Sompob Polmai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sompob Polmai has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Toshifumi Ise
Osaka University, Japan
6 shared publicationsDarith Leng
Faculty of Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand
4 shared publicationsSadatoshi Kumagai
Osaka University, Japan
4 shared publicationsKittichot Soontorntaweesub
2 shared publicationsMasato Yamada
Kansai Electric Power Co., Japan
2 shared publicationsN. Pattanadech
Electrical Engineering department, Faculty of Engineering, King Mongkut's Institute of Technology Ladkrabang, Thailand
2 shared publications
Latest Publications
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Transient Respond Comparison Between Modified Droop Control and Virtual Synchronous Generator in Standalone Microgrid
The inverter-based distributed generator (DG) plays a major role to solve the worldwide energy demand increasing and the environmental concern. The DG which controls by traditionally grid-connected current control confront some problems such as lacking the grid-forming ability and inertia. Therefore, the DG could not operate in standalone, and the DG's penetration rate is limited. To address these issues, the control strategy which imitates the synchronous's generator characteristic called droop control and virtual synchronous generator (VSG) are proposed recently. Seeing the potential of both control; this paper aims to investigate the dynamic performance of modified droop control and VSG. A simulation model of parallel DGs supply to a group of the load in the form of a standalone microgrid is implemented in MATLAB/Simulink. Two case studies such as power-sharing and load transient are carried out. The results have shown that VSG provides the outperform compare to the modified droop control when a large load transition is applied.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Transient Respond Comparison Between Modified Droop Control and Virtual Synchronous Generator in Standalone Microgrid
The inverter-based distributed generator (DG) plays a major role to solve the worldwide energy demand increasing and the environmental concern. The DG which controls by traditionally grid-connected current control confront some problems such as lacking the grid-forming ability and inertia. Therefore, the DG could not operate in standalone, and the DG's penetration rate is limited. To address these issues, the control strategy which imitates the synchronous's generator characteristic called droop control and virtual synchronous generator (VSG) are proposed recently. Seeing the potential of both control; this paper aims to investigate the dynamic performance of modified droop control and VSG. A simulation model of parallel DGs supply to a group of the load in the form of a standalone microgrid is implemented in MATLAB/Simulink. Two case studies such as power-sharing and load transient are carried out. The results have shown that VSG provides the outperform compare to the modified droop control when a large load transition is applied.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Simplified Algorithm of Space Vector Modulation for Diode-Clamped Three-Level Inverter
This paper presents algorithm for three-level neutral-point-clamped (NPC) inverters space-vector modulation. The proposed method divides the reference vector locus into non-uniform six intervals in a sector and calculates on-times for switching state of each interval. The selection of switching sequence corresponds with the even harmonic elimination condition of fundamental frequency output. The dwell-time calculation is based on transforming three-level vector to two-level vector for simplicity. The results of implementation using the low-cost microcontroller test-set with a three-phase induction motor show that the three-phase three-level inverter can operate successfully.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A Simplified Algorithm of Space Vector Modulation for Diode-Clamped Three-Level Inverter
This paper presents algorithm for three-level neutral-point-clamped (NPC) inverters space-vector modulation. The proposed method divides the reference vector locus into non-uniform six intervals in a sector and calculates on-times for switching state of each interval. The selection of switching sequence corresponds with the even harmonic elimination condition of fundamental frequency output. The dwell-time calculation is based on transforming three-level vector to two-level vector for simplicity. The results of implementation using the low-cost microcontroller test-set with a three-phase induction motor show that the three-phase three-level inverter can operate successfully.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Low Voltage Series Arc Fault Detection Using Rogowski Coil
This paper presents series arc fault detection in low voltage ac circuit using Rogowski coil di/dt sensor. Series arc faults are simulated with various types of loads and current levels to understand the characteristic of arcing signal pattern and level. The Rogowski coil is designed to be able to detect high frequency di/dt component of the arc signal. The experimental results clearly show that by detecting the high frequency component of the di/dt, series arc fault condition can be reliably detected.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Low Voltage Series Arc Fault Detection Using Rogowski Coil
