JBJonathan Bortfeldt

Jonathan Bortfeldt

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jonathan Bortfeldt has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • μRWELL-PICOSEC: Precision timing with resistive micro-well detector

    by K. Gnanvo, R. Aleksan, Y. Angelis, S. Aune, J. Bortfeldt, F. Brunbauer, M. Brunoldi, E. Chatzianagnostou, J. Datta, K. Dehmelt, et al.

  • Open Access

    Radioactive ion beam range adaptation in mouse tumors using in-beam PET.

    by Martina Moglioni, Tamara Vitacchio, Francesco Evangelista, Munetaka Nitta, Daria Boscolo, Giulio Lovatti, Olga Sokol, Emma Haettner, Sivaji Purushothaman, Walter Tinganelli, et al.

    Treatment adaptation is particularly critical in particle therapy, where even small range deviations can compromise target coverage or lead to unintended dose delivered to surrounding healthy tissues. In-beam positron emission tomography (PET) has emerged as a promising approach for range verification during irradiation with protons or stable carbon ion beams. However, its clinical use is limited by low signal-to-noise ratio and by the spatial mismatch between activity and dose distributions, reducing verification accuracy and limiting timely intervention. We used radioactive ion beams for real-time range adaptation in 10 weeks old C3H/ HeNRj female mice bearing LM8-osteosarcoma tumors. Three 11C beam range settings were planned: short (S), right (R), and long (L). The range of a collimated monoenergetic probing beam was monitored in real-time with the SIRMIO in-beam PET scanner by tracking the activity peak along the beam path, while range adaptation was achieved with a remotely controlled range shifter. Each plan (S, R and L) was also delivered, and tumor growth, toxicity assays, and histological analyses were performed to evaluate each treatment outcomes. Dynamic repositioning of the 11C beam produced spatially resolved PET signals that correlated with distinct biological outcomes. Toxicity was observed only in the L group, while adequate tumor coverage was achieved in both R and L groups. In contrast, the S group showed continued tumor growth. We provide the first demonstration that in-beam imaging of radioactive ion beams can enable real-time range-guided radiotherapy in a living organism. These findings establish radioactive ion beams as a promising platform for precision range-guided particle therapy.

  • Open Access

    Design and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET

    by A. Kallitsopoulou, S. Aune, Y. Angelis, R. Aleksan, A. Bonenfant, J. Bortfeldt, F. Brunbauer, M. Brunoldi, J. Datta, D. Desforge, et al.

    The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector concept that achieves picosecond-level timing. It couples a Cherenkov radiator, typically an MgF 2 crystal, to a Micromegas-based photodetector equipped with a photocathode, allowing the fast photoelectron-induced signal to suppress the intrinsic time jitter characteristic of gaseous detectors. This design enables sub-20 ps timing precision while preserving the robustness and scalability of Micro-Pattern Gaseous Detector (MPGD) technologies. The 96-pad PICOSEC-MM detector represents the latest advancement in this development, optimized for precision timing in high-energy physics. Building upon the R&D insights obtained with earlier 7-pad resistive prototypes, this large-area demonstrator was developed to validate the scalability, uniformity, and robustness of the technology for integration into the ENUBET project. The detector employs a 2.5 nm Diamond-Like Carbon (DLC) photocathode with a Micromegas board equipped with surface resistivity of 10 MΩ/□, providing an excellent timing performance. The prototype was characterized using 150 GeV/ c muons at the CERN SPS beamline, with one-third of the active area instrumented during each run. A dedicated alignment procedure, developed for multi-pad PICOSEC-MM systems, was used to reconstruct the pad centers and combine measurements across different detector regions. The measured timing resolution was 43 ps across the instrumented pads, while the Signal Arrival Time (SAT) distributions exhibited a good uniformity among the detector area that was tested. Mechanical flatness was identified as a key factor influencing timing precision. Maintaining a planarity tolerance within 10 μm is therefore critical to preserve a good timing resolution over large active areas. The successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept marking a significant step toward implementing robust, high-granularity, picosecond-level gaseous timing detectors in monitored neutrino beam experiments such as ENUBET.


