Tomáš Luks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tomáš Luks has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Alain Ehrlacher
Brno University of Technology
4 shared publications- Daniel Weisz-Patrault
Université Paris-Est
4 shared publications Nathalie Labbe
ArcelorMittal Global Research and Development
4 shared publicationsNicolas Legrand
ArcelorMittal Global Research and Development
4 shared publicationsJaroslav Horský
Brno University of Technology
3 shared publications- Jaroslav Horsky
Brno University of Technology
2 shared publications
Latest Publications
- 13 June 2013
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 554-557, 1555-1569
Characterization of Roll Bite Heat Transfers in Hot Steel Strip Rolling and their Influence on Roll Thermal Fatigue Degradation
A temperature sensor with a thermocouple placed at ~0.5 mm from roll surface is used in hot rolling conditions to evaluate by inverse calculation heat transfers in the roll bite. Simulation analysis in industrial hot rolling conditions with short contact lengths (e.g. short contact times) and high rolling speeds (7 m./sec.) show that the temperature sensor + inverse analysis with a high acquisition frequency (> 1000 Hz) is capable to predict with a good accuracy (5 to 10% error) the roll bite peak of temperature as well as the roll surface temperature evolution all around the roll rotation. However as heat flux is more sensitive to noise measurement, the peak of heat flux in the bite is strongly under-estimated (40% error) by the inverse calculation and thus only an average roll bite heat flux could be expected from the sensor (these simulation results will be verified with an industrial trial that is being prepared). Rolling tests on a pilot mill with low rolling speeds (from 0.3 to 1.5 m./sec.) and strip reductions varying from 10 to 40% have been performed with the temperature sensor. Analysis of the tests by inverse calculation show that at low speed (roll-bite (characterizing heat transfers between roll and strip in the bite) is not uniform along the roll bite but is proportional to the local rolling pressure. Finally, based on the above results, simulations with a roll thermal fatigue degradation model in industrial hot rolling conditions show that the non uniform roll bite Heat Transfer Coefficient HTCroll-bite may have in certain rolling conditions a stronger influence on roll thermal fatigue degradation than the equivalent (e.g. same average) HTCroll-bite taken uniform along the bite. Consequently, to be realistic the roll thermal fatigue degradation model has to incorporate this non uniform HTCroll-bite.
- 13 June 2013
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 554-557, 1555-1569
Characterization of Roll Bite Heat Transfers in Hot Steel Strip Rolling and their Influence on Roll Thermal Fatigue Degradation
A temperature sensor with a thermocouple placed at ~0.5 mm from roll surface is used in hot rolling conditions to evaluate by inverse calculation heat transfers in the roll bite. Simulation analysis in industrial hot rolling conditions with short contact lengths (e.g. short contact times) and high rolling speeds (7 m./sec.) show that the temperature sensor + inverse analysis with a high acquisition frequency (> 1000 Hz) is capable to predict with a good accuracy (5 to 10% error) the roll bite peak of temperature as well as the roll surface temperature evolution all around the roll rotation. However as heat flux is more sensitive to noise measurement, the peak of heat flux in the bite is strongly under-estimated (40% error) by the inverse calculation and thus only an average roll bite heat flux could be expected from the sensor (these simulation results will be verified with an industrial trial that is being prepared). Rolling tests on a pilot mill with low rolling speeds (from 0.3 to 1.5 m./sec.) and strip reductions varying from 10 to 40% have been performed with the temperature sensor. Analysis of the tests by inverse calculation show that at low speed (roll-bite (characterizing heat transfers between roll and strip in the bite) is not uniform along the roll bite but is proportional to the local rolling pressure. Finally, based on the above results, simulations with a roll thermal fatigue degradation model in industrial hot rolling conditions show that the non uniform roll bite Heat Transfer Coefficient HTCroll-bite may have in certain rolling conditions a stronger influence on roll thermal fatigue degradation than the equivalent (e.g. same average) HTCroll-bite taken uniform along the bite. Consequently, to be realistic the roll thermal fatigue degradation model has to incorporate this non uniform HTCroll-bite.
