FSFlorence H. Sheehan

Florence H. Sheehan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Florence H. Sheehan has a total of 112 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Education Research: Simulator-Based Training in Transcranial Doppler Ultrasound

    by Aidan Shev, Florence Sheehan, Ziao Yin, Angela Straccia, Daniel F. Leotta, Alberto Aliseda, R. Eugene Zierler, Mark D. Anderson, Deepak Sharma

    Transcranial Doppler (TCD) ultrasound is recommended for measuring cerebral blood flow velocity to guide therapeutic intervention in patients with cerebrovascular diseases. However, the widespread use of TCD is hampered by a shortage of trained practitioners. This study evaluated the efficacy of a simulator-based curriculum in teaching novices the foundational skill to perform TCD insonation. We developed a curriculum on a novel simulator that incorporates interactive practice with real-time feedback. We assessed change in the skill levels of medical and premedical students without previous exposure to TCD from pretraining and posttraining tests. Psychomotor skill was assessed based on accuracy in insonating the middle cerebral, anterior cerebral, ophthalmic, basilar, and vertebral arteries. Cognitive skill (knowledge) was assessed using multiple-choice questions (MCQs). Training significantly improved skill: the correct insonation rate increased from 16 ± 24% (95% CI 9%–23%) on the pretest to 61 ± 34% (95% CI 52%–70%) on the posttest (N = 56, p < 0.0001, Cohen d = 1.5). First-attempt accuracy improved from 15 ± 23% (95% CI 9%–21%) to 49 ± 31% (95% CI 41%–57%) (N = 56, p < 0.0001, Cohen d = 0.9). Knowledge increased markedly, with MCQs answered correctly rising from 7 ± 26% (95% CI 0%–14%) to 64 ± 19% (95% CI 59%–69%) (p < 0.0001, Cohen d = 2.5). The course, including pre-test and posttests, was completed in 2.6 ± 1.0 hours. Simulator-based training rapidly improved the ability of novices to locate intracranial arteries for measurement of blood flow velocity. The data support the employment of simulator-based training as a foundational step to help alleviate the shortage of trained providers. The simulator's self-directed practice allows for scalable, standardized training.


  • A Novel Patient-Specific Computational Fluid Dynamics Study of the Activation of Primary Collateral Pathways in the Circle of Willis During Vasospasm

    by Angela Straccia, Fanette Chassagne, David I. Bass, Guilherme Barros, Daniel F. Leotta, Florence Sheehan, Deepak Sharma, Michael R. Levitt, Alberto Aliseda

    The Circle of Willis (CoW) is a redundant network of blood vessels that perfuses the brain. The ringlike anatomy mitigates the negative effects of stroke by activating collateral pathways that help maintain physiological perfusion. Previous studies have investigated the activation of these pathways during embolic stroke and internal carotid artery occlusion. However, the role of collateral pathways during cerebral vasospasm—an involuntary constriction of blood vessels after subarachnoid hemorrhage—is not well-documented. This study presents a novel technique to create patient-specific computational fluid dynamics (CFD) simulations of the Circle of Willis before and during vasospasm. Computed tomographic angiography (CTA) scans are segmented to model the vasculature, and transcranial Doppler ultrasound (TCD) measurements of blood flow velocity are applied as boundary conditions. Bayesian analysis leverages information about the uncertainty in the measurements of vessel diameters and velocities to find an optimized parameter set that satisfies mass conservation and that is applied in the final simulation. With this optimized parameter set, the diameters, velocities, and flow rates fall within typical literature values. Virtual angiograms modeled using passive scalar transport agree closely with clinical angiography. A sensitivity analysis quantifies the changes in collateral flow rates with respect to changes in the inlet and outlet flow rates. This analysis can be applied in the future to a cohort of patients to investigate the relationship between the locations and severities of vasospasm, the patient-to-patient anatomical variability in the Circle of Willis, and the activation of collateral pathways.


  • Focused cardiac ultrasound training in medical students: Using an independent, simulator‐based curriculum to objectively measure skill acquisition and learning curve

    by David M. Elison, Shannon McConnaughey, Rosario V. Freeman, Florence H. Sheehan

