Kaitlin G. Rabe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kaitlin G. Rabe has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Neil A. Segal
Department of Rehabilitation Medicine, University of Kansas, Kansas City, Kansas, United States
3 shared publicationsNicholas P. Fey
Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, United States
2 shared publications- Nicholas P. Fey
Walker Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX, USA
2 shared publications Ann Majewicz Fey
Department of Mechanical Engineering, The University of Texas Austin
1 shared publication- Anthony Jackson
Department of Rehabilitation Medicine, The University of Kansas, Kansas City, KS(‡)
1 shared publication Donald D. Anderson
1 shared publication
Latest Publications
- Open Access
- 21 March 2022
- Published by Frontiers Media SA in Frontiers in Robotics and AI
- Vol. 9, 716545
Evaluating Electromyography and Sonomyography Sensor Fusion to Estimate Lower-Limb Kinematics Using Gaussian Process Regression
Research on robotic lower-limb assistive devices over the past decade has generated autonomous, multiple degree-of-freedom devices to augment human performance during a variety of scenarios. However, the increase in capabilities of these devices is met with an increase in the complexity of the overall control problem and requirement for an accurate and robust sensing modality for intent recognition. Due to its ability to precede changes in motion, surface electromyography (EMG) is widely studied as a peripheral sensing modality for capturing features of muscle activity as an input for control of powered assistive devices. In order to capture features that contribute to muscle contraction and joint motion beyond muscle activity of superficial muscles, researchers have introduced sonomyography, or real-time dynamic ultrasound imaging of skeletal muscle. However, the ability of these sonomyography features to continuously predict multiple lower-limb joint kinematics during widely varying ambulation tasks, and their potential as an input for powered multiple degree-of-freedom lower-limb assistive devices is unknown. The objective of this research is to evaluate surface EMG and sonomyography, as well as the fusion of features from both sensing modalities, as inputs to Gaussian process regression models for the continuous estimation of hip, knee and ankle angle and velocity during level walking, stair ascent/descent and ramp ascent/descent ambulation. Gaussian process regression is a Bayesian nonlinear regression model that has been introduced as an alternative to musculoskeletal model-based techniques. In this study, time-intensity features of sonomyography on both the anterior and posterior thigh along with time-domain features of surface EMG from eight muscles on the lower-limb were used to train and test subject-dependent and task-invariant Gaussian process regression models for the continuous estimation of hip, knee and ankle motion. Overall, anterior sonomyography sensor fusion with surface EMG significantly improved estimation of hip, knee and ankle motion for all ambulation tasks (level ground, stair and ramp ambulation) in comparison to surface EMG alone. Additionally, anterior sonomyography alone significantly improved errors at the hip and knee for most tasks compared to surface EMG. These findings help inform the implementation and integration of volitional control strategies for robotic assistive technologies.
- 21 March 2022
- Published by Frontiers Media SA in Frontiers in Robotics and AI
- Vol. 9, 716545
Open AccessEvaluating Electromyography and Sonomyography Sensor Fusion to Estimate Lower-Limb Kinematics Using Gaussian Process Regression
Research on robotic lower-limb assistive devices over the past decade has generated autonomous, multiple degree-of-freedom devices to augment human performance during a variety of scenarios. However, the increase in capabilities of these devices is met with an increase in the complexity of the overall control problem and requirement for an accurate and robust sensing modality for intent recognition. Due to its ability to precede changes in motion, surface electromyography (EMG) is widely studied as a peripheral sensing modality for capturing features of muscle activity as an input for control of powered assistive devices. In order to capture features that contribute to muscle contraction and joint motion beyond muscle activity of superficial muscles, researchers have introduced sonomyography, or real-time dynamic ultrasound imaging of skeletal muscle. However, the ability of these sonomyography features to continuously predict multiple lower-limb joint kinematics during widely varying ambulation tasks, and their potential as an input for powered multiple degree-of-freedom lower-limb assistive devices is unknown. The objective of this research is to evaluate surface EMG and sonomyography, as well as the fusion of features from both sensing modalities, as inputs to Gaussian process regression models for the continuous estimation of hip, knee and ankle angle and velocity during level walking, stair ascent/descent and ramp ascent/descent ambulation. Gaussian process regression is a Bayesian nonlinear regression model that has been introduced as an alternative to musculoskeletal model-based techniques. In this study, time-intensity features of sonomyography on both the anterior and posterior thigh along with time-domain features of surface EMG from eight muscles on the lower-limb were used to train and test subject-dependent and task-invariant Gaussian process regression models for the continuous estimation of hip, knee and ankle motion. Overall, anterior sonomyography sensor fusion with surface EMG significantly improved estimation of hip, knee and ankle motion for all ambulation tasks (level ground, stair and ramp ambulation) in comparison to surface EMG alone. Additionally, anterior sonomyography alone significantly improved errors at the hip and knee for most tasks compared to surface EMG. These findings help inform the implementation and integration of volitional control strategies for robotic assistive technologies.