This paper presents series arc fault detection in low voltage ac circuit using Rogowski coil di/dt sensor. Series arc faults are simulated with various types of loads and current levels to understand the characteristic of arcing signal pattern and level. The Rogowski coil is designed to be able to detect high frequency di/dt component of the arc signal. The experimental results clearly show that by detecting the high frequency component of the di/dt, series arc fault condition can be reliably detected.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 122-127
Multi-agent system based real-time control for standalone microgrid
The energy crisis and environmental concern lead to widely use of renewable energy sources in form of microgrid. The intermittent nature of the microgrid's sources and the altering behaviors of loads result to unstable of the system's voltage and frequency as well as the system reliability. The purpose of this paper is to develop real-time control based decentralizing technique for handling the challenging issues of the microgrid. Two levels distributed control is proposed. A modify droop control and frequency restoration is implemented as low-level control. The upper-level, a multiagent system is developed and it is the main control method in the research. The agents are implemented using Boris based on C#.NET language. The multiagent system consists of four main agents such as CONTROL agent, DER Agent, RENEW agent and LOAD agent. To evaluate the control performance, the microgrid testbed has been built. The results prove the effectiveness of real-time control to stabilize, monitor, improve system reliability and provide the microgrid intelligent operation.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 122-127
Multi-agent system based real-time control for standalone microgrid
The energy crisis and environmental concern lead to widely use of renewable energy sources in form of microgrid. The intermittent nature of the microgrid's sources and the altering behaviors of loads result to unstable of the system's voltage and frequency as well as the system reliability. The purpose of this paper is to develop real-time control based decentralizing technique for handling the challenging issues of the microgrid. Two levels distributed control is proposed. A modify droop control and frequency restoration is implemented as low-level control. The upper-level, a multiagent system is developed and it is the main control method in the research. The agents are implemented using Boris based on C#.NET language. The multiagent system consists of four main agents such as CONTROL agent, DER Agent, RENEW agent and LOAD agent. To evaluate the control performance, the microgrid testbed has been built. The results prove the effectiveness of real-time control to stabilize, monitor, improve system reliability and provide the microgrid intelligent operation.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1165-1169
Generalized regression networks for partial discharge classification
This document represents a partial discharge (PD) classification by using Generalized Regression Networks (GRNN) model. Two PD classification models, GRNN1 with 11 input variables and GRNN2 with 3 selected derived statistic parameters, were investigated for classification of PD signals into 5 patterns, corona at high voltage side in air, corona at low voltage side in air, corona at high voltage side in mineral oil, corona at low voltage side in mineral oil and surface discharge in mineral oil. The conventional PD measurement was performed for measuring PD signals of the artificial PD models. The statistical parameters of the PD signals such as skewness, kurtosis, asymmetry, cross correlation and so on were calculated from the developed computer program. Then, 60% of the experimented data was used as a training data for the developed PD classification models. Another 40% experimented data was used to evaluate the performance of the designed PD classification models. It was found that the GRNN1 model can classify PD patterns better than GRNN2 model. The accuracy for PD classification of GRNN1 model was 100% while the accuracy of GRNN2 model was 97.5% of 40 testing data.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1165-1169
Generalized regression networks for partial discharge classification
This document represents a partial discharge (PD) classification by using Generalized Regression Networks (GRNN) model. Two PD classification models, GRNN1 with 11 input variables and GRNN2 with 3 selected derived statistic parameters, were investigated for classification of PD signals into 5 patterns, corona at high voltage side in air, corona at low voltage side in air, corona at high voltage side in mineral oil, corona at low voltage side in mineral oil and surface discharge in mineral oil. The conventional PD measurement was performed for measuring PD signals of the artificial PD models. The statistical parameters of the PD signals such as skewness, kurtosis, asymmetry, cross correlation and so on were calculated from the developed computer program. Then, 60% of the experimented data was used as a training data for the developed PD classification models. Another 40% experimented data was used to evaluate the performance of the designed PD classification models. It was found that the GRNN1 model can classify PD patterns better than GRNN2 model. The accuracy for PD classification of GRNN1 model was 100% while the accuracy of GRNN2 model was 97.5% of 40 testing data.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1176-1180
Partial discharge classification using probabilistic neural network model
