Bambang Ariantara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Bambang Ariantara has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Nandy Putra
Universitas Indonesia
6 shared publications Nandy Putra
4 shared publicationsMuhammad Amin
3 shared publicationsNasruddin A. Abdullah
2 shared publicationsAdi Winarta
Applied Heat Transfer Research Group, Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus Baru-Depok, Jawa Barat, 16424
1 shared publicationAdjie Fahrizal Sandi
Applied Heat Transfer Research Group, Department of Mechanical, Faculty of Engineering, Universitas Indonesia, Kampus Baru- Depok, Jawa Barat, 16424, Indonesia
1 shared publication
Latest Publications
- 1 April 2019
- Published by Elsevier in Journal of Energy Storage
- Vol. 22, 331-335
Development of a novel thermoelectric module based device for thermal stability measurement of phase change materials
- 1 April 2019
- Published by Elsevier in Journal of Energy Storage
- Vol. 22, 331-335
Development of a novel thermoelectric module based device for thermal stability measurement of phase change materials
- Open Access
- 26 November 2018
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 67, 03034
Thermal Management of Electric Vehicle Batteries Using Heat Pipe and Phase Change Materials
The performance of an electric vehicle depends on the battery used. While, in the operation of an electric vehicle, batteries experience a quick heating especially at the beginning of charging and could cause a fire. Therefore, the solution could be proposed is by employing heat pipe and Phase Change Material (PCM) for cooling of battery. The heat pipe serves to transfer the battery’s heat energy. In other hands, PCM functions as a heat sink when the battery runs, so its performance will stable and extend the lifespan. This study aimed to evaluate the performance of electric vehicle batteries at a temperature of 50°C using the combination of heat pipe and PCM. The ‘L’ type of heat pipe and beeswax PCM were assembled as cooling device. In addition, a battery simulator was employed as a test instrument by varying the heat load of 20, 30, 40, and 50 W. The experiments were successfully conducted, and the results showed that the addition of heat pipe and PCM could keep the surface temperature of battery below 50°C, at heat load of 20 - 50 W. Heat pipe and PCM for battery’s cooling system, can reduce the battery surface temperature significantly and can be proposed as an alternative system for cooling battery.
- 26 November 2018
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 67, 03034
Open AccessThermal Management of Electric Vehicle Batteries Using Heat Pipe and Phase Change Materials
The performance of an electric vehicle depends on the battery used. While, in the operation of an electric vehicle, batteries experience a quick heating especially at the beginning of charging and could cause a fire. Therefore, the solution could be proposed is by employing heat pipe and Phase Change Material (PCM) for cooling of battery. The heat pipe serves to transfer the battery’s heat energy. In other hands, PCM functions as a heat sink when the battery runs, so its performance will stable and extend the lifespan. This study aimed to evaluate the performance of electric vehicle batteries at a temperature of 50°C using the combination of heat pipe and PCM. The ‘L’ type of heat pipe and beeswax PCM were assembled as cooling device. In addition, a battery simulator was employed as a test instrument by varying the heat load of 20, 30, 40, and 50 W. The experiments were successfully conducted, and the results showed that the addition of heat pipe and PCM could keep the surface temperature of battery below 50°C, at heat load of 20 - 50 W. Heat pipe and PCM for battery’s cooling system, can reduce the battery surface temperature significantly and can be proposed as an alternative system for cooling battery.
- Open Access
- 26 November 2018
- Published by EDP Sciences
- Vol. 67, 03035
Thermal performance of Pulsating Heat Pipe on Electric Motor as Cooling Application
Heat generated in an electric motor can increase the operating temperature. The excessive operating temperature will reduce the electric motor performance and shorten the service life. An appropriate thermal management system is required to reduce the electric motor operating temperature. The objective of this study is to determine the thermal performance of pulsating heat pipes which applied to the electric motor thermal management system. A prototype of electric motor thermal management system was made from an induction motor with a cartridge heater instead of a heat-generating rotor and stator. Six pieces of pulsating heat pipe were mounted using hexagonal heat pipe holder which placed inside the electric motor housing. The pulsating heat pipes are made of a copper capillary tube using acetone as working fluid with a filling ratio of 0.5. The electric power input was varied from 30 W to 150 W. The use of pulsating heat pipes can reduce the electric motor surface temperature by 55.3°C with the minimum thermal resistance of 0.151°C/W.
- 26 November 2018
- Published by EDP Sciences
- Vol. 67, 03035
Open AccessThermal performance of Pulsating Heat Pipe on Electric Motor as Cooling Application
Heat generated in an electric motor can increase the operating temperature. The excessive operating temperature will reduce the electric motor performance and shorten the service life. An appropriate thermal management system is required to reduce the electric motor operating temperature. The objective of this study is to determine the thermal performance of pulsating heat pipes which applied to the electric motor thermal management system. A prototype of electric motor thermal management system was made from an induction motor with a cartridge heater instead of a heat-generating rotor and stator. Six pieces of pulsating heat pipe were mounted using hexagonal heat pipe holder which placed inside the electric motor housing. The pulsating heat pipes are made of a copper capillary tube using acetone as working fluid with a filling ratio of 0.5. The electric power input was varied from 30 W to 150 W. The use of pulsating heat pipes can reduce the electric motor surface temperature by 55.3°C with the minimum thermal resistance of 0.151°C/W.
