Kaushik Basu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kaushik Basu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Anirban Pal
EE, Indian Institute of science, Bangalore, karnataka 560012, bangalore, karnataka India 560012
6 shared publications - Sayan Paul
Department of Electrical Engineering, Indian Institute of Science, Bangalore, India
6 shared publications - Shamibrota Kishore Roy
Department of Electrical Engineering, Indian Institute of Science, Bangalore, India
6 shared publications - Harisyam P. V.
Department of Electrical Engineering, Indian Institute of Science, Bangalore, India
4 shared publications - Surjakanta Mazumder
Department of Electrical Engineering, Indian Institute of Science, Bangalore, India
3 shared publications - Manish Mandal
Department of Electrical Engineering, Indian Institute of Science, Bangalore, India
2 shared publications
Latest Publications
- 18 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (5) , 1
Single Stage Three Phase Module and Modulation with Current stress Minimisation for Solid State Transformer based Fast Charging Stations
Direct integration with a medium-voltage AC (MVAC) grid is crucial for DC fast charging stations. Conventional solutions rely on step-down line-frequency transformers (LFTs) followed by low-voltage AC-DC and isolated DC-DC converters. However, LFTs’ size and weight increase the system footprint, reduce power density, and necessitate outdoor medium-voltage substations. One of the promising approaches that replaces the LFT with a high-frequency transformer that employs a number of isolated single-phase LVAC to LVDC converters in an input-series output-parallel (ISOP) combination. Single-stage LVAC-DC modules are preferred as they do not require large DC capacitors to absorb second harmonic power. The combination of DC side bridges to reduce the component count in some solutions leads to restricted freedom in modulation, higher current stress, only unidirectional-power-flow capability, or hard-switched operation. In this work, a three-phase bridge leg is introduced with a delta-connected DC side winding of the high-frequency transformers for a three-phase module. A DAB-derived novel optimal triple-phase shift modulation strategy is proposed that ensures bidirectional power flow, zero voltage switching over a wide range of line cycle, high quality power factor corrected input current without low frequency harmonics, and a significant reduction in current stress compared to the existing DAB-based solution. The paper details the converter’s design for the proposed modulation strategy and provides a comparative analysis. Experimental validation using a three-phase module demonstrates the effectiveness of the proposed approach with high efficiency (96.1%) and power quality (THD = 4.3%).
- 18 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (5) , 1
Single Stage Three Phase Module and Modulation with Current stress Minimisation for Solid State Transformer based Fast Charging Stations
Direct integration with a medium-voltage AC (MVAC) grid is crucial for DC fast charging stations. Conventional solutions rely on step-down line-frequency transformers (LFTs) followed by low-voltage AC-DC and isolated DC-DC converters. However, LFTs’ size and weight increase the system footprint, reduce power density, and necessitate outdoor medium-voltage substations. One of the promising approaches that replaces the LFT with a high-frequency transformer that employs a number of isolated single-phase LVAC to LVDC converters in an input-series output-parallel (ISOP) combination. Single-stage LVAC-DC modules are preferred as they do not require large DC capacitors to absorb second harmonic power. The combination of DC side bridges to reduce the component count in some solutions leads to restricted freedom in modulation, higher current stress, only unidirectional-power-flow capability, or hard-switched operation. In this work, a three-phase bridge leg is introduced with a delta-connected DC side winding of the high-frequency transformers for a three-phase module. A DAB-derived novel optimal triple-phase shift modulation strategy is proposed that ensures bidirectional power flow, zero voltage switching over a wide range of line cycle, high quality power factor corrected input current without low frequency harmonics, and a significant reduction in current stress compared to the existing DAB-based solution. The paper details the converter’s design for the proposed modulation strategy and provides a comparative analysis. Experimental validation using a three-phase module demonstrates the effectiveness of the proposed approach with high efficiency (96.1%) and power quality (THD = 4.3%).
