Kabilan Sakthivel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kabilan Sakthivel has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Keekyoung Kim
University of Calgary
4 shared publications - Hitendra Kumar
Department of Biosciences and Biomedical Engineering, Indian Institute of Technology Indore, Indore, Madhya Pradesh, 453552, India
2 shared publications - Mohamed G. A. Mohamed
School of Engineering, University of British Columbia, Kelowna, BC, V1V 1V7, Canada
2 shared publications Allen O'BRien
1 shared publicationAyyapillai Tamizhanban
Department of Chemistry, School of Chemical and Biotechnology, SASTRA Deemed University, Thanjavur – 613401, India
1 shared publicationBahram Talebjedi
School of Engineering, University of British Columbia, Kelowna, BC, V1V 1V7, Canada
1 shared publication
Latest Publications
- 11 October 2020
- Published by Wiley in Macromolecular Bioscience
- Vol. 21 (1) , e2000317
Designing Gelatin Methacryloyl (GelMA)‐Based Bioinks for Visible Light Stereolithographic 3D Biofabrication
Bioinks play a key role in determining the capability of the biofabricatoin processes and the resolution of the printed constructs. Excellent biocompatibility, tunable physical properties, and ease of chemical or biological modifications of gelatin methacryloyl (GelMA) have made it an attractive choice as bioinks for biomanufacturing of various tissues or organs. However, the current preparation methods for GelMA‐based bioinks lack the ability to tailor their physical properties for desired bioprinting methods. Inherently, GelMA prepolymer solution exhibits a fast sol–gel transition at room temperature, which is a hurdle for its use in stereolithography (SLA) bioprinting. Here, synthesis parameters are optimized such as solvents, pH, and reaction time to develop GelMA bioinks which have a slow sol–gel transition at room temperature and visible light crosslinkable functions. A total of eight GelMA combinations are identified as suitable for digital light processing (DLP)‐based SLA (DLP‐SLA) bioprinting through systematic characterizations of their physical and rheological properties. Out of various types of GelMA, those synthesized in reverse osmosis (RO) purified water (referred to as RO‐GelMA) are regarded as most suitable to achieve high DLP‐SLA printing resolution. RO‐GelMA‐based bioinks are also found to be biocompatible showing high survival rates of encapsulated cells in the photocrosslinked gels. Additionally, the astrocytes and fibroblasts are observed to grow and integrate well within the bioprinted constructs. The bioink's superior physical and photocrosslinking properties offer pathways of tuning the scaffold microenvironment and highlight the applicability of developed GelMA bioinks in various tissue engineering and regenerative medicine applications.
- 11 October 2020
- Published by Wiley in Macromolecular Bioscience
- Vol. 21 (1) , e2000317
Designing Gelatin Methacryloyl (GelMA)‐Based Bioinks for Visible Light Stereolithographic 3D Biofabrication
Bioinks play a key role in determining the capability of the biofabricatoin processes and the resolution of the printed constructs. Excellent biocompatibility, tunable physical properties, and ease of chemical or biological modifications of gelatin methacryloyl (GelMA) have made it an attractive choice as bioinks for biomanufacturing of various tissues or organs. However, the current preparation methods for GelMA‐based bioinks lack the ability to tailor their physical properties for desired bioprinting methods. Inherently, GelMA prepolymer solution exhibits a fast sol–gel transition at room temperature, which is a hurdle for its use in stereolithography (SLA) bioprinting. Here, synthesis parameters are optimized such as solvents, pH, and reaction time to develop GelMA bioinks which have a slow sol–gel transition at room temperature and visible light crosslinkable functions. A total of eight GelMA combinations are identified as suitable for digital light processing (DLP)‐based SLA (DLP‐SLA) bioprinting through systematic characterizations of their physical and rheological properties. Out of various types of GelMA, those synthesized in reverse osmosis (RO) purified water (referred to as RO‐GelMA) are regarded as most suitable to achieve high DLP‐SLA printing resolution. RO‐GelMA‐based bioinks are also found to be biocompatible showing high survival rates of encapsulated cells in the photocrosslinked gels. Additionally, the astrocytes and fibroblasts are observed to grow and integrate well within the bioprinted constructs. The bioink's superior physical and photocrosslinking properties offer pathways of tuning the scaffold microenvironment and highlight the applicability of developed GelMA bioinks in various tissue engineering and regenerative medicine applications.
