Vladimir R. Sorochenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vladimir R. Sorochenko has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Victor V. Apollonov
General Physics Institute (Russia)
6 shared publicationsN. V. Pletnyev
General Physics Institute (Russia)
5 shared publicationsA. A. Kuchinsky
D.V. Efremov Scientific Research Institute of Electrophysical Apparatus (Russia)
3 shared publicationsGennady A. Baranov
D.V. Efremov Scientific Research Institute of Electrophysical Apparatus (Russia)
3 shared publicationsK. K. Kazakov
General Physics Institute (Russia)
3 shared publicationsV. P. Tomashevich
D.V. Efremov Scientific Research Institute of Electrophysical Apparatus (Russia)
3 shared publications
Latest Publications
- 26 November 2018
- Published by IOP Publishing in Quantum Electronics
- Vol. 48 (11) , 1000-1004
Antireflection coating of diamond elements of power optics for CO2 lasers
- 26 November 2018
- Published by IOP Publishing in Quantum Electronics
- Vol. 48 (11) , 1000-1004
Antireflection coating of diamond elements of power optics for CO2 lasers
- 1 May 2018
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 61 (3) , 386-392
Single-Frequency TEA CO2 Laser for Experiments on Non-Resonant Radiation Interaction with Matter
The design philosophy and output radiation parameters of single frequency TEA CO2 laser with bleaching intracavity longitudinal modes selector (cell filled with SF6) are described. At cavity tuning...
- 1 May 2018
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 61 (3) , 386-392
Single-Frequency TEA CO2 Laser for Experiments on Non-Resonant Radiation Interaction with Matter
The design philosophy and output radiation parameters of single frequency TEA CO2 laser with bleaching intracavity longitudinal modes selector (cell filled with SF6) are described. At cavity tuning...
- 30 January 2017
- Published by IOP Publishing in Quantum Electronics
- Vol. 47 (1) , 20-25
Single-frequency TEA CO2 laser with a bleaching spectral intracavity filter
- 30 January 2017
- Published by IOP Publishing in Quantum Electronics
- Vol. 47 (1) , 20-25
Single-frequency TEA CO2 laser with a bleaching spectral intracavity filter
- 31 October 2012
- Published by IOP Publishing in Quantum Electronics
- Vol. 42 (10) , 907-912
Nonlinear transmission of CO2laser radiation by graphene
- 31 October 2012
- Published by IOP Publishing in Quantum Electronics
- Vol. 42 (10) , 907-912
Nonlinear transmission of CO2laser radiation by graphene
- 4 December 2010
- Published by Allerton Press in Physics of Wave Phenomena
- Vol. 18 (4) , 240-244
Parametric oscillation of high-power 3-THz pulse by synchronously pumped ZnGeP2 crystal: Computer simulation
- 4 December 2010
- Published by Allerton Press in Physics of Wave Phenomena
- Vol. 18 (4) , 240-244
Parametric oscillation of high-power 3-THz pulse by synchronously pumped ZnGeP2 crystal: Computer simulation
- 20 November 2009
- Published by Allerton Press in Physics of Wave Phenomena
- Vol. 17 (4) , 233-240
Simulation of parametric oscillation in the submillimeter range at pumping of the ZnGeP2 crystal by a train of 100-ps high-power pulses
Analysis is given for a possibility of singly resonant parametric oscillation in the submillimeter range at synchronous pumping of the ZnGeP2 crystal by a train of 100-ps second-harmonic pulses from the CO2 laser with the radiation energy 1.0 J. The calculation shows that using the ZnGeP2 crystal and the second harmonic of the CO2 laser with the energy density 1.8 J cm−2, one can get the peak submillimeter radiation power from 3.6 to 12 MW in the range from 95 to 300 µm (1.0–3.3 THz). The expected peak power values are larger than the experimental ones obtained by other nonlinear optics methods.
