benchmark) However, this work demonstrates how investment decisions can be balanced with safety and sustainability aspects. Concepts of analogy and similarity thus support easily accessible methods to companies for safe and economically viable innovation with advanced materials.
- Open Access
Evaluation of One- and Two-Box Models as Particle Exposure Prediction Tools at Industrial Scale
One- and two-box models have been pointed out as useful tools for modelling indoor particle exposure. However, model performance still needs further testing if they are to be implemented as trustworthy tools for exposure assessment. The objective of this work is to evaluate the performance, applicability and reproducibility of one- and two-box models on real-world industrial scenarios. A study on filling of seven materials in three filling lines with different levels of energy and mitigation strategies was used. Inhalable and respirable mass concentrations were calculated with one- and two-box models. The continuous drop and rotating drum methods were used for emission rate calculation, and ranges from a one-at-a-time methodology were applied for local exhaust ventilation efficiency and inter-zonal air flows. When using both dustiness methods, large differences were observed for modelled inhalable concentrations but not for respirable, which showed the importance to study the linkage between dustiness and processes. Higher model accuracy (ratio modelled vs. measured concentrations 0.5–5) was obtained for the two- (87%) than the one-box model (53%). Large effects on modelled concentrations were seen when local exhausts ventilation and inter-zonal variations where parametrized in the models. However, a certain degree of variation (10–20%) seems acceptable, as similar conclusions are reached.
Open AccessEvaluation of One- and Two-Box Models as Particle Exposure Prediction Tools at Industrial Scale
One- and two-box models have been pointed out as useful tools for modelling indoor particle exposure. However, model performance still needs further testing if they are to be implemented as trustworthy tools for exposure assessment. The objective of this work is to evaluate the performance, applicability and reproducibility of one- and two-box models on real-world industrial scenarios. A study on filling of seven materials in three filling lines with different levels of energy and mitigation strategies was used. Inhalable and respirable mass concentrations were calculated with one- and two-box models. The continuous drop and rotating drum methods were used for emission rate calculation, and ranges from a one-at-a-time methodology were applied for local exhaust ventilation efficiency and inter-zonal air flows. When using both dustiness methods, large differences were observed for modelled inhalable concentrations but not for respirable, which showed the importance to study the linkage between dustiness and processes. Higher model accuracy (ratio modelled vs. measured concentrations 0.5–5) was obtained for the two- (87%) than the one-box model (53%). Large effects on modelled concentrations were seen when local exhausts ventilation and inter-zonal variations where parametrized in the models. However, a certain degree of variation (10–20%) seems acceptable, as similar conclusions are reached.
- Open Access
- 1 June 2019
- Published by Elsevier in Science of The Total Environment
- Vol. 671, 474-487
Health risk assessment from exposure to particles during packing in working environments
- 1 June 2019
- Published by Elsevier in Science of The Total Environment
- Vol. 671, 474-487
Open AccessHealth risk assessment from exposure to particles during packing in working environments
- Open Access
- 14 May 2019
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (10) , 1695
Modeling of High Nanoparticle Exposure in an Indoor Industrial Scenario with a One-Box Model
Mass balance models have proved to be effective tools for exposure prediction in occupational settings. However, they are still not extensively tested in real-world scenarios, or for particle number concentrations. An industrial scenario characterized by high emissions of unintentionally-generated nanoparticles (NP) was selected to assess the performance of a one-box model. Worker exposure to NPs due to thermal spraying was monitored, and two methods were used to calculate emission rates: the convolution theorem, and the cyclic steady state equation. Monitored concentrations ranged between 4.2 × 104–2.5 × 105 cm−3. Estimated emission rates were comparable with both methods: 1.4 × 1011–1.2 × 1013 min−1 (convolution) and 1.3 × 1012–1.4 × 1013 min−1 (cyclic steady state). Modeled concentrations were 1.4-6 × 104 cm−3 (convolution) and 1.7–7.1 × 104 cm−3 (cyclic steady state). Results indicated a clear underestimation of measured particle concentrations, with ratios modeled/measured between 0.2–0.7. While both model parametrizations provided similar results on average, using convolution emission rates improved performance on a case-by-case basis. Thus, using cyclic steady state emission rates would be advisable for preliminary risk assessment, while for more precise results, the convolution theorem would be a better option. Results show that one-box models may be useful tools for preliminary risk assessment in occupational settings when room air is well mixed.
