ACAndres Coila

Andres Coila

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andres Coila has a total of 29 co-authors. Here are the top co-authors by number of shared publications:

  • Roberto Lavarello

    Laboratorio de Imágenes Médicas, Pontificia Universidad Católica del Perú, Lima, Peru

    10 shared publications
  • Michael L. Oelze

    Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Champaign, IL 61801, USA

    6 shared publications
  • Julien Rouyer

    Laboratorio de Imágenes Médicas, Departamento de Ingeniería, Pontificia Universidad Católica del Perú, San Miguel, Lima 32, Perú

    3 shared publications
  • Adriana Romero

    Pontificia Universidad Católica del Perú, San Miguel, Lima, Peru

    2 shared publications
  • Julien Rouyer

    Laboratorio de Imágenes Médicas, Departmento de Ingeniería, Pontificia Universidad Católica del Perú, San Miguel, Lima, Peru

    2 shared publications
  • Michael L. Oelze

    Beckman Institute for Advanced Science and Technology, Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA

    2 shared publications

Latest Publications

  • Open Access

    Closed-form weak-wave propagation pressure amplitudes for arbitrary power-law attenuation

    by Esteban Avilés, Michael Oelze, Roberto Lavarello, Andres Coila

    Biological tissues exhibit power-law frequency dependence of the attenuation coefficient. We derive closed-form weak-wave expressions for fundamental, second-, and third-harmonic pressure amplitudes of monochromatic acoustic plane waves in homogeneous media with arbitrary power-law attenuation to extend classical expressions for quadratic attenuation. For linear frequency dependence of attenuation, one-dimensional simulations using the k-Wave k-space pseudospectral solver yielded 35%–42% (classical) and 0%–2% (proposed) normalized root mean square errors for fundamental-band depletion. This extension supports improved fundamental-band B/A estimation for quantitative ultrasound tissue characterization. A proof-of-concept through-transmission application in phantoms with nearly linear attenuation yielded experimental B/A estimation errors of 23.7%–52.7% (classical) and 4.0%–5.9% (proposed).

  • Regularized Joint Estimator of the Nonlinearity Parameter and Attenuation Coefficient Using a Nonlinear Least-Squares Algorithm

    by Sebastian Merino, Adriana Romero, Roberto Lavarello, Andres Coila

    The acoustic nonlinearity parameter (B/A) could enhance the diagnostic capabilities of conventional ultrasonography and quantitative ultrasound in tissues and diseases. Nonlinear acoustic propagation theory of plane waves has been used to develop a dual-energy model of the depletion of the fundamental related to the Gol’dberg number and subsequently to the B/A of media (a reference phantom is used as a baseline). The depletion method, however, needs a priori information of the attenuation coefficient (AC) of the assessed media. For this reason, recently, a work introduced a simultaneous estimator of the B/A and AC based on fitting depletion method measurements to a nonlinear model using the iterative algorithm Gauss-Newton Levenberg-Marquardt (GNLM). However, the GNLM method presented high sensitivity to the initial guess values of the algorithm which limits the robustness of the approach. In the present work, the Gauss-Newton method is combined with a total variation regularization approach (GNTV), which is achievable by expanding the nonlinear model of the GNLM method for joint estimation of the B/A and AC of all pixels of the parametric images instead of a block-wise approach. In addition, the GNTV used compounding data from several tone-burst transmissions at different center frequencies rather than only one narrowband tone-burst. The results suggest that incorporating regularization and increasing the number of frequencies improves the robustness of the GNTV compared to the GNLM method by accurately estimating B/A values in uniform and nonuniform experimental phantoms (mean relative error less than 18%). The best performance of B/A reconstruction was observed when the sample medium exhibited a constant Gol’dberg number.

  • Open Access

    Nonlinearity parameter estimation method from fundamental band signal depletion in pulse-echo using a dual-energy model

    by Andres Coila, Adriana Romero, Michael L. Oelze, Roberto Lavarello

    The estimation of the nonlinearity parameter (B/A) has the potential to be used in the clinical diagnosis of conditions such as liver steatosis. Recently, a pulse-echo method to estimate B/A based on the theory of the fundamental band amplitude depletion of weak waves, namely, the depletion method, was proposed. In the present work, the depletion method is presented with more technical detail. Then, the robustness of the depletion method is assessed by using simulations that diverge from the model requirements: (1) monochromatic plane wave propagation and (2) quadratic power-law frequency dependence attenuation. Regarding requirement (1), the results led to a critical finding that when using wideband pulses (37%–113% bandwidth), the bias of the B/A estimates is larger than the bias obtained using narrowband pulses (11%–28% bandwidth), even if requirement (2) holds. Regarding requirement (2), power-law frequency dependence closer to those of soft tissues, i.e., 1.1 or 1.2, using narrowband pulses presented bias of less than 10%. The use of narrowband pulses also was shown to be robust when the reference phantom and sample had attenuation mismatches of around 60%. Finally, the experimental feasibility of the depletion method was evaluated, showing results with good accuracy (bias <17%), which are consistent with the observations in the simulations.


