Jalil Jalali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jalil Jalali has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Maximilian Eder
Research Group CAPS-Computer Aided Plastic Surgery, Department of Plastic Surgery and Hand Surgery, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany
3 shared publicationsAlexander Volf
Technische Universität München
2 shared publicationsHans-Günther Machens
Technische Universität München
2 shared publicationsJ. Sass
Research Group CAPS - Computer Aided Plastic Surgery, Department of Plastic Surgery and Hand Surgery, University Hospital Klinikum rechts der Isar, Technical University Munich, Germany
2 shared publicationsL. Kovacs
FIFA Medical Center of Excellence, Division of Knee, Hip and Shoulder Surgery, Schoen Clinic Munich Harlaching, Academic Teaching Hospital of the Paracelsus Medical University (PMU), Salzburg, Austria
2 shared publicationsP.H. Thaller
Department of General, Trauma and Reconstructive Surgery, University Hospital, LMU Munich, Germany
2 shared publications
Latest Publications
- 18 December 2013
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 42 (4) , 843-857
Comparison of Different Material Models to Simulate 3-D Breast Deformations Using Finite Element Analysis
Biomechanical breast modeling using finite element (FE) analysis to predict 3-D breast deformations is of interest for various biomedical applications. Currently no consensus of reliable magnitudes of mechanical breast tissue properties exists. We therefore applied 12 material properties proposed in the literature to FE simulation models derived from prone MRI breast datasets of 18 female volunteers. A gravity free starting position is computed with an iterative FE algorithm followed by the calculation of the upright position of the breast and then compared to the real breast geometry in standing position using corresponding 3-D surface scans to determine the accuracy of the simulation. Hyper-elastic constitutive models showed superior performance than linear elastic models which cannot exceed the linear Hookean domain. Within the group of applied hyper-elastic material models those proposed by Tanner et al. (Med Phys 33:1758–1769, 2006) and Rajagopal et al. (Acad Radiol 15:1425–1436, 2008) performed significantly (p < 0.01) better than other material models. The advantage of the method presented is its non-invasive character by combining 3-D volume and surface imaging with automated FE analysis. Thus, reliable biomechanical breast models based on the presented methods can be applied in future to derive patient-specific material parameter sets to improve a wide range of healthcare applications.
- 18 December 2013
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 42 (4) , 843-857
Comparison of Different Material Models to Simulate 3-D Breast Deformations Using Finite Element Analysis
Biomechanical breast modeling using finite element (FE) analysis to predict 3-D breast deformations is of interest for various biomedical applications. Currently no consensus of reliable magnitudes of mechanical breast tissue properties exists. We therefore applied 12 material properties proposed in the literature to FE simulation models derived from prone MRI breast datasets of 18 female volunteers. A gravity free starting position is computed with an iterative FE algorithm followed by the calculation of the upright position of the breast and then compared to the real breast geometry in standing position using corresponding 3-D surface scans to determine the accuracy of the simulation. Hyper-elastic constitutive models showed superior performance than linear elastic models which cannot exceed the linear Hookean domain. Within the group of applied hyper-elastic material models those proposed by Tanner et al. (Med Phys 33:1758–1769, 2006) and Rajagopal et al. (Acad Radiol 15:1425–1436, 2008) performed significantly (p < 0.01) better than other material models. The advantage of the method presented is its non-invasive character by combining 3-D volume and surface imaging with automated FE analysis. Thus, reliable biomechanical breast models based on the presented methods can be applied in future to derive patient-specific material parameter sets to improve a wide range of healthcare applications.