- 14 May 2019
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (10) , 1695
Open AccessModeling of High Nanoparticle Exposure in an Indoor Industrial Scenario with a One-Box Model
Mass balance models have proved to be effective tools for exposure prediction in occupational settings. However, they are still not extensively tested in real-world scenarios, or for particle number concentrations. An industrial scenario characterized by high emissions of unintentionally-generated nanoparticles (NP) was selected to assess the performance of a one-box model. Worker exposure to NPs due to thermal spraying was monitored, and two methods were used to calculate emission rates: the convolution theorem, and the cyclic steady state equation. Monitored concentrations ranged between 4.2 × 104–2.5 × 105 cm−3. Estimated emission rates were comparable with both methods: 1.4 × 1011–1.2 × 1013 min−1 (convolution) and 1.3 × 1012–1.4 × 1013 min−1 (cyclic steady state). Modeled concentrations were 1.4-6 × 104 cm−3 (convolution) and 1.7–7.1 × 104 cm−3 (cyclic steady state). Results indicated a clear underestimation of measured particle concentrations, with ratios modeled/measured between 0.2–0.7. While both model parametrizations provided similar results on average, using convolution emission rates improved performance on a case-by-case basis. Thus, using cyclic steady state emission rates would be advisable for preliminary risk assessment, while for more precise results, the convolution theorem would be a better option. Results show that one-box models may be useful tools for preliminary risk assessment in occupational settings when room air is well mixed.
- 1 February 2019
- Published by Elsevier in Science of The Total Environment
- Vol. 650, 2423-2436
Testing the performance of one and two box models as tools for risk assessment of particle exposure during packing of inorganic fertilizer
- 1 February 2019
- Published by Elsevier in Science of The Total Environment
- Vol. 650, 2423-2436
Testing the performance of one and two box models as tools for risk assessment of particle exposure during packing of inorganic fertilizer
- 14 December 2018
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 63 (1) , 91-106
Workplace Exposure to Nanoparticles during Thermal Spraying of Ceramic Coatings
Thermal spraying is widely used for industrial-scale application of ceramic coatings onto metallic surfaces. The particular process has implications for occupational health, as the high energy process generates high emissions of metal-bearing nanoparticles. Emissions and their impact on exposure were characterized during thermal spraying in a work environment, by monitoring size-resolved number and mass concentrations, lung-deposited surface area, particle morphology, and chemical composition. Along with exposure quantification, the modal analysis of the emissions assisted in distinguishing particles from different sources, while an inhalation model provided evidence regarding the potential deposition of particulate matter on human respiratory system. High particle number (>10(6) cm-3; 30-40 nm) and mass (60-600 µgPM1 m-3) concentrations were recorded inside the spraying booths, which impacted exposure in the worker area (10(4)-10(5) cm-3, 40-65 nm; 44-87 µgPM1 m-3). Irregularly-shaped, metal-containing particles (Ni, Cr, W) were sampled from the worker area, as single particles and aggregates (5-200 nm). Energy dispersive X-ray analysis confirmed the presence of particles originated from the coating material, establishing a direct link between the spraying activity and exposure. In particle number count, 90% of the particles were between 26-90 nm. Inhaled dose rates, calculated from the exposure levels, resulted in particle number rates (n˙) between 353 × 10(6)-1024 × 10(6) min-1, with 70% of deposition occurring in the alveolar region. The effectiveness of personal protective equipment (FPP3 masks) was tested under real working conditions. The proper sealing of the spraying booths was identified as a key element for exposure reduction. This study provides high time-resolved aerosol data which may be valuable for validating indoor aerosol models applied to risk assessment.
- 14 December 2018
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 63 (1) , 91-106
Workplace Exposure to Nanoparticles during Thermal Spraying of Ceramic Coatings
Thermal spraying is widely used for industrial-scale application of ceramic coatings onto metallic surfaces. The particular process has implications for occupational health, as the high energy process generates high emissions of metal-bearing nanoparticles. Emissions and their impact on exposure were characterized during thermal spraying in a work environment, by monitoring size-resolved number and mass concentrations, lung-deposited surface area, particle morphology, and chemical composition. Along with exposure quantification, the modal analysis of the emissions assisted in distinguishing particles from different sources, while an inhalation model provided evidence regarding the potential deposition of particulate matter on human respiratory system. High particle number (>10(6) cm-3; 30-40 nm) and mass (60-600 µgPM1 m-3) concentrations were recorded inside the spraying booths, which impacted exposure in the worker area (10(4)-10(5) cm-3, 40-65 nm; 44-87 µgPM1 m-3). Irregularly-shaped, metal-containing particles (Ni, Cr, W) were sampled from the worker area, as single particles and aggregates (5-200 nm). Energy dispersive X-ray analysis confirmed the presence of particles originated from the coating material, establishing a direct link between the spraying activity and exposure. In particle number count, 90% of the particles were between 26-90 nm. Inhaled dose rates, calculated from the exposure levels, resulted in particle number rates (n˙) between 353 × 10(6)-1024 × 10(6) min-1, with 70% of deposition occurring in the alveolar region. The effectiveness of personal protective equipment (FPP3 masks) was tested under real working conditions. The proper sealing of the spraying booths was identified as a key element for exposure reduction. This study provides high time-resolved aerosol data which may be valuable for validating indoor aerosol models applied to risk assessment.
