Daniel Punzet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel Punzet has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Georg Rose
Otto-von-Guericke-University Magdeburg
2 shared publications Tim Pfeiffer
Otto-von-Guericke-University Magdeburg
2 shared publications- Afsaneh Nematpour
DISTAL—Department of Agricultural and Food Sciences, Alma Mater Studiorum—Università di Bologna, Viale Fanin 44, 40127 Bologna, Italy
1 shared publication - Bahaa Alsawalhi
Department of Radiology and Nuclear Medicine, University Hospital Magdeburg and Medical Faculty of Otto-von-Guericke University, 39120 Magdeburg, Germany
1 shared publication - Daniel Behme
Clinic for Neuroradiology, Medical Faculty, Otto-von-Guericke University Magdeburg, 39120 Magdeburg, Germany
1 shared publication - Dennis Kupitz
Department for Radiology and Nuclear Medicine University Hospital Magdeburg Magdeburg Germany
1 shared publication
Latest Publications
- Open Access
- 8 July 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135032
A joint registration and extrapolation method for cone beam computed tomography volume of interest imaging
The high patient dose applied during acquisition of C-arm based cone beam computed tomography (CBCT) scans limits the applicability of this imaging technique. Acquisition of only a region-of-interest can decrease the dose significantly. However, reconstruction from such truncated projection data can lead to severe artifacts in the tomographic image. For typical usages of C-arm based CBCT however, there often exists a prior computed tomography or CBCT scan of the patient. The proposed method enables the incorporation of such priors into the reconstruction process by jointly registering and extrapolating the prior to the limited data acquisition scenario by maximizing consistency conditions across thusly extended projections. Results show improved image quality over simple heuristic extrapolation methods typically used in practice. The proposed method can be regarded as a novel hybrid registration and extrapolation algorithm similar to established digitally reconstructed radiographs-based registration methods, but unlike these, working on mutually disjoint regions of the projection data.
- 8 July 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135032
Open AccessA joint registration and extrapolation method for cone beam computed tomography volume of interest imaging
The high patient dose applied during acquisition of C-arm based cone beam computed tomography (CBCT) scans limits the applicability of this imaging technique. Acquisition of only a region-of-interest can decrease the dose significantly. However, reconstruction from such truncated projection data can lead to severe artifacts in the tomographic image. For typical usages of C-arm based CBCT however, there often exists a prior computed tomography or CBCT scan of the patient. The proposed method enables the incorporation of such priors into the reconstruction process by jointly registering and extrapolating the prior to the limited data acquisition scenario by maximizing consistency conditions across thusly extended projections. Results show improved image quality over simple heuristic extrapolation methods typically used in practice. The proposed method can be regarded as a novel hybrid registration and extrapolation algorithm similar to established digitally reconstructed radiographs-based registration methods, but unlike these, working on mutually disjoint regions of the projection data.
- Open Access
- 16 August 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (8) , 838
Effect of Spectral Filtering and Segmental X-ray Tube Current Switch-Off on Interventionalist’s Scatter Exposure during CT Fluoroscopy
Dose optimization in computed tomography (CT) is crucial, especially in CT fluoroscopy (fluoro-CT) used for real-time navigation, affecting both patient and operator safety. This study evaluated the impact of spectral X-ray filtering using a tin filter (Sn filter), and a method called partial-angle computed tomography (PACT), which involves segmentally switching off the X-ray tube current at the ambient dose rate at the interventional radiologist’s (IR) position. Measurements were taken at two body regions (upper body: head/neck; lower body: lower legs/feet) using a 120 kV X-ray tube voltage, 3 × 5.0 mm CT collimation, 0.5 s rotation speed, and X-ray tube currents of 43 Eff.mAs (without Sn filter) and 165 Eff.mAs (with Sn filter). The study found significant dose reductions in both body regions when using the Sn filter and PACT together. For instance, in the upper body region, the combination protocol reduced from 11.8 µSv/s to 6.1 µSv/s (p < 0.0001) compared to the protocol without using these features. Around 8% of the reduction (about 0.5 µSv/s) is attributed to the Sn filter (p = 0.0005). This approach demonstrates that using the Sn filter along with PACT effectively minimizes radiation exposure for the IR, particularly protecting areas like the head/neck, which can only be insufficiently covered by (standard) radiation protection material.- 16 August 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (8) , 838
Open AccessEffect of Spectral Filtering and Segmental X-ray Tube Current Switch-Off on Interventionalist’s Scatter Exposure during CT Fluoroscopy
