Mairaj Ali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mairaj Ali has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Asfand Ateem
Department of Electrical Engineering, National University of Computer & Emerging Sciences FAST, Islamabad, Pakistan
2 shared publicationsMuwahida Liaquat
Department of Electrical Engineering, College of E ME, National University of Sciences Technology, Islamabad, Pakistan
2 shared publicationsZeeshan Ali Akbar
Department of Electrical Engineering, College of E&ME, National University of Sciences and Technology, Islamabad, Pakistan
2 shared publicationsArslan Safdar
Department of Electrical Engineering, College of E ME, National University of Sciences Technology, Islamabad, Pakistan
1 shared publicationMuhammad Asad Bashir
Department of Electrical Engineering, College of E&ME, National University of Sciences and Technology, Islamabad, Pakistan
1 shared publication- Muhammad Bashir
School of Electronics and Information, Xi’an Polytechnic University, Xi’an, China
1 shared publication
Latest Publications
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 445-451
Leader-Following Sample data Formation Control ofNonholonomic Robots with Switching Network Topologies
In this paper the problem of sample data cooperative output regulation for the leader-following formation (LFF) problem of a homogenous multi agent system is investigated. For sample data LFF problem a distributed design approach is proposed using luenberger observer, distributed observer and a zeroorder hold circuit. The designed approach enables the robots to track a discrete reference signal generated by the leader and to achieve and maintain the desired formation for the provided initial conditions. A driving force is provided by the exogenous system which serve as a leader for the robot formation. In view of time varying interaction between robots, one case of fixed network topology and two cases of switching network topologies are considered to exhibit the multirobot network relationship. The theoretical results are verified through numerical simulations of four nonholonomic multirobot network. The simulation highlights that the robots are maintaining the desired formation and are also tracking the trajectory of the leader robot under fixed and switching topologies of the multinetwork system.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 445-451
Leader-Following Sample data Formation Control ofNonholonomic Robots with Switching Network Topologies
In this paper the problem of sample data cooperative output regulation for the leader-following formation (LFF) problem of a homogenous multi agent system is investigated. For sample data LFF problem a distributed design approach is proposed using luenberger observer, distributed observer and a zeroorder hold circuit. The designed approach enables the robots to track a discrete reference signal generated by the leader and to achieve and maintain the desired formation for the provided initial conditions. A driving force is provided by the exogenous system which serve as a leader for the robot formation. In view of time varying interaction between robots, one case of fixed network topology and two cases of switching network topologies are considered to exhibit the multirobot network relationship. The theoretical results are verified through numerical simulations of four nonholonomic multirobot network. The simulation highlights that the robots are maintaining the desired formation and are also tracking the trajectory of the leader robot under fixed and switching topologies of the multinetwork system.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 12-15
Comparison Between Distributed Observer And Adaptive Distributed Observer
This paper presents a comparison between distributed and adaptive distributed observer-based methods for the cooperative output regulation problem of linear multi agent systems. For the system involving the distributed observer, it is assumed that all the followers have access to system matrix from the leader system. The adaptive distributed observer method however assumes that the followers have no information about the leader signal and leader matrix the followers will estimate the leader matrix and signal adaptively. The analysis is carried out by applying both techniques on linear model of servo motors.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 12-15
Comparison Between Distributed Observer And Adaptive Distributed Observer
This paper presents a comparison between distributed and adaptive distributed observer-based methods for the cooperative output regulation problem of linear multi agent systems. For the system involving the distributed observer, it is assumed that all the followers have access to system matrix from the leader system. The adaptive distributed observer method however assumes that the followers have no information about the leader signal and leader matrix the followers will estimate the leader matrix and signal adaptively. The analysis is carried out by applying both techniques on linear model of servo motors.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Detecting and monitoring of voltage and frequency variation and under ground cable fault location using check point method
Voltage variations, frequency variations and phase variations are the reason for the failure of Power grid synchronization so in this paper we are monitoring the voltage, phase and frequency variations. For voltage variations we use windows comparator method in which there is a comparison between upper voltage and lower voltage i.e. when the voltage exceeds the normal voltage a real time monitoring application will automatically detect higher voltage and same for the lower voltage that is when voltage in the main line drops below normal voltage the application will show lower voltage. Similarly for frequency monitoring we use zero-cross detector method. Furthermore we have also detected the faults in main line through checkpoint method. In each check point we have step down transformer connected with the bridge rectifier, further following a regulator for constant voltage, capacitor for filtering and a relay which will send on and off pulses to the visual basic showing the load condition either on or off in the specified area.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Detecting and monitoring of voltage and frequency variation and under ground cable fault location using check point method
Voltage variations, frequency variations and phase variations are the reason for the failure of Power grid synchronization so in this paper we are monitoring the voltage, phase and frequency variations. For voltage variations we use windows comparator method in which there is a comparison between upper voltage and lower voltage i.e. when the voltage exceeds the normal voltage a real time monitoring application will automatically detect higher voltage and same for the lower voltage that is when voltage in the main line drops below normal voltage the application will show lower voltage. Similarly for frequency monitoring we use zero-cross detector method. Furthermore we have also detected the faults in main line through checkpoint method. In each check point we have step down transformer connected with the bridge rectifier, further following a regulator for constant voltage, capacitor for filtering and a relay which will send on and off pulses to the visual basic showing the load condition either on or off in the specified area.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Eye monitored device for disable people
Technology is all about serving mankind. People are getting needy for technology as the time is clicking. Technologists love to break obstacles; it is what they are doing for ease of homo sapiens. In addition to it we have also lodge a model to engineer modish thing with technology. Statistics suggests that there are many cases of paralyzed people noticed every year including people suffering from locked in syndrome; is a medical mode in which most of the body muscles are paralyzed except the movement of eyes. Our project strive to mould the life of such people effortless, painless and manageable to re-establish the happiness, satisfaction, cheerfulness and self-possession of such people. Our paper put forward the execution of inexpensive support for disable people and to manufacture eye monitored device which controls the switching of any electrical devices / loads based on the movement of eyes. The paper demonstrates that communication is originated from the movement of eyes towards left, right, upper, lower and blinking of eyes monitored by MATLAB script which will then advice the relay wired with microcontroller to switch on / off and control the electrical loads through serial communication.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Eye monitored device for disable people
Technology is all about serving mankind. People are getting needy for technology as the time is clicking. Technologists love to break obstacles; it is what they are doing for ease of homo sapiens. In addition to it we have also lodge a model to engineer modish thing with technology. Statistics suggests that there are many cases of paralyzed people noticed every year including people suffering from locked in syndrome; is a medical mode in which most of the body muscles are paralyzed except the movement of eyes. Our project strive to mould the life of such people effortless, painless and manageable to re-establish the happiness, satisfaction, cheerfulness and self-possession of such people. Our paper put forward the execution of inexpensive support for disable people and to manufacture eye monitored device which controls the switching of any electrical devices / loads based on the movement of eyes. The paper demonstrates that communication is originated from the movement of eyes towards left, right, upper, lower and blinking of eyes monitored by MATLAB script which will then advice the relay wired with microcontroller to switch on / off and control the electrical loads through serial communication.