- Open Access
- 8 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 2635-2644
Performance of Sonomyographic and Electromyographic Sensing for Continuous Estimation of Joint Torque During Ambulation on Multiple Terrains
Advances in powered assistive device technology, including the ability to provide net mechanical power to multiple joints within a single device, have the potential to dramatically improve the mobility and restore independence to their users. However, these devices rely on the ability of their users to continuously control multiple powered lower-limb joints simultaneously. Success of such approaches rely on robust sensing of user intent and accurate mapping to device control parameters. Here, we compare two non-invasive sensing modalities: surface electromyography and sonomyography, (i.e., ultrasound imaging of skeletal muscle), as inputs to Gaussian process regression models trained to estimate hip, knee and ankle joint moments during varying forms of ambulation. Experiments were performed with ten non-disabled individuals instrumented with surface electromyography and sonomyography sensors while completing trials of level, incline (10°) and decline (10°) walking. Results suggest sonomyography of muscles on the anterior and posterior thigh can be used to estimate hip, knee and ankle joint moments more accurately than surface electromyography. Furthermore, these results can be achieved by training Gaussian process regression models in a task-independent manner; i.e., incorporating features of level and ramp walking within the same predictive framework. These findings support the integration of sonomyographic and electromyographic sensing within powered assistive devices to continuously control joint torque.
- 8 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 2635-2644
Open AccessPerformance of Sonomyographic and Electromyographic Sensing for Continuous Estimation of Joint Torque During Ambulation on Multiple Terrains
Advances in powered assistive device technology, including the ability to provide net mechanical power to multiple joints within a single device, have the potential to dramatically improve the mobility and restore independence to their users. However, these devices rely on the ability of their users to continuously control multiple powered lower-limb joints simultaneously. Success of such approaches rely on robust sensing of user intent and accurate mapping to device control parameters. Here, we compare two non-invasive sensing modalities: surface electromyography and sonomyography, (i.e., ultrasound imaging of skeletal muscle), as inputs to Gaussian process regression models trained to estimate hip, knee and ankle joint moments during varying forms of ambulation. Experiments were performed with ten non-disabled individuals instrumented with surface electromyography and sonomyography sensors while completing trials of level, incline (10°) and decline (10°) walking. Results suggest sonomyography of muscles on the anterior and posterior thigh can be used to estimate hip, knee and ankle joint moments more accurately than surface electromyography. Furthermore, these results can be achieved by training Gaussian process regression models in a task-independent manner; i.e., incorporating features of level and ramp walking within the same predictive framework. These findings support the integration of sonomyographic and electromyographic sensing within powered assistive devices to continuously control joint torque.
- 21 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (4) , 1379-1388
Ultrasound Sensing Can Improve Continuous Classification of Discrete Ambulation Modes Compared to Surface Electromyography
Clinical translation of “intelligent” lower-limb assistive technologies relies on robust control interfaces capable of accurately detecting user intent. To date, mechanical sensors and surface electromyography (EMG) have been the primary sensing modalities used to classify ambulation. Ultrasound (US) imaging can be used to detect user-intent by characterizing structural changes of muscle. Our study evaluates wearable US imaging as a new sensing modality for continuous classification of five discrete ambulation modes: level, incline, decline, stair ascent, and stair descent ambulation, and benchmarks performance relative to EMG sensing. Ten able-bodied subjects were equipped with a wearable US scanner and eight unilateral EMG sensors. Time-intensity features were recorded from US images of three thigh muscles. Features from sliding windows of EMG signals were analyzed in two configurations: one including 5 EMG sensors on muscles around the thigh, and another with 3 additional sensors placed on the shank. Linear discriminate analysis was implemented to continuously classify these phase-dependent features of each sensing modality as one of five ambulation modes. US-based sensing statistically improved mean classification accuracy to 99.8% (99.5-100% CI) compared to 8-EMG sensors (85.8%; 84.0-87.6% CI) and 5-EMG sensors (75.3%; 74.5-76.1% CI). Further, separability analyses show the importance of superficial and deep US information for stair classification relative to other modes. These results are the first to demonstrate the ability of US-based sensing to classify discrete ambulation modes, highlighting the potential for improved assistive device control using less widespread, less superficial and higher resolution sensing of skeletal muscle.
