Tien-The Nguyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Tien-The Nguyen has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Honnyong Cha
Kyungpook National University
7 shared publications - Bang Le-Huy Nguyen
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
1 shared publication - Dai-Van Bui
School of Energy Engineering, Kyungpook National University, Daegu, South Korea
1 shared publication - Duc-Tuan Do
Faculty of Electrical Engineering, Thai Nguyen University of Technology, Thai Nguyen 250000, Vietnam
1 shared publication - Emmanuel Seun Oluwasogo
School of Energy Engineering, Kyungpook National University, Daegu, South Korea
1 shared publication - Fazal Akbar
University of Edinburgh, Edinburgh, U.K.
1 shared publication
Latest Publications
- 21 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (9) , 10075-10085
Novel Automatic Current Balancing of Two-Phase Isolated Buck-Boost Converters
This article presents a family of the two-phase isolated buck-boost dc–dc converter with an automatic current balancing feature inhering from the series-capacitor (SC) high conversion ratio converter. The current of each module is automatically well-balanced regardless of the gate signals mismatch and different characteristics of the semiconductor switches utilized in the proposed converter. In addition, the SC combined with the two-phase current-fed full-bridge converter is typically analyzed in this study. To further enhance the reliability, the proposed converter with clamping voltage overshoot action is introduced. Moreover, the design parameters, equivalent circuits, switching schemes, and operation modes of the proposed dc–dc converter are described in detail. The current balancing principle of the two inductor currents in the designed converter is also explained. Furthermore, the performance of the proposed converter is analyzed in PSIM simulation. Lastly, a hardware prototype with a rated power of 2 kW was built and tested in different operating conditions to validate the analysis and effectiveness of the presented converter.
- 21 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (9) , 10075-10085
Novel Automatic Current Balancing of Two-Phase Isolated Buck-Boost Converters
This article presents a family of the two-phase isolated buck-boost dc–dc converter with an automatic current balancing feature inhering from the series-capacitor (SC) high conversion ratio converter. The current of each module is automatically well-balanced regardless of the gate signals mismatch and different characteristics of the semiconductor switches utilized in the proposed converter. In addition, the SC combined with the two-phase current-fed full-bridge converter is typically analyzed in this study. To further enhance the reliability, the proposed converter with clamping voltage overshoot action is introduced. Moreover, the design parameters, equivalent circuits, switching schemes, and operation modes of the proposed dc–dc converter are described in detail. The current balancing principle of the two inductor currents in the designed converter is also explained. Furthermore, the performance of the proposed converter is analyzed in PSIM simulation. Lastly, a hardware prototype with a rated power of 2 kW was built and tested in different operating conditions to validate the analysis and effectiveness of the presented converter.
- 17 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (12) , 14820-14830
Modified SVPWM for Three-Phase Six-Switch Switching-Cell Current Source Inverter
This article proposes a three-phase six-switch switching-cell current source inverter (H6-SC-CSI) and a modified switching scheme of space vector pulsewidth modulation (SVPWM). Compared to the conventional three-phase six-switch current source inverter, the H6-SC-CSI has no open-circuit possibility, thus, the inverter reliability is greatly enhanced. In addition, the overlap-time can be minimized; hence, the output waveform quality can be considerably improved. Due to the presence of switching-cell capacitors, a conventional switching sequence of the SVPWM is modified for the inverter to operate properly. A 2.2 kW hardware prototype is built and tested to verify the effectiveness of the proposed PWM.
- 17 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (12) , 14820-14830
Modified SVPWM for Three-Phase Six-Switch Switching-Cell Current Source Inverter
This article proposes a three-phase six-switch switching-cell current source inverter (H6-SC-CSI) and a modified switching scheme of space vector pulsewidth modulation (SVPWM). Compared to the conventional three-phase six-switch current source inverter, the H6-SC-CSI has no open-circuit possibility, thus, the inverter reliability is greatly enhanced. In addition, the overlap-time can be minimized; hence, the output waveform quality can be considerably improved. Due to the presence of switching-cell capacitors, a conventional switching sequence of the SVPWM is modified for the inverter to operate properly. A 2.2 kW hardware prototype is built and tested to verify the effectiveness of the proposed PWM.
- 3 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (6) , 5696-5706
Switching-Cell Structure-Based Generic Five-Level Current-Source Inverter
In this article, a new single-phase five-level current-source inverter is proposed. The proposed inverter provides open/short-circuit immunity and minimizes overlap time by adding four small film capacitors, thus enhancing the inverter's reliability. The efficiency and output waveforms quality are improved due to reduced overlap-time interval. The proposed inverter also provides natural balancing of the inductor currents. In addition, the n switching cells can be used to extend to the proposed N -level inverter. The operating principle, steady-state analysis, fault-state analysis, and parameter selections of the proposed inverter are presented. Furthermore, a comparative study of the proposed inverter and other five-level current-source inverters is addressed. Finally, a 1 kW prototype is implemented to verify the feasibility of the proposed inverter.
