ZMZhenghui Mi

Zhenghui Mi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhenghui Mi has a total of 133 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Numerical simulation and vertical test of conduction-cooled 1.3 GHz SRF cavity

    by Xiao Liu, Zhengze Chang, Jianrong Zhou, Lingxi Ye, Peng Sha, Jinxin Yu, Yuhao Liu, Zhihang Zhang, Miaofu Xu, Zhenghui Mi, et al.

  • Open Access

    Design and validation of the 324 MHz double-spoke cavity tuner for CSNS-II

    by M. Liu, Z. Mi, W. Pan, R. Ge, F. He, W. Zhou, C. Zhang, T. Sun

    The CSNS-II linac will employ twenty 324 MHz double-spoke superconducting cavities, which work on pulsed operating mode. We report the design and experimental validation of a combined coarse-fine tuner that pairs a wedge-driven stepper motor with dual piezoelectric actuators. The tuner architecture is compensating Lorentz-force detuning, beam loading, helium pressure fluctuations, and microphonics, providing a fast-tuning allowance above 500 Hz. An axial stiffness model was built, and the stiffness of each component was simulated using COMSOL. The tuning efficiency of the tuner was calculated to be 61.15%, yielding effective coarse and fine tuning ranges of 342 kHz and 5.25 kHz at room temperature. Integrated cavity-string tests confirm linear slow-tuner response (0.246 Hz/pulse over 12.0 kHz at 300 K; 0.255 Hz/pulse over 63 kHz at 2 K) and quantify piezo hysteresis and stroke (3.67 kHz at 300 K; 0.66 kHz at 2 K). The requirements, design, assembly integration, and testing of the tuner will be presented, and the final tuner design will fully meet the requirements of the CSNS-II double spoke cavity.


  • Open Access

    Preliminary design of a Cavity Tuner for Superconducting Radio-Frequency Cavity

    by Ming Liu, Jiyuan Zhai, Feisi He, Zhenghui Mi

    This paper introduces a newly designed cavity tuner for superconducting radio-frequency (SRF) cavity. Aiming to overcome the drawbacks of traditional tuning systems, like the limited tuning range of piezoelectric tuner and the low-speed tuning of stepper-motor-based tuner, this novel tuner is crafted to improve SRF cavity performance and stability via efficient and accurate frequency tuning. The design encompasses several key elements. The cavity structure includes a commonly used 1.3 GHz single-cell superconducting cavity and a room-temperature coaxial tuner cavity. The coupling mechanism between the two cavities, along with the coupling window design, ensures effective energy transfer while minimizing losses. The mechanical tuning system, driven by electromagnetic coils, enables precise adjustments, and the cooling mechanisms for both cavities guarantee stable operation. Functioning by coupling an external resonant cavity to the superconducting one, this tuner can adjust frequencies through mechanical or electromagnetic methods. It realizes rapid tuning, with a speed much faster than traditional mechanical tuner, high-precision tuning down to the sub-mHz level, and a wide tuning range covering a broader frequency spectrum. Theoretical analysis and simulations verify that the tuner can remarkably enhance tuning speed, precision, and range. It also has distinct advantages such as a simplified structure, which reduces manufacturing and maintenance complexity, and enhanced reliability due to its non-contact tuning operation. In particle accelerators, this cavity tuner holds great potential. It represents a significant step forward in superconducting accelerator technology, offering a novel way to optimize the performance and stability of SRF cavity.

  • Error Analysis of Vertical Test for CEPC 650 MHz Superconducting Radio-frequency Cavity

    by Lingxi Ye, Peng Sha, Zhenghui Mi, Feisi He, Jiyuan Zhai

    Hundreds of 650 MHz superconducting radio-frequency (SRF) cavities with high intrinsic quality factor (Q0) and accelerating gradient (Eacc) will be adopted for Circular Electron Positron Collider (CEPC). The values of Q0 and Eacc are obtained during vertical test at 2.0 K. Hence, high accuracy of vertical test is essential for evaluating the performance of SRF cavity. The 650 MHz SRF cavities achieved very high Q0 (6 × 1010) and Eacc (40 MV/m) during the vertical test. In our study, the error analysis of vertical test was conducted in the scalar case, in order to achieve high accuracy. The uncertainties of vertical test were obtained through calculation, which was approximately 3% for Eacc and less than 5% for Q0. This result was reasonable and acceptable.


