Monika Wiśnik-Sawka

Monika Wiśnik-Sawka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Monika Wiśnik-Sawka has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Bedside analysis of volatile organic compounds in exhaled human breath as non-invasive diagnostic tool for colon diseases

    by Jakub Pietrzak, Monika Wiśnik-Sawka, Mirosław Maziejuk, Krzysztof Kucharczyk, Adam Przybyłkowski

  • Open Access

    Electrochemical Immunodetection of Bacillus anthracis Spores

    by Karolina Morawska, Tomasz Sikora, Aleksandra Nakonieczna, Renata Tyśkiewicz, Monika Wiśnik-Sawka, Łukasz Osuchowski, Paulina Osuchowska, Michał Grabka, Zygfryd Witkiewicz

    The Centers for Disease Control and Prevention (CDC) classifies Bacillus anthracis as one of the most dangerous pathogens that may affect public health and national security. Due to its importance as a potential biological weapon, this bacteria has been classified in the highest category A, together with such pathogens as variola virus or botulinum neurotoxin. Characteristic features of this pathogen that increase its military importance are the ease of its cultivation, transport, and storage and its ability to create survival forms that are extremely resistant to environmental conditions. However, beyond bioterrorism, B. anthracis is also a naturally occurring pathogen. Anthrax outbreaks occur in livestock and wildlife, particularly in spore-contaminated regions of Africa, Asia, and North America. Spores persist for decades, leading to recurrent infections and zoonotic transmission through direct contact, inhalation, or consumption of contaminated meat. This work presents a new electrochemical method for detecting and quantifying B. anthracis in spore form using a selective immune reaction. The developed method is based on the thiol-modified electrodes that constitute the sensing element of the electrochemical system. Tests with the B. anthracis spore suspension showed that the detection limit for this pathogen is as low as 103 CFU/mL. Furthermore, it was possible to quantify the analyte with a sensitivity of 11 mV/log (CFU/mL). Due to several features, such as low unit cost, portability, and minimal apparatus demands, this method can be easily implemented in field analyzers for this pathogen and provides an alternative to currently used techniques and devices.


  • Open Access

    Innovative Supported Membranes for Ion Mobility Spectrometer (IMS) Sample Introduction Systems with High Permeability Relative to Toxic Agents in Air (TAAs)

    by Monika Wiśnik-Sawka, Wojciech Fabianowski, Dorota Gajda

    One of the main objectives of the ion mobility spectrometry (IMS) technique is to reduce moisture in detection systems, which causes the formation of ion clusters and ion water and a reduction in formed clusters’ activity. Thus, one of the methods limiting moisture in a sampling injection system is to use hydrophobic polymeric membranes. The use of membranes with high permeability relative to the analysed organic compounds is required, including toxic agents in air (TAAs). Such requirements align with those of polydimethylsiloxane (PDMS) membranes. Unfortunately, thin PDMS membranes are not mechanically resistant. In this study, relatively thin PDMS membranes were reinforced with fine mesh fabric supports. These supports were chemically modified with selected oligoglycol derivatives and finally coated with PDMS. The obtained membranes were tested for water permeability and TAA simulants.


  • Open Access

    Air Pollution and Radiation Monitoring in Collective Protection Facilities

    by Angelika Monika Kołacz, Monika Wiśnik-Sawka, Mirosław Maziejuk, Marek Natora, Władyslaw Harmata, Paweł Rytel, Dorota Gajda

    It has become increasingly important to monitor environment contamination by such chemicals as chemical warfare agents (CWAs) and industrial toxic chemicals (TICs), as well as radiation hazards around and inside collective protection facilities. This is especially important given the increased risk of terrorist or military attacks. The Military Institute of Chemistry and Radiometry (MICR) has constructed and developed the ALERT device for the effective monitoring of these threats. This device uses sensors that detect chemical and radiological contaminations in the air. The CWA detector is an ion mobility spectrometer, TICs are detected by electrochemical sensors, and radiation hazards are detected via Geiger–Muller tubes. The system was designed to protect the crew from contamination. When chemical or radioactive contamination is detected at the air inlet for the shelter, air filtration through a carbon filter is activated. At this time, the air test procedure at the filter outlet is started to test the condition of the filter on an ongoing basis. After detecting contamination at the filter outlet, the system turns off the air pumping and the service can start the procedure of replacing the damaged carbon filter. This paper presents the results of laboratory testing of the ALERT gas alarm detector, which showed high measurements for important parameters, including sensitivity, repeatability, accuracy, and speed.


