Somayeh Dehghan Banadkooki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Somayeh Dehghan Banadkooki has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Zakiyeh Donyavi
Department of Endodontics, Dental School, Mashad University of Medical Sciences, Mashad, Iran
2 shared publications - Avin Hafedi
Oral Biology, College of Dentistry, University of Illinois Chicago, Chicago, IL, United States
1 shared publication - Masoumeh Hasani Tabatabaei
Department of Operative Dentistry, School of Dentistry Tehran University of Medical Sciences Tehran Iran
1 shared publication Nadia Veisy
Dental Students' Scientific Research Center, School of Dentistry, Tehran University of Medical Science, Tehran, Iran
1 shared publicationNarges Ranjpour
Department of Endodontics, Clinical Research Development Unit, School of Dentistry, Alborz University of Medical Sciences, Karaj, Iran
1 shared publication- Seyed Hossein Bassir
Univ Tehran Med Sci, Dent Res Ctr, Sch Dent, Tehran 1439955991, Iran
1 shared publication
Latest Publications
- Open Access
- 30 December 2024
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 16 (4) , 232-237
Comparison of Apically Extruded Debris Using Neoniti A1, ProTaper Gold, and WaveOne Gold Rotary Files in Mandibular Premolars: An In Vitro Study
Background: One of the main stages of root treatment is mechanical preparation, which is performed using manual and rotary instruments with rotational and reciprocal movement. Complete debridement of the root canal in the preparation process is essential for a successful endodontic treatment. This study investigated the amount of apically extruded debris using WaveOne Gold, ProTaper Gold (PTG), and Neoniti A1 rotary files in mandibular premolars. Methods: As many as 60 mandibular premolar teeth were divided into three equal groups. Each group was prepared with a rotary file (WaveOne Gold, PTG, or Neoniti A1). Then, debris measurements were performed using the Montgomery method, and SPSS v-26 and robust and Brown-Forsythe tests were used for data analysis. Results: The results showed that the highest and lowest amounts of extruded debris were in the PTG and WaveOne Gold files, respectively. There was a significant difference between the means of the three groups (P ˂ 0.05). In addition, to further evaluate the difference, the Games-Howell post hoc test was utilized, demonstrating a significant difference between the means of all three groups (P ˂ 0.001). Conclusion: The findings revealed that all systems extrude debris beyond the apical foramen. The WaveOne Gold system showed the lowest average value of apically extruded debris, followed by Neoniti A1, while ProTaper had the highest average value of apically extruded debris among the investigated systems. Thus, it is recommended that future studies investigate the effects of the properties and characteristics associated with the type of rotary files.
- 30 December 2024
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 16 (4) , 232-237
Open AccessComparison of Apically Extruded Debris Using Neoniti A1, ProTaper Gold, and WaveOne Gold Rotary Files in Mandibular Premolars: An In Vitro Study
Background: One of the main stages of root treatment is mechanical preparation, which is performed using manual and rotary instruments with rotational and reciprocal movement. Complete debridement of the root canal in the preparation process is essential for a successful endodontic treatment. This study investigated the amount of apically extruded debris using WaveOne Gold, ProTaper Gold (PTG), and Neoniti A1 rotary files in mandibular premolars. Methods: As many as 60 mandibular premolar teeth were divided into three equal groups. Each group was prepared with a rotary file (WaveOne Gold, PTG, or Neoniti A1). Then, debris measurements were performed using the Montgomery method, and SPSS v-26 and robust and Brown-Forsythe tests were used for data analysis. Results: The results showed that the highest and lowest amounts of extruded debris were in the PTG and WaveOne Gold files, respectively. There was a significant difference between the means of the three groups (P ˂ 0.05). In addition, to further evaluate the difference, the Games-Howell post hoc test was utilized, demonstrating a significant difference between the means of all three groups (P ˂ 0.001). Conclusion: The findings revealed that all systems extrude debris beyond the apical foramen. The WaveOne Gold system showed the lowest average value of apically extruded debris, followed by Neoniti A1, while ProTaper had the highest average value of apically extruded debris among the investigated systems. Thus, it is recommended that future studies investigate the effects of the properties and characteristics associated with the type of rotary files.