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-15
Single Stage Soft Switched Medium Voltage AC to DC Converter With Reduced Current Stress
Integration with medium-voltage AC (MVAC) is essential for grid-integrated high-power DC applications. Single-phase single-stage AC to DC converters with high-frequency isolation are connected in an input series, output parallel configuration to realise an MVAC to DC converter that replaces line-frequency transformer-based solutions. Device count is reduced in such solutions by combining the bridges on the DC side, which brings additional challenges, such as unidirectional power flow, hard-switched operation, and higher current stress. This paper is based on a modular single-stage converter for direct MVAC-to-LVDC conversion with a combination of bridges on the DC side, overcoming these challenges. The four-leg structure on the DC side bridge with the proposed Dual Active Bridge (DAB) based Triple Phase Shift (TPS) modulation, reduces high-frequency current stress and achieves soft switching for the entire line cycle, thereby improving efficiency. The paper outlines the systematic design process for an 11 kV 400 kW system, including transformer turns ratio and series inductor to minimise the high-frequency current stress. Experimental results for a laboratory-scale 5 kW SiC-based prototype are provided with an efficiency of 96.3% and THD of 2.8% in AC side current to validate the proposed solution.
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-15
Single Stage Soft Switched Medium Voltage AC to DC Converter With Reduced Current Stress
Integration with medium-voltage AC (MVAC) is essential for grid-integrated high-power DC applications. Single-phase single-stage AC to DC converters with high-frequency isolation are connected in an input series, output parallel configuration to realise an MVAC to DC converter that replaces line-frequency transformer-based solutions. Device count is reduced in such solutions by combining the bridges on the DC side, which brings additional challenges, such as unidirectional power flow, hard-switched operation, and higher current stress. This paper is based on a modular single-stage converter for direct MVAC-to-LVDC conversion with a combination of bridges on the DC side, overcoming these challenges. The four-leg structure on the DC side bridge with the proposed Dual Active Bridge (DAB) based Triple Phase Shift (TPS) modulation, reduces high-frequency current stress and achieves soft switching for the entire line cycle, thereby improving efficiency. The paper outlines the systematic design process for an 11 kV 400 kW system, including transformer turns ratio and series inductor to minimise the high-frequency current stress. Experimental results for a laboratory-scale 5 kW SiC-based prototype are provided with an efficiency of 96.3% and THD of 2.8% in AC side current to validate the proposed solution.
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (1) , 16-28
Medium Voltage AC to Isolated Multiport DC Converter for Electric Vehicle Fast-Charging Stations
The dc fast charging stations operate at megawatt-scale power levels, drawing energy from the medium voltage ac (MVAC) grid to reduce transmission losses. It also requires local energy storage and the capability for renewable integration to reduce the load on the grid. Conventional solutions use a bulky line frequency transformer (LFT) to step down MVAC to low voltage ac (LVAC), followed by multiple ac–dc and isolated dc–dc converters, leading to lower efficiency especially during power flow between local storage and electric vehicles. Existing multiport MVAC-to-LVDC converters often rely on modular multilevel converters (MMCs), which has higher component count, or cascaded H-bridge (CHB) solutions with additional battery storage and additional bridges for power exchange. This article proposes a novel CHB-based multiport topology that eliminates the need for additional battery storage, additional semiconductor devices, and additional MV-insulated transformer winding compared to an MVAC to single port LVDC converter. The proposed modulation and control strategy ensures the independent operation of each LVDC port, and unity power factor (UPF) operation at the grid interface. A step-by-step design for an 11 kV two-port converter is presented, and experimental validation is performed using a 1.2 kW laboratory-scale prototype with an efficiency of 95.3% at rated load.
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (1) , 16-28
Medium Voltage AC to Isolated Multiport DC Converter for Electric Vehicle Fast-Charging Stations
The dc fast charging stations operate at megawatt-scale power levels, drawing energy from the medium voltage ac (MVAC) grid to reduce transmission losses. It also requires local energy storage and the capability for renewable integration to reduce the load on the grid. Conventional solutions use a bulky line frequency transformer (LFT) to step down MVAC to low voltage ac (LVAC), followed by multiple ac–dc and isolated dc–dc converters, leading to lower efficiency especially during power flow between local storage and electric vehicles. Existing multiport MVAC-to-LVDC converters often rely on modular multilevel converters (MMCs), which has higher component count, or cascaded H-bridge (CHB) solutions with additional battery storage and additional bridges for power exchange. This article proposes a novel CHB-based multiport topology that eliminates the need for additional battery storage, additional semiconductor devices, and additional MV-insulated transformer winding compared to an MVAC to single port LVDC converter. The proposed modulation and control strategy ensures the independent operation of each LVDC port, and unity power factor (UPF) operation at the grid interface. A step-by-step design for an 11 kV two-port converter is presented, and experimental validation is performed using a 1.2 kW laboratory-scale prototype with an efficiency of 95.3% at rated load.