  • Development of vertical test stand for SRF cavities at PAPS

    by Lingxi Ye, Peng Sha, Zhenghui Mi, Qunyao Wang, Feisi He, Rui Ge, Weimin Pan

    The vertical test stand (VTS) plays a crucial role in evaluating the performance of superconducting radio-frequency (SRF) cavities. The VTS at the Platform of Advanced Photon Source Technology R&D (PAPS) has been developed by the Institute of High Energy Physics, Chinese Academy of Sciences (IHEP). In this paper, the digitalization (based on Field Programmable Gate Array, FPGA) and integration functionalities of VTS was carried out, which simplified the vertical test and improved efficiency greatly. Several vertical tests have been conducted at this upgraded VTS successfully, which adopted digital self-excited loop (SEL) and Experimental Physics and Industrial Control System (EPICS).


  • Application of superconducting cavity tuner in dark photon dark matter search

    by Ming Liu, Zhenghui Mi, Peng Sha, Weimin Pan, Jing Shu, Zhenxing Tang, Chunlong Li, Feisi He, Lingxi Ye


  • Development of a New Vacuum Furnace and Its Application for 650 MHz Superconducting Cavities

    by Baiqi Liu, Peng Sha, Weimin Pan, Song Jin, Lingxi Ye, Zhenghui Mi, Chao Dong, Jiyuan Zhai, Feisi He

    A new vacuum furnace has been developed at the Institute of High Energy Physics, Chinese Academy of Sciences (IHEP), which was dedicated to processing superconducting radio-frequency (SRF) cavities. It was integrated and commissioned in 2021, and then used for high-temperature annealing, nitrogen doping, and medium-temperature (mid-T) furnace baking, et c. The nitrogen doping of two 650 MHz SRF cavities was conducted at this vacuum furnace, followed by light electro-polishing (EP). Then, the two cavities nitrogen doped both demonstrated a higher intrinsic quality factor ( Q 0 ) than baseline during the vertical test (@ 2.0 K), which reached 6.5 × 10 10 and 7.2 × 10 10 at 20 MV/m, respectively. However, the maximum accelerating gradient ( E acc ) was reduced considerably for both 650 MHz SRF cavities. Thus, the process of nitrogen doping could enhance the Q 0 of 650 MHz SRF cavities at the expense of E acc . In general, nitrogen doping may be advocated for continuous-wave (CW) accelerators, which are usually operated at a medium gradient.


  • Open Access

    Quality Factor Enhancement of 650 MHz Superconducting Radio-Frequency Cavity for CEPC

    by Peng Sha, Weimin Pan, Jiyuan Zhai, Zhenghui Mi, Song Jin, Baiqi Liu, Chao Dong, Feisi He, Lingxi Ye, Xiangcong He, et al.

    Medium-temperature (mid-T) furnace baking was conducted at 650 MHz superconducting radio-frequency (SRF) cavity for circular electron positron collider (CEPC), which enhanced the cavity unloaded quality factor (Q0) significantly. In the vertical test (2.0 K), Q0 of 650 MHz cavity reached 6.4 × 1010 at 30 MV/m, which is remarkably high at this unexplored frequency. Additionally, the cavity quenched at 31.2 MV/m finally. There was no anti-Q-slope behavior after mid-T furnace baking, which is characteristic of 1.3 GHz cavities. The microwave surface resistance (RS) was also studied, which indicated both very low Bardeen–Cooper–Schrieffer (BCS) and residual resistance. The recipe of cavity process in this paper is simplified and easy to duplicate, which may benefit the SRF community.


  • Open Access

    Development and Vertical Tests of CEPC 650-MHz Single-Cell Cavities with High Gradient

    by Song Jin, Peng Sha, Weimin Pan, Jiyuan Zhai, Zhenghui Mi, Feisi He, Chao Dong, Lingxi Ye, Xiangcong He

    A circular electron positron collider (CEPC) will adopt hundreds of 650-MHz superconducting cavities with high quality factor (Q) and accelerating gradient (Eacc). Two 650-MHz single-cell cavities made of fine-grain niobium were first treated via buffered chemical polishing (BCP), which was easy and convenient. However, the vertical test results could not meet the specification of the CEPC (4 × 1010 at 22 MV/m). Therefore, electro-polishing (EP) of 650-MHz single-cell cavities was conducted, which was complicated but remarkably effective. Both 650-MHz single-cell cavities achieved state-of-the-art gradients of 35 MV/m after the EP process, which is extremely high for large elliptical cavities (frequency < 1 GHz). One cavity achieved an intrinsic quality factor (Q0) of 4.5 × 1010 at 22.0 MV/m, which was higher than the CEPC spec. The other cavity obtained a lower Q0 of 3.4 × 1010 at 22.0 MV/m, which may have resulted from the cancellation of high-temperature annealing.