Erhan Tütüncü
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Erhan Tütüncü has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Boris Mizaikoff
Institute of Analytical and Bioanalytical Chemistry Ulm University Ulm Germany
9 shared publications Felicia Seichter
Institute of Analytical and Bioanalytical Chemistry, Ulm University, D-89081 Ulm, Germany
3 shared publicationsMarc Fischer
Nanoplus Nanosystems and Technologies GmbH , Oberer Kirschberg 4 , 97218 Gerbrunn , Germany
3 shared publicationsPeter Radermacher
Institute of Anesthesiologic Pathophysiology and Method Development , Ulm University Medical Center , Helmholtzstr. 8/1 , 89081 Ulm , Germany
3 shared publicationsUlrich Wachter
Institute of Anesthesiologic Pathophysiology and Method Development , Ulm University Medical Center , Helmholtzstr. 8/1 , 89081 Ulm , Germany
3 shared publicationsAndreas Wilk
Institute of Analytical and Bioanalytical Chemistry (IABC), Ulm University , Albert-Einstein-Allee 11, 89081 Ulm, Germany
2 shared publications
Latest Publications
- 18 December 2018
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 411 (9) , 1679-1686
Cascade laser sensing concepts for advanced breath diagnostics
With more than a thousand constituents at trace level concentrations, exhaled breath analysis (EBA) allows for non-invasive point-of-care (POC) disease diagnostics and metabolic status monitoring in or close to real-time. A number of biomarkers in breath may be used to not only identify diseases and disease progression but also to monitor therapeutic interventions. Although the relationship of selected breath components/biomarkers with certain disease pathologies is well established, diagnosing the exhaled breath composition remains an analytical and practical challenge due to the concentration levels of molecules of interest, i.e., low parts-per-billion (ppb) regime and below. Besides the analytical assessment of breath components via conventional methods such as gas chromatography coupled to mass spectrometry and related techniques, the application of cascade laser spectroscopy (CLS) is relatively new and exhibits several advantages when aiming for compact and user-friendly trace gas sensors with high molecular selectivity, the required sensitivity, and potentially reasonable instrumental costs. This trend article highlights the current status and potential of CLS in breath diagnostics with a focus on recent advancements in instrumentation and application along with future prospects and challenges.
- 18 December 2018
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 411 (9) , 1679-1686
Cascade laser sensing concepts for advanced breath diagnostics
With more than a thousand constituents at trace level concentrations, exhaled breath analysis (EBA) allows for non-invasive point-of-care (POC) disease diagnostics and metabolic status monitoring in or close to real-time. A number of biomarkers in breath may be used to not only identify diseases and disease progression but also to monitor therapeutic interventions. Although the relationship of selected breath components/biomarkers with certain disease pathologies is well established, diagnosing the exhaled breath composition remains an analytical and practical challenge due to the concentration levels of molecules of interest, i.e., low parts-per-billion (ppb) regime and below. Besides the analytical assessment of breath components via conventional methods such as gas chromatography coupled to mass spectrometry and related techniques, the application of cascade laser spectroscopy (CLS) is relatively new and exhibits several advantages when aiming for compact and user-friendly trace gas sensors with high molecular selectivity, the required sensitivity, and potentially reasonable instrumental costs. This trend article highlights the current status and potential of CLS in breath diagnostics with a focus on recent advancements in instrumentation and application along with future prospects and challenges.
- 12 September 2018
- Published by Wiley
- p. 1-19
Instrumentation and Applications of Cascade Laser Spectroscopy
- 12 September 2018
- Published by Wiley
- p. 1-19
Instrumentation and Applications of Cascade Laser Spectroscopy
- 3 August 2018
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 3 (9) , 1743-1749
Advanced Photonic Sensors Based on Interband Cascade Lasers for Real-Time Mouse Breath Analysis
A multiparameter gas sensor based on distributed feedback interband cascade lasers emitting at 4.35 μm and ultrafast electro-spun luminescence oxygen sensors has been developed for the quantification and continuous monitoring of 13CO2/12CO2 isotopic ratio changes and oxygen in exhaled mouse breath samples. Mid-infrared absorption spectra for quantitatively monitoring the enrichment of 13CO2 levels were recorded in a miniaturized dual-channel substrate-integrated hollow waveguide using balanced ratiometric detection, whereas luminescence quenching was used for synchronously detecting exhaled oxygen levels. Allan variance analysis verified a CO2 measurement precision of 1.6‰ during a 480 s integration time. Routine online monitoring of exhaled mouse breath was performed in 14 mechanically ventilated and instrumented mice and demonstrated the feasibility of online isotope-selective exhaled breath analysis within microliters of probed gas samples using the reported combined sensor platform.