- 19 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 2750-2767
A Two-Loop Feedback Control Strategy for Neutral Point Voltage Balancing of Three-Level Converter and Vienna Rectifier With a Carrier-Based Implementation
Neutral point voltage unbalancing is a critical issue in neutral-point-clamped three-level converters (TLCs) and Vienna rectifiers (VRs), where the voltages of two series-connected capacitors across the DC link become unequal. This imbalance leads to line current distortion, increased device stress, and potential failure. The primary cause is the non-zero average neutral point current, which depends on the modulation strategy. An effective voltage balancing strategy must dynamically maintain half of the total DC-bus voltage across each capacitor while minimizing low-frequency voltage pulsations. The distribution of dwell time among space-vector’s redundant switching states influences the neutral point current. Existing literature leverages this distribution factor for voltage balancing, but the associated plant model is nonlinear. The small-signal linearized model varies significantly across operating conditions, making compensator design challenging. Additionally, the conventional practice of maintaining the balancing loop bandwidth equal to that of the outer DC-bus control in the rectifier limits the effectiveness of this approach in mitigating triplen-harmonic voltage pulsations. This paper proposes an alternative control strategy that transforms the plant into a linear, exact, and large-signal valid system, simplifying compensator design. The balancing action is structured into a two-loop architecture: the DC offset correction operates at the same speed as the outer DC-bus control loop, while a faster loop mitigates third-harmonic voltage pulsations. Furthermore, a carrier-comparison-based implementation incorporating the proposed control is introduced. The effectiveness of the control strategy and its implementation is validated through simulations and experimental results on two hardware prototypes—one for TLC and another for VR.
- 19 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (2) , 2750-2767
A Two-Loop Feedback Control Strategy for Neutral Point Voltage Balancing of Three-Level Converter and Vienna Rectifier With a Carrier-Based Implementation
Neutral point voltage unbalancing is a critical issue in neutral-point-clamped three-level converters (TLCs) and Vienna rectifiers (VRs), where the voltages of two series-connected capacitors across the DC link become unequal. This imbalance leads to line current distortion, increased device stress, and potential failure. The primary cause is the non-zero average neutral point current, which depends on the modulation strategy. An effective voltage balancing strategy must dynamically maintain half of the total DC-bus voltage across each capacitor while minimizing low-frequency voltage pulsations. The distribution of dwell time among space-vector’s redundant switching states influences the neutral point current. Existing literature leverages this distribution factor for voltage balancing, but the associated plant model is nonlinear. The small-signal linearized model varies significantly across operating conditions, making compensator design challenging. Additionally, the conventional practice of maintaining the balancing loop bandwidth equal to that of the outer DC-bus control in the rectifier limits the effectiveness of this approach in mitigating triplen-harmonic voltage pulsations. This paper proposes an alternative control strategy that transforms the plant into a linear, exact, and large-signal valid system, simplifying compensator design. The balancing action is structured into a two-loop architecture: the DC offset correction operates at the same speed as the outer DC-bus control loop, while a faster loop mitigates third-harmonic voltage pulsations. Furthermore, a carrier-comparison-based implementation incorporating the proposed control is introduced. The effectiveness of the control strategy and its implementation is validated through simulations and experimental results on two hardware prototypes—one for TLC and another for VR.
