SMSamir Morad

Samir Morad

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Samir Morad has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The development of a 3d-printed exoskeleton knee brace for independent resistance training

    by Samir Morad, Harvey Kloey Pangilinan

    This study focuses on the restricted accessibility for people who are unable to undertake lower limb resistance exercise independently. Many typical exercises rely on external equipment or assistance, which limits the options for many rehabilitation patients, such as those who have had a stroke, neuromuscular conditions, or surgery recovery. This study aimed to develop a low-cost, innovative 3D-printed exoskeleton knee brace (KB) for independent resistance training, targeting the knee extensors and flexors. The KB prototype was designed to provide comfort, safety, and a mix of lightweight and strength. Kinematic analysis was used to evaluate the forces generated by resistance bands, and the design underwent finite element analysis simulation to ensure its structural integrity. Results indicate high user satisfaction, specifically regarding the KB’s lightweight design and perceived safety. Participants perceived that the brace provided appropriate resistance for targeting the quadriceps and hamstring muscle groups during knee extension and flexion exercises. Participants recommended design improvements, including adjustments to the strap and length. The study suggests that KBs are a suitable method for independent resistance training, and future research should focus on evaluating their effectiveness in rehabilitation patients who are unable to perform current lower limb activities.

  • The integration of an articulated probe and a waterjet cutting tool for spinal surgical robots

    by Samir Morad, Christian Ulbricht, Paul Harkin, Justin Chan, Kim Parker, Ravi Vaidyanathan

    Spinal surgery procedure is often necessary to remove cancerous tissue within or surrounding the spinal cord and spinal column. This procedure, however, is restricted by the incapability of rigid hand-held drills and cutting tools to reach the target tissue in complex anatomical pathways. Previously, we introduced the surgical robotic platform with a novel concentric connector joint and developed a haptic control system that integrates an active constraint controller into a surgical robot platform. This study introduces the design and experimental testing of a new articulated surgical tool that can navigate around the spinal column using a water jet cutting system for safer removal of tumorous tissue. This innovative approach allows the removal of cancerous tissue on both the anterior and posterior sides of the spinal column without high-speed rotating equipment. A water jet cutting system integrated with an articulated distal tip (ADT) has been developed and successfully tested. A mock surgical procedure on the lower lumbar vertebrae has been used to test the accuracy and performance of the prototype. Results show promise for combining waterjet cutting and an ADT for surgical spinal procedures. The articulated surgical water jet tool removed 82% of mock cancerous tissue compared to 16% of tissue removed by the rigid tool.

  • Open Access

    A Wearable Pad for Detecting and Monitoring Heel Pressure Ulcer: Preliminary Study

    by S. Morad, A. M. Biju, A. H. Morad

    Discover cutting-edge insights with IJET—your premier source for peer-reviewed engineering and technology research, fostering global innovation.

  • Open Access

    Active constraint control for the surgical robotic platform with concentric connector joints

    by Samir Morad, Christian Ulbricht, Paul Harkin, Justin Chan, Kim Parker, Ravi Vaidyanathan

    Robotic minimally invasive surgery (MIS) has changed numerous surgical techniques in the past few years and enhanced their results. Haptic feedback is integrated into robotic surgical systems to restore the surgeon's perception of forces in response to interaction with objects in the surgical environment. The ideal exact emulation of the robot's interaction with its physical environment in free space is a very challenging problem to solve completely. Previously, we introduced the surgical robotic platform (SRP) with a novel concentric connector joint (CCJ). This study aims to develop a haptic control system that integrates an active constraint controller into a surgical robot platform. We have successfully established haptic feedback control for the surgical robot using constraint control and inverse kinematic relationships integrated into the overall positioning structure. A preliminary feasibility study, modelling, and simulation were presented.


  • Custom Fit Non-Invasive Ventilation Mask with Microclimate Monitor: Preliminary Study

    by S. Morad, S. Lindsay

    Discover cutting-edge insights with IJET—your premier source for peer-reviewed engineering and technology research, fostering global innovation.

