MOMasatoshi Oba

Masatoshi Oba

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Masatoshi Oba has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Paediatric Epstein-Barr virus-associated rhabdomyolysis complicated by acute compartment syndrome treated with decompressive fasciotomy

    by Masamichi Koike, Masatoshi Oba, Koji Tanoue, Satomi Mori

    Epstein-Barr virus (EBV) is a common virus that causes paediatric rhabdomyolysis. Acute compartment syndrome is a rare complication of rhabdomyolysis that can lead to severe consequences. We report the case of a previously healthy boy in early childhood with EBV-associated rhabdomyolysis complicated by acute compartment syndrome that required decompressive fasciotomy. The patient recovered without loss of strength, sensation or range of motion. This case report aims to focus attention on serious complications such as acute compartment syndrome that can occur with common viruses.


  • An automated real‐time PCR assay for synovial fluid improves the preoperative etiological diagnosis of periprosthetic joint infection and septic arthritis

    by Fan Yang, Hyonmin Choe, Naomi Kobayashi, Taro Tezuka, Masatoshi Oba, Yushi Miyamae, Akira Morita, Koki Abe, Yutaka Inaba

    Synovial fluid is important for the preoperative etiological diagnosis of suspected periprosthetic joint infection (PJI) or septic arthritis (SA). GENECUBE, an automated real‐time polymerase chain reaction (PCR) assay, was used to detect bacterial mecA (methicillin resistance) and was compared with microbiological cultures for preoperatively diagnosing PJI and SA in 74 patients suspected of these infections and thus earmarked for surgery. PJI and SA were diagnosed in 21 and 6 cases, respectively, using modified ICM 2018 diagnostic criteria. Microbiological cultures determined methicillin‐resistant staphylococcus (MRS) as the causative organism in six samples, which were all positive in the GENECUBE assay. Significantly also, the GENECUBE assay detected six MRS infections in culture‐negative but infection‐diagnosed patients, and in one inconclusive case, suggesting a higher sensitivity of this assay. Compared with microbiological culture, the sensitivity and specificity of the GENECUBE assay for mecAwas 100% and 92.2%, respectively. However, GENECUBE also produced invalid results in three cases, suggesting possible PCR inhibitors in the synovial fluid samples. We additionally validated the accuracy of pan‐bacterial real‐time PCR targeting 16S rRNA and other tests. Pan‐bacterial real‐time PCR was as effective as preoperative bacterial culture testing, although the α‐defensin assay had the highest sensitivity at 100%. Hence, fully automated real‐time PCR targeting of the bacterial mecA gene improves the etiological diagnosis of PJI and SA by reducing the testing time and lowering the false‐positive detection rates. A screening approach for α‐defensin followed by bacterial mecA gene testing in synovial fluids is therefore a more efficient method of preoperatively diagnosing PJI and SA.


  • Mechanical Strength of the Proximal Femur After Arthroscopic Osteochondroplasty for Femoroacetabular Impingement: Finite Element Analysis and 3‐Dimensional Image Analysis

    by Masatoshi Oba, Naomi Kobayashi, Yutaka Inaba, Hyonmin Choe, Hiroyuki Ike, So Kubota, Tomoyuki Saito

    Purpose: To examine the influence of femoral neck resection on the mechanical strength of the proximal femur in actual surgery. Methods: Eighteen subjects who received arthroscopic cam resection for cam‐type femoroacetabular impingement (FAI) were included. Finite element analyses (FEAs) were performed to calculate changes in simulative fracture load between pre‐ and postoperative femur models. The finite element femur models were constructed from computed tomographic images; thus, the models represented the shape of the original femur, including the bone resection site. Three‐dimensional image analysis of the bone resection site was performed to identify morphometric factors that affect strength in the postoperative femur model. Four oblique sagittal planes running perpendicular to the femoral neck axis were used as reference planes to measure the bone resection site. Results: At the transcervical reference plane, both the bone resection depth and the cross‐sectional area at the resection site correlated strongly with postoperative changes in the simulated fracture load ( R 2 = 0.6, P = .0001). However, only resection depth was significantly correlated with the simulated fracture load at the reference plane for the head‐neck junction. The resected bone volume did not correlate with the postoperative changes in the simulated fracture load. Conclusions: The results of our FEA suggest that the bone resection depth measured at the head‐neck junction and transcervical reference plane correlates with fracture risk after osteochondroplasty. By contrast, bone resection at more proximal areas did not have a significant effect on the postoperative femur model strength in our FEA. The total volume of resected bone was also not significantly correlated with postoperative changes in femur model strength. Clinical Relevance: This biomechanical study using FEA suggest that there is a risk of femoral neck fracture after arthroscopic cam resection, particularly when the resected lesion is located distally.


  • New radiological parameters for the assessment of atlantoaxial instability in children with Down syndrome

    by N. Nakamura, Y. Inaba, Y. Aota, M. Oba, J. Machida, N. Aida, K. Kurosawa, T. Saito

    Aims: To determine the normal values and usefulness of the C1/4 space available for spinal cord (SAC) ratio and C1 inclination angle, which are new radiological parameters for assessing atlantoaxial instability in children with Down syndrome.Patients and Methods: We recruited 272 children with Down syndrome (including 14 who underwent surgical treatment), and 141 children in the control group. All were aged between two and 11 years. The C1/4 SAC ratio, C1 inclination angle, atlas-dens interval (ADI), and SAC were measured in those with Down syndrome, and the C1/4 SAC ratio and C1 inclination angle were measured in the control group.Results: The mean C1/4 SAC ratio in those requiring surgery with Down syndrome, those with Down syndrome not requiring surgery and controls were 0.63 (standard deviation (sd) 0.1), 1.15 (sd 0.13) and 1.29 (sd 0.14), respectively, and the mean C1 inclination angles were -3.1° (sd 10.7°), 15.8° (sd 7.3) and 17.2° (sd 7.3), in these three groups, respectively. The mean ADI and SAC in those with Down syndrome requiring surgery and those with Down syndrome not requiring surgery were 9.8 mm (sd 2.8) and 4.3 mm (sd 1.0), and 11.1 mm (sd 2.6) and 18.5 mm (sd 2.4), respectively.Conclusion: The normal values of the C1/4 SAC ratio and the C1 inclination angle were found to be about 1.2° and 15º, respectively. Cite this article: Bone Joint J 2016;98-B:1704–10.


