Alexander V. Bolotov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alexander V. Bolotov has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Yury D. Korolev
Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk, Russia
27 shared publications - Nikolay V. Landl
Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk, Russia
26 shared publications O. B. Frants
Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk, Russia
11 shared publications- O. B. Frants
Institute of High Current Electronics of the Siberian Branch of the Russian Academy of Sciences, Tomsk, Russia
7 shared publications V. G. Geyman
Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk, Russia
7 shared publicationsV. O. Nekhoroshev
Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk, Russia
7 shared publications
Latest Publications
- 1 December 2025
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 89 (S2) , S212-S217
Parasitic Current in a Pseudospark Switch at Different Electric Circuits for Powering the Auxiliary Glow Discharge
One of the trigger systems for the pseudospark switches is based on a usage of the low-current auxiliary glow discharge with hollow cathode and hollow anode. The electrodes of the auxiliary discharge are often placed inside the grounded cathode cavity of the main high-voltage electrode gap. The space of the auxiliary discharge communicates with the space of the main cathode cavity via the aperture in the flat part of one of the trigger electrodes. Then the characteristic feature of such an arrangement is the availability of the so-called parasitic current, which flows via the aperture to the grounded cathode. This paper deals with the investigation of the features of the formation of the parasitic current at different electric circuits for powering the auxiliary discharge.
- 1 December 2025
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 89 (S2) , S212-S217
Parasitic Current in a Pseudospark Switch at Different Electric Circuits for Powering the Auxiliary Glow Discharge
One of the trigger systems for the pseudospark switches is based on a usage of the low-current auxiliary glow discharge with hollow cathode and hollow anode. The electrodes of the auxiliary discharge are often placed inside the grounded cathode cavity of the main high-voltage electrode gap. The space of the auxiliary discharge communicates with the space of the main cathode cavity via the aperture in the flat part of one of the trigger electrodes. Then the characteristic feature of such an arrangement is the availability of the so-called parasitic current, which flows via the aperture to the grounded cathode. This paper deals with the investigation of the features of the formation of the parasitic current at different electric circuits for powering the auxiliary discharge.
- 1 November 2025
- Published by Kotelnikov Institute of Radioengineering and Electronics of Russian Academy of Sciences in Journal of Radio Electronics
- Vol. 2025 (11)
Methods of triggering for pseudospark switch with the trigger unit based on an auxiliary glow
The present paper deals with the study of methods of triggering for the sealed-off pseudospark switch with a trigger unit based on an auxiliary glow discharge in conditions when the trigger pulse has a negative polarity. It is shown that the power supply scheme for auxiliary discharge sustainment and regimes of the discharge have a significant effect on the delay time of the switch triggering time relative to the instant of trigger pulse application and jitter. The causes of this effect are explained. The trigger schemes and auxiliary discharge power schemes, for which nanosecond stability of the switch operation is provided, have been revealed.
- 1 November 2025
- Published by Kotelnikov Institute of Radioengineering and Electronics of Russian Academy of Sciences in Journal of Radio Electronics
- Vol. 2025 (11)
Methods of triggering for pseudospark switch with the trigger unit based on an auxiliary glow
The present paper deals with the study of methods of triggering for the sealed-off pseudospark switch with a trigger unit based on an auxiliary glow discharge in conditions when the trigger pulse has a negative polarity. It is shown that the power supply scheme for auxiliary discharge sustainment and regimes of the discharge have a significant effect on the delay time of the switch triggering time relative to the instant of trigger pulse application and jitter. The causes of this effect are explained. The trigger schemes and auxiliary discharge power schemes, for which nanosecond stability of the switch operation is provided, have been revealed.
- 1 September 2025
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 89 (9) , 1652-1656
Formation of Gas Bubbles in Saline Solution in the Mode of Self-Oscillation of Current at Voltages Close to a Critical Value
The dynamics of the formation of vapor-filled bubbles arising from the discharge of an electric capacitance through an electrolyte with a positive polarity of the active electrode is investigated. The electrode system refers to a special case of the point-plane geometry when the length of the active electrode is zero. It is shown that at a voltage at an interelectrode gap of 500 V, self-oscillations of the current are observed. There is a correlation between the shape of the current and the sound wave from the liquid oscillation recorded by the pressure sensor. At the moment of starting and moment of termination of full shielding of the active electrode, a spark discharge ignited along the surface of the insulator.