  • Open Access

    Non-Invasive Ventilation Sensor Mask (NIVSM): Preliminary Design and Testing

    by Hanan Lebetiou, Paul Nichols, Samir Morad, Mhd Saeed Sharif

    Previous research has emphasized the significance of mask and interface design in non-invasive ventilation (NIV) and the prevention of pressure ulcers (PUs). Multiple variables are involved in the necrosis process, but the skin-mask interface has a significant impact. A preliminary design of a custom-fit Mask (CFM) embedded with a microclimate sensor has been introduced previously. This study aims to improve the comfort and safety of patients who use NIV masks for long periods. The personalized cushion fit (PCF) is designed using 3D scanning and printing technology and integrated into a pre-existing mask. Integration with a preexisting mask has been achieved by fabricating a modular design that acts as a disposable PCF. Embedded sensors are added to the mask to measure the skin-mask microclimate. Real-time data is plotted and monitored for critical conditions and to identify other key features. A preliminary temperature-humidity (T-H) monitoring of the skin-mask interface for both PCF and pre-existing mask shows fluctuation trends that could potentially induce PUs. However, there is a more sensitive reaction in the PCF test. The NIVSM can be combined with a ventilation device and utilized to establish ideal levels of humidity and temperature on the skin to prevent the formation of PUs

  • A Novel Mechanical Design of a Wearable Fingertip Haptic Device for Remote Meniscus Palpation

    by Samir Morad, Zainab Jaffer, Sanja Dogramadzi

    A pneumatic model of a fingertip haptic device (FHD) had been previously tested in virtual reality allowing the perception of different materials with a promising result. However, numerous drawbacks were noted in this design, including bulky size, less portability, and discomfort. In this paper, FHD is redesigned to provide haptic feedback for human meniscus palpation. A user study was performed to evaluate the effectiveness of the redesigned FHD. The study showed that the redesigned model could successfully provide a more evident perception of different stiffness levels but it compromised the comfort of the user when mounted on the finger for long periods.


  • Design of a Wearable Fingertip Haptic Device: Investigating Materials of Varying Stiffness for Mapping the Variable Compliance Platform

    by Samir Morad, Zainab Jaffer, Sanja Dogramadzi

    Previously, a pneumatic design of a fingertip haptic device (FHD) was developed for virtual reality applications. In this paper, the feasibility of representing tissues of varying stiffness is investigated. Physical properties, stiffness and Young’s modulus of the variable compliance platform (VCP) were compared with a set of bolus materials representing soft tissues. Young’s moduli of the bolus materials were ten times higher than those from the VCP, whereas the stiffness was fairly similar. Hence, stiffness is the common parameter that could be used to map the FHD to the bolus materials.


  • Surgical Robot Platform with a Novel Concentric Joint for Minimally Invasive Procedures

    by Samir Morad, Christian Ulbricht, Paul Harkin, Justin Chan, Kim Parker, Ravi Vaidyanathan

    In this paper, a surgical robot platform with a novel concentric connector joint (CCJ) is presented. The surgical robot is a parallel robot platform comprised of multiple struts, arranged in a geometrically stable array, connected at their end points via the CCJ. The CCJ joints have near-perfect concentricity of rotation around the node point, which enables the tension and compression forces of the struts to be resolved in a structurally-efficient manner. The preliminary feasibility tests, modeling and simulations were introduced.


  • Open Access

    Concentric joint connectors for form-changing space frames

    by P. Harkin, R. Vaidyanathan, S. Morad

    This paper presents a novel joint design for use in form-changing structural frames. These structures are comprised of multiple struts, arranged in a geometrically stable array, connected at their end points via the joints. Each strut, acting as part of a truss, can change in length (telescope), and thus their combined variations can change the overall form of the frame. The joints enable multiple struts to be connected together and pivot around each node point. The joints have near-perfect concentricity of rotation around the node point, which enables the tension and compression forces of the struts to be resolved in a structurally-efficient manner. The design evolved from an analysis of simple, pure-tension net structures, combined with aspects of rigid space frame structures, to resist compressive forces. Existing joint configurations are analyzed and compared to the novel joint. Several applications of form-changing structural frames are noted, to demonstrate the advantages of using such joint connectors in these frames; one is a variable-geometry mount for a surgical device, for Imperial College London.