  • Open Access

    Detection and Identification of VOCs Using Differential Ion Mobility Spectrometry (DMS)

    by Wojciech Fabianowski, Mirosław Maziejuk, Monika Szyposzyńska, Monika Wiśnik-Sawka

    The article presents a technique of differential ion mobility spectrometry (DMS) applicable to the detection and identification of volatile organic compounds (VOCs) from such categories as n-alkanes, alcohols, acetate esters, ketones, botulinum toxin, BTX, and fluoro- and chloro-organic compounds. A possibility of mixture identification using only the DMS spectrometer is analyzed, and several examples are published for the first time. An analysis of different compounds and their mechanisms of fragmentation, influence on effective ion temperature, and high electric field intensity is discussed.


  • Open Access

    Detection of Triacetone Triperoxide (TATP) and Hexamethylene Triperoxide Diamine (HMTD) from the Gas Phase with Differential Ion Mobility Spectrometry (DMS)

    by Mirosław Maziejuk, Monika Szyposzyńska, Aleksandra Spławska, Monika Wiśnik-Sawka, Michał Ceremuga

    One of the significant problems in the modern world is the detection of improvised explosives made of materials synthesized at home. Such compounds include triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD). An attempt was made to construct an instrument allowing for the simultaneous detection of both compounds despite the large difference of vapor pressure: very high for TATP and very low for HMTD. The developed system uses differential ion mobility spectrometry (DMS) in combination with a specially designed gas sample injection system. The created system of detectors allowed for the detection of a high concentration of TATP and a very low concentration of HMTD. TATP detection was possible despite the presence of impurities—acetone remaining from the technological process and formed as a coproduct of diacetone diperoxide (DADP) synthesis. Ammonia added to the carrier gas improved the possibility of detecting the abovementioned explosives, reducing the intensity of the acetone signal. The obtained results were then compared with the detection capabilities of drift tube ion mobility spectrometer (DT-IMS), which has not made possible such detection as DMS.


  • Open Access

    Capillary Sensor for Detection of Amphetamine Precursors in Sewage Water

    by Monika Wiśnik-Sawka, Mirosław Maziejuk, Wojciech Fabianowski, Urszula Karpińska, Maciej Szwast, Jerzy Weremczuk

    This paper deals with the problem of detecting benzyl methyl ketone (BMK), which is a precursor of amphetamine that can be synthesized in home labs. The focus of our work was to identify an improvement for the analysis of sewage introduced into the municipal sewage system. The sensors used to detect BKM in these systems are often clogged and therefore cannot function properly. In this article, a new method of detecting BMK and other chemicals in wastewater is presented. A system containing capillary polypropylene, hydrophobized with polysiloxane coating fibers was prepared. These solutions were used for continuous online measurements by ion mobility spectrometry. The use of pipes with a polysiloxane coating reduces the permeation of water and significantly increases the BMK permeation due to its high solubility in the polymer.


  • Open Access

    Application of Ion Mobility Spectrometry for Permeability Studies of Organic Substances through Polymeric Materials

    by Monika Wiśnik-Sawka, Edyta Budzyńska, Jarosław Puton

    Drift tube ion mobility spectrometers (DT IMS) allow the concentration of different organic compounds to be measured. This gives the opportunity to use these detectors in measuring the penetration of various substances through polymer membranes. Permeation measurements of two substances (2-heptanone and dimethyl methylphosphonate (DMMP)) through a cylindrical silicone rubber membrane were carried out. The membrane separated the aqueous solution from the air. The analyte was introduced into water, and then its concentration in air on the opposite side of the membrane was recorded. Based on the dynamics of detector signal changes, the diffusion coefficients for both tested substances were determined. Determination of permeability coefficients was based on precise quantitative measurements, which took into account the non-linearity of the detector characteristics and the effect of water on detection sensitivity. The analysis of measurement results was based on a mathematical description of diffusion process.


  • Ion mobility spectrometers and electron capture detector – A comparison of detection capabilities

    by Edyta Budzyńska, Michał Grabka, Janina Kopyra, Mirosław Maziejuk, Zahra Safaei, Bartłomiej Fliszkiewicz, Monika Wiśnik, Jarosław Puton