Joseph M. Modrick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joseph M. Modrick has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Yusung Kim
Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, USA
6 shared publications - Edward C. Pennington
Department of Radiation Oncology, University of Iowa Hospitals and Clinics, Iowa City, Iowa
2 shared publications G Jacobson
University Of Iowa, Carver College of Medicine, Iowa City, IA
2 shared publicationsJ Bayouth
University Of Iowa, Carver College of Medicine, Iowa City, IA
2 shared publicationsJohn Dill
2 shared publications- John Michael Buatti
Department of Radiation Oncology, University of Iowa, Iowa City, USA
2 shared publications
Latest Publications
- Open Access
- 8 March 2016
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (2) , 405-426
Commissioning of a 3D image‐based treatment planning system for high‐dose‐rate brachytherapy of cervical cancer
The objective of this work is to present commissioning procedures to clinically implement a three-dimensional (3D), image-based, treatment-planning system (TPS) for high-dose-rate (HDR) brachytherapy (BT) for gynecological (GYN) cancer. The physical dimensions of the GYN applicators and their values in the virtual applicator library were varied by 0.4 mm of their nominal values. Reconstruction uncertainties of the titanium tandem and ovoids (T&O) were less than 0.4 mm on CT phantom studies and on average between 0.8-1.0 mm on MRI when compared with X-rays. In-house software, HDRCalculator, was developed to check HDR plan parameters such as independently verifying active tandem or cylinder probe length and ovoid or cylinder size, source calibration and treatment date, and differences between average Point A dose and prescription dose. Dose-volume histograms were validated using another independent TPS. Comprehensive procedures to commission volume optimization algorithms and process in 3D image-based planning were presented. For the difference between line and volume optimizations, the average absolute differences as a percentage were 1.4% for total reference air KERMA (TRAK) and 1.1% for Point A dose. Volume optimization consistency tests between versions resulted in average absolute differences in 0.2% for TRAK and 0.9 s (0.2%) for total treatment time. The data revealed that the optimizer should run for at least 1 min in order to avoid more than 0.6% dwell time changes. For clinical GYN T&O cases, three different volume optimization techniques (graphical optimization, pure inverse planning, and hybrid inverse optimization) were investigated by comparing them against a conventional Point A technique. End-to-end testing was performed using a T&O phantom to ensure no errors or inconsistencies occurred from imaging through to planning and delivery. The proposed commissioning procedures provide a clinically safe implementation technique for 3D image-based TPS for HDR BT for GYN cancer. PACS number(s): 87.55.D-
- 8 March 2016
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (2) , 405-426
Open AccessCommissioning of a 3D image‐based treatment planning system for high‐dose‐rate brachytherapy of cervical cancer
The objective of this work is to present commissioning procedures to clinically implement a three-dimensional (3D), image-based, treatment-planning system (TPS) for high-dose-rate (HDR) brachytherapy (BT) for gynecological (GYN) cancer. The physical dimensions of the GYN applicators and their values in the virtual applicator library were varied by 0.4 mm of their nominal values. Reconstruction uncertainties of the titanium tandem and ovoids (T&O) were less than 0.4 mm on CT phantom studies and on average between 0.8-1.0 mm on MRI when compared with X-rays. In-house software, HDRCalculator, was developed to check HDR plan parameters such as independently verifying active tandem or cylinder probe length and ovoid or cylinder size, source calibration and treatment date, and differences between average Point A dose and prescription dose. Dose-volume histograms were validated using another independent TPS. Comprehensive procedures to commission volume optimization algorithms and process in 3D image-based planning were presented. For the difference between line and volume optimizations, the average absolute differences as a percentage were 1.4% for total reference air KERMA (TRAK) and 1.1% for Point A dose. Volume optimization consistency tests between versions resulted in average absolute differences in 0.2% for TRAK and 0.9 s (0.2%) for total treatment time. The data revealed that the optimizer should run for at least 1 min in order to avoid more than 0.6% dwell time changes. For clinical GYN T&O cases, three different volume optimization techniques (graphical optimization, pure inverse planning, and hybrid inverse optimization) were investigated by comparing them against a conventional Point A technique. End-to-end testing was performed using a T&O phantom to ensure no errors or inconsistencies occurred from imaging through to planning and delivery. The proposed commissioning procedures provide a clinically safe implementation technique for 3D image-based TPS for HDR BT for GYN cancer. PACS number(s): 87.55.D-
- Open Access
- 8 November 2014
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 15 (6) , 240-246
Bladder and rectum dose estimations on digitized radiographs for vaginal brachytherapy after hysterectomy
- 8 November 2014
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 15 (6) , 240-246
Open AccessBladder and rectum dose estimations on digitized radiographs for vaginal brachytherapy after hysterectomy
- 1 October 2013
- Vol. 20 (5) , 6907-12
First 100 cases at a low volume prostate brachytherapy institution: learning curve and the importance of continuous quality improvement.