  • Open Access

    Effect of femoral canal shape on mechanical stress distribution and adaptive bone remodelling around a cementless tapered-wedge stem

    by M. Oba, Y. Inaba, N. Kobayashi, H. Ike, T. Tezuka, T. Saito

    Objectives: In total hip arthroplasty (THA), the cementless, tapered-wedge stem design contributes to achieving initial stability and providing optimal load transfer in the proximal femur. However, loading conditions on the femur following THA are also influenced by femoral structure. Therefore, we determined the effects of tapered-wedge stems on the load distribution of the femur using subject-specific finite element models of femurs with various canal shapes.Patients and Methods: We studied 20 femurs, including seven champagne flute-type femurs, five stovepipe-type femurs, and eight intermediate-type femurs, in patients who had undergone cementless THA using the Accolade TMZF stem at our institution. Subject–specific finite element (FE) models of pre- and post-operative femurs with stems were constructed and used to perform FE analyses (FEAs) to simulate single-leg stance. FEA predictions were compared with changes in bone mineral density (BMD) measured for each patient during the first post-operative year.Results: Stovepipe models implanted with large-size stems had significantly lower equivalent stress on the proximal-medial area of the femur compared with champagne-flute and intermediate models, with a significant loss of BMD in the corresponding area at one year post-operatively.Conclusions: The stovepipe femurs required a large-size stem to obtain an optimal fit of the stem. The FEA result and post-operative BMD change of the femur suggest that the combination of a large-size Accolade TMZF stem and stovepipe femur may be associated with proximal stress shielding. Cite this article: M. Oba, Y. Inaba, N. Kobayashi, H. Ike, T. Tezuka, T. Saito. Effect of femoral canal shape on mechanical stress distribution and adaptive bone remodelling around a cementless tapered-wedge stem. Bone Joint Res 2016;5:362–369. DOI: 10.1302/2046-3758.59.2000525.


  • Open Access

    Giant cell tumour of the femur in a 9-year-old girl, resulting in severe leg length discrepancy

    by Masatoshi Oba, Yutaka Inaba, Jiro Machida, Tomoyuki Saito

    Giant cell tumour of bone (GCTB) is a rare benign tumour noted before physeal closure. GCTB cases in patients younger than 10 years are especially uncommon. The authors report the case of a 9-year-old girl with a GCTB of the distal femur. After initial intralesional excision and curettage of the tumour, local recurrence occurred, which needed two more additional surgeries to treat. The primary tumour and the local relapse invaded the growth plate of the right distal femur, leading to growth disturbance of the femur and requiring leg lengthening using Ilizarov apparatus. Surgeons should note the possibility of this rare condition while treating radiographic lytic lesions even in skeletally immature patients. The occurrence of late limb length discrepancy would be more likely in younger patients.


  • Novel 2 Radiographical Measurements for Atlantoaxial Instability in Children With Down Syndrome

    by Naoyuki Nakamura, Yutaka Inaba, Masatoshi Oba, Yoichi Aota, Yogen Morikawa, Yurika Ata, Jiro Machida, Tomoyuki Saito

    Study Design. A retrospective case-control study. Objective. To assess the usefulness and reproducibility of 2 novel safe and simple radiographical measurements for atlantoaxial instability in children with Down syndrome. Summary of Background Data. In pediatric atlantoaxial instability, early diagnosis is important for improved outcomes because of poor postoperative recovery in progressed neurological symptoms. Conventional dynamic radiography of the cervical spine is associated with a potential risk of worsening neurological symptoms. Methods. We retrospectively reviewed the medical records of 50 patients (24 boys and 26 girls) with atlantoaxial instability associated with Down syndrome. Of the 50 children, 11 had undergone and 4 had been scheduled for surgery (surgical group). In this investigation, in addition to the atlas-dens interval (ADI) and space available for spinal cord (SAC), we measured C1 inclination angle and C1/4 SAC ratio on lateral radiographs of the cervical spine in the neutral position. To assess the diagnostic abilities of these indices to determine indication for surgery, receiver operating characteristic analysis of each index was performed, and their diagnostic abilities were compared using the area under the receiver operating characteristic curve. Moreover, we assessed reproducibility of our 2 proposed indices. Results. The discriminatory abilities of C1/4 SAC ratio (area under the receiver operating characteristic curve, 1.00) and C1 inclination angle (0.91) were comparable with those of ADI (0.98) and SAC (0.95). For the interobserver and intraobserver reliability of the novel indices, the correlation coefficients were in the range from 0.88 to 0.99. Correlation was observed between the ADI and C1/4 SAC ratio (r = 0.507, P < 0.01) and between the ADI and C1 inclination angle (r = 0.407, P < 0.01). Conclusion. The diagnostic abilities of the 2 novel radiographical measurements were comparable with those of ADI and SAC. Moreover, these novel measurements can be obtained safely on lateral radiographs of the cervical spine in the neutral position. Level of Evidence: 4