- Open Access
- 19 November 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 432 (1) , 012001
Development of lotus-type porous material for heat pipe application using centrifugal slip casting process
Heat pipe is a heat conductor which has a large conduction capacity using a special fluid-filled pipe as a conductor of heat from the hot end (evaporator) to the cold end (condenser) used for thermal management. In the heat pipe, there is a sintered wick which transfers refrigerant fluid from condenser to evaporator. The objective of this research is to improve capillary performance by making a straight pore called as lotus-type porous material (LTP) using centrifugal slip casting technique. Copper powder is used as wick materials due to its high thermal conductivity. A starch solution is used as binder material to make the copper slurry. Nylon wire is applied as straight pore mold. Freeze drying is applied to curing and demolding. Vacuum sintering is conducted to increase metallurgical bonding between the particle. The results show that centrifugal casting machine is capable to make a wick with LTP structure. On the performance department, capillary pumping is affected by rotation speed, powder size, and powder loading. The optimum parameters were copper powder with 260.54 μm powder size, 50% Powder Loading with 688 rpm rotation speed. The LTP wick is proved to have a higher capillary pumping capacity compared to the conventional wick. Further work is necessary to verify the performance of LTP wick in the heat pipe.
- 19 November 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 432 (1) , 012001
Open AccessDevelopment of lotus-type porous material for heat pipe application using centrifugal slip casting process
Heat pipe is a heat conductor which has a large conduction capacity using a special fluid-filled pipe as a conductor of heat from the hot end (evaporator) to the cold end (condenser) used for thermal management. In the heat pipe, there is a sintered wick which transfers refrigerant fluid from condenser to evaporator. The objective of this research is to improve capillary performance by making a straight pore called as lotus-type porous material (LTP) using centrifugal slip casting technique. Copper powder is used as wick materials due to its high thermal conductivity. A starch solution is used as binder material to make the copper slurry. Nylon wire is applied as straight pore mold. Freeze drying is applied to curing and demolding. Vacuum sintering is conducted to increase metallurgical bonding between the particle. The results show that centrifugal casting machine is capable to make a wick with LTP structure. On the performance department, capillary pumping is affected by rotation speed, powder size, and powder loading. The optimum parameters were copper powder with 260.54 μm powder size, 50% Powder Loading with 688 rpm rotation speed. The LTP wick is proved to have a higher capillary pumping capacity compared to the conventional wick. Further work is necessary to verify the performance of LTP wick in the heat pipe.
- Open Access
- 24 January 2018
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 105 (1) , 012045
Battery thermal management system using loop heat pipe with LTP copper capillary wick
Loop heat pipes (LHPs) with Lotus-Type Porous Copper (LTP Copper) capillary wick are expected to be applied to battery thermal management systems for safe operation at high performance with a long service life. Sintered LTP Copper is a high permeability porous metal with an excellent capillary pumping characteristic. The objective of this work is to determine the performance of the battery thermal management system using LHP with sintered LTP Copper capillary wick experimentally. The experiment used two battery simulators made of aluminum. The heat generation of the battery was simulated using cartridge heaters. The LHP was made of 10 m OD copper tube, and the sintered LTP Copper capillary wick was placed in the liquid line. Water was used as working fluid with filling ratio of 50%. The evaporator section of the LHP was inserted between the battery simulators surfaces. A thermostatic bath was used to regulate the condenser cooling fluid temperature. K-type 0.3 mm thermocouples were used for temperature measurement, and a digital power meter was used to measure the electric power. Experiments were conducted with various heating power with the condenser cooling fluid temperature was kept at 28°C. At a heat generation of 20 W, the LHP was capable of maintaining the battery surface temperature below 50°C. At a heat generation of 40 W, the utilization of LHP with LTP Copper can reduce the average battery simulator surface temperature from 93°C to 65°C.
- 24 January 2018
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 105 (1) , 012045
Open AccessBattery thermal management system using loop heat pipe with LTP copper capillary wick
Loop heat pipes (LHPs) with Lotus-Type Porous Copper (LTP Copper) capillary wick are expected to be applied to battery thermal management systems for safe operation at high performance with a long service life. Sintered LTP Copper is a high permeability porous metal with an excellent capillary pumping characteristic. The objective of this work is to determine the performance of the battery thermal management system using LHP with sintered LTP Copper capillary wick experimentally. The experiment used two battery simulators made of aluminum. The heat generation of the battery was simulated using cartridge heaters. The LHP was made of 10 m OD copper tube, and the sintered LTP Copper capillary wick was placed in the liquid line. Water was used as working fluid with filling ratio of 50%. The evaporator section of the LHP was inserted between the battery simulators surfaces. A thermostatic bath was used to regulate the condenser cooling fluid temperature. K-type 0.3 mm thermocouples were used for temperature measurement, and a digital power meter was used to measure the electric power. Experiments were conducted with various heating power with the condenser cooling fluid temperature was kept at 28°C. At a heat generation of 20 W, the LHP was capable of maintaining the battery surface temperature below 50°C. At a heat generation of 40 W, the utilization of LHP with LTP Copper can reduce the average battery simulator surface temperature from 93°C to 65°C.
