Fredy Bernal Castillo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fredy Bernal Castillo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Carlos Cabrera Cabrera
Universidad Militar Nueva Granada
1 shared publicationG. Roa-Rodríguez
Universidad Militar Nueva Granada, Bogotá, Colombia
1 shared publicationGuillermo Roa Rodríguez
Universidad Militar Nueva Granada
1 shared publicationIng. Andrés Cifuentes
Universidad Militar Nueva Granada
1 shared publicationIng. Mauricio Plaza Torres
Universidad Militar Nueva Granada
1 shared publication- Mauricio Plaza
Centro de Biomecánica, Universidad Militar Nueva Granada, Bogotá D.C. 110231, Colombia
1 shared publication
Latest Publications
- Open Access
Kinect-Based Gait Analysis System Design and Concurrent Validity in Persons with Anterolateral Shoulder Pain Syndrome, Results from a Pilot Study
As part of an investigation to detect asymmetries in gait patterns in persons with shoulder injuries, the goal of the present study was to design and validate a Kinect-based motion capture system that would enable the extraction of joint kinematics curves during gait and to compare them with the data obtained through a commercial motion capture system. The study included eight male and two female participants, all diagnosed with anterolateral shoulder pain syndrome in their right upper extremity with a minimum 18 months of disorder evolution. The participants had an average age of 31.8 ± 9.8 years, a height of 173 ± 18 cm, and a weight of 81 ± 15 kg. The gait kinematics were sampled simultaneously with the new system and the Clinical 3DMA system. Shoulder, elbow, hip, and knee kinematics were compared between systems for the pathological and non-pathological sides using repeated measures ANOVA and 1D statistical parametric mapping. For most variables, no significant difference was found between systems. Evidence of a significant difference between the newly developed system and the commercial system was found for knee flexion–extension (p < 0.004, between 60 and 80% of the gait cycle), and for shoulder abduction–adduction. The good concurrent validity of the new Kinect-based motion analysis system found in this study opens promising perspectives for clinical motion tracking using an affordable and simple system.
Open AccessKinect-Based Gait Analysis System Design and Concurrent Validity in Persons with Anterolateral Shoulder Pain Syndrome, Results from a Pilot Study
As part of an investigation to detect asymmetries in gait patterns in persons with shoulder injuries, the goal of the present study was to design and validate a Kinect-based motion capture system that would enable the extraction of joint kinematics curves during gait and to compare them with the data obtained through a commercial motion capture system. The study included eight male and two female participants, all diagnosed with anterolateral shoulder pain syndrome in their right upper extremity with a minimum 18 months of disorder evolution. The participants had an average age of 31.8 ± 9.8 years, a height of 173 ± 18 cm, and a weight of 81 ± 15 kg. The gait kinematics were sampled simultaneously with the new system and the Clinical 3DMA system. Shoulder, elbow, hip, and knee kinematics were compared between systems for the pathological and non-pathological sides using repeated measures ANOVA and 1D statistical parametric mapping. For most variables, no significant difference was found between systems. Evidence of a significant difference between the newly developed system and the commercial system was found for knee flexion–extension (p < 0.004, between 60 and 80% of the gait cycle), and for shoulder abduction–adduction. The good concurrent validity of the new Kinect-based motion analysis system found in this study opens promising perspectives for clinical motion tracking using an affordable and simple system.
- Open Access
- 21 December 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 272 (1) , 012001
Movement Intention Prediction to Find a New Exoskeleton Design with Light and Comfortable Materials
This paper presents a discussion about the design a novel exoskeleton and the implementation of superficial magnetic sensor and pressure sensor for find patterns and parameters in order to predicting the intention of movement for people with musculoskeletal system problem in lower limbs. The information is obtained through reading position and movement by magnetic and pressure sensor installed in different parts of the body. The advantage of this sensor is the location of the position reference of the every part of the body. Using the sensor in some parts of the body is possible to calculate the muscle contraction for the prediction of intended movement and to find a new design with light and comfortable materials.
- 21 December 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 272 (1) , 012001
Open AccessMovement Intention Prediction to Find a New Exoskeleton Design with Light and Comfortable Materials
This paper presents a discussion about the design a novel exoskeleton and the implementation of superficial magnetic sensor and pressure sensor for find patterns and parameters in order to predicting the intention of movement for people with musculoskeletal system problem in lower limbs. The information is obtained through reading position and movement by magnetic and pressure sensor installed in different parts of the body. The advantage of this sensor is the location of the position reference of the every part of the body. Using the sensor in some parts of the body is possible to calculate the muscle contraction for the prediction of intended movement and to find a new design with light and comfortable materials.
- 1 December 2016
- Published by Springer Nature in MRS Proceedings
- Vol. 1815
Remote Measurement of Linear Polarization Resistance In Concrete Structures
- 1 December 2016
- Published by Springer Nature in MRS Proceedings
- Vol. 1815
Remote Measurement of Linear Polarization Resistance In Concrete Structures
- Open Access
- 1 January 2015
- Published by Universidad ECCI in TECCIENCIA
- Vol. 10 (19) , 27-32
Determination of the probability and rate of corrosion on reinforced
In this paper, we present the design and construction of a remote monitoring system for determining the probability and rate of corrosion of rebar embedded in concrete. We use the ASTM standard C876 technique for the probability of corrosion and the Linear Polarization Resistance method to indirectly obtain the rate of corrosion. The system consists of a communication module using GSM and GPRS cellular networks which provide remote measurements. The device was used to evaluate corrosion with reference electrodes of copper/copper sulfate and graphite on Type I Portland cement specimens of 15cm in diameter and 30cm in length. The results of the measurements were compared to a commercial system, revealing similar values to the data obtained in the field and the laboratory.
- 1 January 2015
- Published by Universidad ECCI in TECCIENCIA
- Vol. 10 (19) , 27-32
Open AccessDetermination of the probability and rate of corrosion on reinforced
In this paper, we present the design and construction of a remote monitoring system for determining the probability and rate of corrosion of rebar embedded in concrete. We use the ASTM standard C876 technique for the probability of corrosion and the Linear Polarization Resistance method to indirectly obtain the rate of corrosion. The system consists of a communication module using GSM and GPRS cellular networks which provide remote measurements. The device was used to evaluate corrosion with reference electrodes of copper/copper sulfate and graphite on Type I Portland cement specimens of 15cm in diameter and 30cm in length. The results of the measurements were compared to a commercial system, revealing similar values to the data obtained in the field and the laboratory.