The aim of this paper is to propose the probabilistic neural network (PNN) model for classification partial discharge (PD) patterns, which comprised of corona discharge at high voltage side and at low voltage side in air, corona discharge at high voltage side and at low voltage side in mineral oil and surface discharge in mineral oil. Partial discharge signals were investigated by conventional method according to IEC60270. Independent parameters such as skewness, kurtosis, asymmetry, and cross correlation of the Φ-q-n PD patterns were analyzed. The PNN PD classification model was constructed. Moreover, the principal component analysis (PCA) was utilized to reduce the input dimension of the developed PD classification model. After that, 60% of the experimented data was used as a training data for the PD classification models. Another 40% experimented data was used for evaluation the performance of the designed PD classification models. Effects of spread parameters and input neuron numbers on the PD classification performance were examined. It was found that the first four score variable was appropriate to be used to construct the designed PNN model with the optimal spread value of 1.2. The proposed PD classification model can classify PD types with the accuracy of 100% of 40 tested data.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1176-1180
Partial discharge classification using probabilistic neural network model
The aim of this paper is to propose the probabilistic neural network (PNN) model for classification partial discharge (PD) patterns, which comprised of corona discharge at high voltage side and at low voltage side in air, corona discharge at high voltage side and at low voltage side in mineral oil and surface discharge in mineral oil. Partial discharge signals were investigated by conventional method according to IEC60270. Independent parameters such as skewness, kurtosis, asymmetry, and cross correlation of the Φ-q-n PD patterns were analyzed. The PNN PD classification model was constructed. Moreover, the principal component analysis (PCA) was utilized to reduce the input dimension of the developed PD classification model. After that, 60% of the experimented data was used as a training data for the PD classification models. Another 40% experimented data was used for evaluation the performance of the designed PD classification models. Effects of spread parameters and input neuron numbers on the PD classification performance were examined. It was found that the first four score variable was appropriate to be used to construct the designed PNN model with the optimal spread value of 1.2. The proposed PD classification model can classify PD types with the accuracy of 100% of 40 tested data.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Experiment on distributed cooperative control with multi-agent system for a single-phase microgrid
In a microgrid, electric generation is based on combination of small generators and renewable resources such as solar and wind. The operating conditions of the microgrid are dynamically altered by both the load and the intermittent nature of the renewable resources. To maintain the voltage and frequency stability of such microgrid, this paper presents distributed cooperative control of a microgrid using multi-agent system. The multi-agent system is implemented by using Mobile-C based on Client-Server architecture, and Ch and Embedded Ch as the agents run time. Serial communication is implemented for data exchange between agents and microgrid elements. To validate the effectiveness of the proposed control system, two scenarios have been experimented. The experimental results demonstrate the generator connecting/disconnecting and load shedding ability of the microgrid.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Experiment on distributed cooperative control with multi-agent system for a single-phase microgrid
In a microgrid, electric generation is based on combination of small generators and renewable resources such as solar and wind. The operating conditions of the microgrid are dynamically altered by both the load and the intermittent nature of the renewable resources. To maintain the voltage and frequency stability of such microgrid, this paper presents distributed cooperative control of a microgrid using multi-agent system. The multi-agent system is implemented by using Mobile-C based on Client-Server architecture, and Ch and Embedded Ch as the agents run time. Serial communication is implemented for data exchange between agents and microgrid elements. To validate the effectiveness of the proposed control system, two scenarios have been experimented. The experimental results demonstrate the generator connecting/disconnecting and load shedding ability of the microgrid.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2426-2430
Reactive power and harmonics compensation using a flying capacitor multilevel inverter
The closed-loop current control is designed and applied to force the inverter to inject the compensating reactive power and harmonics into the system. A five-level inverter is modeled and the phase-shifted pulse width modulation technique is adopted for output voltage control. The simulation results show the proposed flying capacitor inverter is capable of compensating for load reactive power and load harmonics.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2426-2430
Reactive power and harmonics compensation using a flying capacitor multilevel inverter
The closed-loop current control is designed and applied to force the inverter to inject the compensating reactive power and harmonics into the system. A five-level inverter is modeled and the phase-shifted pulse width modulation technique is adopted for output voltage control. The simulation results show the proposed flying capacitor inverter is capable of compensating for load reactive power and load harmonics.