High Throughput Screening of Cell Mechanical Response Using a Stretchable 3D Cellular Microarray Platform
Cells in vivo are constantly subjected to multiple microenvironmental mechanical stimuli that regulate cell function. Although 2D cell responses to the mechanical stimulation have been established, these methods lack relevance as physiological cell microenvironments are in 3D. Moreover, the existing platforms developed for studying the cell responses to mechanical cues in 3D either offer low‐throughput, involve complex fabrication, or do not allow combinatorial analysis of multiple cues. Considering this, a stretchable high‐throughput (HT) 3D cell microarray platform is presented that can apply dynamic mechanical strain to cells encapsulated in arrayed 3D microgels. The platform uses inkjet‐bioprinting technique for printing cell‐laden gelatin methacrylate (GelMA) microgel array on an elastic composite substrate that is periodically stretched. The developed platform is highly biocompatible and transfers the applied strain from the stretched substrate to the cells. The HT analysis is conducted to analyze cell mechano‐responses throughout the printed microgel array. Also, the combinatorial analysis of distinct cell behaviors is conducted for different GelMA microenvironmental stiffnesses in addition to the dynamic stretch. Considering its throughput and flexibility, the developed platform can readily be scaled up to introduce a wide range of microenvironmental cues and to screen the cell responses in a HT way.
High Throughput Screening of Cell Mechanical Response Using a Stretchable 3D Cellular Microarray Platform
Cells in vivo are constantly subjected to multiple microenvironmental mechanical stimuli that regulate cell function. Although 2D cell responses to the mechanical stimulation have been established, these methods lack relevance as physiological cell microenvironments are in 3D. Moreover, the existing platforms developed for studying the cell responses to mechanical cues in 3D either offer low‐throughput, involve complex fabrication, or do not allow combinatorial analysis of multiple cues. Considering this, a stretchable high‐throughput (HT) 3D cell microarray platform is presented that can apply dynamic mechanical strain to cells encapsulated in arrayed 3D microgels. The platform uses inkjet‐bioprinting technique for printing cell‐laden gelatin methacrylate (GelMA) microgel array on an elastic composite substrate that is periodically stretched. The developed platform is highly biocompatible and transfers the applied strain from the stretched substrate to the cells. The HT analysis is conducted to analyze cell mechano‐responses throughout the printed microgel array. Also, the combinatorial analysis of distinct cell behaviors is conducted for different GelMA microenvironmental stiffnesses in addition to the dynamic stretch. Considering its throughput and flexibility, the developed platform can readily be scaled up to introduce a wide range of microenvironmental cues and to screen the cell responses in a HT way.
- 1 August 2019
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 117, 166-185
Microfluidic analysis of heterotypic cellular interactions: A review of techniques and applications
- 1 August 2019
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 117, 166-185
Microfluidic analysis of heterotypic cellular interactions: A review of techniques and applications
- Open Access
- 5 November 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (65) , 37136-37145
Enzymatic synthesis and self-assembly of glycolipids: robust self-healing and wound closure performance of assembled soft materials
In developing countries, wounds are a major health concern and pose a significant problem. Hence, the development of new materials that can act as scaffolds for in situ tissue regeneration and regrowth is necessary. In this report, we present a new class of injectable oleogel and composite gel derived from glycolipids that provide reversible interlinked 3D fiberous network architecture for effective wound closure by tissue regrowth and regeneration. Glycolipids were derived from α-chloralose and various vinyl esters using Novozyme 435, an immobilized lipase B from Candida antarctica as a catalyst, in good yield. These glycolipids undergo spontaneous self-assembly in paraffin oil to form an oleogel, in which curcumin was successfully incorporated to generate a composite gel. Morphological analysis of the oleogel and composite gel clearly revealed the formation of a 3D fiberous network. Rheological investigation revealed the thermal and mechanical processability of the oleogel and composite gel under various experimental conditions. Interestingly, the developed injectable oleogel and composite gel are able to accelerate the wound healing process by regulating the overlapping phases of inflammation, cell proliferation and extracellular matrix remodelling. Since chloralose displays anesthetic properties, this study will establish a new strategy to develop anesthetic wound healing oleogels in the future.