- Open Access
- 16 April 2012
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 25, 01063
Nozzle cooling of hot surfaces with various orientations
- 16 April 2012
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 25, 01063
Open AccessNozzle cooling of hot surfaces with various orientations
- 3 February 2012
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 504-506, 1043-1048
Analysis of Roll Gap Heat Transfers in Hot Steel Strip Rolling through Roll Temperature Sensors and Heat Transfer Models
This paper presents an analysis of roll bite heat transfers during hot steel strip rolling. Two types of temperature sensors (drilled sensor /slot sensor) implemented near roll surface and heat transfer models are used to identify in the roll bite interfacial heat flux, temperature and Heat Transfer Coefficient HTCroll-bite during pilot rolling tests. It is shown that: - the slot type sensor is much more efficient than the drilled type sensor to capture correctly fast roll temperature changes in the bite during hot rolling but life’s duration of the slot sensor is shorter. - average HTCroll-bite, identified with roll sensors temperature signals is within the range 15-26 kW/m2/K: the higher the strip reduction is, the higher the HTCroll-bite is. - scale thickness at strip surface tends to decrease heat transfers from strip to roll in the roll bite. - HTCroll-bite appears not uniform along the roll-strip contact, in contrast to usual assumptions made in existing models - Heat dissipated by friction at roll-strip interface and its partitioning through roll and strip respectively seems over-estimated in the existing thermal roll gap model [1]. Modeling of interfacial friction heat dissipation should be reviewed and verified. The above results show the interest of roll temperature sensors to determine accurately roll bite heat transfers and evaluate more precisely the corresponding roll thermal fatigue degradation.
- 3 February 2012
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 504-506, 1043-1048
Analysis of Roll Gap Heat Transfers in Hot Steel Strip Rolling through Roll Temperature Sensors and Heat Transfer Models
This paper presents an analysis of roll bite heat transfers during hot steel strip rolling. Two types of temperature sensors (drilled sensor /slot sensor) implemented near roll surface and heat transfer models are used to identify in the roll bite interfacial heat flux, temperature and Heat Transfer Coefficient HTCroll-bite during pilot rolling tests. It is shown that: - the slot type sensor is much more efficient than the drilled type sensor to capture correctly fast roll temperature changes in the bite during hot rolling but life’s duration of the slot sensor is shorter. - average HTCroll-bite, identified with roll sensors temperature signals is within the range 15-26 kW/m2/K: the higher the strip reduction is, the higher the HTCroll-bite is. - scale thickness at strip surface tends to decrease heat transfers from strip to roll in the roll bite. - HTCroll-bite appears not uniform along the roll-strip contact, in contrast to usual assumptions made in existing models - Heat dissipated by friction at roll-strip interface and its partitioning through roll and strip respectively seems over-estimated in the existing thermal roll gap model [1]. Modeling of interfacial friction heat dissipation should be reviewed and verified. The above results show the interest of roll temperature sensors to determine accurately roll bite heat transfers and evaluate more precisely the corresponding roll thermal fatigue degradation.
- 1 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 452-453, 959-963
Experimental Study of Interfacial Heat Flux and Surface Temperature by Inverse Analysis with Thermocouple (Fully Embedded) during Hot Steel Strip Rolling
- 1 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 452-453, 959-963
Experimental Study of Interfacial Heat Flux and Surface Temperature by Inverse Analysis with Thermocouple (Fully Embedded) during Hot Steel Strip Rolling
- 1 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 452-453, 959-963
Experimental Study of Interfacial Heat Flux and Surface Temperature by Inverse Analysis with Thermocouple (Fully Embedded) during Hot Steel Strip Rolling
Knowledge of temperature distribution in the roll is fundamental aspect in cold rolling. An inverse analytical method has been previously developed to determine interfacial heat flux and surface temperature by measuring the temperature with a thermocouple (fully embedded) at only one point inside the roll. On this basis some pilot mill tests have been performed. The temperature sensor, the calibration procedure and rolling tests at different strip rolling conditions (5%, 10%, 15% and 20%) are described. Results show a good agreement with well-known theoretical models. Moreover the CPU times of the method (around 0.05 s by cycle) enable an online control of the rolling process.
- 1 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 452-453, 959-963
Experimental Study of Interfacial Heat Flux and Surface Temperature by Inverse Analysis with Thermocouple (Fully Embedded) during Hot Steel Strip Rolling
Knowledge of temperature distribution in the roll is fundamental aspect in cold rolling. An inverse analytical method has been previously developed to determine interfacial heat flux and surface temperature by measuring the temperature with a thermocouple (fully embedded) at only one point inside the roll. On this basis some pilot mill tests have been performed. The temperature sensor, the calibration procedure and rolling tests at different strip rolling conditions (5%, 10%, 15% and 20%) are described. Results show a good agreement with well-known theoretical models. Moreover the CPU times of the method (around 0.05 s by cycle) enable an online control of the rolling process.