- 20 November 2009
- Published by Allerton Press in Physics of Wave Phenomena
- Vol. 17 (4) , 233-240
Simulation of parametric oscillation in the submillimeter range at pumping of the ZnGeP2 crystal by a train of 100-ps high-power pulses
Analysis is given for a possibility of singly resonant parametric oscillation in the submillimeter range at synchronous pumping of the ZnGeP2 crystal by a train of 100-ps second-harmonic pulses from the CO2 laser with the radiation energy 1.0 J. The calculation shows that using the ZnGeP2 crystal and the second harmonic of the CO2 laser with the energy density 1.8 J cm−2, one can get the peak submillimeter radiation power from 3.6 to 12 MW in the range from 95 to 300 µm (1.0–3.3 THz). The expected peak power values are larger than the experimental ones obtained by other nonlinear optics methods.
- 1 May 2009
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 52 (3) , 412-420
Registration of picosecond CO2 laser pulses by means of two-stage parametric transformation in nonlinear crystals
A technique for registering the temporal structure of picosecond pulses of CO2 laser radiation with an energy of 1.5–4.5 μJ at a wavelength of 10.27 μm using two-stage parametric transformation of IR radiation frequency into visible light under pumping of nonlinear crystals by Nd:YAG-laser radiation in a Q-switched mode is described. A GaSe nonlinear crystal was used at the first stage of transformation (10.27 μm + 1.064 μm → 0.964 μm). Radiation was further transformed (1.064 μm + 0.960 μm → 0.506 μm) by using the same pumping in an α-HIO3 nonlinear crystal. For the first time, no additional optical elements were present between the stages of the frequency transformer in the proposed optical scheme. The transformed radiation was registered with a Hamamatsu Temporal Disperser C1587 streak camera in a region of the photocathode maximum spectral sensitivity of ∼0.5 μm with a temporal resolution of up to 2 ps. The minimum recorded pulse duration of the CO2 laser was ∼45 ps.
- 1 May 2009
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 52 (3) , 412-420
Registration of picosecond CO2 laser pulses by means of two-stage parametric transformation in nonlinear crystals
A technique for registering the temporal structure of picosecond pulses of CO2 laser radiation with an energy of 1.5–4.5 μJ at a wavelength of 10.27 μm using two-stage parametric transformation of IR radiation frequency into visible light under pumping of nonlinear crystals by Nd:YAG-laser radiation in a Q-switched mode is described. A GaSe nonlinear crystal was used at the first stage of transformation (10.27 μm + 1.064 μm → 0.964 μm). Radiation was further transformed (1.064 μm + 0.960 μm → 0.506 μm) by using the same pumping in an α-HIO3 nonlinear crystal. For the first time, no additional optical elements were present between the stages of the frequency transformer in the proposed optical scheme. The transformed radiation was registered with a Hamamatsu Temporal Disperser C1587 streak camera in a region of the photocathode maximum spectral sensitivity of ∼0.5 μm with a temporal resolution of up to 2 ps. The minimum recorded pulse duration of the CO2 laser was ∼45 ps.
- 30 April 2007
- Published by IOP Publishing in Quantum Electronics
- Vol. 37 (4) , 383-384
Single-mode crystalline optical fibres for a wavelength of 10.6 μm
- 30 April 2007
- Published by IOP Publishing in Quantum Electronics
- Vol. 37 (4) , 383-384
Single-mode crystalline optical fibres for a wavelength of 10.6 μm
- 7 November 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5120, 291-297
Picosecond terawatt CO2 laser system Picasso-2
Current status of CO2 laser system “Picasso-2” intended to generate 10 μm pulse train with tunable pulses duration 2÷100 ps, interpulse separation ≈ 10 ns and train’s peak power over 1 TW is reported.
- 7 November 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5120, 291-297
Picosecond terawatt CO2 laser system Picasso-2
Current status of CO2 laser system “Picasso-2” intended to generate 10 μm pulse train with tunable pulses duration 2÷100 ps, interpulse separation ≈ 10 ns and train’s peak power over 1 TW is reported.
- 25 January 2001
- Published by SPIE-Intl Soc Optical Eng
- p. 317-322
Superatmospheric x-ray preionized TE-CO 2 discharge unit
- 25 January 2001
- Published by SPIE-Intl Soc Optical Eng
- p. 317-322
Superatmospheric x-ray preionized TE-CO 2 discharge unit