Omid Rajabi Shishvan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Omid Rajabi Shishvan has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Abdelwahab
Department of Electrical and Computer Engineering, University at Albany, State University of New York, USA
3 shared publications - Gary J. Saulnier
Department of Electrical and Computer Engineering, University at Albany, State University of New York, Albany, NY, USA
3 shared publications - Tolga Soyata
Department of Electrical and Computer Engineering, University at Albany, State University of New York, Albany, NY, USA
3 shared publications David Isaacson
Rensselaer Polytechnic Institute, Troy, USA
2 shared publications- Jennifer L. Mueller
Department of Mathematics and School of Biomedical Engineering, Colorado State University, USA
2 shared publications - Jonathan C. Newell
Department of Biomedical Engineering, Rensselaer Polytechnic Institute, USA
2 shared publications
Latest Publications
- 24 February 2026
- Published by Springer Nature in Journal of Perinatology
- p. 1-8
Electrical impedance tomography reveals ventilation and perfusion heterogeneity in infants with bronchopulmonary dysplasia
Objective Preterm infants have pulmonary ventilation and perfusion abnormalities, yet few imaging modalities can inform clinicians about this ventilation/perfusion (V/Q) relationship. Electrical impedance tomography (EIT) is an imaging technique with V/Q imaging capabilities that has not been well described in infants with BPD. Study design EIT was performed every 4 weeks in preterm infants for a maximum of 5 visits per infant. Term infants with healthy lungs had one EIT imaging visit as controls. Results Data were collected from a total of 51 EIT visits. Novel V/Q maps were generated from each visit. Ventilation heterogeneity (measured by the global inhomogeneity index) and V/Q heterogeneity (measured by coefficient of variation of V/Q maps) were significantly higher in preterm infants at the visit closest to 36 weeks post-menstrual age than controls (p = 0.002 and p = 0.039, respectively). Conclusions: Pulmonary ventilation, perfusion, and V/Q relationship can be quantified by EIT, and may be indicators of chronic lung disease.
- 24 February 2026
- Published by Springer Nature in Journal of Perinatology
- p. 1-8
Electrical impedance tomography reveals ventilation and perfusion heterogeneity in infants with bronchopulmonary dysplasia
Objective Preterm infants have pulmonary ventilation and perfusion abnormalities, yet few imaging modalities can inform clinicians about this ventilation/perfusion (V/Q) relationship. Electrical impedance tomography (EIT) is an imaging technique with V/Q imaging capabilities that has not been well described in infants with BPD. Study design EIT was performed every 4 weeks in preterm infants for a maximum of 5 visits per infant. Term infants with healthy lungs had one EIT imaging visit as controls. Results Data were collected from a total of 51 EIT visits. Novel V/Q maps were generated from each visit. Ventilation heterogeneity (measured by the global inhomogeneity index) and V/Q heterogeneity (measured by coefficient of variation of V/Q maps) were significantly higher in preterm infants at the visit closest to 36 weeks post-menstrual age than controls (p = 0.002 and p = 0.039, respectively). Conclusions: Pulmonary ventilation, perfusion, and V/Q relationship can be quantified by EIT, and may be indicators of chronic lung disease.
- 2 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1498-1507
Simultaneous Acquisition of EIT and ECG Signals on Active EIT Electrodes
Objective: This paper introduces a new method of simultaneous acquisition of electrocardiogram (ECG) signals and electrical impedance tomography (EIT) measurements on active electrodes, i.e. electrodes that are applying current, in an EIT system. Methods: Howland noise reduction followed by an integrate-and-dump filter and adaptive filtering are used to extract the ECG signal without loss of amplitude. Results: Results of simultaneous ECG signals and EIT reconstructions on human subjects are shown. It is also demonstrated that the recovered ECG waveforms from 32 electrodes can be used to reconstruct the heart current source vectors during a cardiac cycle, yielding an approximate solution to the inverse problem of electrocardiography. Significance: Acquiring ECG signals from all electrodes attached to the body simultaneously with EIT data acquisition eliminates the need for a separate system to collect ECG signals. Time-aligned ECG signals are helpful in interpreting pulsatile perfusion images by providing exact timing of each image in relation to the cardiac cycle. Additionally, collecting ECG signals from many or all of the EIT electrodes enables reconstruction of the heart's moving dipole moment at the same time as the EIT images.