- 3 August 2018
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 3 (9) , 1743-1749
Advanced Photonic Sensors Based on Interband Cascade Lasers for Real-Time Mouse Breath Analysis
A multiparameter gas sensor based on distributed feedback interband cascade lasers emitting at 4.35 μm and ultrafast electro-spun luminescence oxygen sensors has been developed for the quantification and continuous monitoring of 13CO2/12CO2 isotopic ratio changes and oxygen in exhaled mouse breath samples. Mid-infrared absorption spectra for quantitatively monitoring the enrichment of 13CO2 levels were recorded in a miniaturized dual-channel substrate-integrated hollow waveguide using balanced ratiometric detection, whereas luminescence quenching was used for synchronously detecting exhaled oxygen levels. Allan variance analysis verified a CO2 measurement precision of 1.6‰ during a 480 s integration time. Routine online monitoring of exhaled mouse breath was performed in 14 mechanically ventilated and instrumented mice and demonstrated the feasibility of online isotope-selective exhaled breath analysis within microliters of probed gas samples using the reported combined sensor platform.
- Open Access
- 28 May 2018
- Published by IOP Publishing in Journal of Breath Research
- Vol. 12 (3) , 036018
Online monitoring of carbon dioxide and oxygen in exhaled mouse breath via substrate-integrated hollow waveguide Fourier-transform infrared-luminescence spectroscopy
Exhaled breath offers monitoring bio markers, as well as diagnosing diseases and therapeutic interventions. In addition, vital functions may be non-invasively monitored online. Animal models are frequently used in research for determining novel therapeutic approaches and/or for investigating biological pathways. The exhaled carbon dioxide concentration, exhaled and inhaled oxygen concentration, and the subsequent respiratory quotient (RQ) offer insight into metabolic activity. One may adapt breath sampling systems and equipment designed for human applications to large animal studies. However, such adaptations are usually impossible for small animals due to their minuscule breath volume. Here, we present a system for the online monitoring of exhaled breath in a ‘mouse intensive care unit’ (MICU) based on a modified Fourier-transform infrared spectrometer equipped with a substrate-integrated hollow waveguide gas cell, and a luminescence-based oxygen flow-through sensor integrated into the respiratory equipment of the MICU. Thereby, per-minute resolution of O 2 consumption and CO 2 production was obtained, and the 95% confidence range of the determined RQ was ±0.04 or approximately ±5% of the nominal value. Changes in the RQ value caused by intervention in either the metabolic or respiratory system may therefore reliably be detected.
- 28 May 2018
- Published by IOP Publishing in Journal of Breath Research
- Vol. 12 (3) , 036018
Open AccessOnline monitoring of carbon dioxide and oxygen in exhaled mouse breath via substrate-integrated hollow waveguide Fourier-transform infrared-luminescence spectroscopy
Exhaled breath offers monitoring bio markers, as well as diagnosing diseases and therapeutic interventions. In addition, vital functions may be non-invasively monitored online. Animal models are frequently used in research for determining novel therapeutic approaches and/or for investigating biological pathways. The exhaled carbon dioxide concentration, exhaled and inhaled oxygen concentration, and the subsequent respiratory quotient (RQ) offer insight into metabolic activity. One may adapt breath sampling systems and equipment designed for human applications to large animal studies. However, such adaptations are usually impossible for small animals due to their minuscule breath volume. Here, we present a system for the online monitoring of exhaled breath in a ‘mouse intensive care unit’ (MICU) based on a modified Fourier-transform infrared spectrometer equipped with a substrate-integrated hollow waveguide gas cell, and a luminescence-based oxygen flow-through sensor integrated into the respiratory equipment of the MICU. Thereby, per-minute resolution of O 2 consumption and CO 2 production was obtained, and the 95% confidence range of the determined RQ was ±0.04 or approximately ±5% of the nominal value. Changes in the RQ value caused by intervention in either the metabolic or respiratory system may therefore reliably be detected.