  • Open Access

    Collimated and non-collimated proton minibeam irradiation using SIRMIO: a simulation study

    by Fardous Reaz, Ze Huang, Marco Pinto, Jonathan Bortfeldt, Niels Bassler, Katia Parodi

    Background and purpose: Successful clinical integration of pMBRT requires comprehensive investigations of the relationship between various pMBRT parameters and their associated biological effects. Such investigations are critically dependent on small animal models. Therefore, a state-of-the-art small animal irradiation platform like SIRMIO (Small Animal Proton Irradiator for Research in Molecular Image-guided Radiation-Oncology), capable of delivering precisely controlled spatially fractionated doses, is highly desirable for advancing preclinical pMBRT research. Material and methods: This in silico study evaluates the SIRMIO beamline’s capability to deliver beams essential for pMBRT experiments. We used Geant4-based Monte Carlo simulations to investigate two configurations: one without a collimator, and one using a 30 mm thick brass multislit collimator (MSC). For both configurations, we examined center-to-center (CTC) of 3, 4, and 5 mm, with a constant 1 mm slit width when MSC is used. Results: The SIRMIO beamline can effectively generate spatially fractionated dose profiles with varying CTC. Without a collimator, sufficient dose contrast for pMBRT can be achieved with CTC of 4 mm and above, as evidenced by peak-to-valley dose ratios (PVDR) of 3.44 and 6.57 for 4 and 5 mm CTC, respectively. MSC further enhances dose contrast, achieving PVDR of 11.3, 20.7, and 28.7 for 3, 4, and 5 mm CTC, respectively. Furthermore, we explored interlacing beams as a means of achieving a uniform target dose while preserving dose contrast in normal tissue, demonstrating the potential of this approach using the SIRMIO beamline. Interpretation: The SIRMIO platform can be a viable option for pMBRT experiments.

  • Open Access

    Image-guided treatment of mouse tumours with radioactive ion beams

    by Daria Boscolo, Giulio Lovatti, Olga Sokol, Tamara Vitacchio, Martina Moglioni, Francesco Evangelista, Emma Haettner, Walter Tinganelli, Christian Graeff, Uli Weber, et al.

    Charged particle therapy with protons or heavier ions is one of the most effective radiotherapy techniques, but uncertainties in the beam range can limit its efficacy. Radioactive ion beams are ideal for image-guided particle therapy because isotopes that undergo β+ decay can be visualized with positron emission tomography. This allows spatial localization of the particle distribution in vivo, which can be correlated with the expected dose deposition for online beam range verification. Here we report the successful treatment of a mouse osteosarcoma using a radioactive 11C-ion beam. The tumour was located in the neck, close to the spinal cord, where deviations of even a few millimetres in the beam range could lead to unintended dose deposition in the spine and radiation-induced myelopathy, an injury to the spinal cord. We achieved complete tumour control with the highest dose of 20 Gy while avoiding paralysis. Low-grade neurological side effects were correlated to the activity measured by positron emission tomography in the spine. The biological washout of the activity from the tumour volume was dependent on the dose, indicating a potential component of vascular damage at high doses. This experiment marks a step towards future clinical applications of radioactive ion beams.


  • Open Access

    Development of a breathing lung phantom for proton CT imaging

    by V Wegener, T Fischer, M Rabe, G Landry, R W Schulte, K Parodi, J Bortfeld, M Pankuch, R P Johnson, J Lascaud, et al.

    Objective. To report on the design of a deformable lung phantom capable of imitating breathing motion with realistic tissue surrogate properties for proton imaging applications. Approach. The phantom was manufactured via 3D printing and silicone moulding, with a customised structural design for motor-controlled breathing motion. The overall size of the phantom was rescaled to fit in the experimental proton computed tomography (pCT) scanner prototype, featuring a 284 mm maximum size for the imaging field-of-view. Several flexible resins were evaluated in perspective of flexibility by varying ultraviolet exposure times, as increased exposure results in resin hardening at each layer. We optimised the structure to achieve ideal lung compression properties, while preserving its integrity to hold the weight of a solid tumour. Phantom material properties were characterised by segmentation of each component in x-ray CT and pCT images, to determine the CT number expressed in Hounsfield units and the relative stopping power (RSP) with respect to water. Main results. We achieved non-homogenous compression in the lung using a grid structure with gradient thickness. The rigid ribcage was 3D printed using granite based material. The tumour motion implemented in the phantom design, as measured using template-matching in fluoroscopic x-ray imaging, revealed hysteretic motion with 10 mm peak-to-peak in the superior–inferior direction. Significance. The developed deformable lung phantom imitated lung motion characteristics, featuring CT number and RSP values in the range comparable to human tissues. The developed breathing phantom is put forward for experimental motion studies in pCT imaging.