- 2 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1498-1507
Simultaneous Acquisition of EIT and ECG Signals on Active EIT Electrodes
Objective: This paper introduces a new method of simultaneous acquisition of electrocardiogram (ECG) signals and electrical impedance tomography (EIT) measurements on active electrodes, i.e. electrodes that are applying current, in an EIT system. Methods: Howland noise reduction followed by an integrate-and-dump filter and adaptive filtering are used to extract the ECG signal without loss of amplitude. Results: Results of simultaneous ECG signals and EIT reconstructions on human subjects are shown. It is also demonstrated that the recovered ECG waveforms from 32 electrodes can be used to reconstruct the heart current source vectors during a cardiac cycle, yielding an approximate solution to the inverse problem of electrocardiography. Significance: Acquiring ECG signals from all electrodes attached to the body simultaneously with EIT data acquisition eliminates the need for a separate system to collect ECG signals. Time-aligned ECG signals are helpful in interpreting pulsatile perfusion images by providing exact timing of each image in relation to the cardiac cycle. Additionally, collecting ECG signals from many or all of the EIT electrodes enables reconstruction of the heart's moving dipole moment at the same time as the EIT images.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Minimizing Coaxial Cable Effects on EIT Measurements using the Two-port Network Parameters
The impact of coaxial cables on EIT system performance has always been a concern. The usual goal is to find the best approach to cancel out the effect of the shunt impedance of the cable as it has a high impact on the system performance. In contrast, the impact of series elements is usually neglected. In this paper, a new approach based on precise modeling of the cable and the current source using two-port parameters is described, verified, and evaluated. This approach compensates for both the series and shunt elements on the path from the source to the load, providing a compensated load current and voltage. Experimental and simulation results for frequencies up to 1 MHz are provided, showing a comparison between the reconstructed load values using both compensated and uncompensated load voltage for a 1m RG-174 coaxial cable with a grounded shield. The experimental results show promising performance in minimizing the series cable effects and achieving a low relative error of 0.1% in load reconstruction.
- 19 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Minimizing Coaxial Cable Effects on EIT Measurements using the Two-port Network Parameters
The impact of coaxial cables on EIT system performance has always been a concern. The usual goal is to find the best approach to cancel out the effect of the shunt impedance of the cable as it has a high impact on the system performance. In contrast, the impact of series elements is usually neglected. In this paper, a new approach based on precise modeling of the cable and the current source using two-port parameters is described, verified, and evaluated. This approach compensates for both the series and shunt elements on the path from the source to the load, providing a compensated load current and voltage. Experimental and simulation results for frequencies up to 1 MHz are provided, showing a comparison between the reconstructed load values using both compensated and uncompensated load voltage for a 1m RG-174 coaxial cable with a grounded shield. The experimental results show promising performance in minimizing the series cable effects and achieving a low relative error of 0.1% in load reconstruction.
- 17 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (1) , 227-236
ACT5 Electrical Impedance Tomography System
Objective: This article introduces the Adaptive Current Tomograph 5 (ACT5) Electrical Impedance Tomography (EIT) system. ACT5 is a 32 electrode applied-current multiple-source EIT system that can display real-time images of conductivity and susceptivity at 27 frames per second. The adaptive current sources in ACT5 can apply fully programmable current patterns with frequencies varying from 5 kHz to 500 kHz. The system also displays real-time ECG readings during the EIT imaging process. Methods: The hardware and software design and specifications are presented, including the current source design, FPGA hardware, safety features, calibration, and shunt impedance measurement. Results: Images of conductivity and susceptivity are presented from ACT5 data collected on tank phantoms and a human subject illustrating the system's ability to provide real-time images of pulsatile perfusion and ECG traces. Significance: The portability, high signal-to-noise ratio, and flexibility of applied currents over a wide range of frequencies enable this instrument to be used to obtain useful human subject data with relative clinical ease.