- 13 November 2017
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 2 (11) , 1700-1705
polyHWG: 3D Printed Substrate-Integrated Hollow Waveguides for Mid-Infrared Gas Sensing
Gas analysis via mid-infrared (MIR) spectroscopic techniques has gained significance due to its inherent molecular selectivity and sensitivity probing pronounced vibrational, rotational, and roto-vibrational modes. In addition, MIR gas sensors are suitable for real-time monitoring in a wide variety of sensing scenarios. Our research team has recently introduced so-called substrate-integrated hollow waveguides (iHWGs) fabricated by precision milling, which have been demonstrated to be useful in online process monitoring, environmental sensing, and exhaled breath analysis especially if low sample volumes (i.e., few hundreds of microliters) are probed with rapid signal transients. A logical next step is to establish ultralightweight, potentially disposable, and low-cost substrate-integrated hollow waveguides, which may be readily customized and tailored to specific applications using 3D printing techniques. 3D printing provides access to an unprecedented variety of thermoplastic materials including biocompatible polylactides, readily etchable styrene copolymers, and magnetic or conductive materials. Thus, the properties of the waveguide may be adapted to suit its designated application, e.g., drone-mounted ultralightweight waveguides for environmental monitoring or biocompatible disposable sensor interfaces in medical/clinical applications.
- 13 November 2017
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 2 (11) , 1700-1705
polyHWG: 3D Printed Substrate-Integrated Hollow Waveguides for Mid-Infrared Gas Sensing
Gas analysis via mid-infrared (MIR) spectroscopic techniques has gained significance due to its inherent molecular selectivity and sensitivity probing pronounced vibrational, rotational, and roto-vibrational modes. In addition, MIR gas sensors are suitable for real-time monitoring in a wide variety of sensing scenarios. Our research team has recently introduced so-called substrate-integrated hollow waveguides (iHWGs) fabricated by precision milling, which have been demonstrated to be useful in online process monitoring, environmental sensing, and exhaled breath analysis especially if low sample volumes (i.e., few hundreds of microliters) are probed with rapid signal transients. A logical next step is to establish ultralightweight, potentially disposable, and low-cost substrate-integrated hollow waveguides, which may be readily customized and tailored to specific applications using 3D printing techniques. 3D printing provides access to an unprecedented variety of thermoplastic materials including biocompatible polylactides, readily etchable styrene copolymers, and magnetic or conductive materials. Thus, the properties of the waveguide may be adapted to suit its designated application, e.g., drone-mounted ultralightweight waveguides for environmental monitoring or biocompatible disposable sensor interfaces in medical/clinical applications.
- Open Access
- 19 September 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-13
Inhibiting P. fluorescens biofilms with fluoropolymer-embedded silver nanoparticles: an in-situ spectroscopic study
Surface colonization by microorganisms leads to the formation of biofilms, i.e. aggregates of bacteria embedded within a matrix of extracellular polymeric substance. This promotes adhesion to the surface and protects bacterial community, providing an antimicrobial-resistant environment. The inhibition of biofilm growth is a crucial issue for preventing bacterial infections. Inorganic nanoparticle/Teflon-like (CFx) composites deposited via ion beam sputtering demonstrated very efficient antimicrobial activity. In this study, we developed Ag-CFx thin films with tuneable metal loadings and exceptional in-plane morphological and chemical homogeneity. Ag-CFx antimicrobial activity was studied via mid-infrared attenuated total reflection spectroscopy utilizing specifically adapted multi-reflection waveguides. Biofilm was sampled by carefully depositing the Ag-CFx film on IR inactive regions of the waveguide. Real-time infrared spectroscopy was used to monitor Pseudomonas fluorescens biofilm growth inhibition induced by the bioactive silver ions released from the nanoantimicrobial coating. Few hours of Ag-CFx action were sufficient to affect significantly biofilm growth. These findings were corroborated by atomic force microscopy (AFM) studies on living bacteria exposed to the same nanoantimicrobial. Morphological analyses showed a severe bacterial stress, leading to membrane leakage/collapse or to extended cell lysis as a function of incubation time.
