Pablo González-Altozano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pablo González-Altozano has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- María Gasque
Departament de Física Aplicada, ETSEAMN, Universitat Politècnica de València
12 shared publications - Pau Martí
Departament d’Enginyeria Industrial i Construcció, Àrea d’Enginyeria Agroforestal, Universitat de les Illes Balears, Palma, Spain
9 shared publications - Guillermo Palau-Salvador
Universitat Politècnica de València, INGENIO CSIC-UPV
6 shared publications Rosa Penélope Gutiérrez-Colomer
4 shared publicationsEugenio García-Marí
3 shared publicationsMaría Gasque
3 shared publications
Latest Publications
- Open Access
- 25 April 2026
- Published by Springer Nature in Irrigation Science
- Vol. 44 (4) , 79
Rootstock-specific responses of ‘Rojo Brillante’ persimmon grafted onto Diospyros lotus and Diospyros virginiana to irrigation dose and planting layout, with implications for water status, fruit abscission and irrigation water productivity
- 25 April 2026
- Published by Springer Nature in Irrigation Science
- Vol. 44 (4) , 79
Open AccessRootstock-specific responses of ‘Rojo Brillante’ persimmon grafted onto Diospyros lotus and Diospyros virginiana to irrigation dose and planting layout, with implications for water status, fruit abscission and irrigation water productivity
- Open Access
- 10 December 2025
- Published by MDPI AG in Agriculture
- Vol. 15 (24) , 2557
Assessing Reference Evapotranspiration Estimation Considering Irrigation Scheduling Intervals
Accurate estimation of reference evapotranspiration (ETo) is essential for irrigation planning in semi-arid Mediterranean regions. This study evaluated temperature-based and neural network models for estimating daily ETo and its accumulated values over multiple timescales, using data from two lysimeter stations in Albacete and Badajoz, Spain. Model performance was assessed against the FAO56 PM equation and against lysimeter measurements to quantify the joint effect of benchmark choice and temporal aggregation. Under FAO56 PM benchmarking, RRMSE for temperature-based models in Albacete decreased from about 0.18 for daily ETo to around 0.08 for monthly accumulated ETo, while complex models achieved daily RRMSE near 0.06–0.07, and all models exhibited RRMSE below 0.08 at monthly and longer scales. When lysimeter ETo was used as the benchmark, errors increased and became more variable in winter, with daily RRMSE often exceeding 0.22, indicating reduced lysimeter reliability under cold, calm conditions. Overall, extending the estimation interval from daily to multi-day periods markedly reduced errors and narrowed differences among models. These results show that, in the semi-arid Mediterranean environments studied, temperature-based models can provide operationally reliable estimates at irrigation-relevant timescales, while FAO56 PM offers a more robust primary benchmark than lysimeter measurements for winter irrigation planning.
- 10 December 2025
- Published by MDPI AG in Agriculture
- Vol. 15 (24) , 2557
Open AccessAssessing Reference Evapotranspiration Estimation Considering Irrigation Scheduling Intervals
Accurate estimation of reference evapotranspiration (ETo) is essential for irrigation planning in semi-arid Mediterranean regions. This study evaluated temperature-based and neural network models for estimating daily ETo and its accumulated values over multiple timescales, using data from two lysimeter stations in Albacete and Badajoz, Spain. Model performance was assessed against the FAO56 PM equation and against lysimeter measurements to quantify the joint effect of benchmark choice and temporal aggregation. Under FAO56 PM benchmarking, RRMSE for temperature-based models in Albacete decreased from about 0.18 for daily ETo to around 0.08 for monthly accumulated ETo, while complex models achieved daily RRMSE near 0.06–0.07, and all models exhibited RRMSE below 0.08 at monthly and longer scales. When lysimeter ETo was used as the benchmark, errors increased and became more variable in winter, with daily RRMSE often exceeding 0.22, indicating reduced lysimeter reliability under cold, calm conditions. Overall, extending the estimation interval from daily to multi-day periods markedly reduced errors and narrowed differences among models. These results show that, in the semi-arid Mediterranean environments studied, temperature-based models can provide operationally reliable estimates at irrigation-relevant timescales, while FAO56 PM offers a more robust primary benchmark than lysimeter measurements for winter irrigation planning.