- 5 October 2013
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 9 (4) , 541-549
Three-dimensional prediction of free-flap volume in autologous breast reconstruction by CT angiography imaging
Purpose The diagnostic use of computer tomography angiography (CTA) to identify perforating blood vessels for abdominal free-flap breast reconstruction was extended to estimate the three-dimensional (3D) preoperative flap volume and to compare it with the real intraoperative flap weights in order to (1) evaluate the accuracy of CTA-based 3D flap volume prediction, and (2) to analyze abdominal tissue estimation for required breast volume reconstruction. Methods Preoperative CTA was performed in 54 patients undergoing unilateral breast reconstruction with a free, deep, inferior epigastric artery perforator flap. 3D flap volumes (\(\hbox {cm}^{3}\)) based on CTA data were calculated and compared with the actual intraoperative flap weight (g). In addition, a breast volume to flap volume ratio was calculated to analyze whether the estimated 3D abdominal flap volume would match that of the breast to be removed. Results 40 CTA data sets (74.1 %) fulfilled the technical requirements for a reliable determination of flap volume. 3D CTA flap volume prediction showed no relevant differences to the actual flap weight (p = 0.44) and high correlations (r = 0.998, \(p < 0.001\)), allowing a prediction accuracy within 0.29 \(\pm \) 3.0 % (range: from \(-\)8.77 to 5.67 %) of the real flap weight. Significantly larger flap volumes were harvested compared with the actually required breast volumes (\(p < 0.001\)), leading to an average of 21 % of the remnant flap tissue potentially being discarded. Conclusions CTA-based 3D flap volume prediction provides accurate preoperative guidelines concerning the needed amount of abdominal tissue that can be harvested to achieve acceptable symmetry.- 5 October 2013
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 9 (4) , 541-549
Three-dimensional prediction of free-flap volume in autologous breast reconstruction by CT angiography imaging
Purpose The diagnostic use of computer tomography angiography (CTA) to identify perforating blood vessels for abdominal free-flap breast reconstruction was extended to estimate the three-dimensional (3D) preoperative flap volume and to compare it with the real intraoperative flap weights in order to (1) evaluate the accuracy of CTA-based 3D flap volume prediction, and (2) to analyze abdominal tissue estimation for required breast volume reconstruction. Methods Preoperative CTA was performed in 54 patients undergoing unilateral breast reconstruction with a free, deep, inferior epigastric artery perforator flap. 3D flap volumes (\(\hbox {cm}^{3}\)) based on CTA data were calculated and compared with the actual intraoperative flap weight (g). In addition, a breast volume to flap volume ratio was calculated to analyze whether the estimated 3D abdominal flap volume would match that of the breast to be removed. Results 40 CTA data sets (74.1 %) fulfilled the technical requirements for a reliable determination of flap volume. 3D CTA flap volume prediction showed no relevant differences to the actual flap weight (p = 0.44) and high correlations (r = 0.998, \(p < 0.001\)), allowing a prediction accuracy within 0.29 \(\pm \) 3.0 % (range: from \(-\)8.77 to 5.67 %) of the real flap weight. Significantly larger flap volumes were harvested compared with the actually required breast volumes (\(p < 0.001\)), leading to an average of 21 % of the remnant flap tissue potentially being discarded. Conclusions CTA-based 3D flap volume prediction provides accurate preoperative guidelines concerning the needed amount of abdominal tissue that can be harvested to achieve acceptable symmetry.- 1 March 2013
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 131 (3) , 437e-438e
Preoperative Flap Volume Prediction in Autologous Abdominal Breast Reconstruction
- 1 March 2013
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 131 (3) , 437e-438e
Preoperative Flap Volume Prediction in Autologous Abdominal Breast Reconstruction
- 1 July 2012
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 25 (04) , 301-306
Finite element analysis of the ovine hip: Development, results and comparison with the human hip
Summary: Objectives: The ovine hip is often used as an experimental research model to simulate the human hip. However, little is known about the contact pressures on the femoral and acetabular cartilage in the ovine hip, and if those are representative for the human hip.Methods: A model of the ovine hip, including the pelvis, femur, acetabular cartilage, femoral cartilage and ligamentum transversum, was built using computed tomography and microcomputed tomography. Using the finite element method, the peak forces were analysed during simulated walking.Results: The evaluation revealed that the contact pressure distribution on the femoral cartilage is horseshoe-shaped and reaches a maximum value of approximately 6 MPa. The maximum contact pressure is located on the dorsal acetabular side and is predominantly aligned in the cranial-to-caudal direction. The surface stresses acting on the pelvic bone reach an average value of approximately 2 MPa.Conclusions: The contact pressure distribution, magnitude, and the mean surface stress in the ovine hip are similar to those described in the current literature for the human hip. This suggests that in terms of load distribution, the ovine hip is well suited for the preclinical testing of medical devices designed for the human hip.
- 1 July 2012
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 25 (04) , 301-306
Finite element analysis of the ovine hip: Development, results and comparison with the human hip
Summary: Objectives: The ovine hip is often used as an experimental research model to simulate the human hip. However, little is known about the contact pressures on the femoral and acetabular cartilage in the ovine hip, and if those are representative for the human hip.Methods: A model of the ovine hip, including the pelvis, femur, acetabular cartilage, femoral cartilage and ligamentum transversum, was built using computed tomography and microcomputed tomography. Using the finite element method, the peak forces were analysed during simulated walking.Results: The evaluation revealed that the contact pressure distribution on the femoral cartilage is horseshoe-shaped and reaches a maximum value of approximately 6 MPa. The maximum contact pressure is located on the dorsal acetabular side and is predominantly aligned in the cranial-to-caudal direction. The surface stresses acting on the pelvic bone reach an average value of approximately 2 MPa.Conclusions: The contact pressure distribution, magnitude, and the mean surface stress in the ovine hip are similar to those described in the current literature for the human hip. This suggests that in terms of load distribution, the ovine hip is well suited for the preclinical testing of medical devices designed for the human hip.