- 21 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (4) , 1379-1388
Ultrasound Sensing Can Improve Continuous Classification of Discrete Ambulation Modes Compared to Surface Electromyography
Clinical translation of “intelligent” lower-limb assistive technologies relies on robust control interfaces capable of accurately detecting user intent. To date, mechanical sensors and surface electromyography (EMG) have been the primary sensing modalities used to classify ambulation. Ultrasound (US) imaging can be used to detect user-intent by characterizing structural changes of muscle. Our study evaluates wearable US imaging as a new sensing modality for continuous classification of five discrete ambulation modes: level, incline, decline, stair ascent, and stair descent ambulation, and benchmarks performance relative to EMG sensing. Ten able-bodied subjects were equipped with a wearable US scanner and eight unilateral EMG sensors. Time-intensity features were recorded from US images of three thigh muscles. Features from sliding windows of EMG signals were analyzed in two configurations: one including 5 EMG sensors on muscles around the thigh, and another with 3 additional sensors placed on the shank. Linear discriminate analysis was implemented to continuously classify these phase-dependent features of each sensing modality as one of five ambulation modes. US-based sensing statistically improved mean classification accuracy to 99.8% (99.5-100% CI) compared to 8-EMG sensors (85.8%; 84.0-87.6% CI) and 5-EMG sensors (75.3%; 74.5-76.1% CI). Further, separability analyses show the importance of superficial and deep US information for stair classification relative to other modes. These results are the first to demonstrate the ability of US-based sensing to classify discrete ambulation modes, highlighting the potential for improved assistive device control using less widespread, less superficial and higher resolution sensing of skeletal muscle.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 988-993
Gait Phase Identification During Level, Incline and Decline Ambulation Tasks Using Portable Sonomyographic Sensing
Clinical viability of powered lower-limb assistive devices requires reliable and intuitive control strategies. Stance and swing are the main phases of the gait cycle across different locomotion tasks. Hence, a reliable method to accurately identify these phases can decrease sensing complexity and assist in enabling high-level control of assistive devices. Ultrasound (US) imaging has recently been introduced as a new sensing modality that may provide a solution for intuitive device control. US images of the rectus femoris and vastus intermedius muscles were collected in humans during level, incline, and decline ambulation tasks. Five low-level static (i.e. time-independent) features of US images were measured with respect to a reference image, including correlation coefficient, sum of absolute differences, structural similarity index, sum of squared differences, and image echogenicity. Time-derivatives of the static features were also calculated as temporal features. Support vector machine classifiers were trained using these static features to identify the gait phase both dependent and independent of the ambulation tasks. The results indicate an accuracy of 88.3% in identifying the gait phases for task-independent classifiers when trained using only the static features. Performance of the classifiers improved significantly to 92.8% after using the temporal features (p $\lt0.01)$. The algorithm was efficient and the average processing speed was faster than 100 Hz. This study is the first demonstration on use of US imaging to provide continuous estimates of ambulation phase, and on multiple surfaces. These findings suggest task-independent approaches may reliably identify the main phases of the gait cycle. Advancements in this area of study may provide simpler intuitive strategies for high-level assistive device control and increase their clinical relevance.- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 988-993
Gait Phase Identification During Level, Incline and Decline Ambulation Tasks Using Portable Sonomyographic Sensing
Clinical viability of powered lower-limb assistive devices requires reliable and intuitive control strategies. Stance and swing are the main phases of the gait cycle across different locomotion tasks. Hence, a reliable method to accurately identify these phases can decrease sensing complexity and assist in enabling high-level control of assistive devices. Ultrasound (US) imaging has recently been introduced as a new sensing modality that may provide a solution for intuitive device control. US images of the rectus femoris and vastus intermedius muscles were collected in humans during level, incline, and decline ambulation tasks. Five low-level static (i.e. time-independent) features of US images were measured with respect to a reference image, including correlation coefficient, sum of absolute differences, structural similarity index, sum of squared differences, and image echogenicity. Time-derivatives of the static features were also calculated as temporal features. Support