- 1 December 2018
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 63 (1) , 107-123
On the Relationship between Exposure to Particles and Dustiness during Handling of Powders in Industrial Settings
Exposure to ceramic powders, which is frequent during handling operations, is known to cause adverse health effects. Finding proxy parameters to quantify exposure is useful for efficient and timely exposure assessments. Worker exposure during handling of five materials [a silica sand (SI1), three quartzes (Q1, Q2, and Q3), and a kaolin (K1)] with different particle shape (prismatic and platy) and sizes (3.4-120 µm) was assessed. Materials handling was simulated using a dry pendular mill under two different energy settings (low and high). Three repetitions of two kilos of material were carried out per material and energy conditions with a flow rate of 8-11 kg h-1. The performance of the dustiness index as a predictor of worker exposure was evaluated correlating material's dustiness indexes (with rotating drum and continuous drop) with exposure concentrations. Significant impacts on worker exposure in terms of inhalable and respirable mass fractions were detected for all materials. Mean inhalable mass concentrations during background were always lower than 40 µg m-3 whereas during material handling under high energy settings mean concentrations were 187, 373, 243, 156, and 430 µg m-3 for SI1, Q1, Q2, Q3, and K1, respectively. Impacts were not significant with regard to particle number concentration: background particle number concentrations ranged between 10 620 and 46 421 cm-3 while during handling under high energy settings they were 20 880 - 40 498 cm-3. Mean lung deposited surface area during background ranged between 27 and 101 μm2 cm-3 whereas it ranged between 22 and 42 μm2 cm-3 during materials handling. TEM images evidenced the presence of nanoparticles (≤100 nm) in the form of aggregates (300 nm-1 µm) in the worker area, and a slight reduction on mean particle size during handling was detected. Dustiness and exposure concentrations showed a high degree of correlation (R2 = 0.77-0.97) for the materials and operating conditions assessed, suggesting that dustiness could be considered a relevant predictor for workplace exposure. Nevertheless, the relationship between dustiness and exposure is complex and should be assessed for each process, taking into account not only material behaviour but also energy settings and workplace characteristics.
- 1 December 2018
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 63 (1) , 107-123
On the Relationship between Exposure to Particles and Dustiness during Handling of Powders in Industrial Settings
Exposure to ceramic powders, which is frequent during handling operations, is known to cause adverse health effects. Finding proxy parameters to quantify exposure is useful for efficient and timely exposure assessments. Worker exposure during handling of five materials [a silica sand (SI1), three quartzes (Q1, Q2, and Q3), and a kaolin (K1)] with different particle shape (prismatic and platy) and sizes (3.4-120 µm) was assessed. Materials handling was simulated using a dry pendular mill under two different energy settings (low and high). Three repetitions of two kilos of material were carried out per material and energy conditions with a flow rate of 8-11 kg h-1. The performance of the dustiness index as a predictor of worker exposure was evaluated correlating material's dustiness indexes (with rotating drum and continuous drop) with exposure concentrations. Significant impacts on worker exposure in terms of inhalable and respirable mass fractions were detected for all materials. Mean inhalable mass concentrations during background were always lower than 40 µg m-3 whereas during material handling under high energy settings mean concentrations were 187, 373, 243, 156, and 430 µg m-3 for SI1, Q1, Q2, Q3, and K1, respectively. Impacts were not significant with regard to particle number concentration: background particle number concentrations ranged between 10 620 and 46 421 cm-3 while during handling under high energy settings they were 20 880 - 40 498 cm-3. Mean lung deposited surface area during background ranged between 27 and 101 μm2 cm-3 whereas it ranged between 22 and 42 μm2 cm-3 during materials handling. TEM images evidenced the presence of nanoparticles (≤100 nm) in the form of aggregates (300 nm-1 µm) in the worker area, and a slight reduction on mean particle size during handling was detected. Dustiness and exposure concentrations showed a high degree of correlation (R2 = 0.77-0.97) for the materials and operating conditions assessed, suggesting that dustiness could be considered a relevant predictor for workplace exposure. Nevertheless, the relationship between dustiness and exposure is complex and should be assessed for each process, taking into account not only material behaviour but also energy settings and workplace characteristics.
