Johann Wannenburg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Johann Wannenburg has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Philippus Stephanus Heyns
Centre for Asset Integrity Management, Department of Mechanical and Aeronautical Engineering, University of Pretoria, Pretoria, South Africa
3 shared publications A. Olivier
Department of Companion Animal Clinical Studies, Faculty of Veterinary Science, University of Pretora, Onderstepoort, South Africa
1 shared publicationA.D. Raath
1 shared publicationAnton D. Raath
1 shared publicationC. Smith
1 shared publicationDe Wet Strydom
BKS Advantech Pty. Ltd. (South Africa)
1 shared publication
Latest Publications
- Open Access
- 12 May 2025
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 146
Using proper orthogonal decomposition for data-driven model error correction for heat conduction problems with uncertain boundary conditions
- 12 May 2025
- Published by Elsevier in Applied Mathematical Modelling
- Vol. 146
Open AccessUsing proper orthogonal decomposition for data-driven model error correction for heat conduction problems with uncertain boundary conditions
- Open Access
- 5 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (12) , 6839-6852
Body Sensor Network for Mobile Health Monitoring, a Diagnosis and Anticipating System
A system capable of mobile health monitoring was designed and implemented from the first principles. The system is capable of measuring vital physiological parameters, interpret the measured signals, and provide a sense of monitoring and biofeedback to the user. In the case, a medical emergency is detected notifications are sent to a medical tedam for the analysis. The system was designed through the investigation of various biosignal extraction methods. An optical pulse oximeter sensor was designed along with the required software algorithms. The photoplethysmographic signals were extracted and used to calculate heart rate, saturation of oxygen, and pulse transits time. The pulse transit time was utilized in the estimation of continuous blood pressure measurement. The pulse oximetry implementation applies reflectance-based sensing on the user's fingertip and palm. Skin temperature is also measurable through the use of a digital temperature sensor. The system is capable of providing feedback to the user by means of a smartphone application receiving data from the device through Bluetooth. The measurement of the proposed physiological parameters were successfully measured with the appropriate degree of accuracy required by medical standards. The system is capable of health monitoring through accurate measurements, providing the user with feedback and successfully identifying medical stress resulting in the sending of a notification to a medical doctor.
- 5 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (12) , 6839-6852
Open AccessBody Sensor Network for Mobile Health Monitoring, a Diagnosis and Anticipating System
A system capable of mobile health monitoring was designed and implemented from the first principles. The system is capable of measuring vital physiological parameters, interpret the measured signals, and provide a sense of monitoring and biofeedback to the user. In the case, a medical emergency is detected notifications are sent to a medical tedam for the analysis. The system was designed through the investigation of various biosignal extraction methods. An optical pulse oximeter sensor was designed along with the required software algorithms. The photoplethysmographic signals were extracted and used to calculate heart rate, saturation of oxygen, and pulse transits time. The pulse transit time was utilized in the estimation of continuous blood pressure measurement. The pulse oximetry implementation applies reflectance-based sensing on the user's fingertip and palm. Skin temperature is also measurable through the use of a digital temperature sensor. The system is capable of providing feedback to the user by means of a smartphone application receiving data from the device through Bluetooth. The measurement of the proposed physiological parameters were successfully measured with the appropriate degree of accuracy required by medical standards. The system is capable of health monitoring through accurate measurements, providing the user with feedback and successfully identifying medical stress resulting in the sending of a notification to a medical doctor.
- 1 January 2010
- Published by Inderscience Publishers in International Journal of Vehicle Systems Modelling and Testing
- Vol. 5 (1) , 72
An overview of numerical methodologies for durability assessment of vehicle and transport structures
Numerical methodologies for assessing the durability of vehicle and transport structures are reviewed. These methodologies are mapped in terms of a framework that emphasises the relationships among them. Load inputs are obtained from either measurements or simulation. These loads are used as inputs into stress analyses, which may be either quasi-static or dynamic, and either in the time domain or in the frequency domain. The outputs of these analyses can be then used in fatigue analyses. The advantages and disadvantages of each method are analysed. A case study is described to demonstrate the insights gained from the mapping framework.