vector machine classifiers were trained using these static features to identify the gait phase both dependent and independent of the ambulation tasks. The results indicate an accuracy of 88.3% in identifying the gait phases for task-independent classifiers when trained using only the static features. Performance of the classifiers improved significantly to 92.8% after using the temporal features (p $\lt0.01)$. The algorithm was efficient and the average processing speed was faster than 100 Hz. This study is the first demonstration on use of US imaging to provide continuous estimates of ambulation phase, and on multiple surfaces. These findings suggest task-independent approaches may reliably identify the main phases of the gait cycle. Advancements in this area of study may provide simpler intuitive strategies for high-level assistive device control and increase their clinical relevance.- 1 January 2019
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 221, 68-75
Is muscle strength in a painful limb affected by knee pain status of the contralateral limb? — Data from the Osteoarthritis Initiative
- 1 January 2019
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 221, 68-75
Is muscle strength in a painful limb affected by knee pain status of the contralateral limb? — Data from the Osteoarthritis Initiative
Evaluation of the Combined Application of Neuromuscular Electrical Stimulation and Volitional Contractions on Thigh Muscle Strength, Knee Pain, and Physical Performance in Women at Risk for Knee Osteoarthritis: A Randomized Controlled Trial
Background: Knee osteoarthritis (OA) is a leading cause of disability that is associated with quadriceps weakness. However, strengthening in people with or with risk factors for knee OA can be poorly tolerated.Objective: To assess the efficacy of a 12‐week low‐load exercise program, using a hybrid training system (HTS) that uses the combination of neuromuscular electrical stimulation and volitional contractions, for improving thigh muscle strength, knee pain relief, and physical performance in women with or with risk factors for knee OA.Design: Randomized, single‐blinded, controlled trial.Setting: Exercise training laboratory.Participants: Forty‐two women 44‐85 years old with risk factors for knee OA.Interventions: Participants randomized to 12 weeks of biweekly low‐load resistance training with the HTS or on an isokinetic dynamometer (control).Outcomes: Maximum isokinetic knee extensor torque. Secondary measures included maximum isokinetic knee flexor torque, knee pain (Knee Injury and Osteoarthritis Outcome Score), and timed 20‐m walk and chair stand tests.Results: The HTS and control treatments resulted in muscle strengthening, decreased knee pain, and improved physical performance. HTS group quadriceps and hamstring strength increased by 0.06 ± 0.04 Nm/kg (P > .05) and 0.05 ± 0.02 Nm/kg (P = .02), respectively. Control group quadriceps and hamstring strength increased by 0.03 ± 0.04 Nm/kg (P > .05) and 0.06 ± 0.02 Nm/kg (P = .009), respectively. Knee pain decreased by 11.9 ± 11.5 points (P < .001) for the HTS group and 14.1 ± 15.4 points (P = .001) for the control group. The 20‐m walk time decreased by 1.60 ± 2.04 seconds (P = .005) and 0.95 ± 1.2 seconds (P = .004), and chair stand time decreased by 4.8 ± 10.0 seconds (P > .05) and 1.9 ± 4.7 seconds (P > .05) in the HTS and control groups, respectively. These results did not differ statistically between the HTS and control groups.Conclusions: These results suggest the HTS is effective for alleviating pain and improving physical performance in women with risk factors for knee OA. However, the HTS does not appear to be superior to low‐load resistance training for improving muscle strength, pain relief, or physical function.Clinical trial registration number: NCT02802878.Level of Evidence: I
Evaluation of the Combined Application of Neuromuscular Electrical Stimulation and Volitional Contractions on Thigh Muscle Strength, Knee Pain, and Physical Performance in Women at Risk for Knee Osteoarthritis: A Randomized Controlled Trial
Background: Knee osteoarthritis (OA) is a leading cause of disability that is associated with quadriceps weakness. However, strengthening in people with or with risk factors for knee OA can be poorly tolerated.Objective: To assess the efficacy of a 12‐week low‐load exercise program, using a hybrid training system (HTS) that uses the combination of neuromuscular electrical stimulation and volitional contractions, for improving thigh muscle strength, knee pain relief, and physical performance in women with or with risk factors for knee OA.Design: Randomized, single‐blinded, controlled trial.Setting: Exercise training laboratory.Participants: Forty‐two women 44‐85 years old with risk factors for knee OA.Interventions: Participants randomized to 12 weeks of biweekly low‐load resistance training with the HTS or on an isokinetic dynamometer (control).Outcomes: Maximum isokinetic knee extensor torque. Secondary measures included maximum isokinetic knee flexor torque, knee pain (Knee Injury and Osteoarthritis Outcome Score), and timed 20‐m walk and chair stand tests.Results: The HTS and control