Paweł Kułaga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Paweł Kułaga has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Jacek Jaworski
Oil and Gas Institute—National Research Institute, ul. Lubicz 25a, 31-503 Kraków, Poland
5 shared publications - Giorgio Ficco
Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, 03043 Cassino, Italy
3 shared publications - Alessandro Guzzini
Department of Industrial Engineering (DIN), University of Bologna, Viale Risorgimento, 2, 40136 Bologna, Italy
2 shared publications Diana Enescu
2 shared publicationsInstytut Nafty i Gazu – Państwowy Instytut Badawczy
2 shared publications- Marco Dell’isola
Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, 03043 Cassino, Italy
2 shared publications
Latest Publications
- Open Access
- 30 August 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 86, 343-362
Hydrogen in natural gas grids: prospects and recommendations about gas flow meters
- 30 August 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 86, 343-362
Open AccessHydrogen in natural gas grids: prospects and recommendations about gas flow meters
- 15 March 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 62, 892-903
Effect of hydrogen blending on the accuracy of smart gas meters
- 15 March 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 62, 892-903
Effect of hydrogen blending on the accuracy of smart gas meters
- Open Access
- 2 March 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 67, 1295-1307
Hydrogen blending effect on fiscal and metrological instrumentation: A review
- 2 March 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 67, 1295-1307
Open AccessHydrogen blending effect on fiscal and metrological instrumentation: A review
- Open Access
Reliability of Domestic Gas Flow Sensors with Hydrogen Admixtures
Static flow sensors (e.g., thermal gas micro electro-mechanical sensors—MEMS—and ultrasonic time of flight) are becoming the prevailing technology for domestic gas metering and billing since they show advantages in respect to the traditional volumetric ones. However, they are expected to be influenced in-service by changes in gas composition, which in the future could be more frequent due to the spread of hydrogen admixtures in gas networks. In this paper, the authors present the results of an experimental campaign aimed at analyzing the in-service reliability of both static and volumetric gas meters with different hydrogen admixtures. The results show that the accuracy of volumetric and ultrasonic meters is always within the admitted limits for subsequent verification and even within those narrower of the initial verification. On the other hand, the accuracy of the first generation of thermal mass gas flow sensors is within the limits of the verification only when the hydrogen admixture is below 2%vol. At higher hydrogen content, in fact, the absolute weighted mean error ranges between 3.5% (with 5%vol of hydrogen) and 15.8% (with 10%vol of hydrogen).
Open AccessReliability of Domestic Gas Flow Sensors with Hydrogen Admixtures
Static flow sensors (e.g., thermal gas micro electro-mechanical sensors—MEMS—and ultrasonic time of flight) are becoming the prevailing technology for domestic gas metering and billing since they show advantages in respect to the traditional volumetric ones. However, they are expected to be influenced in-service by changes in gas composition, which in the future could be more frequent due to the spread of hydrogen admixtures in gas networks. In this paper, the authors present the results of an experimental campaign aimed at analyzing the in-service reliability of both static and volumetric gas meters with different hydrogen admixtures. The results show that the accuracy of volumetric and ultrasonic meters is always within the admitted limits for subsequent verification and even within those narrower of the initial verification. On the other hand, the accuracy of the first generation of thermal mass gas flow sensors is within the limits of the verification only when the hydrogen admixture is below 2%vol. At higher hydrogen content, in fact, the absolute weighted mean error ranges between 3.5% (with 5%vol of hydrogen) and 15.8% (with 10%vol of hydrogen).
- Open Access
Domestic Gas Meter Durability in Hydrogen and Natural Gas Mixtures
Blending hydrogen into the natural gas infrastructure is becoming a very promising practice to increase the exploitation of renewable energy sources which can be used to produce “green” hydrogen. Several research projects and field experiments are currently aimed at evaluating the risks associated with utilization of the gas blend in end-use devices such as the gas meters. In this paper, the authors present the results of experiments aimed at assessing the effect of hydrogen injection in terms of the durability of domestic gas meters. To this end, 105 gas meters of different measurement capabilities and manufacturers, both brand-new and withdrawn from service, were investigated in terms of accuracy drift after durability cycles of 5000 and 10,000 h with H2NG mixtures and H2 concentrations of 10% and 15%. The obtained results show that there is no metrologically significant or statistically significant influence of hydrogen content on changes in gas meter indication errors after subjecting the meters to durability testing with a maximum of 15% H2 content over 10,000 h. A metrologically significant influence of the long-term operation of the gas meters was confirmed, but it should not be made dependent on the hydrogen content in the gas. No safety problems related to the loss of external tightness were observed for either the new or 10-year-old gas meters.
Open AccessDomestic Gas Meter Durability in Hydrogen and Natural Gas Mixtures
Blending hydrogen into the natural gas infrastructure is becoming a very promising practice to increase the exploitation of renewable energy sources which can be used to produce “green” hydrogen. Several research projects and field experiments are currently aimed at evaluating the risks associated with utilization of the gas blend in end-use devices such as the gas meters. In this paper, the authors present the results of experiments aimed at assessing the effect of hydrogen injection in terms of the durability of domestic gas meters. To this end, 105 gas meters of different measurement capabilities and manufacturers, both brand-new and withdrawn from service, were investigated in terms of accuracy drift after durability cycles of 5000 and 10,000 h with H2NG mixtures and H2 concentrations of 10% and 15%. The obtained results show that there is no metrologically significant or statistically significant influence of hydrogen content on changes in gas meter indication errors after subjecting the meters to durability testing with a maximum of 15% H2 content over 10,000 h. A metrologically significant influence of the long-term operation of the gas meters was confirmed, but it should not be made dependent on the hydrogen content in the gas. No safety problems related to the loss of external tightness were observed for either the new or 10-year-old gas meters.
- Open Access
- 1 October 2019
- Published by The Oil and Gas Institute - National Research Institute in Nafta-Gaz
- Vol. 75 (10) , 625-632
Wybrane zagadnienia dotyczące wpływu dodatku wodoru do gazu ziemnego na elementy systemu gazowniczego
- 1 October 2019
- Published by The Oil and Gas Institute - National Research Institute in Nafta-Gaz
- Vol. 75 (10) , 625-632
Open AccessWybrane zagadnienia dotyczące wpływu dodatku wodoru do gazu ziemnego na elementy systemu gazowniczego
- 1 May 2017
- Published by The Oil and Gas Institute - National Research Institute in Nafta-Gaz
- Vol. 73 (5) , 332-339
Wzorcowanie wysokociśnieniowe gazomierzy – stanowisko z pętlą zamkniętą
- 1 May 2017
- Published by The Oil and Gas Institute - National Research Institute in Nafta-Gaz
- Vol. 73 (5) , 332-339
Wzorcowanie wysokociśnieniowe gazomierzy – stanowisko z pętlą zamkniętą
- 1 August 2016
- Published by The Oil and Gas Institute - National Research Institute in Nafta-Gaz
- Vol. 8, 645-650
Wyniki badań trwałości gazomierzy miechowych uzyskiwane z zastosowaniem różnych metodyk – analiza porównawcza
- 1 August 2016
- Published by The Oil and Gas Institute - National Research Institute in Nafta-Gaz
- Vol. 8, 645-650
Wyniki badań trwałości gazomierzy miechowych uzyskiwane z zastosowaniem różnych metodyk – analiza porównawcza