  • Ultrasonic backscatter coefficient estimation in nonlinear regime using an in situ calibration target

    by Andres Coila, Michael L. Oelze

    Tissue characterization based on the backscatter coefficient (BSC) can be degraded by acoustic nonlinearity. Often, this degradation is due to the method used for obtaining a reference spectrum, i.e., using a planar reference in water compared to a reference phantom approach resulted in more degradation. We hypothesize that an in situ calibration approach can improve BSC estimates in the nonlinear regime compared to using the reference phantom approach. The in situ calibration target provides a reference within the medium being interrogated and, therefore, nonlinear effects would already be contained in the in situ reference signal. Simulations and experiments in phantoms and in vivo were performed. A 2 mm diameter titanium bead was embedded in the interrogated media. An L9-4/38 probe (BK Ultrasound, Peabody, MA) and an analysis bandwidth from 4.5 to 7.4 MHz were used in experiments. Radiofrequency data from the sample, bead, and reference phantoms were acquired at a quasi-linear baseline power level and at further increments of output power. Better agreement between the BSC obtained at low power compared to high power was observed for the in situ calibration compared to the reference phantom approach.


  • Identifying and overcoming limitations with in situ calibration beads for quantitative ultrasound

    by Jenna Cario, Andres Coila, Yuning Zhao, Rita J. Miller, Michael L. Oelze

    Ensuring the consistency of spectral-based quantitative ultrasound estimates in vivo necessitates accounting for diffraction, system effects, and propagation losses encountered in the tissue. Accounting for diffraction and system effects is typically achieved through planar reflector or reference phantom methods; however, neither of these is able to account for the tissue losses present in vivo between the ultrasound probe and the region of interest. In previous work, the feasibility of small titanium beads as in situ calibration targets (0.5–2 mm in diameter) was investigated. In this study, the importance of bead size for the calibration signal, the role of multiple echoes coming from the calibration bead, and sampling of the bead signal laterally through beam translation were examined. This work demonstrates that although the titanium beads naturally produce multiple reverberant echoes, time-windowing of the first echo provides the smoothest calibration spectrum for backscatter coefficient calculation. When translating the beam across the bead, the amplitude of the echo decreases rapidly as the beam moves across and past the bead. Therefore, to obtain consistent calibration signals from the bead, lateral interpolation is needed to approximate signals coming from the center of the bead with respect to the beam.


  • Total attenuation compensation for backscatter coefficient estimation using full angular spatial compounding

    by Andres Coila, Julien Rouyer, Omar Zenteno, Adam Luchies, Michael L. Oelze, Roberto Lavarello


  • Effects of acoustic nonlinearity on pulse-echo attenuation coefficient estimation from tissue-mimicking phantoms

    by Andres Coila, Michael L. Oelze

    The ultrasonic attenuation coefficient (ACE) can be used to classify tissue state. Pulse-echo spectral-based attenuation estimation techniques, such as the spectral-log-difference method (SLD), account for beam diffraction effects using a reference phantom having a sound speed close to the sound speed of the sample. Methods like SLD assume linear propagation of ultrasound and do not account for potential acoustic nonlinear distortion of the backscattered power spectra in both sample and reference. In this study, the ACE of a sample was computed and compared using the SLD with two independent references (high attenuating and low attenuating phantoms but with similar B/A values) and over several pressure levels. Both numerical and physical tissue-mimicking phantoms were used in the study. The results indicated that the biases in ACE increased when using a reference having low attenuation, whereas the high attenuating reference produced more consistent ACE. Furthermore, increments in ACE vs input pressure were correlated to the log-ratio of Gol'dberg numbers between the sample and reference ( R 2 = 0.979 in simulations and R 2 = 0.734 in experiments). Therefore, the results suggest that to reduce bias in ACE using spectral-based methods, both the sound speed and the Gol'dberg number of the reference phantom should be matched to the sample.


  • Effects of Acoustic Nonlinearities on the Estimation of Attenuation from Ultrasonic Backscatter