- Open Access
- 1 February 2024
- Published by Apex Publishing in Alborz University Medical Journal
- Vol. 13 (1) , 17-25
Effect of Spreader Taper on Root Fracture Resistance in Canals Obturated with Gutta-Percha/AH26 By Lateral Condensation Technique
Aim and background: This study was performed to investigate the effect of taper of stainless-steel spreader on root fracture resistance by applying the same force. Materials and methods: This study was performed on forty extracted lateral maxillary teeth. Root canal preparation was performed on all samples. Before canal obturation, samples ...
- 1 February 2024
- Published by Apex Publishing in Alborz University Medical Journal
- Vol. 13 (1) , 17-25
Open AccessEffect of Spreader Taper on Root Fracture Resistance in Canals Obturated with Gutta-Percha/AH26 By Lateral Condensation Technique
Aim and background: This study was performed to investigate the effect of taper of stainless-steel spreader on root fracture resistance by applying the same force. Materials and methods: This study was performed on forty extracted lateral maxillary teeth. Root canal preparation was performed on all samples. Before canal obturation, samples ...
- Open Access
- 26 July 2013
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 7 (1) , 62-67
Effect of Food Stimulated Liquids and Thermocycling on the Monomer Elution from a Nanofilled Composite
The present study was aimed to evaluate the effects of food simulating liquids and thermocycling on the elution of monomers from a nanofilled resin composite in different immersion times. Five Specimen discs were made from a nano-hybrid composite (Supreme 3M) for each group (Total = 180) and immersed in distilled water (control), citric acid, lactic acid, and 75% aqueous ethanol solution. The discs were removed after 24 h, 48 h, 72 h, 1 wk, 4 wk, and 12 wk. Three groups of samples underwent thermocycling for 1000, 2000 and 3000 cycles. The solutes were analyzed with HPLC for detection of eluted monomers. The results showed that the amount of released TEGDMA was significantly higher than that of Bis-GMA; however, there were not any significant differences between the amount of released Bis-GMA and UDMA. Moreover, the highest amount of monomers was released from samples immersed in ethanol solution; samples immersed in citric acid and lactic acid significantly released more monomers than those immersed in distilled water. Furthermore, the immersion time in aqueous ethanol solution had an increasing effect on the release of monomers. In addition, the higher amounts of monomers were release from samples immersed in ethanol and citric acid which underwent a higher number of thermal cycles. In conclusion, food and drink stimulated liquids used in this study increased the amount of some of the monomers released from composite resin. Thermal shocks and storage time are other factors that increased the release of monomers from the composite resin
- 26 July 2013
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 7 (1) , 62-67
Open AccessEffect of Food Stimulated Liquids and Thermocycling on the Monomer Elution from a Nanofilled Composite
The present study was aimed to evaluate the effects of food simulating liquids and thermocycling on the elution of monomers from a nanofilled resin composite in different immersion times. Five Specimen discs were made from a nano-hybrid composite (Supreme 3M) for each group (Total = 180) and immersed in distilled water (control), citric acid, lactic acid, and 75% aqueous ethanol solution. The discs were removed after 24 h, 48 h, 72 h, 1 wk, 4 wk, and 12 wk. Three groups of samples underwent thermocycling for 1000, 2000 and 3000 cycles. The solutes were analyzed with HPLC for detection of eluted monomers. The results showed that the amount of released TEGDMA was significantly higher than that of Bis-GMA; however, there were not any significant differences between the amount of released Bis-GMA and UDMA. Moreover, the highest amount of monomers was released from samples immersed in ethanol solution; samples immersed in citric acid and lactic acid significantly released more monomers than those immersed in distilled water. Furthermore, the immersion time in aqueous ethanol solution had an increasing effect on the release of monomers. In addition, the higher amounts of monomers were release from samples immersed in ethanol and citric acid which underwent a higher number of thermal cycles. In conclusion, food and drink stimulated liquids used in this study increased the amount of some of the monomers released from composite resin. Thermal shocks and storage time are other factors that increased the release of monomers from the composite resin