- 16 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (11) , 16870-16893
Analytical Closed-Form ZVS Boundaries of Triple-Phase-Shift Modulated Dual Active Bridge Converter
A dual active bridge (DAB) is an isolated dc–dc converter that supports bidirectional power flow and hence finds a wide range of applications. To achieve high efficiency and power density, zero voltage switching (ZVS) is needed in all power devices. The magnitude of the current at the time of switching in a half-bridge leg must be more than a minimum value set by mosfet characteristics, dc bus voltages, series inductor value, selected dead-time values, etc. This is called the minimum ZVS current limit. One important step in devising the most general triple-phase-shift (TPS) modulation is to check if, given an operating condition (load and gain) and ZVS current limits, it is possible to achieve ZVS in all switching transitions. Currently, this is done numerically by evaluating a set of nonlinear equations and inequalities involving TPS modulation parameters, and hence, it is not suitable for real-time implementation. This article determines all possible pairs of minimum ZVS current limits the converter can support at a given operating condition. When ZVS cannot be achieved in all switches, this article outlines a procedure to design a shunt inductance to ensure ZVS with minimal increase in current stress. The proposed ZVS boundaries and shunt-inductance design procedure are experimentally verified in a laboratory-scale DAB prototype.
- 16 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (11) , 16870-16893
Analytical Closed-Form ZVS Boundaries of Triple-Phase-Shift Modulated Dual Active Bridge Converter
A dual active bridge (DAB) is an isolated dc–dc converter that supports bidirectional power flow and hence finds a wide range of applications. To achieve high efficiency and power density, zero voltage switching (ZVS) is needed in all power devices. The magnitude of the current at the time of switching in a half-bridge leg must be more than a minimum value set by mosfet characteristics, dc bus voltages, series inductor value, selected dead-time values, etc. This is called the minimum ZVS current limit. One important step in devising the most general triple-phase-shift (TPS) modulation is to check if, given an operating condition (load and gain) and ZVS current limits, it is possible to achieve ZVS in all switching transitions. Currently, this is done numerically by evaluating a set of nonlinear equations and inequalities involving TPS modulation parameters, and hence, it is not suitable for real-time implementation. This article determines all possible pairs of minimum ZVS current limits the converter can support at a given operating condition. When ZVS cannot be achieved in all switches, this article outlines a procedure to design a shunt inductance to ensure ZVS with minimal increase in current stress. The proposed ZVS boundaries and shunt-inductance design procedure are experimentally verified in a laboratory-scale DAB prototype.
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (2) , 2082-2097
Improved Model for Accurate Prediction of Crosstalk-Induced Gate–Source Voltage Peaks of SiC MOSFET With SiC Schottky Diode in a Half-Bridge Configuration
Fast switching transients of SiC MOSFETs reduce switching loss but generate high ( dv/dt ). During the active device’s turn-on transition, high ( dv/dt ) increases the complementary device’s gate-source voltage, potentially causing false turn-on, resulting in positive crosstalk. Conversely, during turn-off, the complementary device’s gate-source voltage decreases, causing negative crosstalk. Negative gate voltage can limit positive crosstalk peaks below the threshold but may intensify negative crosstalk peaks, possibly exceeding safe ratings and impacting reliability of SiC MOSFETs. This article presents an improved model to accurately predict crosstalk-induced gate-source voltage peaks of SiC MOSFETs. SiC Schottky diodes are utilized to avoid the reverse recovery of SiC MOSFET’s body diode. In addition to modeling nonlinear capacitances, parasitic inductances, and time-varying ( dv/dt ) from existing approaches, this article incorporates detailed channel current model and PCB parasitic capacitances for enhanced accuracy in predicting drain-source voltage gradient ( dv/dt ) of the active device and gate-source voltage peaks of the complementary device. Experimental results for two 1200V SiC MOSFETs from different manufacturers validate the proposed model. Using the model, optimal value of negative gate voltage and gate resistances are estimated to mitigate negative crosstalk and avoid false turn-on. Additionally, this article analyses post-false turn-on dynamics, providing critical insights into the process.