- 5 November 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (65) , 37136-37145
Open AccessEnzymatic synthesis and self-assembly of glycolipids: robust self-healing and wound closure performance of assembled soft materials
In developing countries, wounds are a major health concern and pose a significant problem. Hence, the development of new materials that can act as scaffolds for in situ tissue regeneration and regrowth is necessary. In this report, we present a new class of injectable oleogel and composite gel derived from glycolipids that provide reversible interlinked 3D fiberous network architecture for effective wound closure by tissue regrowth and regeneration. Glycolipids were derived from α-chloralose and various vinyl esters using Novozyme 435, an immobilized lipase B from Candida antarctica as a catalyst, in good yield. These glycolipids undergo spontaneous self-assembly in paraffin oil to form an oleogel, in which curcumin was successfully incorporated to generate a composite gel. Morphological analysis of the oleogel and composite gel clearly revealed the formation of a 3D fiberous network. Rheological investigation revealed the thermal and mechanical processability of the oleogel and composite gel under various experimental conditions. Interestingly, the developed injectable oleogel and composite gel are able to accelerate the wound healing process by regulating the overlapping phases of inflammation, cell proliferation and extracellular matrix remodelling. Since chloralose displays anesthetic properties, this study will establish a new strategy to develop anesthetic wound healing oleogels in the future.
- 1 September 2016
- Published by AIP Publishing in Biomicrofluidics
- Vol. 10 (5) , 054110
An automated system for high-throughput generation and optimization of microdroplets
Microdroplets have been widely used in various biomedical applications. During droplet generation, parameters are manually adjusted to achieve the desired size of droplets. This process is tedious and time-consuming. In this paper, we present a fully automated system for controlling the size of droplets to optimize droplet generation parameters in a microfluidic flow-focusing device. The developed system employed a novel image processing program to measure the diameter of droplets from recorded video clips and correspondingly adjust the flow rates of syringe pumps to obtain the required diameter of droplets. The system was tested to generate phosphate-buffered saline and 8% polyethylene (glycol) diacrylate prepolymer droplets and regulate its diameters at various flow rates. Experimental results demonstrated that the difference between droplet diameters from the image processing and manual measurement is not statistically significant and the results are consistent over five repetitions. Taking the advantages of the accurate image processing method, the size of the droplets can be optimized in a precise and robust manner via automatically adjusting flow rates by the feedback control. The system was used to acquire quantitative data to examine the effects of viscosity and flow rates. Droplet-based experiments can be greatly facilitated by the automatic droplet generation and optimization system. Moreover, the system is able to provide quantitative data for the modelling and application of droplets with various conditions in a high-throughput way.
- 1 September 2016
- Published by AIP Publishing in Biomicrofluidics
- Vol. 10 (5) , 054110
An automated system for high-throughput generation and optimization of microdroplets
Microdroplets have been widely used in various biomedical applications. During droplet generation, parameters are manually adjusted to achieve the desired size of droplets. This process is tedious and time-consuming. In this paper, we present a fully automated system for controlling the size of droplets to optimize droplet generation parameters in a microfluidic flow-focusing device. The developed system employed a novel image processing program to measure the diameter of droplets from recorded video clips and correspondingly adjust the flow rates of syringe pumps to obtain the required diameter of droplets. The system was tested to generate phosphate-buffered saline and 8% polyethylene (glycol) diacrylate prepolymer droplets and regulate its diameters at various flow rates. Experimental results demonstrated that the difference between droplet diameters from the image processing and manual measurement is not statistically significant and the results are consistent over five repetitions. Taking the advantages of the accurate image processing method, the size of the droplets can be optimized in a precise and robust manner via automatically adjusting flow rates by the feedback control. The system was used to acquire quantitative data to examine the effects of viscosity and flow rates. Droplet-based experiments can be greatly facilitated by the automatic droplet generation and optimization system. Moreover, the system is able to provide quantitative data for the modelling and application of droplets with various conditions in a high-throughput way.