- 1 January 2010
- Published by Inderscience Publishers in International Journal of Vehicle Systems Modelling and Testing
- Vol. 5 (1) , 72
An overview of numerical methodologies for durability assessment of vehicle and transport structures
Numerical methodologies for assessing the durability of vehicle and transport structures are reviewed. These methodologies are mapped in terms of a framework that emphasises the relationships among them. Load inputs are obtained from either measurements or simulation. These loads are used as inputs into stress analyses, which may be either quasi-static or dynamic, and either in the time domain or in the frequency domain. The outputs of these analyses can be then used in fatigue analyses. The advantages and disadvantages of each method are analysed. A case study is described to demonstrate the insights gained from the mapping framework.
- 1 October 2009
- Published by Elsevier in International Journal of Fatigue
- Vol. 31 (10) , 1541-1549
Application of a fatigue equivalent static load methodology for the numerical durability assessment of heavy vehicle structures
- 1 October 2009
- Published by Elsevier in International Journal of Fatigue
- Vol. 31 (10) , 1541-1549
Application of a fatigue equivalent static load methodology for the numerical durability assessment of heavy vehicle structures
- 1 January 2008
- Published by Inderscience Publishers in International Journal of Vehicle Design
- Vol. 47 (1/2/3/4) , 269
The derivation of structural usage profiles for vehicles from failure statistics
A methodology is presented to derive a statistical fatigue loading profile of the total population of users of a vehicle model, from failure data recorded on the same or a previous model. The method is based on fitting a bivariate probability density function on normalised failure data. This is radically more economic than existing methods. Reasonable accuracy could be achieved, even if the failures represent only a small fraction of the total population. The two-parameter usage profile determined in this way offers a powerful approach to predict failures or derive statistically based durability test or design requirements.
- 1 January 2008
- Published by Inderscience Publishers in International Journal of Vehicle Design
- Vol. 47 (1/2/3/4) , 269
The derivation of structural usage profiles for vehicles from failure statistics
A methodology is presented to derive a statistical fatigue loading profile of the total population of users of a vehicle model, from failure data recorded on the same or a previous model. The method is based on fitting a bivariate probability density function on normalised failure data. This is radically more economic than existing methods. Reasonable accuracy could be achieved, even if the failures represent only a small fraction of the total population. The two-parameter usage profile determined in this way offers a powerful approach to predict failures or derive statistically based durability test or design requirements.
- 1 February 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4837, 272-283
Structural design of the Southern African Large Telescope
The Southern African Large Telescope (SALT), being erected in Sutherland, South Africa, will be the largest single optical telescope in the southern hemisphere, and the 4th largest telescope in the world, when it is completed in late 2004. The SALT design is based on the Hobby-Eberly Telescope (HET). Deviations from the HET design with respect to the telescope structure, primary mirror truss and tracker beam structure are presented in this paper. Finite element models were generated to perform static, dynamic and thermal analyses on the structures. Despite a significantly heavier payload and increased wind loading requirements, equivalent or improved stiffness characteristics were achieved, without increasing structure mass. Dynamic response analyses were performed to characterize the maximum deflections under dynamic wind loading. Automation of the truss design process, which included the control of the 3-D CAD software, the finite element software, as well as CAM software, with a central computer program, allowed the generation of a full 3-D CAD model, as well as CAM inputs, of a structurally optimized truss, within a few days. Extensive analyses, including Monte Carlo simulations, as well as experimentation, were performed to ensure linear temperature-displacement response of the truss. A methodology was developed, using the complete finite element model, to calculate mirror corrections required to correct for lower order deformations of the primary mirror due to temperature fluctuations in the truss.© (2003) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