    Background: Using simulators built and validated at the University of Washington (UW), the study sought to test whether medical students can learn the basic skills of focused cardiac ultrasound (FoCUS) from an individually paced, simulator‐based curriculum, how skills improve, and the rate at which these skills are acquired.Methods: The curriculum presented didactic material interspersed with hands‐on practice. Psychomotor skill was measured by the angle error of the acquired image view plane relative to the correct image view plane. The rate of learning was assessed at baseline, after 7 practice cases, and after 10 cases. To assess the rate of learning, the same case was repeatedly presented at all three tests. To assess students’ ability to apply their learning, a previously unseen post‐test was included.Results: A total of 41 students completed the course. Average angle error improved from 43° ± 24 pretraining to 23° ± 16 post‐training, with most students falling within one SD of the view angle acquired by sonographers. Regarding learning curve, or the rate of skill acquisition, an angle error of 43 ± 24° (pre) changed to 22 ± 14° (interim test, P < .0001 vs. pretest) and remained at that level for the post‐test evaluation on both the repeated case (23 ± 16°) and the new case (26 ± 18°).Conclusions: This study describes the learning curve and technical skill acquisition in FoCUS. A simulator‐based curriculum improved medical student's skills in an objective and quantifiable manner. The individually paced curriculum allowed for independent knowledge and skill attainment, without facilitator oversight.


  • Analysis of Factors Influencing Accuracy of Volume Flow Measurement in Dialysis Access Fistulas Based on Duplex Ultrasound Simulation

    by R. Eugene Zierler, Daniel F. Leotta, Kurt Sansom, Alberto Aliseda, Mark D. Anderson, Florence H. Sheehan

    We developed a duplex ultrasound simulator and used it to assess accuracy of volume flow measurements in dialysis access fistula (DAF) models. The simulator consists of a mannequin, computer, and mock transducer. Each case is built from a patient’s B-mode images that are used to create a 3-dimensional surface model of the DAF. Computational fluid dynamics is used to determine blood flow velocities based on model vessel geometry. The simulator displays real-time B-mode and color-flow images, and Doppler spectral waveforms are generated according to user-defined settings. Accuracy was assessed by scanning each case and measuring volume flow in the inflow artery and outflow vein for comparison with true volume flow values. Four examiners made 96 volume flow measurements on four DAF models. Measured volume flow deviated from the true value by 35 ± 36%. Mean absolute deviation from true volume flow was lower for arteries than veins (22 ± 19%, N = 48 vs. 58 ± 33%, N = 48, p < 0.0001). This finding is attributed to eccentricity of outflow veins which resulted in underestimating true cross-sectional area. Regression analysis indicated that error in measuring cross-sectional area was a predictor of error in volume flow measurement (β = 0.948, p < 0.001). Volume flow error was reduced from 35 ± 36% to 9 ± 8% (p < 0.000001) by calculating vessel area as an ellipse. Duplex volume flow measurements are based on a circular vessel shape. DAF inflow arteries are circular, but outflow veins can be elliptical. Simulation-based analysis showed that error in measuring volume flow is mainly due to assumption of a circular vessel.


  • Test of simulator‐based assessment of psychomotor skill in transthoracic echo

    by Reidar Winter, Per Lindqvist, Florence H. Sheehan

    Summary: Background: We developed a transthoracic echo simulator that measures technical skill in image acquisition in terms of the deviation angle between an acquired image and the anatomically correct plane for that view. We studied whether this metric reflects the clinical experience of providers.Methods: Attendees at an echo course or at the annual meeting of the Swedish Heart Association were invited to test themselves on the simulator by scanning a mannequin and acquiring four views in 15 min: parasternal long axis (pLAX) in patient 1, apical four chamber and apical long axis (aLAX) in patient 2 and pLAX in patient 3. Their experience with echo was assessed from duration in years and procedure volume in the past year. Image acquisition error was assessed from the deviation angle.Results: Of 61 participants, there were 37 physicians and 24 non‐physicians (22 sonographers and two nurses). Non‐physicians had higher procedure volume than physicians (850 ± 599 versus 312 ± 393 tests year−1, PP = NS). The deviation angle for aLAX (55 ± 37 degrees) was higher than for any other view (Pr = −0·357, P = 0·008).Conclusions: These results demonstrate that deviation angle, a novel metric of technical skill in image acquisition, reflects clinical experience. Simulator‐based testing provides objective and quantitative assessment that may be of value in the certification of trainees and for maintenance of certification.