- 17 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (1) , 227-236
ACT5 Electrical Impedance Tomography System
Objective: This article introduces the Adaptive Current Tomograph 5 (ACT5) Electrical Impedance Tomography (EIT) system. ACT5 is a 32 electrode applied-current multiple-source EIT system that can display real-time images of conductivity and susceptivity at 27 frames per second. The adaptive current sources in ACT5 can apply fully programmable current patterns with frequencies varying from 5 kHz to 500 kHz. The system also displays real-time ECG readings during the EIT imaging process. Methods: The hardware and software design and specifications are presented, including the current source design, FPGA hardware, safety features, calibration, and shunt impedance measurement. Results: Images of conductivity and susceptivity are presented from ACT5 data collected on tank phantoms and a human subject illustrating the system's ability to provide real-time images of pulsatile perfusion and ECG traces. Significance: The portability, high signal-to-noise ratio, and flexibility of applied currents over a wide range of frequencies enable this instrument to be used to obtain useful human subject data with relative clinical ease.
- 6 December 2022
- Published by IOP Publishing in Physiological Measurement
- Vol. 43 (12) , 124001
Fast absolute 3D CGO-based electrical impedance tomography on experimental tank data
Objective. To present the first 3D CGO-based absolute EIT reconstructions from experimental tank data. Approach. CGO-based methods for absolute EIT imaging are compared to traditional TV regularized non-linear least squares reconstruction methods. Additional robustness testing is performed by considering incorrect modeling of domain shape. Main Results. The CGO-based methods are fast, and show strong robustness to incorrect domain modeling comparable to classic difference EIT imaging and fewer boundary artefacts than the TV regularized non-linear least squares reference reconstructions. Significance. This work is the first to demonstrate fully 3D CGO-based absolute EIT reconstruction on experimental data and also compares to TV-regularized absolute reconstruction. The speed (1–5 s) and quality of the reconstructions is encouraging for future work in absolute EIT.
- 6 December 2022
- Published by IOP Publishing in Physiological Measurement
- Vol. 43 (12) , 124001
Fast absolute 3D CGO-based electrical impedance tomography on experimental tank data
Objective. To present the first 3D CGO-based absolute EIT reconstructions from experimental tank data. Approach. CGO-based methods for absolute EIT imaging are compared to traditional TV regularized non-linear least squares reconstruction methods. Additional robustness testing is performed by considering incorrect modeling of domain shape. Main Results. The CGO-based methods are fast, and show strong robustness to incorrect domain modeling comparable to classic difference EIT imaging and fewer boundary artefacts than the TV regularized non-linear least squares reference reconstructions. Significance. This work is the first to demonstrate fully 3D CGO-based absolute EIT reconstruction on experimental data and also compares to TV-regularized absolute reconstruction. The speed (1–5 s) and quality of the reconstructions is encouraging for future work in absolute EIT.
- Top Cited Papers
- 9 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 7 (1) , 53-71
A Survey of Healthcare Internet of Things (HIoT): A Clinical Perspective
In combination with current sociological trends, the maturing development of Internet of Things devices is projected to revolutionize healthcare. A network of body-worn sensors, each with a unique ID, can collect health data, that is, orders-of-magnitude richer than what is available today from sporadic observations in clinical/hospital environments. When databased, analyzed, and compared against information from other individuals using data analytics, Healthcare Internet of Things data enables the personalization and modernization of care with radical improvements in outcomes and reductions in cost. In this article, we survey the existing and emerging technologies that can enable this vision for the future of healthcare, particularly, in the clinical practice of healthcare. Three main technology areas underlie the development of this field: 1) sensing, where there is an increased drive for miniaturization and power efficiency; 2) communications, where the enabling factors are ubiquitous connectivity, standardized protocols, and the wide availability of cloud infrastructure; and 3) data analytics and inference, where the availability of large amounts of data and computational resources is revolutionizing algorithms for individualizing inference and actions in health management. Throughout this article, we use a case study to concretely illustrate the impact of these trends. We conclude this article with a discussion of the emerging directions, open issues, and challenges.