- 19 September 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-13
Open AccessInhibiting P. fluorescens biofilms with fluoropolymer-embedded silver nanoparticles: an in-situ spectroscopic study
Surface colonization by microorganisms leads to the formation of biofilms, i.e. aggregates of bacteria embedded within a matrix of extracellular polymeric substance. This promotes adhesion to the surface and protects bacterial community, providing an antimicrobial-resistant environment. The inhibition of biofilm growth is a crucial issue for preventing bacterial infections. Inorganic nanoparticle/Teflon-like (CFx) composites deposited via ion beam sputtering demonstrated very efficient antimicrobial activity. In this study, we developed Ag-CFx thin films with tuneable metal loadings and exceptional in-plane morphological and chemical homogeneity. Ag-CFx antimicrobial activity was studied via mid-infrared attenuated total reflection spectroscopy utilizing specifically adapted multi-reflection waveguides. Biofilm was sampled by carefully depositing the Ag-CFx film on IR inactive regions of the waveguide. Real-time infrared spectroscopy was used to monitor Pseudomonas fluorescens biofilm growth inhibition induced by the bioactive silver ions released from the nanoantimicrobial coating. Few hours of Ag-CFx action were sufficient to affect significantly biofilm growth. These findings were corroborated by atomic force microscopy (AFM) studies on living bacteria exposed to the same nanoantimicrobial. Morphological analyses showed a severe bacterial stress, leading to membrane leakage/collapse or to extended cell lysis as a function of incubation time.
- Open Access
- 22 August 2017
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 2 (9) , 1287-1293
Fiber-Coupled Substrate-Integrated Hollow Waveguides: An Innovative Approach to Mid-infrared Remote Gas Sensors
In this study, an innovative approach based on fiberoptically coupled substrate-integrated hollow waveguide (iHWG) gas cells for the analysis of low sample volumes suitable for remote broad- and narrow-band mid-infrared (MIR; 2.5–20 μm) sensing applications is reported. The feasibility of remotely addressing iHWG gas cells, configured in a double-pass geometry via a reflector, by direct coupling to a 7-around-1 mid-infrared fiber bundle is demonstrated, facilitating low-level hydrocarbon gas analysis. For comparison studies, two iHWGs with substrate dimensions of 50 × 50 × 12 mm (L × W × H) and geometric channel lengths of 138 and 58.5 mm, serving as miniature light-guiding gas cells, were fiber-coupled to a Fourier transform infrared spectrometer enabling broadband MIR sensing. In addition to the fundamental feasibility of this concept, the achievable sensitivity toward several gaseous hydrocarbons and the reproducibility of assembling the fiber-iHWG interface were investigated.
- 22 August 2017
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 2 (9) , 1287-1293
Open AccessFiber-Coupled Substrate-Integrated Hollow Waveguides: An Innovative Approach to Mid-infrared Remote Gas Sensors
In this study, an innovative approach based on fiberoptically coupled substrate-integrated hollow waveguide (iHWG) gas cells for the analysis of low sample volumes suitable for remote broad- and narrow-band mid-infrared (MIR; 2.5–20 μm) sensing applications is reported. The feasibility of remotely addressing iHWG gas cells, configured in a double-pass geometry via a reflector, by direct coupling to a 7-around-1 mid-infrared fiber bundle is demonstrated, facilitating low-level hydrocarbon gas analysis. For comparison studies, two iHWGs with substrate dimensions of 50 × 50 × 12 mm (L × W × H) and geometric channel lengths of 138 and 58.5 mm, serving as miniature light-guiding gas cells, were fiber-coupled to a Fourier transform infrared spectrometer enabling broadband MIR sensing. In addition to the fundamental feasibility of this concept, the achievable sensitivity toward several gaseous hydrocarbons and the reproducibility of assembling the fiber-iHWG interface were investigated.
- Open Access
- 8 August 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (22) , 6202-6207
Advanced gas sensors based on substrate-integrated hollow waveguides and dual-color ring quantum cascade lasers
This study shows the first combination of a ring-shaped vertically emitting quantum cascade laser (riQCL) providing two distinct emission wavelengths combined with a substrate-integrated hollow waveguide (iHWG). This ultra-compact riQCL-iHWG gas sensing device enables the simultaneous detection of two vapor phase species – here, furan and 2-methoxyethanol – providing distinctive absorption features at the emission wavelengths of the riQCL (i.e., 1144 and 1170 cm−1). Hence, multianalyte gas sensing via a unique mid-infrared (MIR) sensor concept is demonstrated.