- Open Access
- 5 June 2024
- Published by Elsevier in Agricultural Water Management
- Vol. 300
Seasonal assessment of the grass reference evapotranspiration estimation from limited inputs using different calibrating time windows and lysimeter benchmarks
- 5 June 2024
- Published by Elsevier in Agricultural Water Management
- Vol. 300
Open AccessSeasonal assessment of the grass reference evapotranspiration estimation from limited inputs using different calibrating time windows and lysimeter benchmarks
- Open Access
- 2 February 2024
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 22
Technical performance analysis of high-voltage battery-based photovoltaic water pumping systems
- 2 February 2024
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 22
Open AccessTechnical performance analysis of high-voltage battery-based photovoltaic water pumping systems
- Open Access
- 25 April 2023
- Published by Springer Nature in Irrigation Science
- Vol. 41 (6) , 817-834
Optimization of an isolated photovoltaic water pumping system with technical–economic criteria in a water users association
With proper management, the modernization of irrigation systems makes it possible to improve the efficiency of application and use of water at the cost of an increase in pumping needs and, therefore, an increment of the energy consumed. The recent drastic price increase for energy put the viability of many farms at risk. In this context, using photovoltaic solar energy to power pumping stations has become an increasingly attractive alternative and a cheap and reliable option. The dimensioning of pumping systems powered by photovoltaic solar energy must be done considering the variability of solar radiation to take advantage of the available photovoltaic energy, especially during periods of less irradiation. By investigating a particular case, this paper studies the effect of increasing the number of pumps in parallel while maintaining the total power, as well as the relationship between the installed photovoltaic capacity and the power of the pumping system, to meet pumping requirements throughout the year. The pumped volume increased as the number of pumps installed in parallel increased for the same photovoltaic power generator. Although this increment has a limit, beyond which no greater significant rise in volume is achieved, installation costs increase. In addition, for the same pumping power installed, the required photovoltaic generator power decreases as the number of pumps in parallel increases. In the case studied, a 27% increase in the annual pumped volume was achieved by incrementing the number of pumps in parallel from one to five, thus leading to a 44.1% reduction in the size of the photovoltaic generator and a 13.3% reduction in the cost of installation compared with a system with only one pump. The procedure used to determine the most appropriate number of pumps to install in parallel when pumping water between two tanks, which minimizes the photovoltaic generator's size while guaranteeing pumping requirements, is easily generalizable for sizing isolated photovoltaic water pumping systems.
- 25 April 2023
- Published by Springer Nature in Irrigation Science
- Vol. 41 (6) , 817-834
Open AccessOptimization of an isolated photovoltaic water pumping system with technical–economic criteria in a water users association
With proper management, the modernization of irrigation systems makes it possible to improve the efficiency of application and use of water at the cost of an increase in pumping needs and, therefore, an increment of the energy consumed. The recent drastic price increase for energy put the viability of many farms at risk. In this context, using photovoltaic solar energy to power pumping stations has become an increasingly attractive alternative and a cheap and reliable option. The dimensioning of pumping systems powered by photovoltaic solar energy must be done considering the variability of solar radiation to take advantage of the available photovoltaic energy, especially during periods of less irradiation. By investigating a particular case, this paper studies the effect of increasing the number of pumps in parallel while maintaining the total power, as well as the relationship between the installed photovoltaic capacity and the power of the pumping system, to meet pumping requirements throughout the year. The pumped volume increased as the number of pumps installed in parallel increased for the same photovoltaic power generator. Although this increment has a limit, beyond which no greater significant rise in volume is achieved, installation costs increase. In addition, for the same pumping power installed, the required photovoltaic generator power decreases as the number of pumps in parallel increases. In the case studied, a 27% increase in the annual pumped volume was achieved by incrementing the number of pumps in parallel from one to five, thus leading to a 44.1% reduction in the size of the photovoltaic generator and a 13.3% reduction in the cost of installation compared with a system with only one pump. The procedure used to determine the most appropriate number of pumps to install in parallel when pumping water between two tanks, which minimizes the photovoltaic generator's size while guaranteeing pumping requirements, is easily generalizable for sizing isolated photovoltaic water pumping systems.