- 1 February 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4837, 272-283
Structural design of the Southern African Large Telescope
The Southern African Large Telescope (SALT), being erected in Sutherland, South Africa, will be the largest single optical telescope in the southern hemisphere, and the 4th largest telescope in the world, when it is completed in late 2004. The SALT design is based on the Hobby-Eberly Telescope (HET). Deviations from the HET design with respect to the telescope structure, primary mirror truss and tracker beam structure are presented in this paper. Finite element models were generated to perform static, dynamic and thermal analyses on the structures. Despite a significantly heavier payload and increased wind loading requirements, equivalent or improved stiffness characteristics were achieved, without increasing structure mass. Dynamic response analyses were performed to characterize the maximum deflections under dynamic wind loading. Automation of the truss design process, which included the control of the 3-D CAD software, the finite element software, as well as CAM software, with a central computer program, allowed the generation of a full 3-D CAD model, as well as CAM inputs, of a structurally optimized truss, within a few days. Extensive analyses, including Monte Carlo simulations, as well as experimentation, were performed to ensure linear temperature-displacement response of the truss. A methodology was developed, using the complete finite element model, to calculate mirror corrections required to correct for lower order deformations of the primary mirror due to temperature fluctuations in the truss.© (2003) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
- Open Access
- 9 July 2001
- Published by AOSIS in Journal of the South African Veterinary Association
- Vol. 72 (4) , 217-227
The effect of frog pressure and downward vertical load on hoof wall weight-bearing and third phalanx displacement in the horse - an in vitro study : research communication
A shoe was designed to combine the advantages of a reverse shoe and an adjustable heart bar shoe in the treatment of chronic laminitis. This reverse even frog pressure (REFP) shoe applies pressure uniformly over a large area of the frog solar surface. Pressure is applied vertically upward parallel to the solar surface of the frog and can be increased or decreased as required. Five clinically healthy horses were humanely euthanased and their dismem-bered forelimbs used in an in vitro study. Frog pressure was measured by strain gauges applied to the ground surface of the carrying tab portion of the shoe. A linear variable distance transducer (LVDT) was inserted into a hole drilled in the dorsal hoof wall. The LVDT measured movement of the third phalanx (P3) in a dorsopalmar plane relative to the dorsal hoof wall. The vertical component of hoof wall compression was measured by means of unidirectional strain gauges attached to the toe, quarter and heel of the medial hoof wall of each specimen. The entire limb was mounted vertically in a tensile testing machine and submitted to vertical downward compressive forces of 0 to 2500 Nat a rate of 5 cm/minute. The effects of increasing frog pressure on hoof wall weight-bearing and third phalanx movement within the hoof were determined. Each specimen was tested with the shoe under the following conditions: zero frog pressure; frog pressure used to treat clinical cases of chronic laminitis (7 N-cm); frog pressure clinically painful to the horse as determined prior to euthanasia; frog pressure just alleviating this pain. The specimens were also tested after shoe removal. Total weight-bearing on the hoof wall at zero frog pressure was used as the basis for comparison. Pain-causing and pain-alleviating frog pressures decreased total weight-bearing on the hoof wall (P 0.05). Frog pressure of 7 N-cm had no statistically significant effect on hoof wall weight-bearing although there was a trend for it to decrease as load increased. Before loading, the pain-causing and pain-alleviating frog pressures resulted in a palmar movement of P3 relative to the dorsal hoof wall compared to the position of P3 at zero frog pressure (P 0.05). This difference remained statistically significant up to 1300 Nload. At higher loads, the position of P3 did not differ significantly for the different frog pressures applied. It is concluded that increased frog pressure using the REFP shoe decreases total hoof wall weight-bearing and causes palmar movement of P3 at low weight-bearing loads. Without a shoe the toe and quarter hoof wall compression remained more constant and less in magnitude, than with a shoe.