- 8 August 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (22) , 6202-6207
Open AccessAdvanced gas sensors based on substrate-integrated hollow waveguides and dual-color ring quantum cascade lasers
This study shows the first combination of a ring-shaped vertically emitting quantum cascade laser (riQCL) providing two distinct emission wavelengths combined with a substrate-integrated hollow waveguide (iHWG). This ultra-compact riQCL-iHWG gas sensing device enables the simultaneous detection of two vapor phase species – here, furan and 2-methoxyethanol – providing distinctive absorption features at the emission wavelengths of the riQCL (i.e., 1144 and 1170 cm−1). Hence, multianalyte gas sensing via a unique mid-infrared (MIR) sensor concept is demonstrated.
- 9 June 2016
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 1 (7) , 847-851
iHWG-ICL: Methane Sensing with Substrate-Integrated Hollow Waveguides Directly Coupled to Interband Cascade Lasers
- 9 June 2016
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 1 (7) , 847-851
iHWG-ICL: Methane Sensing with Substrate-Integrated Hollow Waveguides Directly Coupled to Interband Cascade Lasers
- 5 May 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (14) , 4432-4437
Sensing hydrocarbons with interband cascade lasers and substrate-integrated hollow waveguides
Tunable diode laser absorption spectroscopy (TDLAS) is an excellent analytical technique for gas sensing applications. In situ sensing of relevant hydrocarbon gases is of substantial interest for a variety of in-field scenarios including environmental monitoring and process analysis, ideally providing accurate, molecule specific, and rapid information with minimal sampling requirements. Substrate-integrated hollow waveguides (iHWGs) have demonstrated superior properties for gas sensing applications owing to minimal sample volumes required while simultaneously serving as efficient photon conduits. Interband cascade lasers (ICLs) are recently emerging as mid-infrared light sources operating at room temperature, with low power consumption, and providing excellent potential for integration. Thereby, portable and handheld mid-infrared sensing devices are facilitated. Methane (CH4) is among the most frequently occurring, and thus, highly relevant hydrocarbons requiring in situ emission monitoring by taking advantage of its distinct molecular absorption around 3 μm. Here, an efficient combination of iHWGs with ICLs is presented providing a methane sensor calibrated in the range of 100 to 2000 ppmv with a limit of detection at 38 ppmv at the current stage of development. Furthermore, a measurement precision of 0.62 ppbv during only 1 s of averaging time has been demonstrated, thereby rendering this sensor concept useful for in-line and on-site emission monitoring and process control applications.
- 5 May 2016
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 141 (14) , 4432-4437
Sensing hydrocarbons with interband cascade lasers and substrate-integrated hollow waveguides
Tunable diode laser absorption spectroscopy (TDLAS) is an excellent analytical technique for gas sensing applications. In situ sensing of relevant hydrocarbon gases is of substantial interest for a variety of in-field scenarios including environmental monitoring and process analysis, ideally providing accurate, molecule specific, and rapid information with minimal sampling requirements. Substrate-integrated hollow waveguides (iHWGs) have demonstrated superior properties for gas sensing applications owing to minimal sample volumes required while simultaneously serving as efficient photon conduits. Interband cascade lasers (ICLs) are recently emerging as mid-infrared light sources operating at room temperature, with low power consumption, and providing excellent potential for integration. Thereby, portable and handheld mid-infrared sensing devices are facilitated. Methane (CH4) is among the most frequently occurring, and thus, highly relevant hydrocarbons requiring in situ emission monitoring by taking advantage of its distinct molecular absorption around 3 μm. Here, an efficient combination of iHWGs with ICLs is presented providing a methane sensor calibrated in the range of 100 to 2000 ppmv with a limit of detection at 38 ppmv at the current stage of development. Furthermore, a measurement precision of 0.62 ppbv during only 1 s of averaging time has been demonstrated, thereby rendering this sensor concept useful for in-line and on-site emission monitoring and process control applications.