- 9 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 7 (1) , 53-71
Top Cited PapersA Survey of Healthcare Internet of Things (HIoT): A Clinical Perspective
In combination with current sociological trends, the maturing development of Internet of Things devices is projected to revolutionize healthcare. A network of body-worn sensors, each with a unique ID, can collect health data, that is, orders-of-magnitude richer than what is available today from sporadic observations in clinical/hospital environments. When databased, analyzed, and compared against information from other individuals using data analytics, Healthcare Internet of Things data enables the personalization and modernization of care with radical improvements in outcomes and reductions in cost. In this article, we survey the existing and emerging technologies that can enable this vision for the future of healthcare, particularly, in the clinical practice of healthcare. Three main technology areas underlie the development of this field: 1) sensing, where there is an increased drive for miniaturization and power efficiency; 2) communications, where the enabling factors are ubiquitous connectivity, standardized protocols, and the wide availability of cloud infrastructure; and 3) data analytics and inference, where the availability of large amounts of data and computational resources is revolutionizing algorithms for individualizing inference and actions in health management. Throughout this article, we use a case study to concretely illustrate the impact of these trends. We conclude this article with a discussion of the emerging directions, open issues, and challenges.
- 1 March 2019
- Published by Elsevier in Journal of Electrocardiology
- Vol. 53, 89-94
Home use of a compact, 12‑lead ECG recording system for newborns
- 1 March 2019
- Published by Elsevier in Journal of Electrocardiology
- Vol. 53, 89-94
Home use of a compact, 12‑lead ECG recording system for newborns
- Open Access
- 20 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 6, 46419-46494
Machine Intelligence in Healthcare and Medical Cyber Physical Systems: A Survey
Today, the US healthcare industry alone can save $300 B per year by using machine intelligence to analyze a rich set of existing medical data; results from these analyses can lead to breakthroughs such as more accurate medical diagnoses, discovery of new cures for diseases, and cost savings in the patient admission process at healthcare organizations. Because healthcare applications intrinsically imply a vast amount of data, the execution of any algorithm on medical data is computationally intensive. Significant advancements made in computational power in the past decade have provided the opportunity for many researchers to successfully implement various machine intelligence-based healthcare applications, which didn't run efficiently on earlier computational platforms. In this paper, we provide a survey of machine intelligence algorithms within the context of healthcare applications; our survey includes a comprehensive list of the most commonly used computational models and algorithms. We view the application of these algorithms in multiple steps, namely, data acquisition, feature extraction, and aggregation, modeling, algorithm training, and algorithm execution and provide details-as well as representative case studies-for each step. We provide a set of metrics that are used to evaluate modeling and algorithmic performance, which facilitate the comparison of the presented models and algorithms. Medical cyber-physical systems are presented as an emerging application case study of machine intelligence in healthcare. We conclude our paper by providing a list of opportunities and challenges for incorporating machine intelligence in healthcare applications and provide an extensive list of tools and databases to help other researchers.
- 20 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 6, 46419-46494
Open AccessMachine Intelligence in Healthcare and Medical Cyber Physical Systems: A Survey
Today, the US healthcare industry alone can save $300 B per year by using machine intelligence to analyze a rich set of existing medical data; results from these analyses can lead to breakthroughs such as more accurate medical diagnoses, discovery of new cures for diseases, and cost savings in the patient admission process at healthcare organizations. Because healthcare applications intrinsically imply a vast amount of data, the execution of any algorithm on medical data is computationally intensive. Significant advancements made in computational power in the past decade have provided the opportunity for many researchers to successfully implement various machine intelligence-based healthcare applications, which didn't run efficiently on earlier computational platforms. In this paper, we provide a survey of machine intelligence algorithms within the context of healthcare applications; our survey includes a comprehensive list of the most commonly used computational models and algorithms. We view the application of these algorithms in multiple steps, namely, data acquisition, feature extraction, and aggregation, modeling, algorithm training, and algorithm execution and provide details-as well as representative case studies-for each step. We provide a set of metrics that are used to evaluate modeling and algorithmic performance, which facilitate the comparison of the presented models and algorithms. Medical cyber-physical systems are presented as an emerging application case study of machine intelligence in healthcare. We conclude our paper by providing a list of opportunities and challenges for incorporating machine intelligence in healthcare applications and provide an extensive list of tools and databases to help other researchers.