- 9 July 2001
- Published by AOSIS in Journal of the South African Veterinary Association
- Vol. 72 (4) , 217-227
Open AccessThe effect of frog pressure and downward vertical load on hoof wall weight-bearing and third phalanx displacement in the horse - an in vitro study : research communication
A shoe was designed to combine the advantages of a reverse shoe and an adjustable heart bar shoe in the treatment of chronic laminitis. This reverse even frog pressure (REFP) shoe applies pressure uniformly over a large area of the frog solar surface. Pressure is applied vertically upward parallel to the solar surface of the frog and can be increased or decreased as required. Five clinically healthy horses were humanely euthanased and their dismem-bered forelimbs used in an in vitro study. Frog pressure was measured by strain gauges applied to the ground surface of the carrying tab portion of the shoe. A linear variable distance transducer (LVDT) was inserted into a hole drilled in the dorsal hoof wall. The LVDT measured movement of the third phalanx (P3) in a dorsopalmar plane relative to the dorsal hoof wall. The vertical component of hoof wall compression was measured by means of unidirectional strain gauges attached to the toe, quarter and heel of the medial hoof wall of each specimen. The entire limb was mounted vertically in a tensile testing machine and submitted to vertical downward compressive forces of 0 to 2500 Nat a rate of 5 cm/minute. The effects of increasing frog pressure on hoof wall weight-bearing and third phalanx movement within the hoof were determined. Each specimen was tested with the shoe under the following conditions: zero frog pressure; frog pressure used to treat clinical cases of chronic laminitis (7 N-cm); frog pressure clinically painful to the horse as determined prior to euthanasia; frog pressure just alleviating this pain. The specimens were also tested after shoe removal. Total weight-bearing on the hoof wall at zero frog pressure was used as the basis for comparison. Pain-causing and pain-alleviating frog pressures decreased total weight-bearing on the hoof wall (P 0.05). Frog pressure of 7 N-cm had no statistically significant effect on hoof wall weight-bearing although there was a trend for it to decrease as load increased. Before loading, the pain-causing and pain-alleviating frog pressures resulted in a palmar movement of P3 relative to the dorsal hoof wall compared to the position of P3 at zero frog pressure (P 0.05). This difference remained statistically significant up to 1300 Nload. At higher loads, the position of P3 did not differ significantly for the different frog pressures applied. It is concluded that increased frog pressure using the REFP shoe decreases total hoof wall weight-bearing and causes palmar movement of P3 at low weight-bearing loads. Without a shoe the toe and quarter hoof wall compression remained more constant and less in magnitude, than with a shoe.
- 1 March 1997
- Published by Elsevier in International Journal of Pressure Vessels and Piping
- Vol. 70 (3) , 183-195
The effect of a long post weld heat treatment on the integrity of a welded joint in a pressure vessel steel
- 1 March 1997
- Published by Elsevier in International Journal of Pressure Vessels and Piping
- Vol. 70 (3) , 183-195
The effect of a long post weld heat treatment on the integrity of a welded joint in a pressure vessel steel
- 1 October 1995
- Published by Elsevier in International Journal of Fatigue
- Vol. 17 (7) , 477-483
Remaining life analysis for a pressure vessel subjected to cyclic loads based on fracture mechanics
- 1 October 1995
- Published by Elsevier in International Journal of Fatigue
- Vol. 17 (7) , 477-483
Remaining life analysis for a pressure vessel subjected to cyclic loads based on fracture mechanics
- 1 January 1994
- Published by Elsevier in International Journal of Pressure Vessels and Piping
- Vol. 59 (1-3) , 259-269
The determination of cost-effective NDE inspection schedules for structures containing defects based on probabilistic fracture mechanics
- 1 January 1994
- Published by Elsevier in International Journal of Pressure Vessels and Piping
- Vol. 59 (1-3) , 259-269
The determination of cost-effective NDE inspection schedules for structures containing defects based on probabilistic fracture mechanics