- 1 November 2015
- Published by Elsevier in Science of The Total Environment
- Vol. 532, 176-183
Hepatic biotransformation and antioxidant enzyme activities in Mediterranean fish from different habitat depths
- 1 November 2015
- Published by Elsevier in Science of The Total Environment
- Vol. 532, 176-183
Hepatic biotransformation and antioxidant enzyme activities in Mediterranean fish from different habitat depths
- 16 September 2014
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 48 (20) , 12327-12335
In Vitro Interaction of Emerging Contaminants with the Cytochrome P450 System of Mediterranean Deep-Sea Fish
The interactions of emerging contaminants with the xenobiotic and endogenous metabolizing system of deep-sea fish were compared. The drugs diclofenac, fluoxetine, and gemfibrozil belong to different pharmaceutical classes with diverse mechanistic actions, and the personal care products triclosan, galaxolide, and nonylphenol are representative of antibacterial agents, nitro-musks, and surfactants, respectively. The fish compared are representative of the middle and lower slope of deep-sea habitats. The species were adults of Trachyrynchus scabrus, Mora moro, Cataetix laticeps, and Alepocehalus rostratus. The hepatic metabolic system studied were the activities associated with several cytochrome P450 isoforms (CYPs): 7-ethoxyresorufin-O-deethylase (EROD), benzyloxy-4-[trifluoromethyl]-coumarin-O-debenzyloxylase (BFCOD), and 7-ethoxycoumarin-O-deethylase (ECOD). Results showed differences in baseline activities and sensitivity to chemicals which were species, chemical, and pathway dependent. T. scabrous was the most sensitive species to chemical interactions with the xenobiotic and endogenous metabolizing (EROD and BFCOD) systems, especially in the case of diclofenac interference with BFCOD activity (IC50 = 15.7 ± 2.2 μM). Moreover, T. scabrous and A. rostratus possessed high basal ECOD activity, and this was greatly affected by in vitro exposure to diclofenac in T. scabrous also (IC50 = 6.86 ± 1.4 μM). These results highlight the sensitivity of marine fish to emerging contaminants and propose T. scabrous (middle slope) and A. rostratus (lower slope) as sentinels and the inclusion of ECOD activity as a sensitive biomarker to these exposures.
- 16 September 2014
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 48 (20) , 12327-12335
In Vitro Interaction of Emerging Contaminants with the Cytochrome P450 System of Mediterranean Deep-Sea Fish
The interactions of emerging contaminants with the xenobiotic and endogenous metabolizing system of deep-sea fish were compared. The drugs diclofenac, fluoxetine, and gemfibrozil belong to different pharmaceutical classes with diverse mechanistic actions, and the personal care products triclosan, galaxolide, and nonylphenol are representative of antibacterial agents, nitro-musks, and surfactants, respectively. The fish compared are representative of the middle and lower slope of deep-sea habitats. The species were adults of Trachyrynchus scabrus, Mora moro, Cataetix laticeps, and Alepocehalus rostratus. The hepatic metabolic system studied were the activities associated with several cytochrome P450 isoforms (CYPs): 7-ethoxyresorufin-O-deethylase (EROD), benzyloxy-4-[trifluoromethyl]-coumarin-O-debenzyloxylase (BFCOD), and 7-ethoxycoumarin-O-deethylase (ECOD). Results showed differences in baseline activities and sensitivity to chemicals which were species, chemical, and pathway dependent. T. scabrous was the most sensitive species to chemical interactions with the xenobiotic and endogenous metabolizing (EROD and BFCOD) systems, especially in the case of diclofenac interference with BFCOD activity (IC50 = 15.7 ± 2.2 μM). Moreover, T. scabrous and A. rostratus possessed high basal ECOD activity, and this was greatly affected by in vitro exposure to diclofenac in T. scabrous also (IC50 = 6.86 ± 1.4 μM). These results highlight the sensitivity of marine fish to emerging contaminants and propose T. scabrous (middle slope) and A. rostratus (lower slope) as sentinels and the inclusion of ECOD activity as a sensitive biomarker to these exposures.