Dose optimization in computed tomography (CT) is crucial, especially in CT fluoroscopy (fluoro-CT) used for real-time navigation, affecting both patient and operator safety. This study evaluated the impact of spectral X-ray filtering using a tin filter (Sn filter), and a method called partial-angle computed tomography (PACT), which involves segmentally switching off the X-ray tube current at the ambient dose rate at the interventional radiologist’s (IR) position. Measurements were taken at two body regions (upper body: head/neck; lower body: lower legs/feet) using a 120 kV X-ray tube voltage, 3 × 5.0 mm CT collimation, 0.5 s rotation speed, and X-ray tube currents of 43 Eff.mAs (without Sn filter) and 165 Eff.mAs (with Sn filter). The study found significant dose reductions in both body regions when using the Sn filter and PACT together. For instance, in the upper body region, the combination protocol reduced from 11.8 µSv/s to 6.1 µSv/s (p < 0.0001) compared to the protocol without using these features. Around 8% of the reduction (about 0.5 µSv/s) is attributed to the Sn filter (p = 0.0005). This approach demonstrates that using the Sn filter along with PACT effectively minimizes radiation exposure for the IR, particularly protecting areas like the head/neck, which can only be insufficiently covered by (standard) radiation protection material. - 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (1) , 113-120
Development and Evaluation of a Prototype of Shape-Adaptable and Portable All-Digital PET System for In-Lab and In-Field Plant Imaging
Positron Emission Tomography (PET) is increasingly employed for precision monitoring in plant science, as it is a non-invasive technique for the quantitative analysis of the functional mechanisms of plant metabolism. When exported to digital agronomy in combination with qualitative detection, PET has the potential to drive the sustainable management of chemical fertilizers. Such a translational approach requires a transition from controlled in-lab to natural in-field PET imaging. We report a novel portable and shape-adaptable digital plant PET system based on the Multi Voltage Threshold digital readout, with an extendable transverse Field of View (FOV) ranging between 80 mm and 120 mm. The system reaches a peak sensitivity up to (16.94 ± 0.01)% and (9.12 ± 0.01)% in closed and maximally opened FOV configuration, respectively. Image quality has been tested with a dedicated plant phantom imaging. We verified the ability of the prototype to perform plant PET imaging: in-lab with Zea mays L . sprouts under heat stress, and in-field with Triticum aestivum sprouts under drougt stress.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (1) , 113-120
Development and Evaluation of a Prototype of Shape-Adaptable and Portable All-Digital PET System for In-Lab and In-Field Plant Imaging
Positron Emission Tomography (PET) is increasingly employed for precision monitoring in plant science, as it is a non-invasive technique for the quantitative analysis of the functional mechanisms of plant metabolism. When exported to digital agronomy in combination with qualitative detection, PET has the potential to drive the sustainable management of chemical fertilizers. Such a translational approach requires a transition from controlled in-lab to natural in-field PET imaging. We report a novel portable and shape-adaptable digital plant PET system based on the Multi Voltage Threshold digital readout, with an extendable transverse Field of View (FOV) ranging between 80 mm and 120 mm. The system reaches a peak sensitivity up to (16.94 ± 0.01)% and (9.12 ± 0.01)% in closed and maximally opened FOV configuration, respectively. Image quality has been tested with a dedicated plant phantom imaging. We verified the ability of the prototype to perform plant PET imaging: in-lab with Zea mays L . sprouts under heat stress, and in-field with Triticum aestivum sprouts under drougt stress.
- 28 May 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11072, 37
GCC-based extrapolation of truncated CBCT data with dimensionality-reduced extrapolation models
A typical incomplete data problem arising in cone-beam computed tomography (CBCT) occurs when an object is either too large to be projected onto the detector or is deliberately only projected in parts. This problem is called truncation. Tomographic images reconstructed from truncated projection data can be severely impaired by image artifacts depending on the degree of truncation. A typical strategy to counter this is to extend the projection data by some smooth extrapolation. In order to accurately approximate the shape of the scanned object outside of the volume of interest (VOI), we previously presented a method which fits an extrapolation model to the truncated data by minimizing an error function based on the Grangeat consistency condition (GCC). In this work we propose a method of reducing the complexity of the extrapolation by making use of the 0th image moments of the truncated projection data.
- 28 May 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11072, 37
GCC-based extrapolation of truncated CBCT data with dimensionality-reduced extrapolation models
A typical incomplete data problem arising in cone-beam computed tomography (CBCT) occurs when an object is either too large to be projected onto the detector or is deliberately only projected in parts. This problem is called truncation. Tomographic images reconstructed from truncated projection data can be severely impaired by image artifacts depending on the degree of truncation. A typical strategy to counter this is to extend the projection data by some smooth extrapolation. In order to accurately approximate the shape of the scanned object outside of the volume of interest (VOI), we previously presented a method which fits an extrapolation model to the truncated data by minimizing an error function based on the Grangeat consistency condition (GCC). In this work we propose a method of reducing the complexity of the extrapolation by making use of the 0th image moments of the truncated projection data.