- 3 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (6) , 5696-5706
Switching-Cell Structure-Based Generic Five-Level Current-Source Inverter
In this article, a new single-phase five-level current-source inverter is proposed. The proposed inverter provides open/short-circuit immunity and minimizes overlap time by adding four small film capacitors, thus enhancing the inverter's reliability. The efficiency and output waveforms quality are improved due to reduced overlap-time interval. The proposed inverter also provides natural balancing of the inductor currents. In addition, the n switching cells can be used to extend to the proposed N -level inverter. The operating principle, steady-state analysis, fault-state analysis, and parameter selections of the proposed inverter are presented. Furthermore, a comparative study of the proposed inverter and other five-level current-source inverters is addressed. Finally, a 1 kW prototype is implemented to verify the feasibility of the proposed inverter.
- 2 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (12) , 12784-12794
Beta-Quasi-Z-Source (β-qZS) DC–DC Converter Without Duty Cycle Constraint for Wide Input Voltage Applications
A novel beta-quasi-Z-source (β-qZS) converter is proposed for an isolated dc–dc converter with the buck (step-down) and boost (step-up) functions. The β-qZS isolated dc–dc converter addresses the common challenges such as components stresses, reliability, suppression of switch voltage overshoot, size, and power derating in the existing impedance source-based isolated dc–dc converter applications. In addition, the proposed topology dealt with operating duty cycle constraint and loss of duty cycle phenomenon in the Z/qZS galvanically isolated dc–dc converters. This article describes the configuration and provides the principle of operation for the proposed β-qZS converter topology. A laboratory prototype is developed, and the experimental results satisfy the theoretical analysis.
- 2 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (12) , 12784-12794
Beta-Quasi-Z-Source (β-qZS) DC–DC Converter Without Duty Cycle Constraint for Wide Input Voltage Applications
A novel beta-quasi-Z-source (β-qZS) converter is proposed for an isolated dc–dc converter with the buck (step-down) and boost (step-up) functions. The β-qZS isolated dc–dc converter addresses the common challenges such as components stresses, reliability, suppression of switch voltage overshoot, size, and power derating in the existing impedance source-based isolated dc–dc converter applications. In addition, the proposed topology dealt with operating duty cycle constraint and loss of duty cycle phenomenon in the Z/qZS galvanically isolated dc–dc converters. This article describes the configuration and provides the principle of operation for the proposed β-qZS converter topology. A laboratory prototype is developed, and the experimental results satisfy the theoretical analysis.
- Open Access
- 13 August 2021
- Published by Vietnam Association of Catalysis and Adsorption in Vietnam Journal of Catalysis and Adsorption
- Vol. 11 (1) , 22-28
Synthesis of UiO-66 materials applied to arsenic adsorption in water
In this study, metal-organic frameworks containing zirconium was successfully synthesized at soft conditions (temperature 25oC and ambient pressure). UiO-66 samples were characterized by XRD, FTIR, SEM, EDX and BET. The SEM-image result showed UiO-66 particles size of 100-200 nm. UiO-66 sample showed the high surface area (1436 m2/g) and high pore volume (0.707 cm3/g). The UiO-66 samples tested were used as an adsorbent to remove aquatic arsenic contamination. UiO-66 materials has a high ability to remove arsenic, reaching 78.82 %. The UiO-66 adsorbent functions excellently across a broad pH range of 1 to 11 and achieves a remarkable arsenate uptake capacity of 294.12 mg/g.
- 13 August 2021
- Published by Vietnam Association of Catalysis and Adsorption in Vietnam Journal of Catalysis and Adsorption
- Vol. 11 (1) , 22-28
Open AccessSynthesis of UiO-66 materials applied to arsenic adsorption in water
In this study, metal-organic frameworks containing zirconium was successfully synthesized at soft conditions (temperature 25oC and ambient pressure). UiO-66 samples were characterized by XRD, FTIR, SEM, EDX and BET. The SEM-image result showed UiO-66 particles size of 100-200 nm. UiO-66 sample showed the high surface area (1436 m2/g) and high pore volume (0.707 cm3/g). The UiO-66 samples tested were used as an adsorbent to remove aquatic arsenic contamination. UiO-66 materials has a high ability to remove arsenic, reaching 78.82 %. The UiO-66 adsorbent functions excellently across a broad pH range of 1 to 11 and achieves a remarkable arsenate uptake capacity of 294.12 mg/g.
- 4 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (7) , 6859-6869
Five-Level Current Source Inverter With Inductor Cell Using Switching-Cell Structure
This article proposes a single-phase five-level current source inverter with an inductor cell based on the switching-cell (SC) structure. Compared to the conventional inverter, the proposed structure has no open-circuit problem; thus, its reliability is greatly enhanced. The overlap-time inserted in the driving signals can also be minimized to improve the output waveform quality. The proposed inverter's operation is analyzed herein, and the design guideline of SC capacitors is discussed. In addition, the SC extension for the n -level topology is provided. A 1-kW prototype is built and tested to validate the effectiveness of the proposed structure.