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (2) , 2082-2097
Improved Model for Accurate Prediction of Crosstalk-Induced Gate–Source Voltage Peaks of SiC MOSFET With SiC Schottky Diode in a Half-Bridge Configuration
Fast switching transients of SiC MOSFETs reduce switching loss but generate high ( dv/dt ). During the active device’s turn-on transition, high ( dv/dt ) increases the complementary device’s gate-source voltage, potentially causing false turn-on, resulting in positive crosstalk. Conversely, during turn-off, the complementary device’s gate-source voltage decreases, causing negative crosstalk. Negative gate voltage can limit positive crosstalk peaks below the threshold but may intensify negative crosstalk peaks, possibly exceeding safe ratings and impacting reliability of SiC MOSFETs. This article presents an improved model to accurately predict crosstalk-induced gate-source voltage peaks of SiC MOSFETs. SiC Schottky diodes are utilized to avoid the reverse recovery of SiC MOSFET’s body diode. In addition to modeling nonlinear capacitances, parasitic inductances, and time-varying ( dv/dt ) from existing approaches, this article incorporates detailed channel current model and PCB parasitic capacitances for enhanced accuracy in predicting drain-source voltage gradient ( dv/dt ) of the active device and gate-source voltage peaks of the complementary device. Experimental results for two 1200V SiC MOSFETs from different manufacturers validate the proposed model. Using the model, optimal value of negative gate voltage and gate resistances are estimated to mitigate negative crosstalk and avoid false turn-on. Additionally, this article analyses post-false turn-on dynamics, providing critical insights into the process.
- 6 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (12) , 15506-15519
A Single-Stage High-Frequency-Link Medium Voltage Ac to Dc Converter for Utility-Scale Grid Integration of Solar and Storage
This article presents an innovative galvanically isolated medium-voltage ac (MVAC) to low-voltage dc (LVDC) converter for MV grid integration of utility-scale renewables and storage. The converter supports bidirectional power flow at any power factor with high power quality. In the proposed solution, transformers are operated at high frequency, significantly reducing size and weight compared with conventional low-frequency step-down transformers followed by a hard-switched two or three-level ac–dc converter solution. The single-stage approach results in line frequency switching of MVAC side converter, leading to negligible switching loss and the elimination of large electrolytic capacitors needed for filtering second harmonic power, improving reliability, power density, and efficiency. A three-level architecture is adopted on each module's ac side high-frequency switched bridge, increasing the module voltage rating. This results in a 50% reduction in the number of series-connected modules and hence the complexity. Integration of LVDC side bridges into a single H-bridge dramatically reduces switch count, improves soft-switching capability, and reduces high-frequency rms current in the LVDC side bridge of the converter. This article provides a step-by-step design methodology. Experimental validation is demonstrated through an SiC-based 1.5 kV, 5 kW three-phase ac to LVDC module, achieving 95.8% efficiency and 3% ac side line current THD. The results affirm the efficacy of the proposed topology, modulation, and control strategy.
- 6 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (12) , 15506-15519
A Single-Stage High-Frequency-Link Medium Voltage Ac to Dc Converter for Utility-Scale Grid Integration of Solar and Storage
This article presents an innovative galvanically isolated medium-voltage ac (MVAC) to low-voltage dc (LVDC) converter for MV grid integration of utility-scale renewables and storage. The converter supports bidirectional power flow at any power factor with high power quality. In the proposed solution, transformers are operated at high frequency, significantly reducing size and weight compared with conventional low-frequency step-down transformers followed by a hard-switched two or three-level ac–dc converter solution. The single-stage approach results in line frequency switching of MVAC side converter, leading to negligible switching loss and the elimination of large electrolytic capacitors needed for filtering second harmonic power, improving reliability, power density, and efficiency. A three-level architecture is adopted on each module's ac side high-frequency switched bridge, increasing the module voltage rating. This results in a 50% reduction in the number of series-connected modules and hence the complexity. Integration of LVDC side bridges into a single H-bridge dramatically reduces switch count, improves soft-switching capability, and reduces high-frequency rms current in the LVDC side bridge of the converter. This article provides a step-by-step design methodology. Experimental validation is demonstrated through an SiC-based 1.5 kV, 5 kW three-phase ac to LVDC module, achieving 95.8% efficiency and 3% ac side line current THD. The results affirm the efficacy of the proposed topology, modulation, and control strategy.