We report the first 100 patients who underwent prostate brachytherapy as monotherapy with 125I at an institution with moderate volume radical prostatectomy but low volume brachytherapy (<2 cases per month). Learning curve and quality improvement was assessed by way of achieving prescription dose targets. From May 2002 to August 2006, 100 patients underwent prostate 125I brachytherapy monotherapy via preplanned approach. Preoperative planned dose to 100% of prostate gland (D100) was 145 Gy and postoperative confirmed dose was assessed by computed tomography. The cohort was divided into quartiles and recurrence was assessed using Kaplan-Meier analysis. Patient quartiles were of similar age and Gleason grade, while PSA was slightly higher in the first group. Postoperative D90 increased after the first quartile (p = < 0.0001) reaching targeted values. Kaplan-Meier survival analysis revealed that 5 year recurrence-free survivals by Phoenix definition was 96%-100% in all groups while by ASTRO definition there was a decrease in recurrence for later cases. At our low volume institution during the first 100 brachytherapy cases, a learning curve for radiation dosimetry was evident, which improved after 25 patients. Preplanned dose-volume parameters were adjusted, enabling the achievement of post-implant goals emphasizing the importance of continuous quality improvement. Although recurrence data is limited by sample size and moderate follow up, there was a discrepancy between the Phoenix and ASTRO definition when evaluating recurrence.
- 1 October 2013
- Vol. 20 (5) , 6907-12
First 100 cases at a low volume prostate brachytherapy institution: learning curve and the importance of continuous quality improvement.
We report the first 100 patients who underwent prostate brachytherapy as monotherapy with 125I at an institution with moderate volume radical prostatectomy but low volume brachytherapy (<2 cases per month). Learning curve and quality improvement was assessed by way of achieving prescription dose targets. From May 2002 to August 2006, 100 patients underwent prostate 125I brachytherapy monotherapy via preplanned approach. Preoperative planned dose to 100% of prostate gland (D100) was 145 Gy and postoperative confirmed dose was assessed by computed tomography. The cohort was divided into quartiles and recurrence was assessed using Kaplan-Meier analysis. Patient quartiles were of similar age and Gleason grade, while PSA was slightly higher in the first group. Postoperative D90 increased after the first quartile (p = < 0.0001) reaching targeted values. Kaplan-Meier survival analysis revealed that 5 year recurrence-free survivals by Phoenix definition was 96%-100% in all groups while by ASTRO definition there was a decrease in recurrence for later cases. At our low volume institution during the first 100 brachytherapy cases, a learning curve for radiation dosimetry was evident, which improved after 25 patients. Preplanned dose-volume parameters were adjusted, enabling the achievement of post-implant goals emphasizing the importance of continuous quality improvement. Although recurrence data is limited by sample size and moderate follow up, there was a discrepancy between the Phoenix and ASTRO definition when evaluating recurrence.
- 6 June 2013
- Published by Wiley in Medical Physics
- Vol. 40 (6) , 157
SU-E-J-36: Development of a Low Cost, Easily-Made, Interchangeable, Prostate Brachytherapy Phantom for Multi-Imaging Guidance Using Ultrasound, CT and MRI
- 6 June 2013
- Published by Wiley in Medical Physics
- Vol. 40 (6) , 157
SU-E-J-36: Development of a Low Cost, Easily-Made, Interchangeable, Prostate Brachytherapy Phantom for Multi-Imaging Guidance Using Ultrasound, CT and MRI
- Open Access
- 1 January 2013
- Published by Termedia Sp. z.o.o. in Journal of Contemporary Brachytherapy
- Vol. 2 (2) , 101-109
High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes
Purpose : To evaluate conventional brachytherapy (BT) plans using dose-volume parameters and high resolution (3 Tesla) MRI datasets, and to quantify dosimetric benefits and limitations when MRI-guided, conformal BT (MRIG-CBT) plans are generated. Material and methods : Fifty-five...