- Open Access
- 16 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 54064-54078
Energy Efficiency Optimization in Battery-Based Photovoltaic Pumping Schemes
This article deals with the analysis of energy efficiency optimization in battery-based photovoltaic pumping schemes. The study builds on previous findings derived from the comparison between a direct photovoltaic water pumping system (DPVWPS) and the equivalent system including a lithium-ion battery (LIB). The initial experimental results of the battery-based photovoltaic water pumping system (PVWPS+LIB) were obtained with the motor-pump group operating at its rated condition of 50 Hz. In the present work, an analysis of the efficiency and the performance ratio of the variable speed drive (VSD) and the motor-pump group, showed that both parameters improve when operating in the low frequency range of the VSD and far from the rated frequency where the flow rate is maximized. Several fitting models were performed with the data obtained with the monitoring system and it was concluded that an overall energy efficiency optimization can be achieved with a VSD frequency equal to 37 Hz. A comparison of the experimental results obtained with the VSD working in the direct mode and with the battery-based solution (setting different VSD frequencies – 50 Hz, 37 Hz, and a combination of the two frequencies designed as 37/50/37 Hz) was made to determine the efficiency and performance ratios in each case. The results presented in this study also establish criteria for improving efficiencies in the LIB charging and discharging processes.
- 16 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 54064-54078
Open AccessEnergy Efficiency Optimization in Battery-Based Photovoltaic Pumping Schemes
This article deals with the analysis of energy efficiency optimization in battery-based photovoltaic pumping schemes. The study builds on previous findings derived from the comparison between a direct photovoltaic water pumping system (DPVWPS) and the equivalent system including a lithium-ion battery (LIB). The initial experimental results of the battery-based photovoltaic water pumping system (PVWPS+LIB) were obtained with the motor-pump group operating at its rated condition of 50 Hz. In the present work, an analysis of the efficiency and the performance ratio of the variable speed drive (VSD) and the motor-pump group, showed that both parameters improve when operating in the low frequency range of the VSD and far from the rated frequency where the flow rate is maximized. Several fitting models were performed with the data obtained with the monitoring system and it was concluded that an overall energy efficiency optimization can be achieved with a VSD frequency equal to 37 Hz. A comparison of the experimental results obtained with the VSD working in the direct mode and with the battery-based solution (setting different VSD frequencies – 50 Hz, 37 Hz, and a combination of the two frequencies designed as 37/50/37 Hz) was made to determine the efficiency and performance ratios in each case. The results presented in this study also establish criteria for improving efficiencies in the LIB charging and discharging processes.
- Open Access
Minimum Number of Experimental Data for the Thermal Characterization of a Hot Water Storage Tank
This paper demonstrates that it is possible to characterize the water temperature profile and its temporal trend in a hot water storage tank during the thermal charge process, using a minimum number of thermocouples (TC), with minor differences compared to experimental data. Four experimental tests (two types of inlet and two water flow rates) were conducted in a 950 L capacity tank. For each experimental test (with 12 TC), four models were developed using a decreasing number of TC (7, 4, 3 and 2, respectively). The results of the estimation of water temperature obtained with each of the four models were compared with those of a fifth model performed with 12 TC. All models were tested for constant inlet temperature. Very acceptable results were achieved (RMSE between 0.2065 °C and 0.8706 °C in models with 3 TC). The models were also useful to estimate the water temperature profile and the evolution of thermocline thickness even with only 3 TC (RMSE between 0.00247 °C and 0.00292 °C). A comparison with a CFD model was carried out to complete the study with very small differences between both approaches when applied to the estimation of the instantaneous temperature profile. The proposed methodology has proven to be very effective in estimating several of the temperature-based indices commonly employed to evaluate thermal stratification in water storage tanks, with only two or three experimental temperature data measurements. It can also be used as a complementary tool to other techniques such as the validation of numerical simulations or in cases where only a few experimental temperature values are available.