- 1 September 2025
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 89 (9) , 1652-1656
Formation of Gas Bubbles in Saline Solution in the Mode of Self-Oscillation of Current at Voltages Close to a Critical Value
The dynamics of the formation of vapor-filled bubbles arising from the discharge of an electric capacitance through an electrolyte with a positive polarity of the active electrode is investigated. The electrode system refers to a special case of the point-plane geometry when the length of the active electrode is zero. It is shown that at a voltage at an interelectrode gap of 500 V, self-oscillations of the current are observed. There is a correlation between the shape of the current and the sound wave from the liquid oscillation recorded by the pressure sensor. At the moment of starting and moment of termination of full shielding of the active electrode, a spark discharge ignited along the surface of the insulator.
- 1 August 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (8) , 1285-1297
Development of the switching process in the pseudospark switch with a trigger unit based on auxiliary glow discharge
- 1 August 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (8) , 1285-1297
Development of the switching process in the pseudospark switch with a trigger unit based on auxiliary glow discharge
- 1 December 2023
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 87 (S2) , S269-S273
Mechanism of Triggering for the Pseudospark Switch with a Trigger Unit Based on Surface Discharge
Data on study of the pseudospark switch with the trigger unit based on the pulsed discharge over ceramic surface with a trigger voltage at a level of 3 kV and an anode voltage of 20 kV and are presented. The features of the surface discharge and the process of the discharge initiation and sustaining in the high-voltage gap are investigated. The total delay time to trigger the switch with respect to the instant of arrival of the trigger pulse can be changed in a range 40–60 ns. However, in all cases the nanosecond jitter in triggering is provided.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 87 (S2) , S269-S273
Mechanism of Triggering for the Pseudospark Switch with a Trigger Unit Based on Surface Discharge
Data on study of the pseudospark switch with the trigger unit based on the pulsed discharge over ceramic surface with a trigger voltage at a level of 3 kV and an anode voltage of 20 kV and are presented. The features of the surface discharge and the process of the discharge initiation and sustaining in the high-voltage gap are investigated. The total delay time to trigger the switch with respect to the instant of arrival of the trigger pulse can be changed in a range 40–60 ns. However, in all cases the nanosecond jitter in triggering is provided.
- 1 September 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (9)
Study of trigger mechanisms of a pseudospark switch configuration with a steady-state auxiliary glow discharge
This paper presents data on investigation of the pseudospark switch whose trigger unit uses a low-current auxiliary glow discharge with hollow cathode and hollow anode. The electrode system of this unit communicates with the main high-voltage gap of the switch due to the aperture in the flat part of one of the trigger electrodes. It is shown that when the electrode with the aperture plays of role of the hollow cathode of the auxiliary discharge, a low parasitic current through the aperture is provided by the ion flow. This ion current does not practically influence on the static breakdown voltage of the main gap. Applying the trigger pulse between the trigger electrodes leads to the pulsed trigger discharge with an enhanced current. At a negative polarity of the trigger pulse, the cavity with aperture turns out into the hollow anode so that the current is able to be intercepted through the aperture to the grounded cavity of the main gap. The plasma is generated in the cavity and the switch is triggered. With the proper selection of the geometry of the trigger electrodes, the delay time to trigger at a level of several tens of nanoseconds is achievable.
- 1 September 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (9)
Study of trigger mechanisms of a pseudospark switch configuration with a steady-state auxiliary glow discharge
This paper presents data on investigation of the pseudospark switch whose trigger unit uses a low-current auxiliary glow discharge with hollow cathode and hollow anode. The electrode system of this unit communicates with the main high-voltage gap of the switch due to the aperture in the flat part of one of the trigger electrodes. It is shown that when the electrode with the aperture plays of role of the hollow cathode of the auxiliary discharge, a low parasitic current through the aperture is provided by the ion flow. This ion current does not practically influence on the static breakdown voltage of the main gap. Applying the trigger pulse between the trigger electrodes leads to the pulsed trigger discharge with an enhanced current. At a negative polarity of the trigger pulse, the cavity with aperture turns out into the hollow anode so that the current is able to be intercepted through the aperture to the grounded cavity of the main gap. The plasma is generated in the cavity and the switch is triggered. With the proper selection of the geometry of the trigger electrodes, the delay time to trigger at a level of several tens of nanoseconds is achievable.