  • Simulation for competency assessment in vascular and cardiac ultrasound

    by Florence H Sheehan, R Eugene Zierler

    Healthcare providers who use peripheral vascular and cardiac ultrasound require specialized training to develop the technical and interpretive skills necessary to perform accurate diagnostic tests. Assessment of competence is a critical component of training that documents a learner’s progress and is a requirement for competency-based medical education (CBME) as well as specialty certification or credentialing. The use of simulation for CBME in diagnostic ultrasound is particularly appealing since it incorporates both the psychomotor and cognitive domains while eliminating dependency on the availability of live patients with a range of pathology. However, successful application of simulation in this setting requires realistic, full-featured simulators and appropriate standardized metrics for competency testing. The principal diagnostic parameter in peripheral vascular ultrasound is measurement of peak systolic velocity (PSV) on Doppler spectral waveforms, and simulation of Doppler flow detection presents unique challenges. The computer-based duplex ultrasound simulator developed at the University of Washington uses computational fluid dynamics modeling and presents real-time color-flow Doppler images and Doppler spectral waveforms along with the corresponding B-mode images. This simulator provides a realistic scanning experience that includes measuring PSV in various arterial segments and applying actual diagnostic criteria. Simulators for echocardiography have been available since the 1990s and are currently more advanced than those for peripheral vascular ultrasound. Echocardiography simulators are now offered for both transesophageal echo and transthoracic echo. These computer-based simulators have 3D graphic displays that provide feedback to the learner and metrics for assessment of technical skill that are based on transducer tracking data. Such metrics provide a motion-based or kinematic analysis of skill in performing cardiac ultrasound. The use of simulation in peripheral vascular and cardiac ultrasound can provide a standardized and readily available method for training and competency assessment.


  • Quantitative Feedback Facilitates Acquisition of Skills in Focused Cardiac Ultrasound

    by Alisha A. Skinner, Rosario V. Freeman, Florence H. Sheehan

    Introduction With the development of portable, affordable ultrasound machines1 with good image quality, many physicians have adopted focused cardiac ultrasound (FoCUS). To facilitate acquisition of these skills, we developed a simulator-based, self-taught curriculum for FoCUS that provides immediate feedback for rapid performance improvement. Methods Twenty-two first-year residents participated in the study. The curriculum consisted of instructive modules teaching image acquisition and interpretation of standard echocardiography views and common cardiac pathology, 7 practice cases in which participants scanned a mannequin using a mock transducer, acquired specified views with feedback provided by visual guidance technology, and interpreted these images. Trainees were tested pretraining and posttraining on different cases, without visual guidance assistance or feedback. Previously validated metrics were used to assess psychomotor skill in terms of the angle error in degrees between the planes of the optimal view, defined anatomically, and of the acquired view, as well as cognitive skill in image interpretation. Results The average error in image acquisition decreased from a median of 81 degrees at the pretest to 28 degrees after training (P < 0.0001). Cognitive skill improved by 29% (21%, P < 0.0001). There was a significant correlation between cognitive and psychomotor skill (r = 0.64, P < 0.001). Discussion A novel, simulator-based curriculum that provides immediate feedback was effective in teaching both psychomotor and cognitive skills in FoCUS without need for direct expert oversight of the learner. The curriculum’s components provide a useful tool that can be applied to improve, assess, and monitor physician skill in FoCUS.


  • Echocardiography of Chronic Right Heart Failure

    by Florence H. Sheehan, Per Lindqvist

  • The shape and function of the left ventricle in Ebstein's anomaly

    by Patrick J. Goleski, Florence H. Sheehan, Sylvia S.M. Chen, Philip J. Kilner, Michael A. Gatzoulis


  • Open Access

    The Transaxial Orientation Is Superior to Both the Short Axis and Horizontal Long Axis Orientations for Determining Right Ventricular Volume and Ejection Fraction Using Simpson's Method with Cardiac Magnetic Resonance

    by Michael K. Atalay, Kevin J. Chang, David J. Grand, Shawn Haji-Momenian, Jason T. Machan, Florence H. Sheehan

    We sought to determine which of the three orientations is the most reliable and accurate for quantifying right ventricular (RV) volume and ejection fraction (EF) by cardiac magnetic resonance using Simpson’s method. We studied 20 patients using short axis (SA), transaxial (TA), and horizontal long axis (HLA) orientations. Three readers independently traced RV endocardial contours at end-diastole and end-systole for each orientation. End-diastolic volumes (EDVs), end-systolic volumes (ESVs), and EF were calculated and compared with the 3D piecewise smooth subdivision surface (PSSS) method. The intraclass correlation coefficients among the 3 readers for EDV, ESV, and EF were 0.92, 0.82, and 0.42, respectively, for SA, 0.95, 0.92, and 0.67 for TA, and 0.85, 0.93, and 0.69 for HLA. For mean data there was no significant difference between TA and PSSS for EDV (−2.6%, 95% CI: −8.2 to 3.3%), ESV (−5.9%, −15.2 to 4.5%), and EF (1.7%, −1.5 to 4.9%). HLA was accurate for ESV (−8.9%, −18.5 to 1.8%) and EF (−0.7%, −3.8 to 2.5%) but significantly underestimated EDV (−9.8, −16.6 to −2.4%). SA was accurate for EDV (0.5%, −6.0 to 7.5%) but overestimated ESV (10.5%, 0.1 to 21.9%) and had poor interrater reliability for EF. Conclusions. The TA orientation provides the most reliable and accurate measures of EDV, ESV, and EF.