Latest Publications
- Open Access
Improving the Ambient Temperature Control Performance in Smart Homes and Buildings
Currently, it is becoming increasingly common to find numerous electronic devices installed in office and residential spaces as part of building automation solutions. These devices provide a rich set of data related to the inside and outside environment, such as indoor and outdoor temperature, humidity, and solar radiation. However, commercial of-the-shelf climatic control systems continue to rely on simple controllers like proportional-integral-derivative or even on-off, which do not take into account such variables. This work evaluates the potential performance gains of adopting more advanced controllers, in this case based on pole-placement, enhanced with additional variables, namely solar radiation and external temperature, obtained with dedicated low-cost sensors. This approach is evaluated both in simulated and real-world environments. The obtained results show that pole-placement controllers clearly outperform on-off controllers and that the use of the additional variables in pole-placement controllers allows relevant performance gains in key parameters such as error signal MSE (17%) and control signal variance (40%), when compared with simple PP controllers. The observed energy consumption savings obtained by using the additional variables are marginal (≈1%, but the reduction of the error signal MSE and control signal variance have a significant impact on energy consumption peaks and on equipment lifetime, thus largely compensating the increase in the system complexity.
Open AccessImproving the Ambient Temperature Control Performance in Smart Homes and Buildings
Currently, it is becoming increasingly common to find numerous electronic devices installed in office and residential spaces as part of building automation solutions. These devices provide a rich set of data related to the inside and outside environment, such as indoor and outdoor temperature, humidity, and solar radiation. However, commercial of-the-shelf climatic control systems continue to rely on simple controllers like proportional-integral-derivative or even on-off, which do not take into account such variables. This work evaluates the potential performance gains of adopting more advanced controllers, in this case based on pole-placement, enhanced with additional variables, namely solar radiation and external temperature, obtained with dedicated low-cost sensors. This approach is evaluated both in simulated and real-world environments. The obtained results show that pole-placement controllers clearly outperform on-off controllers and that the use of the additional variables in pole-placement controllers allows relevant performance gains in key parameters such as error signal MSE (17%) and control signal variance (40%), when compared with simple PP controllers. The observed energy consumption savings obtained by using the additional variables are marginal (≈1%, but the reduction of the error signal MSE and control signal variance have a significant impact on energy consumption peaks and on equipment lifetime, thus largely compensating the increase in the system complexity.
- Open Access
- 7 June 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (11) , 3958
Model Predictive Control of Non-Linear Systems Using Tensor Flow-Based Models
The present paper proposes an approach for the development of a non-linear model-based predictive controller (NMPC) using a non-linear process model based on Artificial Neural Networks (ANNs). This work exploits recent trends on ANN literature using a TensorFlow implementation and shows how they can be efficiently used as support for closed-loop control systems. Furthermore, it evaluates how the generalization capability problems of neural networks can be efficiently overcome when the model that supports the control algorithm is used outside of its initial training conditions. The process’s transient response performance and steady-state error are parameters under focus and will be evaluated using a MATLAB’s Simulink implementation of a Coupled Tank Liquid Level controller and a Yeast Fermentation Reaction Temperature controller, two well-known benchmark systems for non-linear control problems.
- 7 June 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (11) , 3958
Open AccessModel Predictive Control of Non-Linear Systems Using Tensor Flow-Based Models
The present paper proposes an approach for the development of a non-linear model-based predictive controller (NMPC) using a non-linear process model based on Artificial Neural Networks (ANNs). This work exploits recent trends on ANN literature using a TensorFlow implementation and shows how they can be efficiently used as support for closed-loop control systems. Furthermore, it evaluates how the generalization capability problems of neural networks can be efficiently overcome when the model that supports the control algorithm is used outside of its initial training conditions. The process’s transient response performance and steady-state error are parameters under focus and will be evaluated using a MATLAB’s Simulink implementation of a Coupled Tank Liquid Level controller and a Yeast Fermentation Reaction Temperature controller, two well-known benchmark systems for non-linear control problems.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 255-260
Adaptive Ambient Temperature Control of Indoor Environments
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 255-260
Adaptive Ambient Temperature Control of Indoor Environments
- 16 July 2017
- Published by Springer Nature
- p. 125-127
Conclusions
- 16 July 2017
- Published by Springer Nature
- p. 111-124
Processor-In-the-Loop Simulation
- 16 July 2017
- Published by Springer Nature
- p. 81-110
Model Predictive Control Using Type-2 Takagi-Sugeno Fuzzy Systems
- 16 July 2017
- Published by Springer Nature
- p. 81-110
Model Predictive Control Using Type-2 Takagi-Sugeno Fuzzy Systems
- 16 July 2017
- Published by Springer Nature
- p. 59-79
System Modeling Using Type-2 Takagi-Sugeno Fuzzy Systems
- 16 July 2017
- Published by Springer Nature
- p. 59-79
System Modeling Using Type-2 Takagi-Sugeno Fuzzy Systems
- 16 July 2017
- Published by Springer Nature
- p. 7-34
Fuzzy Logic Systems
- 16 July 2017
- Published by Springer Nature
- p. 35-57
Takagi-Sugeno Fuzzy Logic Systems
- 16 July 2017
- Published by Springer Nature
- p. 1-5
Introduction