- 6 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (8) , 10079-10094
Overmodulation Techniques of Asymmetrical Six-Phase Machine With Minimum RMS Current Ripple
An asymmetrical six-phase machine (ASPM) with two isolated neutral points is analyzed in two orthogonal subspaces: energy-transferring and harmonic subspaces. Overmodulation (OVM) techniques of ASPM extend the operating region of ASPM in the energy-transferring plane and thus attain higher voltage gain after injecting non-zero average voltage in the harmonic subspace. But due to low impedance in the harmonic subspace, the applied voltage causes large circulating current and copper loss. Hence, the RMS of the applied average voltage is minimized in the literature. It is also shown in the literature that for a given reference voltage vector in the OVM plane, there is more than one PWM sequence that can achieve the minimum injection of non-zero average voltage in harmonic subspace. But they have different high-frequency ripple currents. Although the current ripple is one of the essential performance indices, its study is missing for OVM techniques of ASPM. Hence, this work studies the current ripple performances of the above PWM sequences in the OVM region. One machine parameter, which is the ratio of inductances in energy-transferring and harmonic subspaces, impacts this current ripple. The article finds the sequence with the best ripple performance for a given reference vector in the OVM region and a machine parameter. After that, a PWM technique is proposed, which improves the high-frequency current ripple RMS by 623.67% and 416.53% compared to two existing OVM techniques for a feasible machine parameter. Theoretical analysis is validated through simulation and experiments on a hardware prototype at 4.2 kW power level.
- 6 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (8) , 10079-10094
Overmodulation Techniques of Asymmetrical Six-Phase Machine With Minimum RMS Current Ripple
An asymmetrical six-phase machine (ASPM) with two isolated neutral points is analyzed in two orthogonal subspaces: energy-transferring and harmonic subspaces. Overmodulation (OVM) techniques of ASPM extend the operating region of ASPM in the energy-transferring plane and thus attain higher voltage gain after injecting non-zero average voltage in the harmonic subspace. But due to low impedance in the harmonic subspace, the applied voltage causes large circulating current and copper loss. Hence, the RMS of the applied average voltage is minimized in the literature. It is also shown in the literature that for a given reference voltage vector in the OVM plane, there is more than one PWM sequence that can achieve the minimum injection of non-zero average voltage in harmonic subspace. But they have different high-frequency ripple currents. Although the current ripple is one of the essential performance indices, its study is missing for OVM techniques of ASPM. Hence, this work studies the current ripple performances of the above PWM sequences in the OVM region. One machine parameter, which is the ratio of inductances in energy-transferring and harmonic subspaces, impacts this current ripple. The article finds the sequence with the best ripple performance for a given reference vector in the OVM region and a machine parameter. After that, a PWM technique is proposed, which improves the high-frequency current ripple RMS by 623.67% and 416.53% compared to two existing OVM techniques for a feasible machine parameter. Theoretical analysis is validated through simulation and experiments on a hardware prototype at 4.2 kW power level.
- 14 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Investigation on the impact of External Layout-dependent Gate-Drain Capacitance on the Switching Dynamics of Si SJMOS
The external parasitic gate-drain capacitance is a constant capacitance that exists between the externally accessible gate and drain terminals of the power MOSFET, and it is contributed by the layout of the gate and drain nodes routed in the PCB. Due to its comparable magnitude with the internal gate-drain capacitance of the silicon superjunction MOSFETs, it can significantly affect the switching dynamics during the voltage-rise and voltage fall periods. This effect is even more pronounced for superjunction MOSFET with low current rating. In this work, a quantitative investigation of the impact of the parasitic gate-drain capacitance o the switching dynamics is presented and verified experimentally for a wide operating condition for a 650V and 12A silicon superjunction MOSFET.
- 14 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Investigation on the impact of External Layout-dependent Gate-Drain Capacitance on the Switching Dynamics of Si SJMOS
The external parasitic gate-drain capacitance is a constant capacitance that exists between the externally accessible gate and drain terminals of the power MOSFET, and it is contributed by the layout of the gate and drain nodes routed in the PCB. Due to its comparable magnitude with the internal gate-drain capacitance of the silicon superjunction MOSFETs, it can significantly affect the switching dynamics during the voltage-rise and voltage fall periods. This effect is even more pronounced for superjunction MOSFET with low current rating. In this work, a quantitative investigation of the impact of the parasitic gate-drain capacitance o the switching dynamics is presented and verified experimentally for a wide operating condition for a 650V and 12A silicon superjunction MOSFET.