Open AccessMinimum Number of Experimental Data for the Thermal Characterization of a Hot Water Storage Tank
This paper demonstrates that it is possible to characterize the water temperature profile and its temporal trend in a hot water storage tank during the thermal charge process, using a minimum number of thermocouples (TC), with minor differences compared to experimental data. Four experimental tests (two types of inlet and two water flow rates) were conducted in a 950 L capacity tank. For each experimental test (with 12 TC), four models were developed using a decreasing number of TC (7, 4, 3 and 2, respectively). The results of the estimation of water temperature obtained with each of the four models were compared with those of a fifth model performed with 12 TC. All models were tested for constant inlet temperature. Very acceptable results were achieved (RMSE between 0.2065 °C and 0.8706 °C in models with 3 TC). The models were also useful to estimate the water temperature profile and the evolution of thermocline thickness even with only 3 TC (RMSE between 0.00247 °C and 0.00292 °C). A comparison with a CFD model was carried out to complete the study with very small differences between both approaches when applied to the estimation of the instantaneous temperature profile. The proposed methodology has proven to be very effective in estimating several of the temperature-based indices commonly employed to evaluate thermal stratification in water storage tanks, with only two or three experimental temperature data measurements. It can also be used as a complementary tool to other techniques such as the validation of numerical simulations or in cases where only a few experimental temperature values are available.
- Open Access
- 14 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 101147-101163
Photovoltaic Water Pumping: Comparison Between Direct and Lithium Battery Solutions
This work presents the conversion of a photovoltaic water pumping system (PVWPS) to its corresponding battery-based solution, while maintaining the components of the PVWPS facility and adding the power converter needed to manage the operation of a lithium-ion battery. A complete analysis of the direct PVWPS is performed based on the values obtained by the monitoring system developed for the installation. The efficiencies and performance ratios of the various elements of the facility are calculated, as well as other relevant factors (such as irradiance thresholds). The dependence of some variables on the solar resource is analyzed to model the system. A similar study is carried out in the battery-based solution and a comparative analysis of the two modes of operation is then performed to find which aspects could be improved in the battery-based solution to increase the pumping time and total daily pumped volume. The results presented demonstrate the benefits of including a battery (reduction in start/stop cycles and improved performance on cloudy days). Aspects that can be improved to make the battery-based solution more efficient and achieve better results are suggested.
- 14 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 101147-101163
Open AccessPhotovoltaic Water Pumping: Comparison Between Direct and Lithium Battery Solutions
This work presents the conversion of a photovoltaic water pumping system (PVWPS) to its corresponding battery-based solution, while maintaining the components of the PVWPS facility and adding the power converter needed to manage the operation of a lithium-ion battery. A complete analysis of the direct PVWPS is performed based on the values obtained by the monitoring system developed for the installation. The efficiencies and performance ratios of the various elements of the facility are calculated, as well as other relevant factors (such as irradiance thresholds). The dependence of some variables on the solar resource is analyzed to model the system. A similar study is carried out in the battery-based solution and a comparative analysis of the two modes of operation is then performed to find which aspects could be improved in the battery-based solution to increase the pumping time and total daily pumped volume. The results presented demonstrate the benefits of including a battery (reduction in start/stop cycles and improved performance on cloudy days). Aspects that can be improved to make the battery-based solution more efficient and achieve better results are suggested.