    by Andres Coila, Michael Oelze

    The attenuation coefficient (AC) has demonstrated the ability to classify tissue state. Linear acoustic propagation is assumed when estimating the AC using spectral-based methods from the ultrasonic backscatter. However, the effects of acoustic nonlinearities can distort the backscattered power spectra versus depth. The distortion of the power spectra could result in a bias in the estimation of the AC. The goal of the study was to quantify the effects of nonlinear distortion on the estimation of AC from ultrasonic backscatter using spectral methods. We computed the AC from backscattered signals using the spectral log difference method and a reference phantom to account for diffraction effects. Computational simulations and experiments in phantoms were performed. In the experiments, three tissue-mimicking phantoms, named A, B and C having estimated AC values of 0.60, 0.90, and 0.20 dB/cm/MHz, respectively, and B/A ≈ 6.6 for each phantom were scanned using a single-element focused transducer (f/2) having a 0.5" diameter and 5-MHz center frequency. The phantoms were scanned using six excitation levels from a high-power (HP) pulsing apparatus (RAM-5000, Ritec, USA). The AC was estimated from phantom A using either phantom B (high attenuation) or phantom C (low attenuation) as the reference. The AC was estimated at each excitation level over the analysis bandwidth (− 6-dB criterion) to determine the effects of acoustic nonlinearity on estimation of AC. The presence of nonlinear distortion can be quantified through the Gol’dberg number, which is inversely proportional to the product of the nonlinearity coefficient and attenuation. We hypothesized that because the B/A values were approximately the same for each phantom, the effects of nonlinear distortion would be more pronounced when using phantom C, which had much lower attenuation. Specifically, increased excess attenuation due to transfer of energy from the fundamental to the harmonics would be observed more in phantom C. The AC estimate increased from 0.57 to 0.67 dB/cm/MHz as the excitation levels increased from level one to six when using phantom B as a reference. In contrast, when using phantom C as reference, the estimated AC slope of phantom A decreased from 0.57 to 0.43 dB/cm/MHz as the excitation levels increased from level one to six. Therefore, use of a reference with different attenuation resulted in increased bias of AC estimates due to nonlinear distortion being this deviation larger when using low attenuating media.


  • Backscatter Coefficient Estimation Bias under Acoustic Nonlinearities

    by Andres Coila, Michael Oelze

    The backscatter coefficient (BSC) describes the scattering properties of a medium and can be used to characterize tissue. To calculate the BSC a calibration spectrum is required, which can be acquired using either a reference phantom method (RPM) or the planar reflector method (PRM). Although ultrasonic propagation is quasilinear at low acoustic pressures, for high acoustic pressures, acoustic nonlinear distortion becomes prevalent. Because water is low loss, use of the PRM method may introduce significant nonlinearities to the BSC estimation. In this study, we assessed the effects of the acoustic nonlinearities on BSC estimation when using the RPM and the PRM. Phantoms were scanned by exciting a single-element focused transducer (f/2) using one excitation level from low-power (LP) equipment (5800 PR, Panametrics Olympus, USA) and six excitation levels (EL1 to EL6) from high-power (HP) equipment (RAM-5000, Ritec, USA). This resulted in scanning the phantoms with increasingly higher pressures, but still within FDA limits for diagnostic ultrasound. The two phantoms, labelled phantoms A and B, had glass beads with diameters in the range 75-90 and 9-43 μm, respectively. The BSCs estimated with the LP system were used as a baseline. The normalized root-mean-squared error (RMSE) was calculated from BSCs estimated using the HP system with respect to the baseline. The BSC was parameterized to estimate the effective scatterer diameters (ESD) for each phantom using Faran’s scattering theory. The BSC estimates resulted in smaller variations versus excitation levels for the RPM compared to the PRM. In the PRM, the RMSE was 0.62 ± 0.42 and 0.98 ± 0.77 for phantoms A and B, respectively; whereas, in the RPM, the RMSE was 0.21 ± 0.06 and 0.25 ± 0.12 for phantoms A and B, respectively. The ESD for the phantom A using the PRM decreased from 75 μm for EL1 to 39 μm for EL6; and using the RPM the ESD was 74.7 ± 2.3 μm across all settings. The ESD for the phantom B using the PRM decreased from 47 μm for EL1 to 0.5 μm for EL6; and using the RPM the ESD was 39.2 ± 5.6 μm across all settings. The RPM method was more robust against nonlinear distortion compared to the PRM because the PRM was used in water, where low loss resulted in large nonlinear distortion of the reference pulse.

  • Open Access

    Effects of acoustic nonlinearities on the ultrasonic backscatter coefficient estimation

    by Andres Coila, Michael L. Oelze

    The backscatter coefficient (BSC) is a fundamental property of tissues and can be used to classify tissues. Two BSC calibration methods are the planar reflector method and the reference phantom method. In both methods, linear acoustic propagation is assumed. In this study, the calibration methods were evaluated when acoustic nonlinear distortion was present. Radio frequency data were acquired from two physical phantoms using a 5 MHz single-element transducer and low power (one excitation level) and high power (six increasing excitation levels) excitation signals. BSCs estimated from the high power settings were compared to the BSCs estimated using the low power by calculating the root mean square error (RMSE). The BSCs were parameterized by fitting the BSC curve to a power law and estimating the power law exponent and by estimating the effective scatterer diameter (ESD). When using the planar reflector method, estimates of the exponent were observed to monotonically increase in value versus increasing excitation level and the ESD decreased with increasing excitation level. The RMSE increased monotonically versus excitation level using the planar reflector method but did not increase using the reference phantom method. The results suggest that the effects of nonlinear distortion are minimized using the reference phantom method.