- 1 November 2022
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 31 (11) , 115013
Initial stages of pulsed discharge in saline solutions in a vicinity of threshold voltages
Data are presented on an investigation of pulsed discharges in a solution of 30 g of NaCl per liter of distilled water. The interelectrode gap consists of the active pin electrode and the return plane electrode. The voltage pulse of positive polarity forms by means of an electric circuit where a capacitor bank of 40 μ F with an initial voltage V 0 of up to 1500 V is discharged via the gap. In a range of initial voltages V 0 = (550 – 1100) V vapor cavities in a form of the microbubbles are generated near the active electrode and at the electrode surface. The microbubbles are able to merge with each other thus forming macrobubbles and vapor layers, which shield the active electrode from current passage. The process of vapor cavity generation and the effect of shielding are discussed in detail. The discharge at the vapor layer appears at the critical voltage V 0 = 1100 V. The principal prerequisite for discharge arising is that the electrode has to be completely shielded by the vapor layer and the voltage at the layer at the instant of discharge initiation has to be at least at a level of 500 V. However, when the voltage at the gap exceeds the critical value, the condition of complete shielding is not obligatory.
- 1 November 2022
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 31 (11) , 115013
Initial stages of pulsed discharge in saline solutions in a vicinity of threshold voltages
Data are presented on an investigation of pulsed discharges in a solution of 30 g of NaCl per liter of distilled water. The interelectrode gap consists of the active pin electrode and the return plane electrode. The voltage pulse of positive polarity forms by means of an electric circuit where a capacitor bank of 40 μ F with an initial voltage V 0 of up to 1500 V is discharged via the gap. In a range of initial voltages V 0 = (550 – 1100) V vapor cavities in a form of the microbubbles are generated near the active electrode and at the electrode surface. The microbubbles are able to merge with each other thus forming macrobubbles and vapor layers, which shield the active electrode from current passage. The process of vapor cavity generation and the effect of shielding are discussed in detail. The discharge at the vapor layer appears at the critical voltage V 0 = 1100 V. The principal prerequisite for discharge arising is that the electrode has to be completely shielded by the vapor layer and the voltage at the layer at the instant of discharge initiation has to be at least at a level of 500 V. However, when the voltage at the gap exceeds the critical value, the condition of complete shielding is not obligatory.
- 1 July 2022
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 31 (7) , 074002
Operating modes in a low-pressure glow discharge with hollow cathode
The paper deals with investigations of the discharge in hydrogen in conditions close to those for the trigger units of pseudospark switches. The following modes of discharge sustaining are classified: the Townsend discharge, the suppressed glow discharge with hollow cathode, the intermediate mode of the gradual transition from the suppressed discharge to the ordinary glow discharge, and the ordinary discharge in which the negative glow plasma occupies the whole depth of the cathode cavity. As applied to the ordinary discharge, the theoretical model that offers a possibility to estimate the negative glow parameters is developed. In the current range 1.6–10 mA the electron densities in the negative glow region are 1.7–8.7 10 8 cm −3 . The interpretation for the mechanism of the current passage to the anode is also proposed based on the model. In particular, the explanation is given for the fact that the region of the positive column plasma near the flat anode appears at a low discharge current.
- 1 July 2022
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 31 (7) , 074002
Operating modes in a low-pressure glow discharge with hollow cathode
The paper deals with investigations of the discharge in hydrogen in conditions close to those for the trigger units of pseudospark switches. The following modes of discharge sustaining are classified: the Townsend discharge, the suppressed glow discharge with hollow cathode, the intermediate mode of the gradual transition from the suppressed discharge to the ordinary glow discharge, and the ordinary discharge in which the negative glow plasma occupies the whole depth of the cathode cavity. As applied to the ordinary discharge, the theoretical model that offers a possibility to estimate the negative glow parameters is developed. In the current range 1.6–10 mA the electron densities in the negative glow region are 1.7–8.7 10 8 cm −3 . The interpretation for the mechanism of the current passage to the anode is also proposed based on the model. In particular, the explanation is given for the fact that the region of the positive column plasma near the flat anode appears at a low discharge current.
- 1 September 2020
- Published by Springer Nature in Russian Physics Journal
- Vol. 63 (5) , 809-817
Special Features of the Discharge Formation in the Trigger Unit Based on Breakdown Over the Semiconductor Surface in Sealed-Off Cold-Cathode Thyratron
- 1 September 2020
- Published by Springer Nature in Russian Physics Journal
- Vol. 63 (5) , 809-817
Special Features of the Discharge Formation in the Trigger Unit Based on Breakdown Over the Semiconductor Surface in Sealed-Off Cold-Cathode Thyratron