  • PICOSEC Micromegas precise-timing detectors: development towards large-area application and integration

    by Y. Meng, R. Aleksan, Y. Angelis, J. Bortfeldt, F. Brunbauer, M. Brunoldi, E. Chatzianagnostou, J. Datta, K. Degmelt, G. Fanourakis, et al.

    PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector concept was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 × 10 cm2 area prototypes and a 20 × 20 cm2 prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.


  • Open Access

    Gadolinium oxide nanoparticles as a multimodal contrast enhancement agent for pre-clinical proton imaging

    by Matthias Würl, Grigory Liubchenko, Guyue Hu, Katrin Schnürle, Sebastian Meyer, Jonathan Bortfeldt, Guillaume Landry, Lukas Käsmann, Kirsten Lauber, Carlos Granja, et al.

    Orthotopic tumor models in pre-clinical translational research are becoming increasingly popular, raising the demands on accurate tumor localization prior to irradiation. This task remains challenging both in x-ray and proton computed tomography (xCT and pCT, respectively), due to the limited contrast of tumor tissue compared to the surrounding tissue. We investigate the feasibility of gadolinium oxide nanoparticles as a multimodal contrast enhancement agent for both imaging modalities. We performed proton radiographies at the experimental room of the Trento Proton Therapy Center using a MiniPIX-Timepix detector and dispersions of gadolinium oxide nanoparticles in sunflower oil with mass fractions up to 8wt%. To determine the minimum nanoparticle concentration required for the detectability of small structures, pCT images of a cylindrical water phantom with cavities of varying gadolinium oxide concentration were simulated using a dedicated FLUKA Monte Carlo framework. These findings are complemented by simulating pCT at dose levels from 80 mGy to 320 mGy of artificially modified murine xCT data, mimicking different levels of gadolinium oxide accumulation inside a fictitious tumor volume. To compare the results obtained for proton imaging to x-ray imaging, cone-beam CT images of a cylindrical PMMA phantom with cavities of dispersions of oil and gadolinium oxide nanoparticles with mass fractions up to 8wt% were acquired at a commercial pre-clinical irradiation setup. For proton radiography, considerable contrast enhancement was found for a mass fraction of 4wt%. Slightly lower values were found for the simulated pCT images at imaging doses below 200 mGy. In contrast, full detectability of small gadolinium oxide loaded structures in xCT at comparable imaging dose is already achieved for 0.5wt%. Achieving such concentrations required for pCT imaging inside a tumor volume in in-vivo experiments may be challenging, yet it might be feasible using different targeting and/or injection strategies.


  • Open Access

    Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

    by M. Lisowska, R. Aleksan, Y. Angelis, S. Aune, J. Bortfeldt, F. Brunbauer, M. Brunoldi, E. Chatzianagnostou, J. Datta, K. Dehmelt, et al.


  • Open Access

    Comparison and AI-based prediction of graph comprehension skills based on the visual strategies of first-year physics and medicine students

    by Verena Ruf, Yavuz Dinc, Stefan Küchemann, Markus Berndt, Steffen Steinert, Daniela Kugelmann, Jonathan Bortfeldt, Jörg Schreiber, Martin R. Fischer, Jochen Kuhn

    Graphical representations of data are common in many disciplines. Previous research has found that physics students appear to have better graph comprehension skills than students from social science disciplines, regardless of the task context. However, the graph comprehension skills of physics students have not yet been compared with (veterinary) medicine students, both of which are disciplines that require multiple science, technology, engineering, and mathematics (STEM) courses. This study extends previous research on this subject by exploring whether physics majors possess superior graph comprehension skills due to their study discipline. Here, participants solved 24 graph comprehension tasks across various subjects, including mathematics, physics, and medicine; these tests were conducted at the beginning and end of their first semester. Graph comprehension gain was calculated based on the percentage of correct and incorrect answers in the pretest and the post-test. In addition to these comparisons, we replicated previous research that successfully distinguished correct and incorrect solvers based on their visual behavior by using a novel machine-learning method tailored to small datasets. Through this replication of statistical analyses, we aim to ensure the reliability of adaptive learning systems in the future, regardless of data size, using the same machine-learning method. Physics and medical students were found to exhibit relatively similar graph comprehension gain; this is in contrast to previous research comparing physics and non-STEM students. Our results also revealed that both physics and medical students use similar visual strategies to solve these tasks. However, correct and incorrect solvers could be distinguished via machine-learning methods regardless of their discipline. Our research suggests that visual behavior is a good predictor of graph comprehension skills. Published by the American Physical Society 2024