SJSiôn Gwyn Jones

Siôn Gwyn Jones

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Siôn Gwyn Jones has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Variation between hospitals in outcomes following cardiac surgery in the UK

    by G Soppa, P Theodoropoulos, R Bilkhu, DA Harrison, R Alam, R Beattie, D Bleetman, A Hussain, S Jones, L Kenny, et al.

    Introduction: We examine the influence of variations in provision of cardiac surgery in the UK at hospital level on patient outcomes and also to assess whether there is an inequality of access and delivery of healthcare. Cardiothoracic surgery has pioneered the reporting of surgeon-specific outcomes, which other specialties have followed. We set out to identify factors other than the individual surgeon, which can affect outcomes and enable other surgical specialties to adopt a similar model. Materials and methods: A retrospective analysis of prospectively collected data of patient and hospital level factors between 2013 and 2016 from 16 cardiac surgical units in the UK were analysed through the Society for Cardiothoracic Surgery of Great Britain and Ireland and the Royal College of Surgeons Research Collaborative. Patient demographic data, risks factors, postoperative complications and in-hospital mortality, as well as hospital-level factors such as number of beds and operating theatres, were collected. Correlation between outcome measures was assessed using Pearson’s correlation coefficient. Associations between hospital-level factors and outcomes were assessed using univariable and multivariable regression models. Results: Of 50,871 patients (60.5% of UK caseload), 25% were older than 75 years and 29% were female. There was considerable variation between units in patient comorbidities, bed distribution and staffing. All hospitals had dedicated cardiothoracic intensive care beds and consultants. Median survival was 97.9% (range 96.3–98.6%). Postoperative complications included re-sternotomy for bleeding (median 4.8%; range 3.5–6.9%) and mediastinitis (0.4%; 0.1–1.0%), transient ischaemic attack/cerebrovascular accident (1.7%; range 0.3–3.0%), haemofiltration (3.7%; range 0.8–6.8%), intra-aortic balloon pump use (3.3%; range 0.4–7.4%), tracheostomy (1.6%; range 1.3–2.6%) and laparotomy (0.3%; range 0.2–0.6%). There was variation in outcomes between hospitals. Univariable analysis showed a small number of positive associations between hospital-level factors and outcomes but none remained significant in multivariable models. Conclusions: Variations among hospital level factors exists in both delivery of, and outcomes, following cardiac surgery in the UK. However, there was no clear association between these factors and patient outcomes. This negative finding could be explained by differences in outcome definition, differences in risk factors between centres that are not captured by standard risk stratification scores or individual surgeon/team performance.


  • Limited versus full sternotomy for aortic valve replacement

    by Bilal H Kirmani, Sion G Jones, S C Malaisrie, Darryl A Chung, Richard Jnn Williams

    Aortic valve disease is a common condition that is easily treatable with cardiac surgery. This is conventionally performed by opening the sternum longitudinally down the centre ("median sternotomy") and replacing the valve under cardiopulmonary bypass. Median sternotomy is generally well tolerated, but as less invasive options have become available, the efficacy of limited incisions has been called into question. In particular, the effects of reducing the visibility and surgical access has raised safety concerns with regards to the placement of cannulae, venting of the heart, epicardial wire placement, and de-airing of the heart at the end of the procedure. These difficulties may increase operating times, affecting outcome. The benefits of smaller incisions are thought to include decreased pain; improved respiratory mechanics; reductions in wound infections, bleeding, and need for transfusion; shorter intensive care stay; better cosmesis; and a quicker return to normal activity. To assess the effects of minimally invasive aortic valve replacement via a limited sternotomy versus conventional aortic valve replacement via median sternotomy in people with aortic valve disease requiring surgical replacement. We performed searches of CENTRAL, MEDLINE, Embase, clinical trials registries, and manufacturers' websites from inception to July 2016, with no language limitations. We reviewed references of identified papers to identify any further studies of relevance. Randomised controlled trials comparing aortic valve replacement via a median sternotomy versus aortic valve replacement via a limited sternotomy. We excluded trials that performed other minimally invasive incisions such as mini-thoracotomies, port access, trans-apical, trans-femoral or robotic procedures. Although some well-conducted prospective and retrospective case-control and cohort studies exist, these were not included in this review. Two review authors independently assessed trial papers to extract data, assess quality, and identify risk of bias. A third review author provided arbitration where required. The quality of evidence was determined using the GRADE methodology and results of patient-relevant outcomes were summarised in a 'Summary of findings' table. The review included seven trials with 511 participants. These included adults from centres in Austria, Spain, Italy, Germany, France, and Egypt. We performed 12 comparisons investigating the effects of minimally invasive limited upper hemi-sternotomy on aortic valve replacement as compared to surgery performed via full median sternotomy. There was no evidence of any effect of upper hemi-sternotomy on mortality versus full median sternotomy (risk ratio (RR) 1.01, 95% confidence interval (CI) 0.36 to 2.82; participants = 511; studies = 7; moderate quality). There was no evidence of an increase in cardiopulmonary bypass time with aortic valve replacement performed via an upper hemi-sternotomy (mean difference (MD) 3.02 minutes, 95% CI -4.10 to 10.14; participants = 311; studies = 5; low quality). There was no evidence of an increase in aortic cross-clamp time (MD 0.95 minutes, 95% CI -3.45 to 5.35; participants = 391; studies = 6; low quality). None of the included studies reported major adverse cardiac and cerebrovascular events as a composite end point. There was no evidence of an effect on length of hospital stay through limited hemi-sternotomy (MD -1.31 days, 95% CI -2.63 to 0.01; participants = 297; studies = 5; I2 = 89%; very low quality). Postoperative blood loss was lower in the upper hemi-sternotomy group (MD -158.00 mL, 95% CI -303.24 to -12.76; participants = 297; studies = 5; moderate quality). The evidence did not support a reduction in deep sternal wound infections (RR 0.71, 95% CI 0.22 to 2.30; participants = 511; studies = 7; moderate quality) or re-exploration (RR 1.01, 95% CI 0.48 to 2.13; participants = 511; studies = 7; moderate quality). There was no change in pain scores by upper hemi-sternotomy (standardised mean difference (SMD) -0.33, 95% CI -0.85 to 0.20; participants = 197; studies = 3; I2 = 70%; very low quality), but there was a small increase in postoperative pulmonary function tests with minimally invasive limited sternotomy (MD 1.98 % predicted FEV1, 95% CI 0.62 to 3.33; participants = 257; studies = 4; I2 = 28%; low quality). There was a small reduction in length of intensive care unit stays as a result of the minimally invasive upper hemi-sternotomy (MD -0.57 days, 95% CI -0.93 to -0.20; participants = 297; studies = 5; low quality). Postoperative atrial fibrillation was not reduced with minimally invasive aortic valve replacement through limited compared to full sternotomy (RR 0.60, 95% CI 0.07 to 4.89; participants = 240; studies = 3; moderate quality), neither were postoperative ventilation times (MD -1.12 hours, 95% CI -3.43 to 1.19; participants = 297; studies = 5; low quality). None of the included studies reported cost analyses. The evidence in this review was assessed as generally low to moderate quality. The study sample sizes were small and underpowered to demonstrate differences in outcomes with low event rates. Clinical heterogeneity both between and within studies is a relatively fixed feature of surgical trials, and this also contributed to the need for caution in interpreting results. Considering these limitations, there was uncertainty of the effect on mortality or extracorporeal support times with upper hemi-sternotomy for aortic valve replacement compared to full median sternotomy. The evidence to support a reduction in total hospital length of stay or intensive care stay was low in quality. There was also uncertainty of any difference in the rates of other, secondary outcome measures or adverse events with minimally invasive limited sternotomy approaches to aortic valve replacement. There appears to be uncertainty between minimally invasive aortic valve replacement via upper hemi-sternotomy and conventional aortic valve replacement via a full median sternotomy. Before widespread adoption of the minimally invasive approach can be recommended, there is a need for a well-designed and adequately powered prospective randomised controlled trial. Such a study would benefit from performing a robust cost analysis. Growing patient preference for minimally invasive techniques merits thorough quality-of-life analyses to be included as end points, as well as quantitative measures of physiological reserve.