- 4 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (7) , 6859-6869
Five-Level Current Source Inverter With Inductor Cell Using Switching-Cell Structure
This article proposes a single-phase five-level current source inverter with an inductor cell based on the switching-cell (SC) structure. Compared to the conventional inverter, the proposed structure has no open-circuit problem; thus, its reliability is greatly enhanced. The overlap-time inserted in the driving signals can also be minimized to improve the output waveform quality. The proposed inverter's operation is analyzed herein, and the design guideline of SC capacitors is discussed. In addition, the SC extension for the n -level topology is provided. A 1-kW prototype is built and tested to validate the effectiveness of the proposed structure.
- 31 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (12) , 12046-12057
Current-Fed Quasi-Z-Source Full-Bridge Isolated DC–DC Converter
This paper presents current-fed (CF) full-bridge (FB) isolated dc-dc converter using quasi-Z-source network. Owing to its inherent buck-boost and clamping function, the proposed converter can effectively eliminate start-up and switch voltage overshoot problems. In addition, when compared with the conventional CF-FB converter with active-clamp, switch current stress is much reduced and less active switches are required. Operation principles of the proposed converter are analyzed in detail. The simulation and experimental results with 1 kW prototype are also provided to verify theoretical analysis.
- 31 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (12) , 12046-12057
Current-Fed Quasi-Z-Source Full-Bridge Isolated DC–DC Converter
This paper presents current-fed (CF) full-bridge (FB) isolated dc-dc converter using quasi-Z-source network. Owing to its inherent buck-boost and clamping function, the proposed converter can effectively eliminate start-up and switch voltage overshoot problems. In addition, when compared with the conventional CF-FB converter with active-clamp, switch current stress is much reduced and less active switches are required. Operation principles of the proposed converter are analyzed in detail. The simulation and experimental results with 1 kW prototype are also provided to verify theoretical analysis.
- 2 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (4) , 3365-3376
A Novel Single-Phase Three-Level Dual-Buck Inverter
This paper proposes a new single-phase three-level dual-buck inverter. The topology is derived from a simplified neutral-point clamped inverter that includes fewer active switches. The advantages of the proposed inverter are no shoot-through worries and no reverse recovery issue of the body diode of the power metal-oxide-semiconductor field-effect transistor compared with the conventional inverter; therefore, a high-reliability inverter can be achieved. The operation modes and pulse-width modulation technique are analyzed in detail. Additionally, a switching scheme is proposed to balance and reduce the direct-current-link capacitance. A 1.4-kW prototype was built and tested to validate the theoretical analysis of the proposed converter.
- 2 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (4) , 3365-3376
A Novel Single-Phase Three-Level Dual-Buck Inverter
This paper proposes a new single-phase three-level dual-buck inverter. The topology is derived from a simplified neutral-point clamped inverter that includes fewer active switches. The advantages of the proposed inverter are no shoot-through worries and no reverse recovery issue of the body diode of the power metal-oxide-semiconductor field-effect transistor compared with the conventional inverter; therefore, a high-reliability inverter can be achieved. The operation modes and pulse-width modulation technique are analyzed in detail. Additionally, a switching scheme is proposed to balance and reduce the direct-current-link capacitance. A 1.4-kW prototype was built and tested to validate the theoretical analysis of the proposed converter.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21506078,p. 2776-2781
Selective harmonic elimination for cascaded multilevel inverters using Grey Wolf Optimizer algorithm
In this paper, Grey Wolf Optimizer (GWO) algorithm is applied to determine optimum switching angles for cascaded multilevel inverter of eliminating some high order harmonics while maintaining the required fundamental voltage. As case study in this paper, 11-level and 15-level inverter are considered and the optimum switching angles are calculated off-line to eliminate the 5th, 7th, 11th, 13th harmonics for the 11-level as well as 17th, 19th harmonics for 15-level. The total harmonic distortion is used to estimate the quality of output voltages. The results are shown graphically for better understanding, the mathematical formulations and simulation results will be presented.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21506078,p. 2776-2781
Selective harmonic elimination for cascaded multilevel inverters using Grey Wolf Optimizer algorithm
In this paper, Grey Wolf Optimizer (GWO) algorithm is applied to determine optimum switching angles for cascaded multilevel inverter of eliminating some high order harmonics while maintaining the required fundamental voltage. As case study in this paper, 11-level and 15-level inverter are considered and the optimum switching angles are calculated off-line to eliminate the 5th, 7th, 11th, 13th harmonics for the 11-level as well as 17th, 19th harmonics for 15-level. The total harmonic distortion is used to estimate the quality of output voltages. The results are shown graphically for better understanding, the mathematical formulations and simulation results will be presented.