- 1 January 2013
- Published by Termedia Sp. z.o.o. in Journal of Contemporary Brachytherapy
- Vol. 2 (2) , 101-109
Open AccessHigh resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes
Purpose : To evaluate conventional brachytherapy (BT) plans using dose-volume parameters and high resolution (3 Tesla) MRI datasets, and to quantify dosimetric benefits and limitations when MRI-guided, conformal BT (MRIG-CBT) plans are generated. Material and methods : Fifty-five...
- 1 July 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 80 (3) , 947-955
Evaluation of Artifacts and Distortions of Titanium Applicators on 3.0-Tesla MRI: Feasibility of Titanium Applicators in MRI-Guided Brachytherapy for Gynecological Cancer
- 1 July 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 80 (3) , 947-955
Evaluation of Artifacts and Distortions of Titanium Applicators on 3.0-Tesla MRI: Feasibility of Titanium Applicators in MRI-Guided Brachytherapy for Gynecological Cancer
- 1 June 2008
- Published by Wiley in Medical Physics
- Vol. 35 (6) , 2970
TH-C-AUD A-06: Evaluation of 3 Tesla MR Image Distortion and Artifacts in a Titanium Applicator Presence: Toward 3T MRI Guided HDR Brachytherapy for Cervical Cancer
- 1 June 2008
- Published by Wiley in Medical Physics
- Vol. 35 (6) , 2970
TH-C-AUD A-06: Evaluation of 3 Tesla MR Image Distortion and Artifacts in a Titanium Applicator Presence: Toward 3T MRI Guided HDR Brachytherapy for Cervical Cancer
- 1 November 2006
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 66 (3) , 906-912
Optimal number of beams for stereotactic body radiotherapy of lung and liver lesions
- 1 November 2006
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 66 (3) , 906-912
Optimal number of beams for stereotactic body radiotherapy of lung and liver lesions
- 22 November 2004
- Published by Wiley in Medical Physics
- Vol. 31 (12) , 3393-3405
Distortions induced by radioactive seeds into interstitial brachytherapy dose distributions
In a previous article, we presented development and verification of an integral transport equation‐based deterministic algorithm for computing three‐dimensional brachytherapy dose distributions. Recently, we have included fluorescence radiation physics and parallel computation to the standing algorithms so that we can compute dose distributions for a large set of seeds without resorting to the superposition methods. The introduction of parallel computing capability provided a means to compute the dose distribution for multiple seeds in a simultaneous manner. This provided a way to study strong heterogeneity and shadow effects induced by the presence of multiple seeds in an interstitial brachytherapy implant. This article presents the algorithm for computing fluorescence radiation, algorithm for parallel computing, and display results for an 81‐seed implant that has a perfect and imperfect lattice. The dosimetry data for a single model 6711 seeds is presented for verification and heterogeneity factor computations using simultaneous and superposition techniques are presented.
- 22 November 2004
- Published by Wiley in Medical Physics
- Vol. 31 (12) , 3393-3405
Distortions induced by radioactive seeds into interstitial brachytherapy dose distributions
In a previous article, we presented development and verification of an integral transport equation‐based deterministic algorithm for computing three‐dimensional brachytherapy dose distributions. Recently, we have included fluorescence radiation physics and parallel computation to the standing algorithms so that we can compute dose distributions for a large set of seeds without resorting to the superposition methods. The introduction of parallel computing capability provided a means to compute the dose distribution for multiple seeds in a simultaneous manner. This provided a way to study strong heterogeneity and shadow effects induced by the presence of multiple seeds in an interstitial brachytherapy implant. This article presents the algorithm for computing fluorescence radiation, algorithm for parallel computing, and display results for an 81‐seed implant that has a perfect and imperfect lattice. The dosimetry data for a single model 6711 seeds is presented for verification and heterogeneity factor computations using simultaneous and superposition techniques are presented.