treatments resulted in muscle strengthening, decreased knee pain, and improved physical performance. HTS group quadriceps and hamstring strength increased by 0.06 ± 0.04 Nm/kg (P > .05) and 0.05 ± 0.02 Nm/kg (P = .02), respectively. Control group quadriceps and hamstring strength increased by 0.03 ± 0.04 Nm/kg (P > .05) and 0.06 ± 0.02 Nm/kg (P = .009), respectively. Knee pain decreased by 11.9 ± 11.5 points (P < .001) for the HTS group and 14.1 ± 15.4 points (P = .001) for the control group. The 20‐m walk time decreased by 1.60 ± 2.04 seconds (P = .005) and 0.95 ± 1.2 seconds (P = .004), and chair stand time decreased by 4.8 ± 10.0 seconds (P > .05) and 1.9 ± 4.7 seconds (P > .05) in the HTS and control groups, respectively. These results did not differ statistically between the HTS and control groups.Conclusions: These results suggest the HTS is effective for alleviating pain and improving physical performance in women with risk factors for knee OA. However, the HTS does not appear to be superior to low‐load resistance training for improving muscle strength, pain relief, or physical function.Clinical trial registration number: NCT02802878.Level of Evidence: I
The Effect of Arch Drop on Tibial Rotation and Tibiofemoral Contact Stress in Postpartum Women
Background: Women are at greater risk for knee osteoarthritis and numerous other lower limb musculoskeletal disorders. Arch drop during pregnancy and the resultant excessive pronation of the feet may alter loading patterns and contribute to the greater prevalence of knee osteoarthritis in women.Objective: To determine the effect of arch drop on tibial rotation and tibiofemoral contact stress.Design: Interventional study with internal control.Setting: Biomechanics laboratory.Participants: Eleven postpartum women (age 33.4 ± 5.3 years, body mass 76.1 ± 13.5 kg) who had lost arch height with pregnancy in a previous study.Methods: Subjects underwent standing computed tomography (SCT) with their knees in a 20° fixed‐flexed position with and without semirigid arch supports to reconstitute prepregnancy arch height. Magnetic resonance imaging of the knee was acquired at a flexion angle equivalent to that of SCT. Bone and cartilage were manually segmented on the magnetic resonance images and segmented surfaces were registered to the 3‐dimensional SCT image sets for the arch‐supported and ‐unsupported conditions. These models were used to measure changes in tibial rotation, as well as to estimate contact stress in the medial and lateral tibiofemoral compartments, using computational methods.Main Outcome Measures: Change in tibial rotation and tibiofemoral contact stress with arch drop.Results: Arch drop resulted in a mean tibial internal rotation of 0.75 ± 1.33° (P = .02). Changes in mean or peak contact stress were not detected.Conclusions: Arch drop causes internal tibial rotation, resulting in a shift in the tibiofemoral articulation. An associated increase in contact stress was not detected. Internal rotation of the tibia increases stress on the anterior cruciate ligament and menisci, potentially explaining the greater prevalence of knee disorders in postpartum women.Level of Evidence: NA
The Effect of Arch Drop on Tibial Rotation and Tibiofemoral Contact Stress in Postpartum Women
Background: Women are at greater risk for knee osteoarthritis and numerous other lower limb musculoskeletal disorders. Arch drop during pregnancy and the resultant excessive pronation of the feet may alter loading patterns and contribute to the greater prevalence of knee osteoarthritis in women.Objective: To determine the effect of arch drop on tibial rotation and tibiofemoral contact stress.Design: Interventional study with internal control.Setting: Biomechanics laboratory.Participants: Eleven postpartum women (age 33.4 ± 5.3 years, body mass 76.1 ± 13.5 kg) who had lost arch height with pregnancy in a previous study.Methods: Subjects underwent standing computed tomography (SCT) with their knees in a 20° fixed‐flexed position with and without semirigid arch supports to reconstitute prepregnancy arch height. Magnetic resonance imaging of the knee was acquired at a flexion angle equivalent to that of SCT. Bone and cartilage were manually segmented on the magnetic resonance images and segmented surfaces were registered to the 3‐dimensional SCT image sets for the arch‐supported and ‐unsupported conditions. These models were used to measure changes in tibial rotation, as well as to estimate contact stress in the medial and lateral tibiofemoral compartments, using computational methods.Main Outcome Measures: Change in tibial rotation and tibiofemoral contact stress with arch drop.Results: Arch drop resulted in a mean tibial internal rotation of 0.75 ± 1.33° (P = .02). Changes in mean or peak contact stress were not detected.Conclusions: Arch drop causes internal tibial rotation, resulting in a shift in the tibiofemoral articulation. An associated increase in contact stress was not detected. Internal rotation of the tibia increases stress on the anterior cruciate ligament and menisci, potentially explaining the greater prevalence of knee disorders in postpartum women.Level of Evidence: NA