  • A meta-analysis of platelet gel for prevention of sternal wound infections following cardiac surgery

    by Bilal H Kirmani, Siôn G Jones, Subir Datta, Edward K Mclaughlin, Andreas J Hoschtitzky

    Deep sternal wound infection and bleeding are devastating complications following cardiac surgery, which may be reduced by topical application of autologous platelet gel. Systematic review identified seven comparative studies involving 4,692 patients. Meta-analysis showed significant reductions in all sternal wound infections (odds ratio 3.48 [1.08-11.23], p=0.04) and mediastinitis (odds ratio 2.69 [1.20-6.06], p=0.02) but not bleeding. No adverse events relating to the use of topical platelet-rich plasma were reported. The use of autologous platelet gel in cardiac surgery appears to provide significant reductions in serious sternal wound infections, and its use is unlikely to be associated with significant risk.


  • Stem Cells Accumulate on a Decellularized Arterial Xenograft In Vivo

    by Siôn G. Jones, Yanhua Hu, Qingbo Xu, Marjan Jahangiri


    • 1 March 2013
      • Vol. 22  (2) , 204-8

    Outcomes of transcatheter aortic valve implantation compared to surgical aortic valve replacement following previous surgery.

    by Sion G Jones, Nada R Abdulkareem, Frances Williams, Stephen Brecker, Marjan Jahangiri

    Surgical aortic valve replacement remains the 'gold standard' treatment for aortic valve disease. An increasing number of elderly patients with multiple comorbidities are referred for transcatheter aortic valve implantation (TAVI), partly due to the perceived high risks of surgery. These include in particular patients who have had previous cardiac surgery. The study aim was to compare the outcomes of patients with aortic valve disease and previous cardiac surgery who underwent TAVI, with those who had redo surgery. Patients were identified with aortic valve disease and previous cardiac surgery referred to the authors' multidisciplinary meeting. Patient characteristics were noted, together with their allocation to either re-do surgery or TAVI. A total of 20 patients who had undergone previous cardiac surgery was allocated to TAVI; these were matched to 20 patients who had undergone previous surgery and subsequently had redo surgery. Treatment modalities were chosen for individual patients according to their EuroSCORE, together with other factors not accounted for in traditional scoring systems. Between June 2008 and March 2010, a total of 191 patients was discussed; of these patients, 63 underwent TAVI, 20 of whom had undergone previous cardiac surgery. There was no significant difference in the EuroSCORE between groups (18 +/- 2 versus 19 +/- 3.0, p = 0.91). TAVI patients had a higher body mass index (27.1 +/- 3.9 versus 21.8 +/- 0.5 kg/m2, p = 0.0001). There were no deaths at 30 days in either group. One patient (5%) in the TAVI group had a transient ischemic attack following the procedure, and one (5%) had a hematoma at the site of arterial puncture. There were more pacemaker implantations in the TAVI group than in the redo group (25% versus 0%, p = 0.02). Improved risk stratification and its understanding in patients with aortic valve disease and previous cardiac surgery is required. Despite the perceived high risks in the surgically treated group, there were no deaths and redo surgery patients had lower rates of stroke and pacemaker implantation than did those who underwent TAVI.