- 1 November 2017
- Published by Elsevier in Applied Thermal Engineering
- Vol. 126, 1156-1163
Electric motor thermal management system using L-shaped flat heat pipes
- 1 November 2017
- Published by Elsevier in Applied Thermal Engineering
- Vol. 126, 1156-1163
Electric motor thermal management system using L-shaped flat heat pipes
- 13 October 2017
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 41 (8) , 593-599
The use of beeswax as heating element in non-electric infant incubator
Non-electric infant incubators are needed in remote areas that have no access to electricity to reduce infant mortality nationwide. In previous studies, non-electric infant incubators have been developed using phase change material of beeswax as the heating element. This study aims to improve the performance of beeswax non-electric infant incubator to obtain a more reliable and practical one. The design of the original beeswax cartridge in the form of copper boxes was modified into tubes of stainless steel. The geometry and location of the air holes were also modified. Wood that was previously used as the body material was replaced with polyurethane to reduce the weight of the incubator. The beeswax cartridges were heated using boiling water until the beeswax melted. For temperature measurement, five 0.5 mm k-type thermocouples were placed inside of the incubator according to the National Industrial Standard of SNI 16-4221. The beeswax cartridge arrangement was varied to obtain the best performance. The results showed that polyurethane provides infant incubator lighter and more practical to use. The new design of non-electric infant incubator was capable of providing a temperature of 32-36 °C for 2 h.
- 13 October 2017
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 41 (8) , 593-599
The use of beeswax as heating element in non-electric infant incubator
Non-electric infant incubators are needed in remote areas that have no access to electricity to reduce infant mortality nationwide. In previous studies, non-electric infant incubators have been developed using phase change material of beeswax as the heating element. This study aims to improve the performance of beeswax non-electric infant incubator to obtain a more reliable and practical one. The design of the original beeswax cartridge in the form of copper boxes was modified into tubes of stainless steel. The geometry and location of the air holes were also modified. Wood that was previously used as the body material was replaced with polyurethane to reduce the weight of the incubator. The beeswax cartridges were heated using boiling water until the beeswax melted. For temperature measurement, five 0.5 mm k-type thermocouples were placed inside of the incubator according to the National Industrial Standard of SNI 16-4221. The beeswax cartridge arrangement was varied to obtain the best performance. The results showed that polyurethane provides infant incubator lighter and more practical to use. The new design of non-electric infant incubator was capable of providing a temperature of 32-36 °C for 2 h.
- Open Access
- 31 July 2017
- Published by International Journal of Technology in International Journal of Technology
- Vol. 8 (4) , 690
Vapor Chamber Utilization for Rapid Cooling in the Conventional Plastic Injection Molding Process
- 31 July 2017
- Published by International Journal of Technology in International Journal of Technology
- Vol. 8 (4) , 690
Open AccessVapor Chamber Utilization for Rapid Cooling in the Conventional Plastic Injection Molding Process
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1817, 020017
Experimental investigation on phase change materials as heating element for non-electric neonatal incubator
High number of preterm births is one of the issues in improving health standard. The effort to help premature babies is hampered by high cost of NICU care in hospital. In addition, uneven distribution of electricity to remote area made it hard to operate the incubator. Utilization of phase change material beeswax to non-electricity incubator as heating element becomes alternative option to save premature babies. The objective of this experiment is to investigate the most efficient mass of beeswax according to Indonesian National Standard to earn over time and ideal temperature of incubator. Experiment was performed using prototype incubator, which utilizes natural convection phenomenon in the heating process of incubator. Utilization of fin is to accelerate heat distribution in the incubator. Result of experiment showed that the most efficient mass of PCM is 3 kg, which has 2.45 hours of running time for maintaining temperature of incubator in range of 32-36 °C.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1817, 020017
Experimental investigation on phase change materials as heating element for non-electric neonatal incubator
High number of preterm births is one of the issues in improving health standard. The effort to help premature babies is hampered by high cost of NICU care in hospital. In addition, uneven distribution of electricity to remote area made it hard to operate the incubator. Utilization of phase change material beeswax to non-electricity incubator as heating element becomes alternative option to save premature babies. The objective of this experiment is to investigate the most efficient mass of beeswax according to Indonesian National Standard to earn over time and ideal temperature of incubator. Experiment was performed using prototype incubator, which utilizes natural convection phenomenon in the heating process of incubator. Utilization of fin is to accelerate heat distribution in the incubator. Result of experiment showed that the most efficient mass of PCM is 3 kg, which has 2.45 hours of running time for maintaining temperature of incubator in range of 32-36 °C.